• Title/Summary/Keyword: Torque Transferred

Search Result 32, Processing Time 0.029 seconds

A Haptic Master-Slave Robot System : Experimental Performance Evaluation for Medical Application (의료용 햅틱 마스터-슬레이브 로봇 시스템 : 실험적 성능 평가)

  • Oh, Jong-Seok;Shin, Won-Ki;Nguyen, Phuong-Bac;Uhm, Chang-Ho;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.421-427
    • /
    • 2012
  • In this work, 4 DOF ER haptic master is proposed and integrated with a slave robot for minimally invasive surgery (MIS). Using a controllable ER fluid, the haptic master can generate a repulsive force/torque with the 4-DOF motion. For realization of master-slave robot system, the motion command of the haptic master is realized by slave surgery robot. In order to follow the 4 DOF motion of the haptic master, novel mechanism of slave surgery robot with gimbal joint is devised. Accordingly, the haptic master-slave robot system is established by incorporating the slave robot with the haptic master device in which the desired repulsive force/torque and position are transferred to each other via wireless communications. In order to obtain the desired force/torque and position trajectories, tracking controllers for haptic master and slave robot are designed and implemented, respectively. It has been demonstrated that the desired effective torque tracking control performance is well achieved using the proposed haptic master-slave robot system.

  • PDF

A Ballooning Phenomenon of Torque Converter Torus Size for Automatic Transmissions (자동변속기용 토크컨버터 토러스 사이즈에 따른 팽창 현상)

  • Jang, Jaeduk;Lee, Woongcheol;Sung, Dukhwan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.6
    • /
    • pp.702-708
    • /
    • 2016
  • The torque converter is deformed according to the rotating speed and control pressure when engine power is transferred to the transmission. This deformation, which is called ballooning phenomenon, occurs mainly at the outer side by the centrifugal force of the automatic transmission fluid (ATF) and the control pressure from the valve body. Although the torque converter is slightly deformed when rotating, the ballooning phenomenon affects fluid performance, efficiency and durability. Thus, expansion characteristics analysis is important in determining torus size, control pressure and structure. In this paper, an analysis equation and FEM model was developed to investigate the expansion characteristics. Using this model, structural analysis was performed to investigate the relationships between deformation and the torus diameter. The results were confirmed by comparing with the test results.

Manufacturing Process and Basic Property Tests of Composite Helicopter Rotor Hub System (복합재 헬리콥터 로터 허브 시스템의 제작 및 기본 물리량 시험)

  • Kee, Youngjung;Kim, Taejoo;Yun, Chulyong;Kim, Doegkwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.6
    • /
    • pp.691-698
    • /
    • 2014
  • This paper describes the manufacturing processes for a flexbeam and torque tube made of composite materials, along with the procedures for testing their basic properties. A flexbeam and torque tube can be considered to be key structural components of a bearingless rotor hub system. A hinge offset effect can be realized by a large elastic deformation and twist of the flexbeam, and the blade pitch control forces are transferred by the rotation of the torque tube. The basic property tests included bending and twist tests to determine the flap stiffness, lag stiffness, and torsion stiffness of the flexbeam, torque tube, and blade, and these tests were performed prior to starting the whirl tower test. In addition, the estimated results were compared with experimental data, and the calculations were found to be a good match for the analysis results and had a similar tendency. Through these results, we could confirm that a flexbeam and torque tube made of composite materials satisfied the structural stiffness requirements.

A Operating by the Direct Thrust Control of SLIM in Conveyor System (반송용 SLIM의 추력제에에 의한 운전특성)

  • 우정인;노태균;신동률;노인배
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.59-66
    • /
    • 1998
  • In this paper, the thrust control of PWM Inverter-Fed SLIM(Single-sided Linear Induction Motor) is achieved with Space Vector control and PI control. The trembling of air gap length which is occurred between the primary winding core and the secondary structure of the SLIM must be minimized in order to get quick response characteristics. First, the equivalent circuits and voltage equations of SLIM are shown on th suitable d-q axis which analyze characteristics of the thrust and the normal force. Also, modeling and analysis of the equivalent circuits transferred d-q axis are able to make robust transient torque from the current regulation in the equivalent circuit. These results exemplified the direct drive of SLIM with the reference speed and torque were verified by experiments.

  • PDF

Development of Machine Tool Monitoring System Using OPC (OPC를 이용한 공작 기계 감시 시스템의 개발)

  • Tae H.C.;Jeong Y.H.;Cho D.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.564-567
    • /
    • 2005
  • For the application of monitoring system of the machine tool to industry, the requirements such as high reliability and low cost need to be satisfied. In this study, a reliable but inexpensive monitoring method for machine tool is introduced. To improve the monitoring reliability, several kinds of information related to machining and operation are selected; real-time video clip from USB camera, operation data and signal from CNC and feed motor torque. Especially, to improve the quality of real-time video clip, a camera housing is developed, it can significantly reduce the vibration effect and prevent from coolant and chip. The collected information are transferred to the monitoring terminals in remote sites using OPC and TCP/IP protocol over Ethernet, which give us convenience of development and interoperability.

