• 제목/요약/키워드: Torque standard

검색결과 141건 처리시간 0.03초

문서세단기 성능평가방법의 표준화에 관한 연구 (A Study on Standard of Performance Evaluation for Paper Shredder)

  • 이동규;유송민;이위로;노대호;김민호
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 추계학술대회 논문집
    • /
    • pp.122-127
    • /
    • 2004
  • The purpose of this study is to introduce the standard of the durability and evaluation method for paper shredder. The major evaluation criteria include shredding capability, shredding blade (or cutter) hardness and edge roughness, and durability. Due to the difficulties in assessing the durability directly, performance deterioration of the shredder was assessed by measuring the torque variation along with the variation in shredded chip size and load, thereby proposing the indirect method of assessing the paper shredder durability.

  • PDF

Fast(submillisecond) Switching of Nematic Liquid Crystals and Effects of Dielectric Dispersion; Theory and Experiment

  • Shiyanovskii, Sergij V.;Golovin, Andrii B.;Yin, Ye;Lavrentovich, Oleg D.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.181-186
    • /
    • 2005
  • We demonstrate that the finite rate of dielectric relaxation in liquid crystals which has been ignored previously causes profound effects in the fast dielectric reorientation of the director. The phenomenon is relevant for submillisecond switching of the director when the switching rate approaches the rate of dielectric relaxation through the reorientation of the molecular dipoles. A submillisecond switching ($15-400\;{\mu}s$ for an optical retardation shift $0.3-2.2\;{\mu}m$ in $10-15\;{\mu}m$ thick cells) is demonstrated for dual frequency nematic cells with high pretilt that maximizes the dielectric torque acting on the director. We propose the theory of dielectric response in which the electric displacement depends not only on the present (as in the standard theory) but also on the past values of electric field and director. We design an experiment in which the standard "instantaneous" model and our model predict effects of opposite signs; the experimental data support the latter model.

  • PDF

일반 및 고효율 유도 전동기의 특성 비교 해석 (Characteristic Comparison Analysis for Standard and High-Efficiency Induction Motor)

  • 김종겸
    • 전기학회논문지P
    • /
    • 제56권4호
    • /
    • pp.186-190
    • /
    • 2007
  • This paper presents an analysis on the power characteristics of standard and high-efficiency induction motor. The parameter of induction motor play an important role in the expression of machine's performance characteristics. Induction motor can be differently found its characteristics parameters with the operation under the same capacity. So it is very difficult to detect correct parameter of induction motor. For the analysis, we discovered the motor parameters by the technical program with nameplate data. In this paper, we analyzed that how power and torque characteristics of induction motor would be changed for two kinds of motor parameters.

조도 변화가 여성노인의 보행 표준시간과 하지 관절파워에 미치는 영향 (Effect of Standard Time and Joint Power of Lower Extremity on Different Illuminations in the Elderly Women)

  • 하종규;이재훈;양정훈;서욱현
    • 한국운동역학회지
    • /
    • 제24권2호
    • /
    • pp.167-172
    • /
    • 2014
  • The purpose of this study was to investigate walking standard time and joint powers of the lower extremities on the changes of illuminations in the elderly women. Ten older women ($70.90{\pm}3.28$ years, $154.70{\pm}3.47$ cm, $53.80{\pm}5.39$ kg) with normal vision and no gait disabilities participated in this study. All the experiments were performed on a level walkway from low to high lighting (six conditions). A 3-dimensional motion capturing system, force-plate, and EMG were used to acquire and analyze walking motion, force, and muscle activity data; the sampling frequency was 100 Hz, 1000 Hz and 1000 Hz respectively. To test the differences on walking standard time and joint powers of the lower extremities between the six lighting conditions, one-way repeated ANOVAs were evaluated. The following results were drawn: First, mean standard time was about 1.3 sec/stride, and velocities were smaller with lighting increasing except 100 Lx. Second, the joint power patterns of ankle and knee were not consistent, but only hip joint power was a greatest in 6 Lx and a smallest in 400 Lx. Third, standard times(100 Lx<300 Lx, 400 Lx) were statistically significant, and hip joint max powers (100 Lx>others) were also statistically significant. But ankle and knee joint max power were not statistically significant. These results showed that standard times from low to high lighting were not consistent, and hip joint of 100 Lx has a greatest rotational torque. We suggested that gait strategies of them as to changing illuminations were not consistent and findings may represent a lack of adaptability in the elderly women.

