• Title/Summary/Keyword: Tooth reduction

Search Result 319, Processing Time 0.026 seconds

Fracture load and survival of anatomically representative monolithic lithium disilicate crowns with reduced tooth preparation and ceramic thickness

  • Nawafleh, Noor A;Hatamleh, Muhanad M;Ochsner, Andreas;Mack, Florian
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.6
    • /
    • pp.416-422
    • /
    • 2017
  • PURPOSE. To investigate the effect of reducing tooth preparation and ceramic thickness on fracture resistance of lithium disilicate crowns. MATERIALS AND METHODS. Specimen preparation included a standard complete crown preparation of a typodont mandibular left first molar with an occlusal reduction of 2 mm, proximal/axial wall reduction of 1.5 mm, and 1.0 mm deep chamfer (Group A). Another typodont mandibular first molar was prepared with less tooth reduction: 1 mm occlusal and proximal/axial wall reduction and 0.8 mm chamfer (Group B). Twenty crowns were milled from each preparation corresponding to control group (n=5) and conditioned group of simultaneous thermal and mechanical loading in aqueous environment (n=15). All crowns were then loaded until fracture to determine the fracture load. RESULTS. The mean (SD) fracture load values (in Newton) for Group A were 2340 (83) and 2149 (649), and for Group B, 1752 (134) and 1054 (249) without and with fatigue, respectively. Reducing tooth preparation thickness significantly decreased fracture load of the crowns at baseline and after fatigue application. After fatigue, the mean fracture load statistically significantly decreased (P<.001) in Group B; however, it was not affected (P>.05) in Group A. CONCLUSION. Reducing the amount of tooth preparation by 0.5 mm on the occlusal and proximal/axial wall with a 0.8 mm chamfer significantly reduced fracture load of the restoration. Tooth reduction required for lithium disilicate crowns is a crucial factor for a long-term successful application of this all-ceramic system.

A Study on the Design and Experiment for the Profile of Lower-Noise Gear Tooth (저소음 치형의 설계 및 실험에 관한 연구)

  • 김호룡;안승준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.1
    • /
    • pp.1-10
    • /
    • 1993
  • A design method of gear tooth profile which can reduce the noise of gear is studied. The tooth profile is generated by combining involute and cycloid tooth curves in which the involute tooth profile is near the pitch point and cycloid tooth profile at the addendum and the dedendum. Considering parameters which have an influence on the reduction of gear noise and building up a design conditions for the noise reduction of gear, the lower-noise combined gear tooth profile is designed. For the check of noise reduction of the combined gear profile, two pairs of combined profile gear, two pairs of involute gear, and a pair of cycloid gear were manufactured by the NC Wire Cutting Machine, and the experiment for measuring of gear noise was carried out on each pair. The noise reduction of the combined profile gear was obtained.

Plaque Removing Efficacy and Effect on Gingival Inflammation of Newly Developed Tooth Cleansing Instrument (새롭게 개발된 치아청결기의 치태제거 및 치은염증에 대한 효과)

  • Han, Dong-Kwan;Pang, Eun-Kyung;Kim, Chan-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.3
    • /
    • pp.475-484
    • /
    • 2003
  • Many tooth cleansing instruments and agents have been developed for removal of plaque, inhibition of plaque formation and reduction of gingival inflammation. The aim of this study was to evaluate the plaque control effect and the therapeutic effect of newly developed tooth cleansing instrument(Belloblanco(R)). 40 healthy subjects with gingivitis or early periodontitis were divided into two groups. Subjects in control group only used manual tooth brushing and in experimental group used manual tooth brush and additive tooth cleansing instrument(Belloblanco(R)). Additive tooth cleansing instrument was used once a week. At baseline scaling and tooth brushing instruction was performed. Probing depth, bleeding on probing, plaque index, gingival index were scored at baseline, 2weeks, 4weeks. Probing depth of control and experimental group were significantly reduced at 2 weeks, 4weeks, hut there were no differences between two groups(P<(0.05). Bleeding on probing, plaque index and gingival index of control and experimental group were significantly reduced at 2weeks and 4weeks and there was significantly more reduction in the experimental group than the experimental group than the control group(p<(0.05). From these finding. it can be conclude that newly developed tooth cleansing instrument(Belloblanco(R)) are effective on the removal of plaque and the reduction of gingival inflammation

