• Title/Summary/Keyword: Tooth bone

Search Result 946, Processing Time 0.026 seconds

Efficacy of sonic-powered toothbrushes for plaque removal in patients with peri-implant mucositis

  • Lee, Jungwon;Lim, Jong Heun;Lee, Jungeun;Kim, Sungtae;Koo, Ki-Tae;Seol, Yang-Jo;Ku, Young;Lee, Yong-Moo;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.2
    • /
    • pp.56-61
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the effectiveness of powered toothbrushes for plaque control in patients with peri-implant mucositis, in comparison with manual toothbrushes. Methods: This randomized, prospective, controlled, clinical parallel study compared the efficacy of manual and powered toothbrushes for plaque control in implant restorations. Patients with bleeding on probing, no residual pocket depth (as indicated by a pocket probing depth ${\geq}5mm$), and no radiological peri-implant bone loss were eligible for this study. Patients were requested to complete a questionnaire describing their oral hygiene habits. The duration and frequency of tooth brushing were recorded by subjects in order to assess their compliance. Clinical parameters, including the modified plaque index (mPI), the modified sulcus bleeding index (mSBI), and clinical photographs (buccal and lingual views) were recorded at baseline and at one-month and two-month follow-up visits. Results: Statistically significant differences between patients who used manual toothbrushes and those who used powered toothbrushes were found regarding the frequency of tooth brushing per day and the duration of brushing at one-month and two-month follow-up visits, while no statistically significant differences were found relating to other oral hygiene habits. A statistically significant difference in patient compliance for tooth brushing was found at one month, while no difference was found at two months. Statistically significant decreases in the mPI and the mSBI were observed in both groups from baseline to the one- and two-month follow-ups. The overall reduction of these parameters was not significantly different between the two groups, except for mPI reduction between baseline and one month of follow-up. Conclusions: Sonic-powered toothbrushes may be a useful device for plaque control in patients with peri-implant mucositis.

Surgical Management of Dentigerous Cyst for Preserving Permanent Tooth Buds (영구치 보존을 고려한 함치성 낭종의 외과적 처치)

  • Park, Chanyoung;Park, Kitae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.1
    • /
    • pp.85-92
    • /
    • 2014
  • Dentigerous cyst is the most common developmental odontogenic cyst of the jaw which is associated with unerupted teeth. Treatment modalities range from enucleation to marsupialization. Enucleation is the process in which the cyst is completely removed, and this is usually indicated for smaller lesions. Larger cysts can be treated by marsupialization, which is a process that consists of making a surgical cavity on the wall of the cyst, emptying its content and maintaining the continuity between the cyst and the oral cavity. This procedure allows decompression of the cyst, regeneration of the bone-defected area, and also lets the wall of the cyst change into normal mucosa. This technique will protect adjacent structures and will promote spontaneous eruption of succedaneous teeth previously surrounded by the cyst. These are two case reports of a 5-year-old and an 11-year-old boy with dentigerous cysts found regarding supernumerary tooth and pulpotomized mandibular primary molars, respectively. Due to the large size of the cysts, both cases were treated with marsupialization. This case report shows that in cases regarding large-sized dentigerous cysts, marsupialization can be an effective surgical technique that promotes spontaneous eruption of cyst-involved succedaneous teeth and the preservation of adjacent teeth.

FINITE ELEMENT ANALYSIS OF STRESSES INDUCED BY OSSEOINTEGRATED PROSTHESES WITH OR WITHOUT CONNECT10N BETWEEN NATURAL TOOTH AND OSSEOINTEGRATED ABUTMENTS (골 유착성 임프란트 보철수복시 자연지대치와의 고정유무에 따른 유한요소법적 응력분석)

  • Ko, Heon-Ju;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.147-160
    • /
    • 1991
  • The purpose of this study was to examine, by the method of finite element analysis, how implant geometry with or without connection between natural tooth and osseointegrated abutments affected the stress distribution in surrounding bone and osseointegrated prosthesis. The mandibular first and second molars were removed and the two osseointegrated implants were placed in the first and second molar sites. Stress analysis induced by prostheses with connection(Model A)or without connection(Model B) between natural tooth(second bicuspid) and two osseointegrated abutments(first molar and second molar) was performed under vertical point load(Load P1) or distributed point load(Load P2). The results were as follows; 1. Under vertical point load, mesial tilting was shown in both Model A and Model B and inferior displacement of Model A was greater than that of Model B in the second bicuspid. 2. Under vortical point load, the first and second molars showed mesial tilting in both Model A and Model B, and inferior displacement of them was similar in Model A and Model B and was less than that of the second bicuspid. 3. Under distributed point load, mesial displacement was shown in Model A and Model B and inferior displacement of Model A was less than that of Model B in the second bicuspid. 4. Under distributed point load, mesial tilting was shown and inferior displacement of Model A was similar to that of Model B in the first and second molars. 5. In Model A under vertical point load, high stress was concentrated in the corneal portion of first molar and distributed throughout the second molar and the second bicuspid, and the stress distribution of the second molar was greater than that of the second bicuspid. 6. In Model B under vertical point load, high stress was concentrated in the coronal and mesio-cervical portion of the first molar. 7. In Model A under distributed point load, high stress was concentrated in the mesio-cervical portion of the first molar and evenly distributed throughout the second molar and the second bicuspid. 8. In Model B under distributed point load, high stress was concentrated in the disto-cervical portion of the second bicuspid and evenly distributed throughout the first and second molars.

