• Title/Summary/Keyword: Total Cr

Search Result 859, Processing Time 0.03 seconds

Adsorption isotherm and kinetics analysis of hexavalent chromium and mercury on mustard oil cake

  • Reddy, T. Vishnuvardhan;Chauhan, Sachin;Chakraborty, Saswati
    • Environmental Engineering Research
    • /
    • v.22 no.1
    • /
    • pp.95-107
    • /
    • 2017
  • Adsorption equilibrium and kinetic behavior of two toxic heavy metals hexavalent chromium [Cr(VI)] and mercury [Hg(II)] on mustard oil cake (MOC) was studied. Isotherm of total chromium was of concave type (S1 type) suggesting cooperative adsorption. Total chromium adsorption followed BET isotherm model. Isotherm of Hg(II) was of L3 type with monolayer followed by multilayer formation due to blockage of pores of MOC at lower concentration of Hg(II). Combined BET-Langmuir and BET-Freundlich models were appropriate to predict Hg(II) adsorption data on MOC. Boyd's model confirmed that external mass transfer was rate limiting step for both total chromium and Hg(II) adsorptions with average diffusivity of $1.09{\times}10^{-16}$ and $0.97m^2/sec$, respectively. Desorption was more than 60% with Hg(II), but poor with chromium. The optimum pH for adsorptions of total chromium and Hg(II) were 2-3 and 5, respectively. At strong acidic pH, Cr(VI) was adsorbed by ion exchange mechanism and after adsorption reduced to Cr(III) and remained on MOC surface. Hg(II) removal was achieved by complexation of $HgCl_2$ with deprotonated amine ($-NH_2$) and carboxyl (COO-) groups of MOC.

Structural transition of Ti-Cr-V alloys with hydrogenation and dehydrogenation and the improvement of their hydrogen storage properties by heat treatment (Ti-Cr-V 합금의 수소화-탈수소화에 따른 상천이 및 열처리에 의한 수소저장특성의 향상)

  • You, Jeong-Hyun;Cho, Sung-Wook;Shim, Gun-Choo;Choi, Good-Sun;Park, Choong-Nyeon;Choi, Jeon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.2
    • /
    • pp.125-132
    • /
    • 2006
  • The alloys which compositions were represented by the formula, $Ti_{(0.22+X)}Cr_{(0.28+1.5X)}V_{(0.5-2.5X)}$ ($0{\leq}X{\leq}0.12$), had the total hydrogen storage capacity higher than 3 wt% and the effective hydrogen storage capacity higher than 1.4 wt%. Particularly, among all the tested alloys, the $Ti_{0.32}Cr_{0.43}V_{0.25}$ alloy exhibited the best effective hydrogen storage capacity of 1.65 wt%. Furthermore, the reversible bcc${\leftrightarrow}$fcc structural transition was observed with hydrogenation and dehydrogenation, which predicted the possibility of pressure cycling. EDS analysis revealed micro-segregation, which suggested the necessity of microstructure homogenization by heat treatment. The $Ti_{0.32}Cr_{0.43}V_{0.25}$ alloy was selected for heat treatment and for other related studies. The results showed that the total and the effective hydrogen storage capacity increased to 3.7 wt% and 2.3 wt%, respectively. The flatness of the plateau region was also greatly improved and heat of hydride formation was determined to be approximately -36 kJ/mol $H_2$.

Efficacy of Cr (III) Supplementation on Growth, Carcass Composition, Blood Metabolites, and Endocrine Parameters in Finishing Pigs

