• 제목/요약/키워드: Torque measurement device

검색결과 34건 처리시간 0.026초

로드셀과 토크암을 이용한 대용량 토크 측정장치 개발에 관한 연구 (Development of device measuring very high torque via torque arm with attached load cells)

  • 이용범;한승호
    • 유공압시스템학회논문집
    • /
    • 제7권1호
    • /
    • pp.6-10
    • /
    • 2010
  • A measurement of very high torque for track drive unit in construction equipment is usually in difficulties due to the requirement of a torque meter with high capacity, and the limitation of geometry for an experimental set-up. To improve the troublesome problem, a new device was proposed, where a torque transmitted through the torque arm can be measured by load cells attached at each torque arm. The experimental set-up of the new device was carried out in order to measure the torque values for a mechanical feedback type planetary gear box, in which the power flow circulates itself in a closed-loop. The new device enables to measure torque values of 60,000Nm. Additionally, the measured values were estimated statistically in the aspect of their repeatability and reproducibility, so that an acceptable behaviour as a measuring device can be confirmed.

  • PDF

구면 정압베어링의 마찰토크 측정장치 개발 (Development of Friction Torque Measurement Device for Spherical Hydrostatic Bearing)

  • 함영복;최영호;박경민;윤소남;김광영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.181-186
    • /
    • 2002
  • Lately, as going on increasing in the demand of high power density(power/weight), it is necessary for hydraulic axial piston pump/motor to operate more high pressure and speed. But in these condition, there are some trouble like as friction loss. To reduce this friction loss, hydrostatic bearing is used far axial piston pump/motor frequently. In general, it is difficult to measure accurate friction torque of spherical hydrostatic bearing in the use of the existing devices. So, we have developed the measurement device using the reaction torque sensor to obtain the pure friction torque, fitted in the casing. In this report, we intend to make an introduction about this measurement device for friction torque of the spherical wear part and clarify the effect of friction characteristics on supply pressure and rotational speed with three types of pocket size by using this measurement device.

  • PDF

임플란트에 사용되는 수동 토크발생장치의 정확성 비교 (The Comparison of the Accuracy upon the Manual Torque Generating Devices for the Implant)

  • 김동환;김한수;오상호;정재헌
    • 구강회복응용과학지
    • /
    • 제23권3호
    • /
    • pp.227-237
    • /
    • 2007
  • Various methods and torque generating devices are developed and employed to apply proper torque clinically. In this study, clinically used torque control devices are measured whether uniformed and precise torque are generated. Digital torque gauge are employed for measurement and torque driver, torque limiting device, torque indicating device are used for torque generating devices. ${\chi}^2$ distribution was formed and One-way ANOVA(Turkey test) was performed to measure torque values generated by each torque generating device. In the results, all companies have been shown slight errors and deviations. This indicates a difficulty of applying precise torque. Therefore, it would be recommended torque generating device should be checked whether uniformed and precise torque can be generated and an error should be corrected.

회전방지장치와 지대주의 내육각구조가 임플란트로 전달되는 조임 회전력에 미치는 영향 (EFFECT OF A COUNTER-TORQUE DEVICE AND THE INTERNAL HEXAGON OF ABUTMENT ON THE TIGHTENING TORQUE TRANSMITTED TO THE IMPLANT)

  • 이상민;전영찬;정창모
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.223-231
    • /
    • 2003
  • Statement of problem : Little is known about the effect of a counter-torque device and the internal hexagon of abutment on the tightening torque transmitted to the implant. Purpose : The purpose of this study was to examine the effect of a counter-torque device and the internal hexagon of abutment on the tightening torque transmitted to the implant. Material and Methods : In this study, three types of abutment were used, (1) two-piece conical abutment with hexagon, (2) two-piece conical abutment without hexagon, and (3) one-piece conical abutment without hexagon. The experimental groups were divided into five groups according to the type of abutment and the usage of a counter-torque device. Group I : two-piece conical abutment with internal hexagon was tightened without the use of a counter-torque device. Group II : two-piece conical abutment without internal hexagon was tightened without the use of a counter-torque device. Group III : one-piece conical abutment without internal hexagon was tightened without the use of a counter-torque device. Group IV : two-piece conical abutment with internal hexagon was tightened with the use of a counter-torque device Group V : two-piece conical abutment without internal hexagon was tightened with the use of a counter-torque device. Abutments were tightened 20Ncm torque with the use of manual torque wrench and then torque values were measured by torque-gauge. After the measurement of torque values, all groups were loosened with the use of manual torque wrench and then detorque values were measured by torque-gauge. Results : The results were as follows. 1. There were no differences in torque values among three types of abutment. 2. Regardless of the existence of the internal hexagon of abutment, a counter-torque device decreased the tightening torque transmitted to the implant about 92% 3. In group III showed the highest detorque value, however there were no differences among group I, II, IV and V. Conclusion : Within the limitations of this study, it was concluded that the internal hexagon of abutment has no effect on the tightening torque transmitted to the implant and the detorque value of abutment screw. The use of a counter-torque device is essential to prevent microfracture on the implant-bone interface but has no effect on preload.

