• 제목/요약/키워드: Tooth generation

검색결과 70건 처리시간 0.028초

Identification of Genetic Causes of Inherited Peripheral Neuropathies by Targeted Gene Panel Sequencing

  • Nam, Soo Hyun;Hong, Young Bin;Hyun, Young Se;Nam, Da Eun;Kwak, Geon;Hwang, Sun Hee;Choi, Byung-Ok;Chung, Ki Wha
    • Molecules and Cells
    • /
    • 제39권5호
    • /
    • pp.382-388
    • /
    • 2016
  • Inherited peripheral neuropathies (IPN), which are a group of clinically and genetically heterogeneous peripheral nerve disorders including Charcot-Marie-Tooth disease (CMT), exhibit progressive degeneration of muscles in the extremities and loss of sensory function. Over 70 genes have been reported as genetic causatives and the number is still growing. We prepared a targeted gene panel for IPN diagnosis based on next generation sequencing (NGS). The gene panel was designed to detect mutations in 73 genes reported to be genetic causes of IPN or related peripheral neuropathies, and to detect duplication of the chromosome 17p12 region, the major genetic cause of CMT1A. We applied the gene panel to 115 samples from 63 non-CMT1A families, and isolated 15 pathogenic or likelypathogenic mutations in eight genes from 25 patients (17 families). Of them, eight mutations were unreported variants. Of particular interest, this study revealed several very rare mutations in the SPTLC2, DCTN1, and MARS genes. In addition, the effectiveness of the detection of CMT1A was confirmed by comparing five 17p12-nonduplicated controls and 15 CMT1A cases. In conclusion, we developed a gene panel for one step genetic diagnosis of IPN. It seems that its time- and cost-effectiveness are superior to previous tiered-genetic diagnosis algorithms, and it could be applied as a genetic diagnostic system for inherited peripheral neuropathies.

인공치아의 임플란트 탈착을 위한 유도가열장치 연구 (Induction Heating Device for Dental Implant Removal)

  • 이상명;서영;송창우;이승엽
    • 대한기계학회논문집B
    • /
    • 제40권5호
    • /
    • pp.305-311
    • /
    • 2016
  • 유도가열은 유도전류를 이용하여 도체에 열을 가하는 방식이다. 유도가열은 열을 가하고자 하는 물체 내부에서 열이 발생하고, 비접촉이며 안전하기 때문에 산업이나 의료분야에서 광범위하게 사용되고 있다. 최근에 형상기억합금을 사용하여 열에 의해 인공치아가 임플란트에서 쉽게 빠질 수 있게 하는 임플란트 시스템이 개발되었다. 본 논문에서는 새로운 임플란트 시스템에서 인공치아를 쉽게 제거할 수 있는 유도가열 장치를 개발하였다. 먼저 전자장-열 구조 유한요소 연성 해석을 통해 다양한 입력 전류와 코일 형상에 대해 온도를 시뮬레이션 상으로 확인해보았다. 해석 결과를 토대로 유도가열장치 시작품을 제작하여 실험을 통해 86초에 인공 치아가 분리됨을 확인하였다.

가족력을 보이는 쇄골두개 이형성증에 관한 증례보고 (CLEIDOCRANIAL DYSPLASIA WITH FAMILIAL HISTORY - A CASE REPORT)

  • 황지영;최성철;이긍호;김광철;박재홍
    • 대한장애인치과학회지
    • /
    • 제4권2호
    • /
    • pp.82-87
    • /
    • 2008
  • 경희대학교 치과병원 소아치과에 내원한 3명의 환자는 외할어버지를 통해 격세 유전된 가족력을 가지고 있으며 임상 및 방사선 검사에서 관찰되는 특징들을 바탕으로 쇄골두개 이형성증으로 진단되었으나 쇄골의 기능과 형태적인 면에서 큰 변화는 나타나지 않았다. 쇄골두개 이형성증으로 인한 증상들은 환자마다 다양한 정도로 나타나므로 이 질환으로 인한 여러 가지 골격적 변화 및 특징들에 관한 기본적 지식을 가지는 것이 필요하며 비슷한 골격적 특징을 나타내는 다른 질환과의 감별진단도 필요하다. 더욱 정확한 진단을 위해서는 유전자검사 하는 것이 추천된다. 쇄골두개 이형성증 환자를 치료할 경우 기능적, 심미적으로 원만한 치료 결과를 위하여 적절한 시기에 과잉치를 발치 한 후 공간유지장치를 사용해야 하며 보철치료 및 교정치료 하는 것이 필요하다. 이를 위해 환자의 협조도와 더불어 여러 분야의 협진적 치료가 필요하다.

