• 제목/요약/키워드: Total effective temperature

검색결과 526건 처리시간 0.024초

애기뿔소똥구리(Copris tripartitus Waterhouse)의 발육에 미치는 온도의 영향 (Effect of Temperature on the Development of Copris tripartitus Waterhouse (Coleoptera: Scarabaeidae))

  • 방혜선;나영은;김명현;노기안;이정택
    • 한국응용곤충학회지
    • /
    • 제46권3호
    • /
    • pp.357-362
    • /
    • 2007
  • 토양의 비옥도를 높여주는 분식성 곤충으로써 우리나라에 서식하고 있는 애기뿔소똥구리(Copris tripartitus)의 발육생태를 각 온도에서 관찰하였다. 대량증식 및 환경변화 모델 적용을 위해 15, 17.5, 20, 25, 27.5 및 $30^{\circ}C$(16L:8D)에서 발육실험을 한 결과 알에서 우화까지의 발육기간은 $17.5^{\circ}C$에서 118.0일이고, $27.5^{\circ}C$에서는 49.3일이었다. 온도가 높을수록 짧은 발육기간을 보였으며, 알, 유충, 용, 알에서 우화까지의 발육영점온도와 유효적산온도는 각각 12.1, 11.2, 12.1, $9.2^{\circ}C$, 그리고 82.7, 462.0, 225.7, 947.2일도이었다. 난 및 유충의 발육단계에서 사망률은 $25^{\circ}C$에서 가장 낮게 나타나 애기뿔소똥구리의 성장에 적합한 온도는 $25^{\circ}C$이었다.

수직원통형 축열조내 물의 응고과정시 열전달에 관한 실험적연구 - 작동유체의 유동방향에 따른 열저장성능 비교 - (A Study of Heat Transfer during Freezing Process of Water in a Vertical Cylinder - Comparison of thermal storage performance on the working fluid direction -)

  • 허경;김영기;김영중;김준근;임장순
    • 태양에너지
    • /
    • 제15권2호
    • /
    • pp.77-90
    • /
    • 1995
  • 본 연구는 용융점 온도가 $0^{\circ}C$인 순수 물이 수직원통형 빙축열조 내에 각각 형상비(H/R)가 4와 2인 형태로 채워져 있을 경우 수직원관 내로 유입되는 작동유체의 온도를 $-10^{\circ}C$, 유량을 10 liter/min로 고정시킨 후 유동방향을 상향과 하향으로 변화시켰을 경우 시간경과에 따라 나타나는 물의 응고형상, 수직원통의 온도분포, 수직원관의 온도분포, 축열량에 대한 열전달현상을 실험적으로 규명한 것이다. 축열조내 물의 온도분포는 초기온도가 $7^{\circ}C$인 경우 냉각과정중 축열조내 상부가 하부보다 높고 시간경과 후 물의 최대밀도점인 $4^{\circ}C$ 이하에서는 축열조 하부가 상부보다 높으며, 초기온도가 $4^{\circ}C$$1^{\circ}C$인 경우는 물의 밀도값이 최대점인 $4^{\circ}C$ 이하이므로 실험시작 초기부터 하부가 상부보다 온도분포가 높게 나타났다. 응고과정 시에는 동일한 초기온도 하에서 작동유체의 유동방향이 상향일 경우가 하향일 경우보다 축열조내 자연대류 유동이 활발하여 액상의 평균온도는 빠르게 강하되고 수직원관 외벽면의 상 하부 온도차이도 적으며, 응고형상은 축열조내 물의 초기온도가 $7^{\circ}C$$4^{\circ}C$ 일 때 상 하부에서 고르게 진전된다. 축열조내 물의 초기온도가 $1^{\circ}C$인 경우는 전도열전달의 영향이 지배적이므로 응고층의 생성은 작동유체 유동방향으로 형성되어진다. 축열량은 형상비에 관계없이 초기온도가 높을수록 크게 나타났으며, 동일한 초기온도 하에서도 작동유체의 유동방향이 상향으로 유입될 경우가 하향에 유입되는 경우보다 시간경과 후 크게 나타났다.