위치/힘 동시제어를 위한 F/T측정 기능을 갖는 6축 순응기구 설계 (Design of a 6-axis Compliance Device with F/T Sensing for Position/Force Control)

  • 김한성
    • 한국산업융합학회 논문집
    • /
    • 제21권2호
    • /
    • pp.63-70
    • /
    • 2018
  • In this paper, the design of a novel 6-axis compliance device with force/torque sensing capability and the experiment results on force measurement are presented. Unlike the traditional control methods using a force/torque sensor with very limited compliance, the force control method employs a compliant device to provide sufficient compliance between an industrial robot and a rigid environment for more stable force control. The proposed compliance device is designed to have a diagonal stiffness matrix at the tip and uses strain gauge measurement which is robust to dust and oil. The measurement circuit is designed with low-cost IC chips however the force resolution is 0.04N.

무선계측을 이용한 휠로더 구동토크의 주요인 분석 (Analysis of the Main Factor of Wheel Loader Torque via Wireless Measurements)

  • 강병익;동홍일;김병기;최용훈
    • 한국기계가공학회지
    • /
    • 제19권4호
    • /
    • pp.24-29
    • /
    • 2020
  • Measuring the torque of the wheel loader of a driving device is a preemptive task to ensure its performance. In this study, wireless torque measurements were successfully conducted. Moreover, based on the experimental results and the adopted design method, the key factor of torque generation, which is the main load in driving devices, was analyzed. Other data not analyzed in this paper will be the basis for the logical design of wheel loader-based driving devices.

계절에 따른 실험실 환경변화를 이용한 토크측정기의 온도 및 습도 감도계수 결정 (The Determination of Temperature and Humidity Sensitivity Coefficients of Torque Transducers using Seasonal Climatic Changes of Ambient Conditions in the Laboratory)

  • 무루게타;김민석;박연규;이호영
    • 한국정밀공학회지
    • /
    • 제32권2호
    • /
    • pp.185-190
    • /
    • 2015
  • This paper presents a new method to determine sensitivity coefficients of temperature and humidity of torque transducers by using a natural and seasonal variation of ambient conditions at the laboratory. We had measured the sensitivities of the torque transducers over almost one year using the KRISS 2 kN m torque standard machine. The sensitivity data acquired at various ambient conditions were processed using our measurement model to extract the sensitivity coefficients of temperature and humidity simultaneously with high precision. A comparison with a previous method using an environmental control chamber was carried out to test the feasibility of using our new method. Two results agreed within the uncertainty. We revealed that the torque measuring errors could be 8 times higher than the measurement and calibration capability of KRISS torque standard machine if the sensitivity changes due to the temperature and humidity are not properly corrected during a calibration.

자기장을 이용한 비접촉 토크센서설계

  • 송중록;조종두;반강;김재민;김웅지
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1087-1090
    • /
    • 2007
  • A wireless magnetic torque sensor is utilized to measure the torque generated in the rotating shaft in magnetic field without connecting to the shaft by any wire. In this study, a new wireless magnetic torque sensor was introduced. The structure of the sensor was explained detailed as well as its operation principle. Resulting from the torque measurement experiment results, the sensor was proven to measure the generated torque effectively. Compared with traditional contact torque sensor, the wireless one has low cost and good environment adaptation ability. Moreover, the intractable wrapping wires around the shaft are removed in this design. Hence the wireless torque sensor may be expected as a possible sensing device for many applications, such as the electric assisting rotation system in automobiles, the torque sensing system in motors, the arm rotation system in robotics and so on.

  • PDF

힘측정기반 팔꿈치 재활로봇 설계 및 힘제어 (Design of an Elbow Rehabilitation Robot based on Force Measurement and its Force Control)

  • 김한솔;김갑순
    • 제어로봇시스템학회논문지
    • /
    • 제21권5호
    • /
    • pp.413-420
    • /
    • 2015
  • This paper describes the design of an elbow rehabilitation robot based on force measurement that enables a severe stroke patient confined to their bed to receive elbow rehabilitation exercises. The developed elbow rehabilitation robot was providewitha two-axis force/torque sensor which can detect force Fz and torque Tz, thereby allowing it to measure therotational force (Tz) exerted on the elbow and the signal force Fz which can be used as a safety device. The robot was designed and manufactured for severe stroke patients confined to bed, and the robot program was manufactured to perform flexibility elbow rehabilitation exercises. Asa result of the characteristics test of the developed rehabilitation robot, the device was safely operated while the elbow rehabilitation exercises were performed. Therefore, it is thought that the developed rehabilitation robot can be used for severe stroke patients.

사물인터넷 센서를 이용한 동적 부품의 스트레인 측정 방법 (Strain measurement method for moving parts using IoT sensors)

  • 김바다;안영철;박정현;유영준;이철희;이대엽
    • 드라이브 ㆍ 컨트롤
    • /
    • 제20권1호
    • /
    • pp.41-47
    • /
    • 2023
  • The aim of this study was to develop a method for installing strain gauges on moving, lubricating oil-filled, and sealed parts, such as drive shafts of equipment, including construction machinery. A measuring device was constructed using an embedded CPU and an IoT sensor to measure the strain of the strain gauge, which allowed for the measurement of axial torque and axial force, and subsequent analysis. To verify the performance of the developed device, the axial torque and axial force of the forklift were measured during operation using a strain gauge attached to the inside of the drive shaft. This study confirmed the possibility of measuring and analyzing the strain of a moving part, such as the inside of a drive shaft, which is sealed and filled with hydraulic oil.