• Title/Summary/Keyword: Total Pressure Recovery

Search Result 140, Processing Time 0.029 seconds

Solar tower combined cycle plant with thermal storage: energy and exergy analyses

  • Mukhopadhyay, Soumitra;Ghosh, Sudip
    • Advances in Energy Research
    • /
    • v.4 no.1
    • /
    • pp.29-45
    • /
    • 2016
  • There has been a growing interest in the recent time for the development of solar power tower plants, which are mainly used for utility scale power generation. Combined heat and power (CHP) is an efficient and clean approach to generate electric power and useful thermal energy from a single heat source. The waste heat from the topping Brayton cycle is utilized in the bottoming HRSG cycle for driving steam turbine and also to produce process steam so that efficiency of the cycle is increased. A thermal storage system is likely to add greater reliability to such plants, providing power even during non-peak sunshine hours. This paper presents a conceptual configuration of a solar power tower combined heat and power plant with a topping air Brayton cycle. A simple downstream Rankine cycle with a heat recovery steam generator (HRSG) and a process heater have been considered for integration with the solar Brayton cycle. The conventional GT combustion chamber is replaced with a solar receiver. The combined cycle has been analyzed using energy as well as exergy methods for a range of pressure ratio across the GT block. From the thermodynamic analysis, it is found that such an integrated system would give a maximum total power (2.37 MW) at a much lower pressure ratio (5) with an overall efficiency exceeding 27%. The solar receiver and heliostats are the main components responsible for exergy destruction. However, exergetic performance of the components is found to improve at higher pressure ratio of the GT block.

Effects of Resting Periods Between Exercise Sets During Isokinetic Exercise on Muscle Performances and Physiological Variables in Middle-aged Women (중년여성에서 등속성 운동 시 세트간의 휴식시간이 등속성 근기능 및 생리적 변인에 미치는 영향)

  • Choi, Bo-Sung;Han, Sang-Wan
    • Physical Therapy Korea
    • /
    • v.8 no.3
    • /
    • pp.77-95
    • /
    • 2001
  • The purpose of this study was to investigate the effects of resting periods between exercise sets during isokinetic contraction on recovery from muscle fatigue, strength, heart rate, blood pressure, and lactate level. Sixteen women performed 10 repetitions of isokinetic exercise for three sets in three different conditions. During the sets, they rested 50, 100, and 150 seconds in each condition. And the results were: 1) In this population, the peak torque of extensor during the isokinetic exercise in 100 second resting condition was significantly higher than that in 50 and 150 second resting conditions (p<.01). The total work of extensor was significant in the second and third sets in 50 and 100 second resting conditions (p<.01). 2) During the isokinetic exercise, the heart rate was progressively increased as the sets were advanced in all resting conditions (p<.01). And the increase was significant during the second and third sets than the first in 50 second resting condition (p<.01), while it was significantly greater after the third set than the first in 100 and 150 second resting conditions (p<.01). 4) No difference was found between the resting periods in blood lactate level and blood pressure during the isokinetic exercise. However, differences were found between the sets in these variables (p<.01).

  • PDF

Effect of Height Variation of Recirculating Casing Treatment on the Performance of a Turbocharger Compressor (재순환케이싱처리 높이변화가 터보차저 압축기의 성능에 미치는 영향)

  • Nguyen, Van Hap;Zhou, Tianjun;Lee, Geun Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.8
    • /
    • pp.669-675
    • /
    • 2015
  • In this study, we investigate the performance variations of an automotive turbocharger compressor with respect to the height variation of the recirculating casing treatment (RCT). We use three RCT heights, namely 1.2 mm, 1.5 mm, and 1.8 mm. We vary the compressor speed from 90,000 to 150,000 rpm, and the flow rate from 0.015 kg/s to 0.08 kg/s. The calculation results of the total pressure ratio and isentropic efficiency showed good agreement with the performance data provided by the manufacturer within a 0.7 percent error. The results showed that the RCT heights of 1.2 mm, 1.8 mm, and 1.5 mm, in that order, exhibited a more uniform pressure distribution, higher pressure ratio, and wider operational range. As the number of revolutions per minute increased, we obtained typical characteristics of a compressor map having a narrower operational range in the region of higher pressure ratio.