  • PDF

고압/효소분해 처리에 의한 멸치 가수분해물의 제조 및 특성분석 (Preparation and Physicochemical Characteristics of Anchovy Hydrolysates Produced by High Hydrostatic Pressure and Enzymatic Hydrolysis Treatment)

  • 김민지;남궁배;김복남;이수정;김철진;조용진;김종태
    • 산업식품공학
    • /
    • 제13권2호
    • /
    • pp.85-91
    • /
    • 2009
  • 천연조미소재 개발을 위하여 고압/효소분해 시스템에서 멸치 단백질의 분해 품질특성을 탐색한 결과, 최적 조건은 효소농도 0.6%, 온도 50$^{\circ}C$, 처리시간 24시간 및 압력 50MPa로 확인되었다. 멸치 단백질의 처리방법에 따른 품질 특성을 비교한 결과, 최적조건하에서 고압/효소 처리한 멸치 가수분해물의 품질특성이 가열추출물인 대조구에 비하여 2.8배, 2배, 1.4배 증가하여 고압/효소 처리에 의한 단백질 가수분해물 생산은 가열추출법이나 고압반응에 비하여 효율적인 방법으로 나타났다. 효소종류에 따른 분해력은 복합효소로 가수분해한 경우 상업효소에 비하여 큰 증가율을 나타내어 복합효소의 분해력이 상업효소에 비하여 우수 하였다. 고압/효소 처리 후의 멸치 가수분해물은 정미성 아미노산으로 알려져 있는 glutamic acid, glycine, arginine 및 alanine 등의 함량이 대조구나 압력 처리구의 유리아미 노산 함량에 비하여 증가하였다. 결론적으로 고압/효소분해 처리공정은 멸치 단백질의 효과적 분해와 정미성 아미노산 생산에 효율적인 기술임을 확인하였다.

Simultaneous Gas Chromatography-Mass Spectrometric Determination of Total and Individual Phthalic Esters Utilizing Alkaline Hydrolysis and Silyl Derivatization Technique

  • Kim, Min-Seon;Li, Dong-Hao;Shim, Won-Joon;Oh, Jae-Ryoung;Park, Jong-Man
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권3호
    • /
    • pp.432-438
    • /
    • 2007
  • Environmentally important phthalic esters have been analyzed by GC-MS in terms of individual phthalic esters or total phthalic esters directly or after derivatization. Derivatization improves the chromatographic characteristics of the highly polar phthalic esters. This study focused on the GC-MS determination of the total phthalic esters and the individual phthalic esters simultaneously. The phthalic esters were hydrolyzed to phthalate and corresponding alcohols in 1 M NaOH solution at 90 oC for 30 min followed by extraction with ethyl acetate after acidifcation. The phthalic acid and alcohols were simultaneously silyl derivatized using bis(trimethylsilyl)trifluoroacetamide (BSTFA) to their corresponding silyl ester and ethers in the mixture of 60% acetone and 40% ethyl acetate at room temperature within 30 min. Because of the high reactivity of BSTFA with the phthalic acid and alcohols effective silyl derivatization was possible simultaneously. GC-MS analysis of the silyl derivatives of phthalic acid and alcohols was performed. The total phthalic ester content was estimated from the analytical result of phthalic silyl ester, while the individual phthalic ester was quantified from the analytical results of alcoholic silyl ethers. This technique was applied to spiked tab water and real seawater samples from the Lake Shihwa in Korea. The results were checked against the results from the direct GC-MS analysis of the phthalic esters and reasonable recoveries with high sensitivity were achieved. The recoveries were higher than 75% with low relative standard deviation (below 10%).

초음파와 극초단파를 이용한 송이버섯의 추출법과 다당체에 관한 연구 (Studies on the Extraction Method and Polysaccharide of Tricholoma matsutake using the Supersonic wave and Microwave)