A Study on the Sliding Wear Rate Calculation in Spur Gears (Spur Gear의 미끄럼 마멸률에 관한 연구)

  • 김태완;문석만;구영필;조용주
    • Tribology and Lubricants
    • /
    • v.16 no.5
    • /
    • pp.357-364
    • /
    • 2000
  • In this study, the sliding wear in spur gears, using Archard's wear model, is analyzed. Formulas of tooth sliding wear depth along the line of action are derived. The tooth profile is modified Id make a smooth transmission of the normal loads and the cylinder profile for reducing the pressure spike is suggested. The sliding wear rate is calculated with these profiling results. We expect these modification methods to contribute to the reduction of sliding wear not only in the root, but the tip of tooth and tooth edge.

The Influence of Home Position(H.P.) and Random Position(R.P.) on the Shape of Prepared Tooth Surfaces -Upper Left 1st Molar for Full Cast Crown- (시술자세가 치관 삭제면 형태에 미치는 영향 -상악 좌측 제 1 대구치의 전부 주조관-)

  • Lee, Seung-Jeong;Choi, Dae-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.4
    • /
    • pp.257-274
    • /
    • 2001
  • To properly prepare teeth, dentists require a direct view of the working area and are often placed in a difficult position, moreover, a high proportion of dentists suffer from headache and back pain. Dentists who make use of the dental mirror and position their patients carefully to gain a proper view report less headache, pain and discomfort in the shoulders. It is recommended that dentists learn the "Home Position(H.P.)" which among the various "Random Position(R.P.)" methods, enables dentists to approach their patients in a stable posture. The purpose of this study was to compare tooth preparation in the H.P. and the R.P., and evaluate the clinical efficacy of the H.P.. Tooth preparation for a full cast crown was performed on the maxillary left 1st molar using the H.P. and the R.P., and the shapes of the prepared tooth surfaces at the two different operating positions were compared. The amount of occlusal reduction, marginal width, height, and axial taper were measured and analyzed. A T-test was performed separately to compare the results of the H.P. and the R.P. with respect to the accuracy of the corresponding tooth reduction. The results were as follows. ; 1. The amount of occlusal reduction was excessive on the mesiobuccal cusp(P<0.05), and deficient on the lingual cusp in the H.P.(P<0.01). In the R.P., this was excessive on the buccal cusp and deficient on the fossa and distolingual cusp(P<0.01). 2. The amounts of marginal width were excessive in all areas except on the lingual and mesial surfaces in the H.P. and lingual surface in the R.P.(P<0.01). 3. The marginal heights were achieved more accurately in the R.P. than the H.P.(P<0.01). 4. Axial surface taper was excessive in all areas in the H.P.(P<0.01). But the axial taper of measured areas was even, and tooth is more like to retain its original axis after reduction. In the R.P., axial surface taper was excessive on the mesial and buccal area, and deficient on the distolingual area(P<0.01), and therefore, the axis of the prepared teeth was tipped in the distolingual direction. 5. The times needed for preparation were 12 minutes and 49 seconds in the H.P., and 11 minutes and 35 seconds in the R.P., and the R.P. was statistically faster(P<0.01). The tooth preparation in the H.P. achieved its goal, in that it enabled the operator to make even tooth reduction. In conclusion, the H.P. system offers an improved method that can be used in clinic after specific training.

  • PDF

A Design on Reduction Cogging Torque of Dual Generator Radial Flux Permanent Magnet Generator for Small Wind Turbine

  • Lee, Gyeong-Chan;Jung, Tae-Uk
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1590-1595
    • /
    • 2013
  • In this paper, the design for an electromagnetic structure and reduction cogging torque of a dual generator structured RFPM generator, which is a combination of the inner- and outer-rotor types, has been proposed. We call this a dual generator radial flux permanent magnet generator. To reduce the cogging torque, firstly, stator tooth pairing was designed; secondly, stator displacement was designed and finally, stator tooth pairing and stator displacement were carried out simultaneously. We found the optimal design condition about stator tooth pairing angle combination and stator displacement angle for cogging torque minimization. As a result, a cogging was reduced by 93.3[%] by this study.