  • Wang, M.Q.;He, Y.D.;Lindemann, M.D.;Jiang, Z.G.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.10
    • /
    • pp.1414-1419
    • /
    • 2009
  • The study was conducted to evaluate the effects of trivalent chromium from different sources on growth, carcass composition, and serum parameters in finishing pigs. Ninety-six crossbred pigs with an initial average body weight of 65.57${\pm}$1.05 kg were blocked by body weight and randomly assigned to four treatments with three replicates. Pigs were offered one of four diets including a control diet or the control diet supplemented with 200 ${\mu}g/kg$ chromium from either chromium chloride ($CrCl_{3}$), chromium picolinate (CrPic) or chromium nanocomposite (CrNano) for 40 days. After completion of the feeding trial, eight pigs from each treatment were selected to collect blood samples, and slaughtered to measure carcass composition. The results showed that supplemental chromium had no significant effect on growth performance, while CrNano increased carcass lean proportion and loin Longissimus muscle area (p<0.05), and decreased carcass fat proportion and 10th rib backfat depth (p<0.05). CrPic supplementation also resulted in lower fat proportion and larger Longissimus muscle area (p<0.05). The addition of Cr from CrNano or CrPic decreased serum glucose (p<0.05) and increased concentrations of total protein and free fat acid in serum (p<0.05). Serum urea nitrogen, triglyceride and cholesterol were decreased (p<0.05), and serum high density lipoprotein and lipase activity were increased (p<0.05) with the supplementation of CrNano. Serum insulin was decreased (p<0.05) by supplemental Cr from CrNano or CrPic, and serum insulin-like growth factor I was increased significantly in the CrNano treated group. These results suggest that chromium nanocomposite has higher efficacy on carcass composition in pigs compared to the traditional chromium sources.

Effects of Dietary Chromium Picolinate Supplementation on Growth Performance and Immune Responses of Broilers

  • Lee, Der-Nan;Wu, Fu-Yu;Cheng, Yeong-Hsiang;Lin, Rong-Shinn;Wu, Po-Ching
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.2
    • /
    • pp.227-233
    • /
    • 2003
  • Two experiments were conducted to evaluate the effects of chromium (Cr) on the growth performance, bone trait, serum traits, and immune responses in broilers. The broilers were fed corn-soybean meal basal diet supplemented with Cr at level of 0(control), 200, 400, or 800 ppb in the form of chromium picolinate (CrPic). The broilers were fed treated diets for 6 weeks in Exp. 1, but the Cr supplement was removed for the last 3 weeks in Exp. 2. Exp. 1 showed that dietary supplement of Cr did not affect growth performance of the broiler, though improved feed efficiency (p<0.05) was observed during 0 to 3 weeks. Moreover, serum total (p<0.05) and HDL cholesterols (p<0.06) were significantly higher in pooled Cr added group at 6 weeks of age, however, the difference was not significant in Exp. 2. The pooled Cr added group in Exp.1 had significantly lower (p<0.05) alkaline phosphatase activity and higher (p<0.09) calcium at 3 weeks. Significantly lower phosphorus was also observed in Exp. 2. With continued supplement of Cr as in Exp. 1, the alkaline phosphatase activity maintained higher at 6 weeks, as opposed to significantly lower in Exp. 2, which had no further Cr supplement. Higher bone breaking strength was observed in 400 ppb Cr supplemented in Exp. 1, though not significantly different. Serum glucose and triglyceride were not affected by Cr supplement. Antibody against Infectious Bronchitis (IB) was significantly (p<0.05) higher with 400 ppb Cr supplemented, and anti-Newcastle disease (ND) antibody also tended to be higher (p<0.06) in pooled Cr added group at 6 weeks of age in Exp. 1. Peripheral blood blastogenesis activity was not different among the treatments. The results suggest that diet supplemented with 400 ppb CrPic may be beneficial to the broiler.

Recirculating Integrated System for the Treatment of Authentic Integrated-textile-dyeing Wastewater from Dyeing Industrial Complex (염색산업단지 종합폐수처리용 재순환 통합시스템)

  • Lee, Eun Ju;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.55 no.6
    • /
    • pp.837-845
    • /
    • 2017
  • A recirculating integrated system composed of a fluidized biofilter filled with waste-tire crumb media fixed with return sludge from wastewater treatment facility of D dyeing industrial center, and a UV/photocatalytic reactor packed with calcined $TiO_2$ coated-glass beads as photocatalyst-support, was constructed and was run to treat authentic textile-dyeing wastewater from D-dyeing industrial center, which was mixed with an alkaline polyester-weight-reducing wastewater and a wastewater from sizing process. As a result, its total removal efficiency(RE(tot)) of $COD_{cr}$ and colors were ca. 81% and 55%, respectively. The synergy effect of the recirculating integrated system to enhance total removal efficiency(RE(tot)) of $COD_{cr}$ and colors were evaluated at most ca. 7% and 3%, respectively. The fluidized biofilter and the UV/photocatalytic reactor were responsible for ca. 94% and 6% of the total $COD_{cr}$ removal efficiency, respectively, and were also responsible for ca. 86% and 14% of the total color-removal efficiency, respectively. Thus, the degree of the UV/photocatalytic reactor-unit process's contribution to RE(tot) of color, was about 2.4 times of that to RE(tot) of $COD_{cr}$. Therefore, the UV/photocatalytic reactor facilitated the more effective elimination of colors by breaking down the chemical bonds oriented from colors of dyes such as azo-bond, than $COD_{cr}$. In addition, the effect of the removal efficiency of each unit process(i.e., the fluidized biofilter or the UV/photocatalytic reactor) of the recirculating integrated system on RE(tot) of $COD_{cr}$ and colors, was analysed by establishing its model equation with an analytic correlation.