  • PDF

Three Phase Drive Transfer Algorithm for Fault Tolerance Control of Six-Phase PMSM (6상 영구자석 동기전동기의 고장대응운전을 위한 3상 구동시스템 전환 알고리즘)

  • Kim, Seong-Hoon;Jang, Won-Jin;Cho, Kwan-Yuhl;Kim, Hag-Wone
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.4
    • /
    • pp.256-262
    • /
    • 2021
  • Six-phase motors can be used in industrial applications, such as an electric vehicle, due to their high reliability and low current magnitude per phase. An asymmetrical PMSM with two sets of three-phase windings is a commonly used structure for six-phase motors, with each winding set demonstrating a phase difference of 30°. Although the asymmetrical PMSM presents low torque ripples, its dynamic torque response deteriorates due to coupled components in the two three-phase windings. The decoupled VSD control is applied to eliminate the coupling effect. Load ratio control of two inverters for the six-phase PMSM is proposed in this study. DQ currents are controlled on the basis of two synchronous reference frames, and the six-phase drive system can be changed to a three-phase drive system when one inverter presents fault conditions. The operation and effectiveness of the proposed algorithm is verified through simulation and experiments. The six-phase drive system is transferred to a three-phase drive system by changing the current reference of the second DQ reference frame. Moreover, control of both torque and speed exhibits satisfactory performance before and after the mode change.

In Vitro Study on the Initial Stability of Two Tapered Dental Implant Systems in Poor Bone Quality (연질 골에서 두 종류의 테이퍼 형태 임플란트의 초기 안정성에 관한 실험실적 연구)

  • Kim, Duck-Rae;Kim, Myung-Joo;Kwon, Ho-Beom;Lee, Seok-Hyung;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.391-401
    • /
    • 2009
  • The successful outcome of dental implants is mainly the result of intial implant stability following placement. The aim of this study was to investigate the effect of a self-tapping blades and implant design on initial stability of two tapered implant systems in poor bone quality. The two different implant systems included one with self-tapping blades and one without self-tapping blades. D4 bone model using Solid Rigid Polyurethane Form was used to simulate poor bone densities. The insertion torque during implant placement was recorded. Resonance frequency Analysis (RFA), measured as the implant stability quotient (ISQ), was assessed immediately after insertion. Finally, the implant-bone specimen was transferred to an Universal Testing Machine to measure the axial pull-out force. Insertion torque values and maximum pull-out torque value of the non self-tapping implants were significantly higher than those in the self-tapping group (P = 0.008). No statistically differences were noted between the two implant designs in RFA. Within the each implant system, no correlation among insertion torque, maximum pull-out torque and RFA value could be determined. Higher insertion torque of the non-self-tapping implants appeared to confirm higher clinical initial stability. In conclusion, implants without self-tapping blades have higher initial stability than implants with self-tapping blades in poor bone quality.

Colonoscopy Training Simulator

  • Yi, S.Y.;Woo, H.S.;Kwon, J.Y.;Joo, J.K.;Lee, D.Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.57-61
    • /
    • 2005
  • This paper presents a new colonoscopy training simulator that includes a specialized haptic device and graphics algorithms to transfer haptic sensation through a long and flexible tube, and manage large number of polygons. The developed haptic device makes the colonoscope tube move along the two guiding rods in the translational direction. The torque of the roll motion is transferred by a timing belt and pulleys. A special guide is developed, which allows the force and torque from the motors to be transmitted to the user without loss. The haptic device is evaluated by physicians. One of the important skills of the colonoscopy, jiggling is incorporated for the first time by the developed sensor mechanism using photo-sensors. A colonoscope handle that shares the look, feel, and functions with the actual colonoscope, is developed with the necessary electronics inside. The number of polygons is reduced by an edge-collapse algorithm for real-time simulation. The algorithms to import CT data, to segment the colon image, to extract centerline of the colon, and to construct the colon surface, are integrated into a Colon Modeling Kit system that performs all these processes in real-time.

  • PDF

A Robust PID Control Algorithm for a Servo Manipulator with Friction

  • Jin, Jae-Hyun;Park, Byung-Suk;Lee, Hyo-Jik;Yoon, Ji-Sup
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2275-2278
    • /
    • 2005
  • In this paper, a control algorithm for a servo manipulator is focused on. A servo manipulator system has been developed for remotely handling radioactive materials in a hot cell. It is driven by servo motors. The torque from a servo motor is transferred through a reducer to the corresponding axis. The PID control algorithm is a simple and effective algorithm for such application. However, since friction degrades the algorithm's performance, friction has to be considered and compensated. The major aberrations are the positional tracking errors and the limit cycle. The authors have considered a switching term to a conventional PID algorithm to reduce the friction's effect. It has been tested by a hardware test.

  • PDF

Construction of Torque Measurement System for High Speed Railway (고속열차의 동력전달축 부하측정 시스템 구축 방안)

  • Kim, Sang-Soo;Kim, Young-Kuk;Kim, Ki-Hwan;Han, Young-Jae
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.780-785
    • /
    • 2007
  • Korean Train Express (KTX) has opened to commercial traffic since 2004 at maximum speed 300km/h, and Korea High-speed Railway (HSR-350x) was developed by Korean government, several institutes, and related companies. HSR-350x is now being investigated its performance and tested at the high speed line. In 2004 December, HSR-350x was run over 350km/h and proved its running performance. These high speed railways have 12 motors to transfer the traction effort or the braking force. In this paper, authors propose the construction the measurement system for monitoring the force transferred to the train from the motor. The system is installed to the tripod shaft which is located between the reduction gears and it measures the mechanical load directly.

  • PDF