• 제목/요약/키워드: Tooth reduction

검색결과 321건 처리시간 0.026초

전기 조향 장치용 BLDC 모터 내의 코깅 토크 저감을 위한 설계 기술 개발 (Design Techniques for reduction of Cogging Torque in Brushless DC Motors used for Electric Power Steering)

  • 황상문
    • 한국자동차공학회논문집
    • /
    • 제6권3호
    • /
    • pp.106-114
    • /
    • 1998
  • Cogging torque is often a principal source of vibration and control difficulty in permanent magnet motors, especially at low speeds and loads. For example, reduction of cogging torque is an important specification for DC motors used for electric power stee- ring. This paper examines two motor design techniques, stator tooth notching and rotor pole skewing with magnet pole shaping, for reduction of cogging torque, and the effect of each method on the airgap flux, and the use of the Maxwell stress method and Fourier decomposition to calculate the periodic cogging torque. The analyses show that the cogging torque can be nearly eliminated by the suggested designs, with minimal scacrifice of output torque.

  • PDF

영구자석형 모터의 프릭션 토크 저감을 위한 고정자 철심의 열처리 및 발생원 분석 (Heat Treatment of Stator Core in Permanent Magnet Type Motor for Reduction of Friction Torque and Analysis of Their Cause)

  • 하경호;임양수;권오열;김지현;김재관
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1752-1758
    • /
    • 2008
  • This paper deals with the reduction of friction torque in permanent magnet motors by using the heat treatment of stator core. The stator core is made of electrical steel sheared by the punching die. From the punching process, large mechanical stress acting on the edge of stator tooth induces significant plastic and elastic deformation and then cause the change of magnetization properties. Then, the mechanical and magnetic unbalance in the sheared region of stator tooth produced by material cutting has influence on the friction torque. This paper investigated the effect of the punching process on the magnetization process and the mechanical deformation, and then proposed the stress relief annealing method for the reduction of friction torque among one of motor characteristics.

피질골 절제술을 응용한 치아의 함입 이동 (Corticotomy and the Intrusive Tooth Movement)

  • 김상철;태기출
    • 대한치과교정학회지
    • /
    • 제33권5호
    • /
    • pp.399-405
    • /
    • 2003
  • 빠르며 정확하고 안전한 치아이동을 목표로 삼고 있는 교정치료에서 새로운 패러다임이라고 여겨지는 피질골 절제술과 견인 골형성술을 응용한 치아이동에 대하여 알아보았다. 일반적인 방법으로는 어렵거나 불가능하다고 여겨지는 치아의 함입 이동을 피질골 절제술과 견인 골형성술을 응용하여 도모하였다. 전치군 및 구치군 각각의 함입 이동 증례를 통해 피질골 절제술과 견인 골형성술의 적용 술식, 견인장치 등을 논하고 그 효과를 파악하였다. 빠른 치아이동과 이에 따른 교정치료 기간의 감소가 가능하고 기존의 교정치료로는 어려웠던 치아이동을 도모할 수 있었으며 무리한 치아이동 시 발생할 수 있는 치근 흡수나 치주조직의 파괴 같은 부작용도 줄일 수 있었다.

Esthetic rehabilitation of single anterior edentulous space using fiber-reinforced composite

  • Kim, Hyeon;Song, Min-Ju;Shin, Su-Jung;Lee, Yoon;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • 제39권3호
    • /
    • pp.220-225
    • /
    • 2014
  • A fiber-reinforced composite (FRC) fixed prosthesis is an innovative alternative to a traditional metal restoration, as it is a conservative treatment method. This case report demonstrates a detailed procedure for restoring a missing anterior tooth with an FRC. A 44-year-old woman visited our department with an avulsed tooth that had fallen out on the previous day and was completely dry. This tooth was replanted, but it failed after one year. A semi-direct technique was used to fabricate a FRC fixed partial prosthesis for its replacement. The FRC framework and the pontic were fabricated using a duplicated cast model and nanofilled composite resin. Later on, interproximal contact, tooth shape, and shade were adjusted at chairside. This technique not only enables the clinician to replace a missing tooth immediately after extraction for minimizing esthetic problems, but it also decreases both tooth reduction and cost.

Esthetic enhancement of a traumatized anterior tooth with a combination of forced eruption and tooth alignment: a case report

  • Kang, So-Hee;Ha, Jung-Hong;Jin, Myoung-Uk;Kim, Sung-Kyo;Kim, Young-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • 제41권3호
    • /
    • pp.210-217
    • /
    • 2016
  • Exposing sound structure of a subgingivally fractured tooth using orthodontic extrusion is considered to be a conservative way to re-establish biologic width without sacrificing esthetics or jeopardizing periodontal support of neighboring teeth. When a misaligned tooth is traumatically involved, a more comprehensive approach combining tooth extrusion and re-alignment may be necessary for a successful restorative outcome. This case report describes a successful esthetic management of a patient with complicated crown-root fracture on the maxillary right central incisor and pre-existing malocclusion in the maxillary anterior region. Forced eruption along with re-alignment of teeth by orthodontic movement seems to allow re-positioning of the fracture line to a favorable position and correction of crowding, providing a better esthetic result.