Performance of fouled NF membrane as used for textile dyeing wastewater

  • Abdel-Fatah, Mona A.;Khater, E.M.H.;Hafez, A.I.;Shaaban, A.F.
    • Membrane and Water Treatment
    • /
    • v.11 no.2
    • /
    • pp.111-121
    • /
    • 2020
  • The fouling of Nanofiltration membrane (NF) was examined using wastewater containing reactive black dye RB5 of 1500 Pt/Co color concentrations with 16890 mg/l TDS collected from El-alamia Company for Dying and Weaving in Egypt. The NF-unit was operated at constant pressure of 10 bars, temperature of 25℃, and flowrate of 420 L/min. SEM, EDX, and FTIR were used for fouling characterization. Using the ROIFA-4 program, the total inorganic fouling load was 1.07 mM/kg present as 49.3% Carbonates, 10.1% Sulfates, 37.2% Silicates, 37.2% Phosphates, and 0.93% Iron oxides. The permeate flux, recovery, salt rejection and mass transfer coefficients of the dye molecules were reduced significantly after fouling. The results clearly demonstrate that the fouling had detrimental effect on membrane performance in dye removal, as indicated by a sharp decrease in permeate flux and dye recovery 68%. The dye mass transfer coefficient was dropped dramatically by 34%, and the salt permeability increased by 14%. In this study, all the properties of the membrane used and the fouling that caused its poor condition are identified. Another study was conducted to regeneration fouled membrane again by chemical methods in another article (Abdel-Fatah et al. 2017).

Thermodynamic analysis of a combined gas turbine power plant with a solid oxide fuel cell for marine applications

  • Welaya, Yousri M.A.;Mosleh, M.;Ammar, Nader R.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.5 no.4
    • /
    • pp.529-545
    • /
    • 2013
  • Strong restrictions on emissions from marine power plants (particularly $SO_x$, $NO_x$) will probably be adopted in the near future. In this paper, a combined solid oxide fuel cell (SOFC) and gas turbine fuelled by natural gas is proposed as an attractive option to limit the environmental impact of the marine sector. It includes a study of a heat-recovery system for 18 MW SOFC fuelled by natural gas, to provide the electric power demand onboard commercial vessels. Feasible heat-recovery systems are investigated, taking into account different operating conditions of the combined system. Two types of SOFC are considered, tubular and planar SOFCs, operated with either natural gas or hydrogen fuels. This paper includes a detailed thermodynamic analysis for the combined system. Mass and energy balances are performed, not only for the whole plant but also for each individual component, in order to evaluate the thermal efficiency of the combined cycle. In addition, the effect of using natural gas as a fuel on the fuel cell voltage and performance is investigated. It is found that a high overall efficiency approaching 70% may be achieved with an optimum configuration using SOFC system under pressure. The hybrid system would also reduce emissions, fuel consumption, and improve the total system efficiency.

Effects of the addition of low-dose ketamine to propofol anesthesia in the dental procedure for intellectually disabled patients

  • Hirayama, Akira;Fukuda, Ken-ichi;Koukita, Yoshihiko;Ichinohe, Tatsuya
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.19 no.3
    • /
    • pp.151-158
    • /
    • 2019
  • Background: This study aimed to examine whether the combination of low-dose ketamine and propofol in deep sedation is clinically useful in controlling the behavior in intellectually disabled patients who are typically extremely noncooperative during dental procedures. Methods: A total of 107 extremely noncooperative intellectually disabled adult patients were analyzed. In all patients, deep sedation was performed using either propofol alone (group P) or using a combination of propofol and 0.2 mg/kg or 0.4 mg/kg ketamine (groups PK0.2 and PK0.4, respectively). The procedures were performed in the order of insertion of nasal cannula into the nostril, attachment of mouth gag, and mouth cleaning and scaling. The frequency of patient movement during the procedures, mean arterial pressure, heart rate, peripheral oxygen saturation, recovery time, discharge time, and postoperative nausea and vomiting were examined. Results: The three groups were significantly different only in the frequency of patient movement upon stimulation during single intravenous injection of propofol and scaling. Conclusion: For propofol deep sedation, in contrast to intravenous injection of propofol alone, prior intravenous injection of low-dose ketamine (0.4 mg/kg) is clinically useful because it neither affects recovery, nor causes side effects and can suppress patient movement and vascular pain during procedures.

Exhaust-Gas Heat-Recovery System of Marine Diesel Engine (I) - Energy Efficiency Comparison for Working Fluids of R245fa and Water - (선박용 디젤엔진의 배기가스 열회수 시스템 (I) - R245fa 및 Water 의 작동유체에 대한 에너지효율 비교 -)

  • Choi, Byung-Chul;Kim, Young-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.3
    • /
    • pp.293-299
    • /
    • 2012
  • The thermodynamic efficiency characteristics of R245fa and water as working fluids have been analyzed for the electricity generation system applying the Rankine cycle to recover the waste heat of the exhaust gas from a diesel engine for the propulsion of a large ship. The theoretical calculation results showed that the cycle, system, and total efficiencies were improved as the turbine inlet pressure was increased for R245fa at a fixed mass flow rate. In addition, the net work rate generated by the Rankine cycle was elevated with increasing turbine inlet pressure. In the case of water, however, the maximum system efficiencies were demonstrated at relatively small ratios of mass flow rate and turbine inlet pressure, respectively, compared to those of R245fa. The optimized values of the net power of the cycle, system efficiency, and total efficiency for water had relatively large values compared to those of R245fa.