Reduction of Hexavalent Chromium Collected on PVC Filters in Field Electroplating Process (현장 도금 공정에서 PVC 여과지에 채취된 6가 크롬의 환원)

  • Shin Yong Chul;Paik Nam Won;Yi Gwang Yong;Lee Byung Kyu;Lee Ji Tae
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.1
    • /
    • pp.41-49
    • /
    • 2002
  • Recently, pilot studies showed an evidence of reduction of airborne hexavalent chromium, Cr(VI), on PVC filter during air sampling and storage. However, the information on this in the field was limited. Thus, we studied the reduction behaviors of airborne Cr(VI) on PVC filters during sampling and storage at three field electroplating operations. Regression between sampling time and the reduction (ratio of Cr(VI) to total Cr concentrations) was not statistically significant (p>0.05). However, the reductions in samples collected for 240 ~ 340 minutes were significantly higher than those for 30 - 60 minutes. On the other hand, another experiment showed a good correlation (r=0.96) between sampling time and the reduction without an exceptional value. Storage temperature was not a factor affecting the reduction of Cr(VI) collected on PVC filter. The loss of Cr(VI) samples stored in alkali solution (2% NaOH/3% Na$_2$CO$_3$) was significantly lower than that stored in vial according to NIOSH method (p<0.05). Thus, dipping Cr(VI) samples into alkali solution was a storage method to minimize tile reduction.

On the Outage Behavior of Interference Temperature Limited CR-MISO Channel

  • Kong, Hyung-Yun;Asaduzzaman, Asaduzzaman
    • Journal of Communications and Networks
    • /
    • v.13 no.5
    • /
    • pp.456-462
    • /
    • 2011
  • This paper investigates the outage behavior of peak interference power limited cognitive radio (CR) networks with multiple transmit antennas. In CR-multi-input single-output (MISO) channel, the total transmit power is distributed over the transmitantennas. First, we use the orthogonal space-time codes (STC) to achieve the transmit diversity at CR-receiver (rx) and investigate the effect of the power distribution on the interference power received at the primary-receiver (P-rx). Then, we investigate the transmit antenna selection (TAS) scheme in which the CR system selects the best transmit antenna and allocates all the power to the selected best antenna. Two transmit antenna selection strategies are proposed depending on if feedback channel is available or not. We derive the closed form expressions of outage probability and outage capacity of all schemes with arbitrary number of transmit-antennas. We show that the proposed schemes significantly improve the outage capacity over the single antenna systems in Rayleigh fading environment. We also show that TAS based scheme outperforms the STC based scheme when peak interference power constraint is imposed on the P-rx only if a feedback channel from CR-rx to CR-transmitter is available.

Stress Analysis of Total Knee System Depending on Implant Materials and Fixation Methods (인공무릎관절에 있어서 임플란트의 재료 및 고정방법에 따른 응력분석)

  • Cho, C.H.;Cho, Y.K.;Choi, J.B.;Choi, K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.484-488
    • /
    • 1997
  • Three-dimensional finite element analyses were used to compare the stress distribution and the stability of the fixation among seven different tibial components and to investigate the effect due to implant materials in total knee arthroplasty. The components included an intact tibia(Type I), Cemented Cobalt-Chromium tibial tray implanted with a PMMA cemented Co-Cr stem(Type II), Cemented Co-Cr tibial tray with a uncemented Co-Cr stem(Type III), Cemented Ultra High Molecular Weight Polyethylene (UHMWPE) tibial tray with a cemented UHMWPE stem (Type IV), Cemented UHMWPE tray with a uncemented UHMWPE stem(Type V), Cemented Co-Cr tray without a stem(Type VI), and Cemented UHMWPE tray without a stem(Type VII). Uncemented components were assumed to have complete bony in growth and a rigid state of fixation between component and bone. The interface between bone/cement/component of cemented components was also assumed to be fully bonded. Bi-condylar forces were applied. The results indicated that Uncemented stem components provided lower bone stress shielding and stress concentration. The UHMWPE tray and stem component showed better agreement with the intact tibia than the Co-Cr Alloy tray and stem components. If the implant tray can be fixed firmed without a stem, Cemented PE tray without a stem(Type VII) may be recommended to give the best characteristics in the sense of stress distribution and stability.