Orthodontic treatment for maxillary anterior pathologic tooth migration by periodontitis using clear aligner

  • Lee, Jun-Woo;Lee, Sang-Joon;Lee, Chang-Kyu;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • 제41권1호
    • /
    • pp.44-50
    • /
    • 2011
  • Purpose: Pathologic tooth migration (PTM) is a tooth displacement which is derived from imbalance of tooth retention force and is dominantly found out in maxillary anterior area. PTM in maxillary anterior area was tried to corrected with periodontal treatment and a clear aligner in this study and the result was evaluated clinically and radiographically. Methods: For the treatment of a patient with chronic periodontal disease accompanied by maxillary anterior pathologic tooth migration, clear aligner was applied to move teeth after a series of case-related periodontal therapy. Clinically, probing depth, gingival recession, clinical attachment level and mobility were measured pre- and post-treatment, and radiographic examination was performed as well. Results: Clinically, we found the decrease of the probing depth, gingival recession, clinical attachment level and mobility. And we could also acknowledge the reduction of vertical and horizontal dimension on infrabony defect radiographically. However, it is still controversial if there was an actual bone filling. Conclusions: Clear aligner is an effective appliance to move teeth since it costs little in terms of expense and time. In addition, it wraps whole crowns, providing advantages to deal with crowding, spacing, and size of arch. In short, clear aligner could be a useful treatment option for PTM patient, since it provides decreased probing depth, gingival recession, clinical attachment level, mobility and esthetical restoration.

Tooth Movement in Demineralized Area by Etchant in Rabbits

  • Choi, Bohm;Kim, Tae-Gun;Han, Seung-Hee;Park, Yoon-Hee;Lee, Won
    • Journal of Korean Dental Science
    • /
    • 제5권1호
    • /
    • pp.37-44
    • /
    • 2012
  • Purpose: Among the facilitation of tooth movement in adult orthodontic treatment methods, surgical approaches are gaining popularity but complications following mechanical bone reduction are a problem. In this study, tooth movement was observed after alveolar bone was chemically demineralized to verify whether tooth movement had been facilitated. Materials and Methods: Twelve rabbits were used. In the experimental group, the alveolar bone of the left first molar area was exposed and demineralized. Thirty seven percents phosphoric acid was applied for 5 minutes for demineralization. The opposite first molar area was used as control. Two teeth were pulled with 200 g force and 4 rabbits each were sacrificed at 3, 7, and 14 days after the force was applied. Histologic examination was done with hematoxylin and eosin and tartrate-resistant acid phosphatase staining. Result: The histologic examination results revealed more bone resorption in the demineralized area. As time passed, the number of osteoclasts increased in the compressed area. The amount of tooth movement was larger in the experimental group compared to the control group but the difference was not statistically significant. Conclusion: The demineralization with etchant resulted in limited bone resorption, more tooth movement and less damage of the cementum after applied orthodontic force.

Numerical study of the run-up of a solitary wave after propagation over a saw-tooth-shaped submerged breakwater

  • Sun, Jiawen;Ma, Zhe;Wang, Dongxu;Dong, Sheng;Zhou, Ting
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제12권1호
    • /
    • pp.283-296
    • /
    • 2020
  • A numerical model is established to investigate the run-up of a solitary wave after propagating over a triangular saw-tooth-shaped submerged breakwater. A rectangular-shaped submerged breakwater is simulated for comparison. Several factors, including the submerged depth, the lagoon length and the beach slope, are selected as independent variables. The free surface motions and velocity fields of the solitary wave interacting with the submerged breakwater are discussed. The results show that the submerged depth and lagoon length play significant roles in reducing the run-up. The influence of the beach slope is not significant. At the same submerged depth, the triangular saw-tooth-shaped submerged breakwater has only a slightly better effect than the rectangular-shaped submerged breakwater on the run-up reduction. However, a calmer reflected wave profile could be obtained with the rougher surface of the saw-tooth-shaped submerged breakwater. The study conclusions are expected to be useful for the conceptual design of saw-tooth-shaped submerged breakwaters.

박육직교축 치차의 설계에 관한 기초적 연구 (Study on the Design of Thin Intersected Axe Gear)

  • 장지연
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권3호
    • /
    • pp.80-87
    • /
    • 1993
  • The various configuration of thin-shaped bevel gears are used usually for such as main reduction gear of the hovercraft. But the reasonable and concise guide to thedesign of the se bevel gears is not yet obtained, since the tooth of bevel gear has complex form. The purpose of these investigation is to be establish the design guide and to propose the desirable configuration form for thin-shaped straight bevel gear. In this report, the desirable configuration is examined experimentally by clearing up the effect of web and rim thickness, rim support condition upon the load distribution and root stress distribution along the tooth trace. The results are summarized as follows. (1) The crowning of tooth trace exerts a significant effect on the root stress distribution of thin-shaped bevel gear. (2) As the desirable configuration of the thin-shaped bevel gear, it is to be recommended that the rim is supported at the heel side of tooth trace. (3) But, as special type, it is desirable that the rim is supported at the toe side.

  • PDF

유성기어 감속기에서 전위계수가 기어 강도에 미치는 영향 (The Effect of Addendum Modification Coefficient on Gear Strength to Planetary Gear Reducer)

  • 곽기석;한동섭
    • 한국기계가공학회지
    • /
    • 제10권4호
    • /
    • pp.38-43
    • /
    • 2011
  • Industrial reducer is in general use to Deck Crane. High-precision and high-efficient reducer is minimized the power-loss and energy-loss of a machine. So it contribute the price reduction and life extension. Reducer is usually using the Planetary gear reducer. Planetary gear reducer is composed the sun gear, planet gear, internal gear and casing. Industrial reducer's wear and breakage have a short-life. To solve this problem, it is using the profile-shifted-gear or tooth modification. This study was carried out the effect of addendum modification coefficient on tooth fillet bending strength to planetary reducer. Tooth fillet bending stress is calculate. And all parameter were expressed the function of addendum modification coefficient. And then stress concentration factor of tooth fillet curve was express the function of addendum modification coefficient using comparison between theory and finite element analysis.