• 제목/요약/키워드: Tooth Thickness

검색결과 241건 처리시간 0.03초

가공오차 및 조립오차가 유성기어열의 정특성에 미치는 영향 (Influence of Manufacturing and Assembly Errors on The Static Characteristics of Epicyclic Gear Trains)

  • 오재국;천길정
    • 대한기계학회논문집A
    • /
    • 제27권9호
    • /
    • pp.1597-1606
    • /
    • 2003
  • Static analysis using hybrid finite element(FE) method has been applied to characterize the influence of position, runout and thickness errors of the sun, ring and planet on the bearing forces and critical tooth stress. Some guidelines for tolerance control to manage critical stress and bearing forces are deduced from the results. Carrier indexing error planet assembly and planet tooth thickness error are most critical to reduce planet bearing force and maximize load sharing as well as to reduce critical stresses. Sun and carrier bearing forces due to errors increase several times more than those of normal condition.

치관 전장용 레진의 내마모성에 대한 비교연구 (A COMPARATIVE STUDY ON THE WEAR RESISTANCE OF POLYMERIC VENEERING MATERIALS)

  • 윤수선;이선형;양재호;장완식
    • 대한치과보철학회지
    • /
    • 제24권1호
    • /
    • pp.33-43
    • /
    • 1986
  • The purpose of this study was to compare the wear resistance of heat pressure-cured microcomposite(SR-Isosit-N), photo-cured microcomposite(Dentalcolor), unfilled heat-cured resin(Thermojel) and that of human enmel. Specimens were made with specially designed die and finally polished with #3,000 diamond paste. After 100,000 strokes of tooth brushing at electric tooth-brushing machine, mean thickness loss of each specimen was measured by using surface profile and integration. The results were as follows 1. Mean thickness loss were $84.3{\pm}27.3{\mu}m$ in unfiled heat-cured resin, $9.4{\pm}2.5{\mu}m$ in photocured microcomposite, $7.6{\pm}2.1{\mu}m$ in heat.pressure-cured microcomposite and $0.97{\pm}0.42{\mu}m$ in enamel. 2. Heat.pressure-cured microcomposite and photo-cured microcomposite had no difference in mean thickness loss(p>0.05). 3. Unfilled resin and microcomposite had much differences in mean thickness loss (p<0.005). 4. ha resins used in this experiment had too much mean thickness loss as compared with enamel (p<0.005).

  • PDF

가시광선(可視光線)의 치질투과(齒質透過) 후(後) 복합(複合)레진 경도(硬度)에 미치는 영향(影響)에 관(關)한 연구(硏究) (A STUDY ON THE CURING EFFECT OF COMPOSITE RESIN BY VISIBLE LIGHT THROUGH TOOTH SUBSTANCE)

  • 방상훈;박상진;민병순;최호영
    • Restorative Dentistry and Endodontics
    • /
    • 제12권1호
    • /
    • pp.85-93
    • /
    • 1986
  • The purpose of this study was to investigate the curing effect of visible light through tooth substance, 0.5mm, 1.0mm thickness of enamel and dentin were prepared. Experimental specimen were made by Bisfil M & Silux packing into cylindrical brass mold 6.0mm in diameter, 2.0mm and 3.0mm, in height. All specimen were irradiated by visible light (Grip type) model No. SDL-50 Shofu Co.) for 30 seconds through tooth substance. Experimental groups were classified into enamel group (group 1) and dentin group (group 2) according to the thickness of tooth materials and then were divided into 2 subgroups (0.5mm group and 1.0mm group). In experimental groups, visible light irradiated to the specimen through either 0.5mm in thick or 1.0mm in think of tooth material. In Control group specimen were prepared by direct irradiation on the specimen surface of visible light without through tooth substance. The hardness was measured with a Barcol hardness tester (Barber-Colman Co. U.S.A.) for each prepared specimen. The results were as follows: 1. In control group, there were higher hardness values than those of in experimental group. 2. In experimental groups, 0.5mm groups had higher hardness values than 1.0mm groups did. 3. The hardness value at top surface of the specimen were higher than the hardness of bottom surface in each group. 4. Bisfil M had higher hardness values than Silux. 5. In all specimen of 3.0mm height polymerization effect was not occurred at bottom surface except Bisfil M in control group.

