• Title/Summary/Keyword: Tooth Surface

Search Result 876, Processing Time 0.029 seconds

AN EXPERIMFNENTAL STUDY ON THE SURFACE ROUGHNESS OF ACID ETCHING ENAMEL SURFACE IN HUMAN TEETH (산부식처리(酸腐蝕處理) 치아법랑질(齒牙琺瑯質) 표면(表面)의 조도(粗度)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Lee, Eun-Goo
    • Restorative Dentistry and Endodontics
    • /
    • v.5 no.1
    • /
    • pp.13-18
    • /
    • 1979
  • The purpose of this study was to measure the roughness on the acid -etching surface. The etching agents of three-kinds composite resins were used to etch the tooth surface. Newly extracted I5-anterior teeth were invested with self-curing acrylic resin, and the labial surface was exposed. The exposed labial side was polished with abrasive papers and finally polished on polishing machine with zinc oxide powder. After the teeth were polished, the specimens were washed by water and dried by air. Surface roughness tester, Taylor-Habson's Taly Surf-10, (Fig-1) was used to measure roughness of this unetched tooth surface. And that, the specimens were divided into three groups. The first group was etched with Restodent etchant, the second group was etched with Nuva-system etchant, and Hi-pol etching agent was used in the third group. And the surface roughness tester was used to measure roughness of the etching teeth surface. The results obtained were as follows. 1. The roughness of acid-etched enamel were increased $2{\mu}m$ to $6{\mu}m$. 2. Hi-pol etchant produced the smoothest surface($2.3{\mu}m$). 3. Restodent etchant($3.8{\mu}m$) and Nuva-system etchant($3.7{\mu}m$) produced rougher surface than Hi-pol.

  • PDF

Kinematical Investigation and Geometry Modeling of the Perfect Involute Bevel Gearsets (완전한 인볼류트 베벨기어쌍의 기구학적 고찰 및 형상 모형화)

  • Park, N.G.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.5
    • /
    • pp.46-56
    • /
    • 1995
  • As demands on the precision bevel gears are increased in the related industry, the exact kinematical investigations of a pair of spherical involute bevel gears are required for the computer aided design. The exact angular velocity ratio based on the characteristics of the spherical involute tooth is derived and verified from the relationship between rotational angles. Elementary kinematics of the gearsets is investigated by applying the transformation of the coordinate systems. The tooth contact lines based on logarithmic tooth-wise curve are examines in three dimentional space. Contact ratio is formulated and simulated according to the system parameters such as shaft angles, pressure angle, and spiral angles. The condition of teeth interference is dervied and the critical numbers of gear teeth are calculated. The whole surface geometry of a spiral bevel gearsets are discretized and visualized by a computer graphic tool.

  • PDF

Optimization of the Gear Tooth Crowning Amount Considering Contact Subsurface Stress (표면아래응력을 고려한 기어이의 크라우닝 최적화에 관한 연구)

  • Lee, Sang-Don;Kim, Jong-Sung;Cho, Yong-Joo
    • Tribology and Lubricants
    • /
    • v.25 no.1
    • /
    • pp.38-42
    • /
    • 2009
  • Gear is an essential component of an automotive. Crowning is used for tooth modification of a gear. The basic concept of gear tooth crowning is to reduce the stress concentration in edge of contact area and appropriate profile modifications can help gears to resist scoring, pitting, and tooth breakage. In this study, a method to determinate spur gear tooth crowning amount to make smooth surface stress and subsurface stress distribution is proposed. This method is based on the contact analysis.

A STUDY ON THE INFLUENCE OF PRETREATMENT ON THE BOND STRENGTHS OF SOME PIT AND FISSURE SEALANTS (수종의 치면열구 전색재의 전처리가 결합강도에 미치는 영향)

  • Min, Yun-Kyung;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.277-284
    • /
    • 1998
  • For the purpose of comparing the shear bond strengths of pit and fissure sealants, and finding out the more efficient method of tooth surface treatment when the etched surface is contaminaed by saliva or moisture, an experiment was performed on 3 types of pit and fissure sealants. 120 extracted human molars were divided into 3 groups, each of which was composed of 40 specimens sealed with Helioseal, Teethmate-F and Fuji III respectively. And each groups was again divided into 4 subgroups according to tooth surface treatment. The shear bond strengths of each groups and subgroup was measured and statistically analyzed. The results obtained were as follows : 1. Shear bond strengths of nonfluoridated resin sealant, Helioseal were shown to be higher than those of fluoridated resin sealant, Teethmate-F, but, not significantly different. 2. Shear bond strengths of GI sealant, Fuji III were to be markedly lower than those of two resin sealants. 3. When there is moisture contamination, applying primer under sealant(Group IV) results in a significantly stronger bond strength of sealant to enamel than when using sealant alone(Group II) in case of all sealants. 4. When there is no moisture contamination, using primer under sealant (Group III) results in bond strength equivalent to bond strength on using sealant alone (Group I). 5. Based on the results above, it was demonstrated that the bond of sealant to tooth surface is greatly affected by saliva contamination and that the complete tooth isolation method should be fully emphasized. The application of primer is recommended when performing sealant under the environment very susceptible to saliva contamination.