보철물 조건에 따른 Periotest수치의 실험적 평가 (IN VITRO EVALUATION OF PERIOTEST VALUES UNDER VARIOUS CONDITIONS OF PROSTHESES)

  • 한중석
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.793-800
    • /
    • 1997
  • Periotest(Siemens, Germany) has been used to test mobility of the implants clinically, however the effects of target materials and connection methods on the PTVs(Periotest Values) have not been evaluated. Periotest has been regarded as a reliable and objective tool to test implant and natural teeth mobility clinically, however this instrument showed different PTVs under various test conditions. This in vitro study was designed to compare PTVs of different veneering materials and prosthodontic designs (single and bridge restorations). To compare the effects of veneering materials on PTVs, 1 mm thickness of five different testing materials (porcelain, type III gold alloy, pure titanium, composite resin, acrylic resin) were placed on the resin block. Three full length of 13 mm Mark II implant fixtures were embedded into autopolymerizing resin block to fabricate single and bridge restorations. To evaluate effects of the connection method in single restorations, PTVs of screw retained(UCLA type) and cementation type(Cera-One system) were compared. Finally, to test reliability of PTVs of the final restorations, screw retained three unit short span PFM bridges were fabricated on the standard and Estheti-Cone abutments. All testing components were tightened with torque controller and PTVs of all specimens were measured 15 times for statistical analysis with SAS program. Following conclusions were made within the limit of this in vitro study. 1. PTVs of type III gold alloy, grade II titanium, composite resin veneering materials showed no significant differences, however acrylic resin and porcelain showed significant differences (P<0.05). 2. Single tooth restorations showed consistent PTVs as long as proper torque force was applied. 3. PTVs of bridge type prostheses was inconsistent regardless of abutment types. 4. PTVs of the prostheses showed higher scores and standard deviations than those of abutments regardless types of connection (P<0.05).

  • PDF

자동변속기 클러치 디스크 마찰특성의 실험적 분석 (Experimental Analysis of an Automatic Transmission Clutch Disk Friction Characteristics)

  • 정규홍;박동훈;나두현
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권3호
    • /
    • pp.14-20
    • /
    • 2018
  • Wet clutches in an automatic transmission enable the transmission of the engine power by the frictional torque experienced and noted between disk and plates. Since the clutch frictional torque considerably affects the shift quality of an automatic transmission as well as the durability of the machinery, its friction characteristics must be carefully examined to meet the design requirements. The SAE No. 2 friction test machine is a well-known standard to evaluate mainly the friction characteristics of plate clutches along with the required automatic transmission fluids. This paper reviews the experimental analysis of the wet clutch friction characteristics by using the exclusively developed clutch test machine which is capable of controlling the clutch test procedure, in accordance with the applicable test standard and processing of the experimental data automatically. As the clutch test machine is designed for the accommodation of dual clutches which is applied to the real transmission, it can evaluate not only the clutch friction characteristics, but also an actuation performance of a measured clutch piston. In respect to friction characteristics involving dynamic friction coefficients, the energy absorbed in a clutch disk and the recorded temperatures of clutch plates during braking actions and procedures are also investigated. Additionally, the change of friction coefficients by the use of the repeated clutch application is also observed with the endurance test functions of an accurately calibrated and dedicated clutch test machine.

Reproducibility of the Isokinetic Joint Torque as a Rotator Cuff Weakness Test Protocol in Patients With Rotator Cuff Tendinitis