  • PDF

Radiographic evaluation of the symphysis menti as a donor site for an autologous bone graft in pre-implant surgery

  • Bari, Roberto Di;Coronelli, Roberto;Cicconetti, Andrea
    • Imaging Science in Dentistry
    • /
    • 제43권3호
    • /
    • pp.135-143
    • /
    • 2013
  • Purpose: This study was performed to obtain a quantitative evaluation of the cortical and cancellous bone graft harvestable from the mental and canine regions, and to evaluate the cortical vestibular thickness. Materials and Methods: This study collected cone-beam computed tomographic (CBCT) images of 100 Italian patients. The limits of the mental region were established: 5 mm in front of the medial margin of each mental foramen, 5 mm under the apex of each tooth present, and above the inferior mandibular cortex. Cortical and cancellous bone volumes were evaluated using SimPlant software (SimPlant 3-D Pro, Materialize, Leuven, Belgium) tools. In addition, the cortical vestibular thickness (minimal and maximal values) was evaluated in 3 cross-sections corresponding to the right canine tooth (3R), the median section (M), and the left canine tooth (3L). Results: The cortical volume was $0.71{\pm}0.23mL$ (0.27-1.96 mL) and the cancellous volume was $2.16{\pm}0.76mL$ (0.86-6.28 mL). The minimal cortical vestibular thickness was $1.54{\pm}0.41mm$ (0.61-3.25 mm), and the maximal cortical vestibular thickness was $3.14{\pm}0.75mm$ (1.01-5.83 mm). Conclusion: The use of the imaging software allowed a patient-specific assessment of mental and canine region bone availability. The proposed evaluation method might help the surgeon in the selection of the donor site by the comparison between bone availability in the donor site and the reconstructive exigency of the recipient site.

박육직교축 치차의 설계에 관한 기초적 연구 (Study on the Design of Thin Intersected Axe Gear)

  • 장지연
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권3호
    • /
    • pp.80-87
    • /
    • 1993
  • The various configuration of thin-shaped bevel gears are used usually for such as main reduction gear of the hovercraft. But the reasonable and concise guide to thedesign of the se bevel gears is not yet obtained, since the tooth of bevel gear has complex form. The purpose of these investigation is to be establish the design guide and to propose the desirable configuration form for thin-shaped straight bevel gear. In this report, the desirable configuration is examined experimentally by clearing up the effect of web and rim thickness, rim support condition upon the load distribution and root stress distribution along the tooth trace. The results are summarized as follows. (1) The crowning of tooth trace exerts a significant effect on the root stress distribution of thin-shaped bevel gear. (2) As the desirable configuration of the thin-shaped bevel gear, it is to be recommended that the rim is supported at the heel side of tooth trace. (3) But, as special type, it is desirable that the rim is supported at the toe side.

  • PDF

Analysis of crown size and morphology, and gingival shape in the maxillary anterior dentition in Korean young adults

  • Song, Jae-Won;Leesungbok, Richard;Park, Su-Jung;Chang, Se Hun;Ahn, Su-Jin;Lee, Suk-Won
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권4호
    • /
    • pp.315-320
    • /
    • 2017
  • PURPOSE. The aim of this investigation was to analyze the dimensions of clinical crowns and to classify the crown and the gingival type in the anterior teeth in Korean young adults. MATERIALS AND METHODS. Casts were obtained from 50 subjects ranging in age from 24 to 32. Measurements of length and width were made on the casts using a pair of digital calipers on the entire dentition. Crown thickness and papilla height were also measured and MDW/CL (mesiodistal width to clinical length) and CW/CL (cervical width to clinical length) ratios of the maxillary anterior teeth were calculated. The K-clustering method was used for CW/CL to classify the anterior tooth shape into three groups (tapered, ovoid, and square), and one-way analysis of variance and Duncan's post-hoc comparison were used to evaluate statistical significance between the groups. Pearson's correlation analysis was performed between tooth shape and papillary height (PH) to demonstrate the correlation between tooth shape and gingival morphological characteristics. RESULTS. The average length of the maxillary central incisors was 9.89 mm; the mesio-distal width was 8.54 mm; and the ratio of width/length was 0.86 in Korean young adults. The average bucco-palatal thickness of the central incisor was 3.14 mm at the incisal 1/3 aspect. Ovoid type was the most common tooth shape (48%), followed by square type (29%) and taper type (23%) in the central incisors of Korean young adults. Tooth shape and gingival type were correlated with each other. CONCLUSION. New reference data were established for tooth size in Korean young adults and the data show several patterns of tooth shape and gingival type. Clinicians should diagnose and treat based on these characteristics for better results in the Korean population.