  • PDF

열순환이 상아질접착제 처리 후 미세누출에 미치는 영향에 관한 연구 (The Study of the Effect of Thermocycling on Microleakage within Various Dentin Bonding Agents)

  • 유승훈
    • 구강회복응용과학지
    • /
    • 제24권2호
    • /
    • pp.147-155
    • /
    • 2008
  • 5세대 상아질 접착제인 Adper Single bond 2.0 (3M-ESPE, USA), 6세대 상아질 접착제인 Prompt L-pop (3M-ESPE, USA), AdheSE (Ivoclar Vivadent, Liechtenstein) 를 각 상아질 접착제당 30개의 건전한 소구치 및 대구치를 선정하여 협면과 설면에 5급와동을 형성하고 복합레진을 적용하였다. 이중 절반은 열순환을 시행하지 않고 나머지 절반은 열순환을 시행하였다. 이후 메틸렌 블루를 침투시켜 시약의 침투 정도를 측정한 후 통계분석하였다. 열순환을 시행하지 않은 군과 열순환을 시행한 군을 통틀어 열순환을 시행하지 않은 상아질 군에서만 Single Bond 2.0의 미세누출의 양이 Prompt L-Pop과 AdheSE에 비하여 높았고 (p <.05) 나머지 군에서는 모두 Single Bond 2.0의 미세누출의 양이 적었다. (p <.05) 열순환 이후에 미세누출의 양이 늘어난 군은 Prompt L-Pop과 AdheSE의 상아질 군이었다.

5톤급 웜기어 감속기의 워엄기어와 케이싱의 최적설계 및 해석에 관한 연구 (Study on Optimal Design and Analysis of Worm Gear and Casing of 5 Ton Class Worm Gear Reducer)

  • 조성현;전창민;진진;김동선;류성기
    • 한국기계가공학회지
    • /
    • 제18권12호
    • /
    • pp.15-21
    • /
    • 2019
  • The worm reducer is capable of quadrature power transmission when the shafts are disposed at right angles to each other. Since a large reduction ratio can be obtained of up to approximately 1/100 and a sliding movement is performed during operation compared with other gears, the noise and vibration are small, and there is the advantage that reverse rotation can be prevented. On the other hand, severe wear and damage are displayed on the gear and worm tooth surface, and many defects, such as intense heat generation of the reducer, occur. In the reducer case, the four-piece casing method was selected to solve the problems of heat generation, transmission efficiency, and assemblability. In this paper, we analyzed the problems of the worm and worm wheel (the core parts of a 5-Ton worm reducer) and casing through these methods and researched how to solve them.

Numerical simulation of fully nonlinear sloshing waves in three-dimensional tank under random excitation

  • Xu, Gang;Hamouda, A.M.S.;Khoo, B.C.
    • Ocean Systems Engineering
    • /
    • 제1권4호
    • /
    • pp.355-372
    • /
    • 2011
  • Based on the fully nonlinear velocity potential theory, the liquid sloshing in a three dimensional tank under random excitation is studied. The governing Laplace equation with fully nonlinear boundary conditions on the moving free surface is solved using the indirect desingularized boundary integral equation method (DBIEM). The fourth-order predictor-corrector Adams-Bashforth-Moulton scheme (ABM4) and mixed Eulerian-Lagrangian (MEL) method are used for the time-stepping integration of the free surface boundary conditions. A smoothing scheme, B-spline curve, is applied to both the longitudinal and transverse directions of the tank to eliminate the possible saw-tooth instabilities. When the tank is undergoing one dimensional regular motion of small amplitude, the calculated results are found to be in very good agreement with linear analytical solution. In the simulation, the normal standing waves, travelling waves and bores are observed. The extensive calculation has been made for the tank undergoing specified random oscillation. The nonlinear effect of random sloshing wave is studied and the effect of peak frequency used for the generation of random oscillation is investigated. It is found that, even as the peak value of spectrum for oscillation becomes smaller, the maximum wave elevation on the side wall becomes bigger when the peak frequency is closer to the natural frequency.

DENTIN BONDING AGENTS들의 상아세관 밀봉 효과에 관한 연구 (STUDY ON DENTINAL TUBULES SEALING EFFECTS OF DENTIN BONDING AGENTS)

  • 권오택;박동수
    • Restorative Dentistry and Endodontics
    • /
    • 제18권2호
    • /
    • pp.483-496
    • /
    • 1993
  • Dentin hypersensitivity medicaments such as Gluma, Scotchbond 2, All-Bond 2, which are resin adhesives, were used to compare the sealing effects of dentinal tubule under mechanical stress. Topical application of above medicaments on the dentin surfaces of extracted teeth followed by artificial tooth brushing for 6 weeks was performed for the comparison. The following conclusions on the degree of dentinal tubule exposure versus time by were reached by using polyvinyl siloxane impression material for taking the impression, epoxy resin for the duplication and SEM for observing the surface. 1. SEM was used to compare the accuracy of the duplicated surface, but no differences were found when teeth samples and the duplicated surfaces were observed. 2. After comparing the degree of dentinal tubules exposure with varnish applied contrast group, resin adhesive materials showed much less exposure as time went by. 3. The results indicated that AU-Bond 2 adhesive, under mechanical stress, showed lesser exposure of dentinal tubules comparing with Gluma and Scotchbond 2 adhesives After the results were put together, it was demonstrated that resin replica method is an useful way to evaluate the treatment effects of the dentinal tubule hypersensitivity medicaments. Also, it was noticed that under mechanical stress, All-Bond 2, classified as fourth generation, illustrated the best dentinal tubules sealing effects.