  • Kim, Soo-yong;Oh, Jae-seop
    • 한국전문물리치료학회지
    • /
    • 제24권3호
    • /
    • pp.21-29
    • /
    • 2017
  • Background: The measurement of the strength of the shoulder muscles is an important element of the overall assessment of patients with various shoulder disorders. However, the clinical utilization of this measurement is dependent on its reproducibility. Objects: To explore the reproducibility of the measurements derived from testing of the isokinetic strength of shoulder muscles in patients with tendinitis of the rotator cuff. Methods: A total of 20 patients with tendinitis of the rotator cuff participated in this study and were assessed twice in 1 week. Isokinetic testing was performed concentrically for shoulder flexors, abductors, and external rotators and eccentrically for the shoulder extensors, adductors, and internal rotators. The relative and absolute reproducibility of the peak torque (PT) and ratios were assessed using intra-class correlation coefficients (ICC), standard error of measurement (SEM), and minimal clinically important difference (MCID), respectively. Results: Overall, high to excellent ICC, clinically acceptable SEM and MCID values were obtained for the PT (ICC: .83-.95, SEM: 1.2%-9%, MCID: 3.4%-25%) and ratios (ICC: .85-.93, SEM: 5.1%-10%, MCID: 14.2%-27.6%). Conclusion: These findings suggest that isokinetic tests may be effectively utilized for the determination of shoulder strength profiles and appropriate position are recommended to perform test without pain in patients with tendinitis of the rotator cuff.

발레 Jetė 동작의 도움닫기와 점프구간에서 상해 발생 요인에 대한 생체역학적 분석 (Biomechanical Analysis of Injury Factors in the Run UP and Jump Phases of the Jetѐ)

  • 이진
    • 한국운동역학회지
    • /
    • 제22권3호
    • /
    • pp.295-304
    • /
    • 2012
  • This study, through biomechanical analysis, conducts a risk assessment of injury occurrence in ballet dancers while they perform running and jumping movements. The participants were nine female collegiate students majoring in ballet(age: $20.89{\pm}1.17years$; height: $160.89{\pm}7.01cm$; mass: $48.89{\pm}3.26$). Descriptive data were expressed as $mean{\pm}standard$ deviation(SD) for all variables. An independent t-test was conducted to determine how the following variables differed: duration time, position of the center of gravity, angle of the hip, torque of the hip, and muscle activity. All comparisons were made at the p<0.05 significance level. The results show that the jump time was two times longer than the run time in the duration time. The jump length was also longer than the run. The angle of the hip and the torque at the hip were higher in the right. The vastus medialis muscle was most frequently used. These findings demonstrate that participants' jumps may require more biomechanical variables for performance of better and more correct $jet{\acute{e}}$.

HIGH-TPI HDD 구현을 위한 PES ESTIMATION에 관한 연구 (A Study on the PES Estimation for Developing High-TPI HDD)

  • 고정석;강성우;한윤식;김영훈;황태연
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.122-127
    • /
    • 2002
  • A frequency-domain PES estimation and its prediction method are proposed for the tightly-coupled servo/mechanical design of high-TPI HDD system above 100 kTPI. The major two disturbance energies which are related with mechanical vibrations inside of HDD are used to predict the drive-level PES, while considering closed-loop servo dynamics. One is the torque disturbance which mainly comes from aerodynamic excitation of HSA system and the other is the displacement disturbance from disk-spindle dynamics. In order to obtain the accurate error transfer function of closed-loop servo control, the plant model is measured by accurate experiment. The measured PES is compared with predicted one in terms of frequency-domain PES spectrum and its standard variation value. It is proved that the proposed frequency-domain PES estimation/prediction method is capable of predicting drive-level PES of high-TPI hard disk drive.

  • PDF

A High Performance Permanent Magnet Synchronous Motor Servo System Using Predictive Functional Control and Kalman Filter

  • Wang, Shuang;Zhu, Wenju;Shi, Jian;Ji, Hua;Huang, Surong
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1547-1558
    • /
    • 2015
  • A predictive functional control (PFC) scheme for permanent magnet synchronous motor (PMSM) servo systems is proposed in this paper. The PFC-based method is first introduced in the control design of speed loop. Since the accuracy of the PFC model is influenced by external disturbances and speed detection quantization errors of the low distinguishability optical encoder in servo systems, it is noted that the standard PFC method does not achieve satisfactory results in the presence of strong disturbances. This paper adopted the Kalman filter to observe the load torque, the rotor position and the rotor angular velocity under the condition of a limited precision encoder. The observations are then fed back into PFC model to rebuild it when considering the influence of perturbation. Therefore, an improved PFC method, called the PFC+Kalman filter method, is presented, and a high performance PMSM servo system was achieved. The validity of the proposed controller was tested via experiments. Excellent results were obtained with respect to the speed trajectory tracking, stability, and disturbance rejection.