Endodontic approach in a replanted tooth with an immature root apex and chronic apical periodontitis: a case report

  • Mori, Graziela Garrido;Andrade, Bruna Souza;Araujo, Marina Bardelli
    • Restorative Dentistry and Endodontics
    • /
    • 제45권3호
    • /
    • pp.29.1-29.9
    • /
    • 2020
  • This study describes the clinical steps taken in the treatment of a patient who had an avulsed right upper central incisor that presented with incomplete root development and chronic apical periodontitis. A 7-year-old boy was referred from a private dentist to a dental office specializing in endodontics. The tooth had remained in a dry environment for 20 minutes, and tooth replantation was performed at an emergency appointment. After clinical and radiographic examinations, root canal decontamination was performed, followed by several changes in intracanal calcium hydroxide medication. Blood clot formation was attempted, but bleeding within the root canal was insufficient; therefore, we opted for an intracanal medication change to stimulate mineralized tissue formation in the apical region. Root obturation was performed 45 days after the last change of intracanal medication, and clinical, radiographic, and tomographic follow-up examinations were performed at 3, 6, 18, and 40 months after the endodontic intervention. The increase in thickness and length of the root structure and the absence of root resorption were verified through follow-up examinations. Therefore, it was concluded that the procedures used were successful for tooth replantation.

Assessment of buccal bone thickness of aesthetic maxillary region: a cone-beam computed tomography study

  • Fuentes, Ramon;Flores, Tania;Navarro, Pablo;Salamanca, Carlos;Beltran, Victor;Borie, Eduardo
    • Journal of Periodontal and Implant Science
    • /
    • 제45권5호
    • /
    • pp.162-168
    • /
    • 2015
  • Purpose: The aim of this study was to analyze the anatomical dimensions of the buccal bone walls of the aesthetic maxillary region for immediate implant placement, based upon cone-beam computed tomography (CBCT) scans in a sample of adult patients. Methods: Two calibrated examiners analyzed a sample of 50 CBCT scans, performing morphometric analyses of both incisors and canines on the left and right sides. Subsequently, in the sagittal view, a line was traced through the major axis of the selected tooth. Then, a second line (E) was traced from the buccal to the palatal wall at the level of the observed bone ridges. The heights of the buccal and palatal bone ridges were determined at the major axis of the tooth. The buccal bone thickness was measured across five lines. The first was at the level of line E. The second was at the most apical point of the tooth, and the other three lines were equidistant between the apical and the cervical lines, and parallel to them. Statistical analysis was performed with a significance level of $P{\leq}0.05$ for the bone thickness means and standard deviations per tooth and patient for the five lines at varying depths. Results: The means of the buccal wall thicknesses in the central incisors, lateral incisors and canines were $1.14{\pm}0.65mm$, $0.95{\pm}0.67mm$ and $1.15{\pm}0.68mm$, respectively. Additionally, only on the left side were significant differences in some measurements of buccal bone thickness observed according to age and gender. However, age and gender did not show significant differences in heights between the palatal and buccal plates. In a few cases, the buccal wall had a greater height than the palatal wall. Conclusions: Less than 10% of sites showed more than a 2-mm thickness of the buccal bone wall, with the exception of the central incisor region, wherein 14.4% of cases were ${\geq}2mm$.

