• Title/Summary/Keyword: Tooth shape

Search Result 343, Processing Time 0.028 seconds

The Development of Decelerating Motor of Electronic Power Steering (EPS 감속 모터 개발)

  • Lee, Jeong-Ick
    • Journal of the Korea Convergence Society
    • /
    • v.2 no.2
    • /
    • pp.27-34
    • /
    • 2011
  • This study is making a product for the development of one process worm wheel of making a shape for gear for worm wheel without hobbing manufacturing process. Because of removing a hobbing process, plastic worm wheel for increased productivity and equivalent quality is produced in the result. As the result, this product is selling to Hyundai Mobis, Mando, TRW, KOYO/NSK/Showa(Japan), Delphai(America). The core technology and different strategy are as follows. The technology protection for molding of worm whee is currently patent process "Molding process of helical gear(No. 10-2008-0105908). Further patent procedure for "molding system for positioning decision of inserting boss is currently prepared. As gear molding procedure in hobbing machine without gear machining procedure, most of all, core development technology which is making a gear tooth is main topic. So that, in case of currently developed worm wheel, because core and mold base are not developed in the first procedure, gear is machining in hobbing M/C as the second procedure. In the later, patent for mold base structure will be prepared in this study results.

Pitting Life for RRP System (RRP 시스템의 피팅수명)

  • Kim, Chang-Hyun;Nam, Hyung-Chul;Kwon, Soon-Man
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.4
    • /
    • pp.387-393
    • /
    • 2012
  • A roller rack pinion (RRP) system, which consists of a rack-bar and a cam pinion, transforms a rotation motion into a linear one. The rack-bar has a series of roller trains, and meshes with the cam pinion. This paper first proposes the exact tooth profile of the cam pinion and the non-undercut condition to satisfy the required performance by introducing the profile shift coefficient. The paper then investigates the load stress factors under various shape design parameters to predict the gear surface fatigue limit, which was strongly related to the gear noise and vibration at the contact patch. The results show that the pitting life can be extended significantly with an increase in the profile shift coefficient.

INCONTINENTIA PIGMENTI (BLOCH-SULZBERGER SYNDROME) WITH DENTAL PROBLEMS : CASE REPORT (색소실조증 환아의 증례보고)

  • Lee, Sang-Yup;Kim, Dae-Eop;Lee, Kwang-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.4
    • /
    • pp.682-686
    • /
    • 2005
  • Incontinentia pigmenti(IP), so called Block-Sulzberger syndrome is a rare genodermatosis that occurs almost in female infant; usually lethal in males, X-linked dominantly inherited disorder. IP is characterized by abnormalities of mesodermal and ectodermal tissues including eye, tooth, skin, nail, breast and hair as well as neurological deficiencies. Dental problems are congenital missing of teeth, delayed eruption, abnormal crown shape and so on. Here is a case of 6 year-old female with IP. She had congenital missing of primary and permanent teeth, delayed eruption, maxillary deficiency and extra cusps, resulting in unstable occlusion. Systemically, she had a history of operating eyes due to problem of retina and hyperpigmented macules on her trunk and extremities as typical character of IP.

  • PDF

A Survey on Lactation and Weaning Practice of Infants and Their Mothers' Attitude on Infant Nutrition in Kangwon Province (강원 일부 지역 영유아의 수유 및 이유실태와 영아 영양에 대한 어머니들의 태도)

  • Lee Jeong-Sill;Choi Kyung-Soon
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.15 no.4
    • /
    • pp.373-385
    • /
    • 2005
  • This study was carried out to investigate the lactation and weaning practice of infants and their mothers' attitude on infant nutrition. We interviewed 152 mothers in three pediatric clinics located in Sokcho city. From this survey, $76.3\%$ of infants was fed colostrum milk during first one week of life. During the first 4 months, $31.6\%$ of infants was fed breast-milk, while $42.8\%$ of them was fed bottled-milk. More housewives fed their babies with breast milk than the working mothers. Infants ate first weaning food at 5.73$\pm$1.86 months of life. Highly educated mothers showed positive response to the questionnaire : Breast-feeding is good for baby but it requires mother's sacrifice, and Breast-feeding may ruin the good shape of mothers. Highly income mothers responded negatively to the statement : Breast-feeding is not a must for infants since bottled-milk is a good substitution for breast-milk. Comparing with the mothers whose income was about 1 -2 million won per month, with ones who got paid less than 1 million won per month the former responded positively to : Breast-feeding is good for baby but it requires mother's sacrifice. Mothers recognized the importance of weaning in the following order : Supply of nutrition, Enforcement of digestion and absorption capability, Variety of taste, Disease prevention, Development of self-reliance, and Development of baby tooth. To improve the infants' nutritional status, education program on infant nutrition should be organized and run for the pregnant and lactating women in obstetrician and pediatric clinics and through the mass media as well.