  • PDF

INTENTIONAL REPLANTATION OF CROWN-ROOT FRACTURED TOOTH WITH OPEN APEX (의도적 재식술을 이용한 치관-치근 파절된 미성숙영구치의 치험례)

  • Ryu, Jung-A;Lee, Jae-Ho;Choi, Byung-Jai;Son, Heung-Kyu;Choi, Hyung-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.267-272
    • /
    • 2004
  • This case report describes an uncommon treatment method for crown-root fractured incisor with immature root. A 7-year-old girl was referred for treatment of crown-root fractured maxillary central incisor. The fracture line extended to 1/2 of the total tooth length with incomplete root formation. The prognosis of crown-root fracture is usually poor and extraction is usually undertaken. But, in the mixed dentition, extraction of maxillary permanent incisor results in many complications, such as resorption of alveolar bone, poor esthetics, pronunciation and mastication. Conservative therapy in the permanent dentition comprises of few treatment modalities; supragingival restoration, gingivectomy, orthodontic extraction of apical fragment, surgical extrusion of apical fragment with or without rotational replantation. However, in this case, these indications are not applicable, so intentional replantation with adhesive resin system is the treatment of choice. The tooth was followed-up for 12 months. Currently, there are no symptoms. Since this modality adopts the respective advantages of both intentional replantation and adhesive treatment, it might be the treatment of choice in cases of vertical crown-root fracture.

  • PDF

THE STUDY ON THE DEVELOPMENT OF RELATIVE VALUE IN MEDICAL TREATMENT OF THE ORAL AND MAXILLOFACIAL SURGERY (구강악안면외과 의료행위 상대가치 개발에 대한 조사연구)

  • Song, Gin-Ah;Baek, Kyung-Won;Hwang, Jong-Min;Yu, Soon-Yong;Choi, Jin-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.4
    • /
    • pp.334-347
    • /
    • 2006
  • The aim of this study is to evaluate the reasonableness of the medical fee on oral and maxillofacial surgery field according to surgeon's opinions and actual conditions. The medical fee has significant influence on hospital income, the supply and distribution of medical manpower, quality and facilities of medical services. Questionnaire survey was sent to 86 oral and maxillofacial surgeons who worked more than 3 years in general hospital. Among them, 25 doctors replied the 109 answers survey and the average of treatment time and physician work relative value on each category was calculated. And the health insurance cost (that has been applied since 2003) was compared with the questionnaire results. And finally we investigated items that health insurance system did not include in oral and maxillofacial field but actually performed in oral and maxillofacial surgery clinic. The result was that the medical fee did not properly reflect physician work relative value of actual treatments. In case of complicated extraction, work relative value needed 3.5 times enhancement of present value. For simple impacted tooth extraction 1.8 times, for impacted tooth extraction including odontomy 1.7 times, and for fully impacted tooth more than 2/3 of it located into the alveolar bone, 1.8 times enhancement needed. In respect of the present physician work relative value, hemimandibulectomy with neck lymph node dissection for the malignancy is appropriated as 3.3 times of open reduction and internal fixation for the mandibular fracture, but the questionnaire result showed 25 times discrepancy. In conclusion, this research shows the need for intervention that health insurance included items and legal relative medical value must act in union with treatment in clinic to reduce the imbalance between them.

Rehabilitation with implant-supported fixed dental prostheses using digital duplication technique on customized artificial tooth, interim denture and implant surgical template: A case report (디지털 복제로 만든 맞춤형 인공치로 제작한 임시의치와 임플란트 수술용 템플릿을 통한 임플란트 지지형 고정성 보철 수복 증례)

  • Jeong, Dae Gil;Oh, Kyung Chul;Shim, June Sung;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.397-404
    • /
    • 2019
  • Bone and soft tissue conditions are important for successful implant treatment. But, the placement itself is also very important. Implants which is installed in the wrong position result in the biological, esthetical and mechanical problems. In order to place an implant in the correct position, the final restoration and diagnostic wax-up should be considered prior to the surgery. If the artificial teeth for the interim denture are directly transferred from the diagnostic wax-up, the operator can try the form of diagnostic wax-up in the mouth. If the surgical template is produced by duplicating the interim denture, the implant can be placed in the planned position. In this case, the polymethyl methacrylate (PMMA) artificial tooth was precisely milled by the digital duplication of diagnostic wax-up. And interim denture was fabricated by using these milled teeth. After the patient adapted for a sufficient period, the implant was placed at the planned position with surgical template produced by duplicating the interim denture. After confirming sufficient osseointegration, the final prostheses were made to reflect the shape of diagnostic wax-up. Through this procedure, the satisfactory functional and esthetic outcome could be acquired.