  • PDF

Ti 합금의 고속가공시 밀링특성에 관한 연구 (High Speed Milling of Titanium Alloy)

  • Chen, Ming;Lee, Young-Moon;Yang, Seung-Han;Jang, Seung-Il
    • 한국공작기계학회논문집
    • /
    • 제12권5호
    • /
    • pp.34-39
    • /
    • 2003
  • The paper will present chip formation mechanism and surface integrity generation mechanism based on the systematical experimental tests. Some basic factors such as the end milling cutter tooth number, cutting forces, cutting temperature, cutting vibration the chip status, the surface roughness, the hardness distribution and the metallographic texture of the machined surface layer are involved. The chip formation mechanism is typical thermal plastic shear localization at high cutting speed with less number of shear ribbons and bigger shear angle than that at low speed, which means lack of chip deformation. The high cutting speed with much more cutting teeth will be beneficial to the reduction of cutting forces, enlarge machining stability mot depression of temperature increment anti-fatigability as well as surface roughness. The burrs always exist both at low cutting speed and at high cutting speed. So the deburring process should be arranged for milling titanium alloy in my case.

한국 성인의 구강건강 특성과 우울의 관련성 : 2021년 지역사회건강조사 자료분석 (Effect of oral health on depression : an analysis of the 2021 Korea Community Health Survey )

  • 신애리
    • 한국치위생학회지
    • /
    • 제23권5호
    • /
    • pp.395-402
    • /
    • 2023
  • Objectives: This study aimed to identify factors related to oral health and depression in Korean adults and contribute to the development of a mental health program to improve depression through oral health management. Methods: Data was obtained from the 2021 Korean Community Health Survey. The chi-square test was used to determine the differences in depression experience relative to general participant characteristics and their oral health. To determine the odds ratio and 95% confidence interval, multiple logistic regression analysis was used. All statistical analyses were performed using the SAS software (version 9.4). Results: The results suggest that depression may be influenced by gender, age, household generation, drinking habits, subjective health level, moderate to high exercise, breakfast, high blood pressure, diabetes, subjective oral health level, chewing discomfort, and tooth brushing. An increasing level of depression was associated with decreasing subjective oral health level (1.34 times), uncomfortable chewing (3.08 times), and frequency of toothbrushing after lunch or before going to bed (1.23 times and 1.58 times, respectively). Conclusions: Our study confirmed a close relationship between oral health and mental health. In developing health programs for improving depression, appropriate oral health care should be considered.

4종의 간접법용 복합 레진의 기계적 특성 비교 (COMPARISON OF MECHANICAL PROPERTIES IN 4 INDIRECT COMPOSITE RESIN)

  • 김길수;윤태호;송광엽;안승근
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.21-33
    • /
    • 2007
  • Statement of problem: The esthetic component of dental care has become increasingly more important, while new tooth-colored materials are continually marketed. Various new indirect composite materials have been developed with required advantages. The most recent development in the indirect composites has been the introduction of the second-generation laboratory composite or poly-glass materials. They are processed by different laboratory techniques based on combinations of heat, pressure, vacuum and light polymerization. Although, second generation products became available in 1995, their characteristics and clinical performance have not been adequately investigated. Purpose: The aim of this study was to measure the mechanical properties of the second generation indirect resin system and compare these with an existing universal direct composite resin. Material and method: In this study four indirect composite material (Adoro LC, BelleGlass HP, Tescera, Synfony) were tested for flexural strength, wear resistance, hardness and their degree of conversion against Z250, a light cure direct composite. Results: Within the limitations of this study, the following conclusions were drawn: 1. From the abrasion wear result, Adoro showed the least volume loss while Synfony showed the greatest volume loss. Z250 and BelleGlass HP didn't show significant difference (p>0.05), but they showed significant difference with other groups (p<0.05). From the attrition wear, BelleGlass HP showed the least volume loss and it didn’t show significant difference with Tescera (p>0.05). While Synfony showed the greatest volume loss that it showed significant difference with other groups (p>0.05). 2. Mean values of flexural strength by means of three point bending test was in the order of Z250, Adoro, Belleglass HP, Tescera and Synfony. Mean elastic modulus was in the order of Z250, BelleGlass HP, Tescera, Adoro and Synfony. 3. The result of Vicker‘s microhardness value showed that significantly higher value in Z250 (p<0.05), and is in the order of BelleGlass HP, Tescera, Adoro and Synfony. 4. The degree of conversion measured by FT-IR showed significantly higher value in BelleGlass HP (p<0.05), and is in the order of Adoro, Synfony, Tescera and Z250. Conclusion: Significant differences were found in the flexural strength, wear resistance, hardness and their degree of conversion.