  • PDF

The EFFECTS OF DENTAL LASER ON PULP FIBROBLAST IN VITRO (치과용 레이저 조사가 배양 치수 섬유모세포에 미치는 영향에 관한 연구)

  • Jeong, Hye-Jeon;Min, Byung-Soon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.519-535
    • /
    • 1997
  • The responses of human pulp fibroblastic cells to Ga-As Semi-Conductor-Dens-Bio Laser (Frequency: 5 Hz~10,000 Hz Model: SD-101A RCA, U.SA)) were examined in vitro using pulp fibroblastic cells obtained from the pulp tissue of human tooth. The mitogenic effect of soft laser was assessed by measuring the MTT assay. The morphologic effect for soft laser showed under the scanning and transmission electron microscopy. The results as follows; 1. The mitogenic response of the soft laser was not observed until 4th time of radiation, while the mitogenic response at 4th time increased mitogenic effect by as much as 1.7 fold compared to the control value. 2. The mitogenic response of the soft laser on pulp fibroblast differ from the mitogenic response on other fibroblasts. 3. In scanning electron microscopic study, The microvilli of cell surface increased gradually with width and length after laser radiation, it demonstrate that development of microvilli have close connection with differentiation of cells. 4. Under the transmission electron microscope, The laser-treated cells maintained their elongated shape and a high degree of cellular polarization. The large cell body containing a well developed Golgi complex, a large number of profiles of rough endoplasmic reticulum, and great numbers of mitochondria. 5. The laser-treated cells maintained the long straight bundles of closely apposed microfilaments or individual filaments forming a cross-linked network. These findings suggest that the laser may have important roles in promotion of pulp healing and consequently may be useful for clinical application in pulp regenerative procedures.

  • PDF

Occlusal and Periodontal Status of Teeth with Non-carious Cervical lesions (비우식성 치경부병소를 가진 구치부 치아의 교합 및 치주상태에 관한 연구)

  • Son, Min-Ook;Seo, Sung-Chan;Jeong, Dong-Keun;Lee, Eun-Suk;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.3
    • /
    • pp.647-657
    • /
    • 2004
  • A non-carious cervical lesion(NCCL) is the loss of tooth structure at the cementoenamel junction level that is unrelated to dental caries. This study was to evaluate the occlusal and periodontal status of teeth with non-carious cervical lesions. We evaluated 105 teeth with non-carious cervical lesions in 35 subjects aged 38-75 years and characterized them based on the shape and dimension, plaque retention, bleeding on probing(BOP), probing pocket depth(PPD), occlusal status, brushing type, hypersensitivity and wear facet. The results of this study were as follows 1. No significant association was observed between cervical lesions and occlusal contact in lateral excursions. 2. No significant difference occurred in plaque retention, PPD, BOP between teeth with and without cervical lesions. 3. Test teeth had a significantly higher percentage of hypersensitivity and occlusal wear facet than teeth without cervical lesions. 4. Wedge shaped lesions had a significantly higher percentage of plaque than saucer shaped lesions. 5. Teeth with plaque were found to have significantly deeper PPD than teeth without plaque retention in cervical regions. 6. Teeth with occlusal contacts were found to have significantly deeper PPD than teeth without occlusal contacts. 7. No significant association was observed between cervical lesions and PPD independent of plaque retention and occlusal contacts Although more knowledge is necessary, our results suggest that occlusal contact and bacterial plaque may influence on periodontal tissue, but NCCL is not directly associated with periodontal health

Evaluation of biogeneric design techniques with CEREC CAD/CAM system

  • Arslan, Yeliz;Nemli, Secil Karakoca;Gungor, Merve Bankoglu;Tamam, Evsen;Yilmaz, Handan
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.6
    • /
    • pp.431-436
    • /
    • 2015
  • PURPOSE. The aim of this study was to evaluate occlusal contacts generated by 3 different biogeneric design modes (individual (BI), copy (BC), reference (BR)) of CEREC software and to assess the designs subjectively. MATERIALS AND METHODS. Ten pairs of maxillary and mandibular casts were obtained from full dentate individuals. Gypsum cast contacts were quantified with articulating paper and digital impressions were taken. Then, all ceramic crown preparation was performed on the left first molar teeth and digital impressions of prepared teeth were made. BI, BC, and BR crowns were designed. Occlusal images of designs including occlusal contacts were superimposed on the gypsum cast images and corresponding contacts were determined. Three designs were evaluated by the students. RESULTS. The results of the study revealed that there was significant difference among the number of contacts of gypsum cast and digital models (P<.05). The comparison of the percentage of virtual contacts of three crown designs which were identical to the contacts of original gypsum cast revealed that BI and BR designs showed significantly higher percentages of identical contacts compared with BC design (P<.05). Subjective assessment revealed that students generally found BI designs and BR designs natural regarding naturalness of fissure morphology and cusp shape and cusp tip position. For general occlusal morphology, student groups generally found BI design "too strong" or "perfect", BC design "too weak", and BR design "perfect". CONCLUSION. On a prepared tooth, three different biogeneric design modes of a CAD/CAM software reveals different crown designs regarding occlusal contacts and morphology.