A safe, stable, and convenient three-dimensional device for high Le Fort I osteotomy

  • Sugahara, Keisuke;Koyachi, Masahide;Odaka, Kento;Matsunaga, Satoru;Katakura, Akira
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.32.1-32.4
    • /
    • 2020
  • Background: Le Fort I osteotomy is a highly effective treatment for skeletal jaw deformities and is commonly performed. High Le Fort I osteotomy is a modified surgical procedure performed for improving the depression of the cheeks by setting the osteotomy higher than the conventional Le Fort I osteotomy. Developments in three-dimensional (3D) technology have popularized the use of 3D printers in various institutions, especially in orthognathic surgeries. In this study, we report a safe and inexpensive method of performing a high Le Fort I osteotomy using a novel 3D device and piezosurgery, which prevent tooth root injury without disturbing the operation field for patients with a short midface and long tooth roots. Results: A 17-year-old woman presented with facial asymmetry, mandibular protrusion, a short midface, and long tooth roots. We planned high Le Fort I osteotomy and bilateral sagittal split ramus osteotomy. Prevention of damage to the roots of the teeth and the infraorbital nerve and accurate determination of the posterior osteotomy line were crucial for clinical success. Le Fort I osteotomy using 3D devices has been reported previously but were particularly large in size for this case. Additionally, setting the fixing screw of the device was difficult, because of the risk of damage to the roots of the teeth. Therefore, a different surgical technique, other than the conventional Le Fort I osteotomy and 3D device, was required. The left and right parts of the 3D device were fabricated separately, to prevent any interference in the surgical field. Further, the 3D device was designed to accurately cover the bone surface from the piriform aperture to the infra-zygomatic crest with two fixation points (the anterior nasal spine and the piriform aperture), which ensured stabilization of the 3D device. The device is thin and does not interfere with the surgical field. Safe and accurate surgical performance is possible using this device and piezosurgery. The roots of the teeth and the infraorbital nerve were unharmed during the surgery. Conclusions: This device is considerably smaller than conventional devices and is a simple, low-cost, and efficient method for performing accurate high Le Fort I osteotomy.

Effects of bisphosphonate and indomethacin on alveolar bone remodeling in rats (Bisphosphonate와 Indomethacin이 백서 치조골의 골개조에 미치는 영향)

  • Cho, Myeong-Sook;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.26 no.2 s.55
    • /
    • pp.163-174
    • /
    • 1996
  • The purpose of this study was to examine the effects of bisphosphonate and indomethacin, blockers of bone resorption with different mechanisms, on alveolar bone remodeling. Male rats were divided into control, bisphosphonate and indomethacin groups, and then each group was divided info an experimental side and a control side according to the force application. Bisphosphonate(6.3mg/kg,$2.52x10^{-2}mol/L$) and indomethacin (9mg/kg, $2.52x10^{-2}mol/L$) were injected 6 hours and 1 hour before or 24 hours after the force application. The rats were killed 72 hours after the force application and histologic examination was perfomed. The values of serum acid phosphatase and lactate dehydrogenase were also measured in the control md experimental groups treated with bisphosphonate or indomethacin 1 hour before the force application. In the experimental side, the least number of osteoclasts was noted in the groups treated 1 hour before the force application with indomethacin or bisphosphonate, while there were no differences between the control and the groups treated with drugs 6 hours before or 24 hours after the force application. In the control side, the number of osteoclasts was not inecreased with no differences among the groups. Histologic examination revealed a severe alveolar bone resorption in the control group and the groups treated with indomethacin 6 hours before or 24 hours after the force application. Indomethacin treatment 1 hour before the force application and bisphosphonate treatment at any time significantly attenuated the bone resorption. Electron microscopically, ruffled border and clear zone of osteoclasts were observed in the control and indomethacin groups, while some osteoclasts were detached from the bone surface and exhibited dull cellular projections in the bisphosphonate groups. The bisphosphonate and indomethacin groups showed lower values of acid phosphatase and lactate dehydrogenase than the control group. The acid phosphatase value in the bisphosphonate group was lower than that in the indomethacin group, whereas there was no difference in the lactate dehydrogenase value between the groups. These results suggest that bisphosphonate reduces the activity of osteoclasts as well as the number of osteoclasts and that indomethacin reduces the number of osteoclasts without affecting the activity of osteoclasts. Bisphosphonate has a larger inhibitory effect on bone resorption md thus less limitation in the application time than indomethacin.