  • PDF

Relationship between Serum Levels of Microminerals and Lipids in Korean Adults on Self-Selected Diet (정상 성인의 혈중 미량무기질과 지질과의 관련성에 관한 연구-충남지역 일부 여대생의 혈중 As, Cr, Mn, Se, Ni을 중심으로-)

  • 최미경
    • Korean Journal of Community Nutrition
    • /
    • v.5 no.2
    • /
    • pp.289-296
    • /
    • 2000
  • The purpose of this study was to investigate the relationship and lipids in healthy adults on self-selected diets. These subjects consisted of 40 female college students residing in Chungnam. Anthropometric measure-ments, diet intake measurements, and blood collection were conducted. Serum concentrations of 5 microminerals(As, Cr, Mn, Se, Ni), lipids(triglyceride, total cholesterol, HDL-cholesterol), and glucose were measured by an ICP spectrometer and biochemical analyzer. The results were as follows. The mean age of the subjects was 22.34 years and the mean weight, height, and BMI were 52.89kg, 161.29cm and 20.34, respectively. The mean serum concentrations appeared to be 14.60ug/dl(As), 1.87ug/dl(Cr), 0.18ug/dl(Mn), 23.50ug/dl(Se), 0.21ug/dl(Ni), 60.73mg/dl(triglyceride), 138.49mg/dl(total cholesterol), 65.95mg/dl(HDL-cholesterol), 60.39mg/dl(LDL-cholesterol) and 88.82mg/dl(glucose). When analyzed by Pearson’s correlation coefficient, the serum concentration of Cr was negatively correlated with Ca and vitamin B12 intake(p〈0.05, p〈0.05) respectively, Mn was negatively correlated with Na intake(p〈0.05), Ni, however, was positively correlated with K intake(p〈0.05). The serum concentration of Se was positively correlated with LDL-cholesterol(p〈0.05), Ni, however, negatively correlated with total cholesterol, HDL-cholesterol, LDL-cholesterol, and glucose, respectively(p〈0.001, p〈0.01, p〈0.05). Further studies are needed to clarify the precise micromineral intakes, nutritional assessment of microminerals, and cause-effect relation of microminerals and serum lipids.

  • PDF

Magnetic Properties of Cr Substituted SiTe Compounds (SiTe에 Cr을 치환한 화합물의 자기적 성질)

  • Landge, Kalpana;Bialek, Beata;Lee, Jae-Il
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.4
    • /
    • pp.127-131
    • /
    • 2011
  • In this paper, we study the electronic and magnetic properties of Cr substituted SiTe in the rock-salt structure compound using the full potential linearized augmented plane wave method within the generalized gradient approximation to the exchange correlation potential. Two stoichiometries are studied: $CrSi_3Te_4$ with 25 %, and $CrSiTe_2$ with 50 % Cr substitution. We found, from the total energy calculations, that the equilibrium lattice constant for cubic $CrSi_3Te_4$ is 11.64 a.u. and a = 7.89 a.u. and c = 11.13 a.u. for tetragonal $CrSiTe_2$. The integer value of the calculated magnetic moment per unit cell, $4{\mu}_B$ for $CrSiTe_2$ suggests that this compound is halfmetallic. The magnetic moment per unit cell for $CrSi_3Te_4$ is slightly larger than $4{\mu}_B$. The magnetic moment on Cr atoms are 3.61 and $3.62{\mu}_B$ in the $CrSi_3Te_4$ and $CrSiTe_2$, respectively. The presence of Cr atoms causes that the other atoms become slightly magnetized in both compounds. The electronic properties and the magnetism are discussed with the calculated spin-polarized density of states.