A study on design of spherical hob for internal gear hobbing (내접치차 가공용 구형 호브의 설계에 관한 연구)

  • 박천경;박동삼
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.6
    • /
    • pp.1312-1319
    • /
    • 1988
  • Internal gear is the important part of the planetary reduction gear system. This study aims at developing the numerical analysis method for design of spherical hob to manufacture internal gear. Methods of calculation of hob tooth profile, generating tooth profile and tooth profile errors such as the errors of pressure angle, tooth thickness and pitch of spherical hob must be made smaller than those of standard tooth profile. And, the smaller the pressure angle and the number of equivalent pinion tooth become, the larger the tooth profile errors are. One design example of spherical hob is proposed.

A comparative study of the improvement after different self-assessment methods of tooth preparation (치아 삭제의 다른 자가 평가 방법 후 개선에 대한 비교 연구)

  • Kim, JungHan;Son, Keunbada;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.4
    • /
    • pp.220-227
    • /
    • 2019
  • Purpose: The purpose of this study was to compare the degree of tooth preparation abilities of students according to three self-assessment methods. Materials and Methods: forty-eight sophomores in Kyungpook National University College of Dentistry were divided into three experimental groups. Students performed tooth preparation of the left mandibular first molar for full gold crown. They performed self-assessment using the three methods (visual, digital, and putty index self-assessment group), and reperformed tooth preparation. An intraoral scanner was used to scan each tooth model (prepared tooth and unprepared tooth), and data were acquired in standard tessellation language (STL) file format. The STL files of prepared tooth and unprepared tooth were superimposed using the 3-dimensional analysis software (Geomagic control X). And the reduction amount was measured. In the statistical analysis, all values of reduction amount were analyzed with the Wilcoxon signed rank test and Kruskal-Wallis test (α = 0.05). Results: The three self-assessment methods showed statistically significant differences (P < 0.001). The putty index self-assessment group showed the highest reduction in error than the digital self-assessment method. Conclusion: Within limitations of this study, students showed significant differences in improvement of tooth preparation ability according to the three self-evaluation methods.

On a Method for the Durability Enhancement of Plastic Spur Gear Using Finite Element Analysis (유한요소해석에 의한 플라스틱 스퍼기어의 내구성 향상방안 연구)

  • Kim, Choong-Hyun;Ahn, Hyo-Sok;Chong, Tae-Hyong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.2
    • /
    • pp.223-230
    • /
    • 2003
  • Stress patterns are created in the plastic spur gear tooth body by introducing a hole or a steel pin to improve stress distribution. Static analysis using finite element method is carried out to show the effect. The result shows that maximum stress as well as tooth tip displacement is dependent on the size and location of a hole or a steel pin. When a hole located on the tooth center line, the maximum static stress level and the tooth tip deflection is always higher than that of a solid gear. But, a considerable reduction in the maximum stress and tooth tip displacement is achieved by insertion of steel pin.

Optimization of the Tooth Surface in the Helical Gears Using a Response Surface Method (반응표면법을 이용한 헬리컬기어 치형수정의 최적화)

  • Park, Chan-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.760-763
    • /
    • 2005
  • Optimum design of the tooth surface for the reduction of transmission error is very difficult to determine analytically due to nonlinearity of transmission error under the several load condition. The design of tooth surface that can give a low noise under the various load condition is very important. Therefore, this study proposes the method to determine the optimal lead curve and robust design of the tooth surface by using the response surface method. To do so, the design variables are selected by a screening experiment. Then the fitted regression model Is built with the check of the usefulness of the model. The model with constraints is solved to obtain the optimum values for the lead curve and the robust design fur the tooth surface.

  • PDF