  • 유승현;정명수;김혜자;이기남
    • 동의생리병리학회지
    • /
    • 제21권6호
    • /
    • pp.1431-1436
    • /
    • 2007
  • In order to optimize the extract condition and improve physiological activity of the extract form Tricholoma matsutake, experiments related to extraction methods, totale yield, content of total soluble polysaccharide, SOD-like activity, total polyphenol amount, and volatile flavor compound and the others were carried out, results were obtained as following: Compare with traditional hydrothermal extraction method (Hot water extraction : HWEW), it illustrates that the low temperature extraction method which combines a supersonic waves and microwave (Supersonic microwave extraction : SMEW) causes of increasing the total yield, total soluble polysaccharide. As to the anti-oxident effect, SMEW method leds to increasing of the SOD-like activity, total polyphenol amount as well. Also, cytotoxic effect and growth inhibitory effect against cancer cell line are much higher in SMEW method than HWEW method, especially SMEW5 extracts treated by supersonic 15 min. and microwave 120W, 3 min. and 2 times. The main volatile flavor compound and infinitesimal volatile flavor compound both increase significantly by SMEW method. It is concluded the main components of the volatile flavor compounds extracted from Tricholoma matsutake are 1-octen-3-0l, Methyl cinnamate, 2-octeno1 et al. alcohol typies. Consequently, SMEW5 method is considered as the most effective one for anti-oxidant and is prior to any other methods. And the optimun conditions of this method are : supersonic waves (supersonic, 25KHz, 50W) 15 minutes, microwave spectroscopy (microwave, 2,450MHz, 120W) 3 minutes, and every treatment is performed once followed twice repeats.

토양 시료 중 Atomic Absorption Spectrometry (AAS) 및 Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES)를 이용한 총 크롬 분석방법 비교 (Comparison of analytical methods for quantifying total chromium in soil using Atomic Absorption Spectrometer (AAS) and Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES))

  • 이홍길;김지인;변윤주;김현구;윤정기
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권6호
    • /
    • pp.22-28
    • /
    • 2017
  • The accuracy of analytical results in response to the use of different additives ($NH_4Cl$, KCl, $LaCl_3$) and oxidant gases was evaluated and compared by using Atomic Absorption Spectrometry (AAS). Identification of spectroscopic interferences and possible improvements in Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) analysis were also discussed. The average accuracies of total chromium using Certified Reference Materials (CRMs) were found to be 72.1~94.2% in air/acetylene flame condition by AAS, and they were improved to 100.5~110.5% when the oxidants was changed to nitrous oxide rather than adding the additives. The field samples showed similar trends to CRMs, but chromium concentrations were highly variable depending on analytical conditions. The average accuracies using CRMs were estimated to be 89.3~166.1% by ICP-AES, and improved to below 121.7% after eliminating iron interference. Field samples with low chromium and high iron concentration were measured to be > 30% lower in total chromium concentrations by ICP-AES than AAS in nitrous oxide/acetylene flame. Total chromium concentrations in soil could be analyzed with better accuracy under nitrous oxide/acetylene flame by AAS because it was more effective to increase the temperature of the flame than to eliminate the chemical interference for maximizing atomization of chromium. When using ICP-AES, interference substances, total chromium levels, and analytical conditions should be also considered.

SCS방법 및 회귀분석에 의한 유출 강우량 결정 (Determination of Effective Rainfall by US SCS Method and Regression Analysis)

  • 선우중호;윤용남
    • 물과 미래
    • /
    • 제10권2호
    • /
    • pp.101-111
    • /
    • 1977
  • The analysis performed here is aimed to increase the familiarity of hydrologic process especially for the small basins which are densely gaged. Kyung An and Mu Shim river basins are selected as a represectative basin according to the criteria which UNESCO has establisheed back in 1964 and being operated under the auspice of Ministry of Construction. The data exerted from these basins is utilized for the determination of the characteristics of precipitation and runoff phenomena for the small basin, which is considerred as a typical Korean samll watershed. The methodology developed by Soil Conservation Service, USA for determination of runoff value from precipitation is applied to find the suitability of the method to Korean River Basin. The soil cover complex number or runoff curve number was determined by considering the type of soil, soil cover, land use and other factor such as antecent moisture content. The averag values of CN for Kyung An and Mushim river basins were found to be 63.9 and 63.1 under AMC II, however, the values obtained from soil cover complex was less than those from total precipitation and effective precicpitation by 10-30%. It may be worth to note that an attention has to be paid in the application of SCS method lo Korean river basin by adjusting 10-30% increase to the value obtained from soil cover complex. Finally, the design flood hydrograph was consturcted by employing unit hydrograph technique to the dimensionless mass curve. Also a stepwise multiple regression was performed to find the relationship between runoff and API, evapotranspiration rate, 5 days antecedent precipitation and daily temperature.