골다공증의 파노라마방사선사진상 진단학적 매개변수에 관한 연구 (THE STUDY ABOUT THE DIAGNOSTIC PARAMETERS OF OPSTEOPOROSIS ON PANORAMIC RADIOGRAPH)

  • 이용규
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제20권4호
    • /
    • pp.279-283
    • /
    • 1998
  • The osteoporosis is a disease that represents a reduction in the volume of bony tissue relative to whole bone volume. And mandible also may be affected. Such porotic mandible may influence the result of the surgery like dental implant surgery relating mandible. So, the author examed the panoramic view of 89 persons for finding the possibility of useful diagnostic parameters of osteoporosis. To know the correlationship between the condition of vertebra and mandible, bone marrow density of lumbar spine from 2nd to 4th, and the number of residual tooth, panoramic mandibular index (PMI), angular cortical bone thickness (ACT) and ramus cortical bone thickness (RCT) were compared. The result is that PMI and ACT have similar relative weak linear correlationship, RCT have very weak linear correlationship, the number of residual tooth have not linear correlationship.

  • PDF

복합 레진으로 수복된 세 가지 첨와형태 와동의 파절 저항성에 관한 연구 (FRACTURE RESISTANCE OF THE THREE TYPES OF UNDERMINED CAVITY FILLED WITH COMPOSITE RESIN)

  • 최훈수;신동훈
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2008년도 Spring Scientific Meeting(the 129th) of Korean Academy if Conservative Dentistry
    • /
    • pp.177-183
    • /
    • 2008
  • 심미성 복합레진은 자연 치질을 보존시키며 나아가 잔존 치질의 강도를 강화시켜 준다. 복합레진 수복시 더 많은 치질을 남기기 위해 첨와 (undercut) 형태의 교합면 치질을 남긴 채 복합레진으로 수복하는 경우가 많으나, 어느 정도 강도가 복원되는지에 대해서는 잘 알려져 있지 않다. 이에 본 연구에서는 첨와 형태의 와동을 잔존치질의 두께 (법랑질 /법랑질과 상아질)에 따라 형성하고 복합레진으로 충전한 경우, 수복된 치아의 파절 저항성을 손상이 없는 자연치와 비교 평가하였다. 상악 대구치 40개의 교합면을 편평하게 삭제한 후 방사선 사진에서 치수각의 위치를 확인하였다. 대상 치아를 각 10개씩 4개군으로 분류하였으며, $1{\sim}3$군은 실험군으로 모두 협측에 깊이 7 mm, 근원심 폭경 5 mm의 첨와 형태 와동을 형성하였고, 와동저에서 치수각까지의 거리를 약 0.5 mm로 유지하였으며 교합면쪽의 치질 두께를 달리하였다. 1군은 법랑질과 소량의 상아질로 구성된 치질 두께를 1 mm, 2군은 법랑질과 상아질의 두께를 1.5 mm, 3군은 법랑질과 상아질의 두께를 2 mm가 되도록 하였고, 4군은 건전한 자연치를 와동형성 없이 대조군으로 사용하였다. 두께 측정은 방사선 사진을 스캔한 후 길이 확대 프로그램을 이용하였다. 각 와동을 37% 인산으로 산부식한 다음 단일병 접착제 Single $Bond^{TM}$ (3M/ESPE, USA)를 적용하였고 혼합형 복합레진 Filtek $Z-250^{TM}$ (3M/ESPE, USA)을 사용하여 적층 충전하였다. 치아를 실온에서 증류수에 24시간 동안 보관한 다음 Sof-Lex system (3M/ESPE, USA)을 사용하여 연마하였다. 이후 자가중합형 레진에 교합면을 기저부에 평행한 상태로 치근부를 매몰한 다음 Universal testing machine (Zwick Z010, Germany)에서 지름 3 mm의 staineless steel rod를 1 mm/min의 cross-head speed로 하중을 가하여 파절 강도를 측정하였다. 통계 분석은 95% 유의 수준의 One-way ANOVA와 Tukey test를 이용하였으며 다음과 같은 결과를 얻었다. 1. 와동 형성 후 복합레진을 수복한 군들은 대조군에 비해 약 75%의 파절 강도를 보였다. 2. 교합면쪽 잔존 치질의 두께에 따른 파절 저항은 유의한 차이를 보이지 않았다 (p > 0.05). 복합레진을 이용하여 첨와 형태의 와동을 수복한 후 파절 강도를 측정한 결과 건전 치아보다는 강도가 낮았지만, 상부의 잔존 치질이 대부분 법랑질로 이루어진 경우에도 복합 레진으로 수복하면 건전 치아 파절 강도의 75%까지 유지할 수 있다는 결론을 얻었다.

  • PDF