Esthetic restoration of malpositioned anterior teeth by tooth shape and gingival contour modification : a clinical report (위치이상 치아의 치은 성형을 동반한 심미적 보철수복)

  • Kim, Ja-Yeong;Kim, Kyoung-A;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.143-149
    • /
    • 2015
  • In esthetic treatments, it is important to consider the arrangement of teeth and the relation between the teeth and soft tissues. A precise diagnosis and establishing an appropriate treatment plan is essential in an esthetic treatment of anterior maxillary teeth. For a fixed prosthesis to meet esthetic expectations, It is crucial to achieve symmetry and adequate proportions of the gingival contour around the crowns. To achieve an esthetic improvement and creating a favorable environment for gingival healing of a physiologic gingival contour, gingivectomy, crown lengthening and forced eruption can be applied to the appropriate site. All ceramics or porcelain laminate veneer can be selected for esthetic improvement of teeth contour and shade. In this case report, malposition of the remaining teeth made it hard to get an esthetic appearance. Gingivectomy, crown lengthening and provisional restoration insertion were performed before the final prosthesis fabrication to reform the gingival form. This case presents satisfying result esthetically and functionally.

Accuracy of full arch digital model obtained from rendering-based intraoral scanner(IOS) : An example of CS-3600 system (동영상 촬영방식의 구강스캐너로 채득된 전악치열 디지털모형의 정확도 분석 : CS-3600 시스템을 중심으로)

  • Kim, Jae-Hong
    • Journal of Technologic Dentistry
    • /
    • v.42 no.1
    • /
    • pp.17-25
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate and compare the accuracy of definitive casts that are fabricated from digital intraoral impression and conventional impression technique. Methods: A master model(ANNA-4, Frasaco GmbH, Tettnang, Germany) with the prepared upper full arch tooth was used. Conventional impression and then stone model(n=10) were produced from this master model, and on the other hands, digital impressions were made with the CS-3600 intraoral scanner(n=10). Six linear measurements were recorded between landmarks, directly on each of the stone models on two occasions by a single examiner. Measurements were made with a digital caliper to the nearest 0.01mm from manual models and with the software(Delcam PowerSHAPE) from the virtual models. The t-student test for paired samples and intraclass correlation coefficient(ICC) were used for statistical analysis. Results: The measurement of two methods showed good reliability. The ICC of the two models were 0.88~0.91(stone model) and 0.94~0.99(digital model). The mean differences to master model for stone model and digital model were 0.10~0.14mm, and 0.14~0.20mm, respectively. Conclusion: The definitive casts obtained with digital intraoral technique model had significantly larger dimensions as compared to those of the stone model. However, the differences to the master model detected appear to provide enough accuracy and reliability for clinical application.

INFLUENCE OF VARIOUS PROPERTIES OF POST AND CORE ON THE STRESS DISTRIBUTION IN ENDODONTICALLY TREATED TOOTH (다양한 포스트와 코어의 물성이 근관치료된 치근의 응력분산에 미치는 영향)

  • Cho Jin-Hyun;Lee Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.10-19
    • /
    • 2006
  • Statement of problem : The various kinds of properties of post and core may affect the stress distribution to the root of endodontically treated teeth Purpose: To evaluate the influence of various kinds of properties of post and core to the stress distribution to the root of endodontically treated teeth. Material and methods: Mandibular first premolar, prepared by general shape of post and core with gold crown, was used to two dimensional axisymmetric modeling for finite element analysis. Then property values of 8 different kinds of post and core was substituted for each. Finally, stress distribution shown areas around the root of post and core was analysed after applying 50N of vortical and oblique load. Results: 1. Stress value of oblique load was much higher than the maximum stress value of vertical load. 2. Under oblique load, very concentrated stress was located on post periapical area and variations in stress were very severe. Contrary to this, stress distribution was relatively uniform in vertical load. 3. Post materials with higher elastic modulus showed relatively more apically focused stress, and post materials with lower elastic modulus showed stress focused on cervical area on the axial wall of post. 4. Stress change according to the properties of core was shown only in the cervical area of post and below core as the higher elastic modulus, then increased in stress. 5. Post and core with medium value of elastic modulus showed relatively uniform stress distribution. Conclusions: Post materials with higher elastic modulus showed relatively more apically focused stress, and post materials with lower elastic modulus showed stress focused on cervical area on the axial wall of post. Stress change according to the properties of core was shown only in the cervical area of post and below core.