  • PDF

EFFECT OF NUMBER OF IMPLANTS AND CANTILEVER DESIGN ON STRESS DISTRIBUTION IN THREE-UNIT FIXED PARTIAL DENTURES: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS

  • Park, Ji-Hyun;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.290-297
    • /
    • 2008
  • STATEMENT OF PROBLEM: Implant-supported fixed cantilever prostheses are influenced by various biomechanical factors. The information that shows the effect of implant number and position of cantilever on stress in the supporting bone is limited. PURPOSE: The purpose of this study was to investigate the effect of implant number variation and the effect of 2 different cantilever types on stress distribution in the supporting bone, using 3-dimensional finite element analysis. MATERIAL AND METHODS: A 3-D FE model of a mandibular section of bone with a missing second premolar, first molar, and second molar was developed. $4.1{\times}10$ mm screw-type dental implant was selected. 4.0 mm height solid abutments were fixed over all implant fixtures. Type III gold alloy was selected for implant-supported fixed prostheses. For mesial cantilever test, model 1-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 1-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 1-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with mesial cantilever were simulated. And then, 155N oblique force was applied to the buccal cusp of second premolar. For distal cantilever test, model 2-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 2-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 2-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with distal cantilever were simulated. And then, 206N oblique force was applied to the buccal cusp of second premolar. The implant and superstructure were simulated in finite element software(Pro/Engineer wildfire 2.0). The stress values were observed with the maximum von Mises stresses. RESULTS: Among the models without a cantilever, model 1-1 and 2-1 which had three implants, showed lower stress than model 1-2 and 2-2 which had two implants. Although model 2-1 was applied with 206N, it showed lower stress than model 1-2 which was applied with 155N. In models that implant positions of models were same, the amount of applied occlusal load largely influenced the maximum von Mises stress. Model 1-1, 1-2 and 1-3, which were loaded with 155N, showed less stress than corresponding model 2-1, 2-2 and 2- 3 which were loaded with 206N. For the same number of implants, the existence of a cantilever induced the obvious increase of maximum stress. Model 1-3 and 2-3 which had a cantilever, showed much higher stress than the others which had no cantilever. In all models, the von Mises stresses were concentrated at the cortical bone around the cervical region of the implants. Meanwhile, in model 1-1, 1-2 and 1-3, which were loaded on second premolar position, the first premolar participated in stress distribution. First premolars of model 2-1, 2-2 and 2-3 did not participate in stress distribution. CONCLUSION: 1. The more implants supported, the less stress was induced, regardless of applied occlusal loads. 2. The maximum von Mises stress in the bone of the implant-supported three unit fixed dental prosthesis with a mesial cantilever was 1.38 times that with a central pontic. The maximum von Mises stress in the bone of the implant-supported three-unit fixed dental prosthesis with a distal cantilever was 1.59 times that with a central pontic. 3. A distal cantilever induced larger stress in the bone than a mesial cantilever. 4. A adjacent tooth which contacts implant-supported fixed prosthesis participated in the stress distribution.

The influence of Advanced Adult Periodontitis on the pulp (진행성 치주염이 지수 조직에 미치는 영향)

  • Lee, Kang-Woon;Lee, Chel-Woo;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.95-102
    • /
    • 1999
  • The purpose of this study was to observe histopathologically the influence of advanced periodontitis on pulp tissue, and to conclude the correlation between the results with clinical manifestations. The samples were teeth with over 7mm pocket depth and over 50% radiographic bone loss. These were diagnosed to have very poor prognosis and thus planned to be extracted. Those with any of following conditions were excluded from the samples, loss of vitality, periapical pathology, restoration or prosthesis, dental caries, and attrition or abrasion. It was because these conditions could affect pulp without any correlation with periodontal disease. For the experiment, 17 teeth from 11 patients were selected. Average age of patient was 47. Each tooth was examined for following categoris; pocket depth, gingival recession, electric pulp test, mobility, percussion test, sensitivity test. The extracted teeth were fixed buffered neutral formalin solution. It was decalcified using 4% nitric acid. Sliced histological samples observed using light microscope, for pulp status, and severeity of inflammation. 4 samples were excluded due to histologic sample discrepency. Thus 13 samples were subject to observation. 4 showed normal conditions. Focal reversable pulpitis was shown in 5 samples. Chronic pulpitis was observed 1 sample. Pulpal abscess was observed in 3 samples.

  • PDF