Shape Optimization of High Power Centrifugal Compressor Using Multi-Objective Optimal Method (다목적 최적화 기법을 이용한 고출력 원심압축기 형상 최적설계)

  • Kang, Hyun Su;Lee, Jeong Min;Kim, Youn Jea
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.5
    • /
    • pp.435-441
    • /
    • 2015
  • In this study, a method for optimal design of impeller and diffuser blades in the centrifugal compressor using response surface method (RSM) and multi-objective genetic algorithm (MOGA) was evaluated. A numerical simulation was conducted using ANSYS CFX with various values of impeller and diffuser parameters, which consist of leading edge (LE) angle, trailing edge (TE) angle, and blade thickness. Each of the parameters was divided into three levels. A total of 45 design points were planned using central composite design (CCD), which is one of the design of experiment (DOE) techniques. Response surfaces that were generated on the basis of the results of DOE were used to determine the optimal shape of impeller and diffuser blade. The entire process of optimization was conducted using ANSYS Design Xplorer (DX). Through the optimization, isentropic efficiency and pressure recovery coefficient, which are the main performance parameters of the centrifugal compressor, were increased by 0.3 and 5, respectively.

Negative Pressure Aspiration of Spontaneous Intracerebral Hematoma (자발성 뇌내혈종의 음압배액술)

  • Kim, Il-Man;Son, Eun Ik;Kim, Dong Won;Yim, Man Bin
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.6
    • /
    • pp.738-743
    • /
    • 2000
  • Objectives : The less invasive stereotactic surgery of hypertensive intracerebral hematoma has been preferred. Many techniques were developed to facilitate aspiration of a dense blood clot in acute stage. Authors describe a method for evacuation of putaminal hematoma via computerized tomography(CT)-aided free-hand stereotactic infusion of urokinase and frequent negative pressure aspiration. Patients and Methods : A total of ten patients with spontaneous putaminal hematoma underwent surgery with negative pressure aspiration in the three-year period. All procedures were performed within 12 hours of insult. A silicone ventricular catheter was inserted into the center of hematoma through a burr hole at the Kocher's point under local anesthesia. In a typical case of putaminal hematoma, the trajectory of catheter was pointed the center of hematoma parallel to sagittal plane vertically and the external auditory meatus posteriorly. Immediately after the first trial of hematoma aspiration low-dose urokinase solution(2,000IU/5ml saline) was administrated through the catheter and drain was clipped for 30 minutes. Subsequently, the partially liquified hematoma was manually aspirated using a 10ml syringe with a negative pressure of less than 2 to 3ml. The procedure was carefully repeated every 1 hour until the hematoma was near totally evacuated. Results : The patients population consisted composed of 4 men and 6 women with a mean age of 61.6 years. All had major neurological deficits preoperatively. The mean hematoma volume was 44.3 ml and hematoma was drained for 20 to 48 hours. No complications such as rebleeding, meningitis, or malplaced catheter were noted. Outcome was moderately disabled in four patients and good recovery in three patients. Conclusion : Although the frequent negative pressure aspiration and low-dose urokinase infusion has the disadvantage of possbility of rebleeding and infection, it is consisdered to be an effective method because it allows a simple, safe, and complete removal of hematoma.

  • PDF

Developing Liquid Cooling Garments to Alleviate Heat Strain of Workers in Summer and Exploring Effective Cooling Temperature and Body Regions (여름철 작업자들의 고체온증 예방을 위한 액체냉각복 개발 및 효과적인 냉각온도와 인체 냉각부위 탐색)

  • Jung, Jae-Yeon;Kang, Juho;Seol, Seonhong;Lee, Joo-Young
    • Fashion & Textile Research Journal
    • /
    • v.22 no.2
    • /
    • pp.250-260
    • /
    • 2020
  • The purpose of the present study was to explore the most effective body region and cooling temperature to alleviate heat strain of workers in hot environments. We developed liquid cooling hood, vest, sleeves and socks and applied the water temperatures of 10, 15, 20, and 25℃ through the liquid cooling garments in a hot and humid environment (33℃ air temperature and 70% RH air humidity). A healthy young male participated in a total of 16 experimental trials (four cooling garments × four cooling temperatures) with the following protocol: 10-min rest, 40-min exercise on a treadmill and 10-min recovery. The results showed that rectal temperature, mean skin temperature, and ratings of perceived exertion during exercise; heart rate and diastolic blood pressure during recovery; and total sweat rate were lower for the vest condition than other garment conditions(p < .05). However, there was no differences in mean skin temperature among the four cooling garments when we compared the values converted by covering area(%BSA). When we classified the results by cooling temperature, there were no consistent differences in thermoregulatory and cardiovascular responses among the four temperatures, but 25℃ water temperature was evaluated as being the most ineffective cooling temperature in terms of subjective responses. In conclusion, the results indicated that wearing cooling vest with < 20℃ cooling temperature can alleviate heat strain of workers in hot and humid environments. If the peripheral body regions are cooled with liquid cooling garments, larger cooling area with lower cooling temperature than 10℃ would be effective to reduce heat strain of workers. Further studies with a vaild number of subjects are required.