  • PDF

기능성 고분자막을 이용한 반도체 공정 세정액의 분리정제특성( II ) (Separation Purification Characteristics of Rinsing Solution in Semiconductor Process using High Performance Polymer Membranes( II ))

  • 이재달;홍영기;노덕길;배기서
    • 한국염색가공학회지
    • /
    • 제17권4호
    • /
    • pp.21-26
    • /
    • 2005
  • A combination separation system is composed of three parts, simple microfiltration unit for the pretreatment of real waste IPA, pervaporation unit with plate and frame type module(the effective membrane area 9,040$cm^2$), and simple ultrafiltration unit as a refiner. Utrafiltration module with hollow fiber membrane(MWCO 10,000) used to purify waste aqueous IPA solution. In addition, the flux of $CMPA-K^+$ composite membrane for waste aqueous IPA solution was very steady-state with long experiment time(30 days). And the standard deviation($\sigma$) was 0.152 and then the coefficient of variation($CV\%$)was 10.82 The IPA concentration on the membrane performance using pervaporation module system could be increased from $89.85wt(\%)$ to more than $99.90wt\%$ in about 8hr at operation temperature of $70^{\circ}C$ using the pervaporation module system. Therefore, a combination separation process system of simple filtration and pervaporation was very effective for the purpose of the IPA purification and reuse front industrial electronic components cleaning process.

Aspergillus coreanus NR 15-1 과 Aspergillus oryzae NR 2-5의 원형질체 형성의 최적조건 (Optimal Conditions of Protoplast Formation of Aspergillus coreanus NR 15-1 and Aspergilus oryzae NR 2-5)

  • 정혁준;유대식
    • 한국미생물·생명공학회지
    • /
    • 제29권1호
    • /
    • pp.12-17
    • /
    • 2001
  • Aspergil-lus coreanus NR-15 and Aspergilus oryzae NR-2-5 from traditional Korean Nuruk were selected as parental strains producing starch hydrolysis enzyme. Xll(Arginine-) mutant from A. coreanus NR 15-1 showed high glu-doamylase activity and total acid productivity. Z6(Adenine-) mutant from A. oryzae NR2-5 showed the highest $\alpha$-amylase activity. Therefore, both XII and Z6 mutants were selected and investigated for the optimal conditions of protoplast formation for protoplast fusion. Mixture of equal amount of cellulase and driselase(10mg/ml each) was the most effective as lytic enzymes. The optimal pH and temperature for protoplast formation were 5.0 and $30^{\circ}C$, respectively. The most effective reaction for protoplast formation time was 4 hours. The maximum of protoplst for- mation of Xll mutant and Z6 mutant were $6.54$\times$10^{7}$ protoplasts/ ml and $3.04$\times$10^{ 7}$ protoplasts/ml, and the regen-eration frequencies of the protoplasts were 11.3% and 11.6%, respectively. The size of the protoplasts from X11 and Z6 mutants were 3~6 $\mu\textrm{m}$ and 4~9$\mu\textrm{m}$, respectively.

  • PDF

DAF 슬러지의 부상식 농축; 고형물 플럭스법 적용과 영향인자 (Thickening of Sludge from DAF process by Flotation; Application of Solid Flux Theory and Effective Factors)

  • 박상철;한무영;독고석;권순범
    • 상하수도학회지
    • /
    • 제20권4호
    • /
    • pp.617-626
    • /
    • 2006
  • Compared with the sludge from gravity sedimentation, it is difficult for operations to settle the sludge occurred from dissolved-air-flotation (DAF). Even though there are some problems in treating DAF sludge with conventional gravity thickeners, those has been used until now. In this study, Solid Flux theory for gravity thickening was applied to the Solid Flux of DAF sludge through flotation in order to develop new methodology for treatment of DAF sludge. Also, characteristics of DAF sludge were investigated. From the experiment results, it was revealed that the higher the polymer dosage, at fixed the solid concentration, the greater the rising velocity becomes. When we applied solid flux theory, the relationship, which is similar to that of gravity thickening, has been achieved. Also, we could find the proper polymer dosage from the rising velocity is about 50 mg/L. Consequently, the limiting solid flux can be derived from the relationship between the total solid flux and the withdrawal velocity of DAF sludge. Furthermore, the factors, such as solid concentrations, bubble volume, pH, zeta potential, and temperature, have effects on the flotation and sedimentation for DAF sludge treatment.