  • PDF

Shear bond strength of a layered zirconia and porcelain according to treatment of zirconia liner (치과용 지르코니아 이장재 처리에 따른 지르코니아와 도재의 전단결합강도 비교)

  • Seo, Jeong Il;Park, Won Uk;Kim, Yang Geun
    • Journal of Technologic Dentistry
    • /
    • v.39 no.1
    • /
    • pp.43-52
    • /
    • 2017
  • Purpose: Physical and chemical properties of gold is most suitable to be restored of teeth to its original state. Recently zirconia was used instead of gold because of esthetical and intimacy of human body. Because of high strength and high abrasion resistance of zirconia, all zirconia artificial tooth lead to wear the original tooth of opposite site. To preserve this original tooth, zirconia artificial tooth covered with dental ceramic glass was used. When joining the zirconia core and dental ceramic glass, difference of their thermal expansion coefficient and wetting ability is generated the residual stress at interface lead to crack. In order to solve this problem, intermediate layer what is called zir-liner was imported to decrease the residual stress and increase the bonding strength. Methods: In this study, to identify the optimum conditions for manufacturing process, various methods to rough the surface of zirconia core were adopted, and vary the thickness of interlayer, and analyzed bond strength. Results: Bond strength of sanding specimens group showed higher than that of non-sanding specimens group, and once applied intermediate layer with sanding specimens showed highest bond strength with 28 MPa. SEM photomicrographs of zirconia cores fired at $1500^{\circ}C$ showed parallel straight lines in sanding and pockmarked surface in blasting surfaces as abrasion traces. Observation of the destruction section after shear test by SEM were carried out. Liner applied non-sanding group and non-liner applied sanding group all showed interfacial crack. Sandblasting group with non-liner showed remained dental ceramic glass on the surface of zirconia. Sandblasting group with once applied liner showed partially remained liner and dental ceramic glass on the surface of zirconia. XRD analysis revealed that sandblasting group showed higher monoclinic peaks than other specimens group and this result was due to the high collision energy for stress induced phase transformation. Conclusions: A study on the improvement of bonding strength between zirconia and dental ceramic glass steadily carried out for the future to practical use.

A Comparison of effectiveness of Gracey curet and Mini-five curet on subgingival scaling and root planing (치은연하 치석제거와 치근면 활택술시 Gracey curet과 Mini-five curet의 치석제거 효과에 대한 비교 연구)

  • Jang, Won-Hyeuck;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.3
    • /
    • pp.585-595
    • /
    • 1997
  • Removal of subgingival calculus is essential for the success in periodontal treatment. Subgingival instrumentation is used for the removal of all bacterial plaque and calculus. In this study, two types of anterior curet were used on ant. teeth to conduct subgingival scaling and root planing. The remaining amount of calculus was evaluated according to type of instrument, depth of pocket, and tooth surface. 24 teeth extracted from patients being treated at Dan Kook University dept. Perio. were used. 4 surfaces per tooth a total of 96 areas were evaluated. 12 teeth treated with Gracey No. 1-2 was used as the control group and 12 teeth treated with Mini-five curet No. 1-2 was the experimental group. The 4 surfaces of the teeth {buccal, mesial, lingual or palatal, distal) were observed under a stereomicroscope and the images were captured 3 times per surfaced with a CCD. The image were observed on the monitor using a $10{\times]10$ grid produced with the Microsoft power point. The amount of calculus remaining was evaluated 3 times per surface. The results were as follows. 1. There was no significant difference in remaining calculus according to the pre-treatment pocket depth, and tooth position{Mx. or Mn). 2. The Mini-five curet showed better results than the Gracey curet but there was no statistically significant difference. 3. In both Gracey curet group and Mini-five curet group the lingual(or palatal) surface showed significant difference compared to the other surfaces(p<0.05). From the results above, it is thought that when treating ant. teeth consideration of the tooth surface is more important than the choice of instrument.

  • PDF

AN EXPERIMENTAL STUDY ON ADHESION PATTERN, ADHESION STRENGTH AND FRACTURE PATTERN OF THE ADHESIVE CAST GOLD INLAY (접착형 구조 금 인레이의 접착 형태, 강도 및 파절 양태에 관한 실험적 연구)

  • Han, Seoung-Ryul;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.64-72
    • /
    • 1994
  • Zinc Phosphate Cement hand been used for about more than 100 years in luting of cast gold inlay. But many scientists had been trying to develop the new form of luting agent because the ZPC hand shown the lack of adhesiveness on the tooth structure and the toxicity to the pulp tissue. Recently many researches about the surface treatment of the cast body are being done to increase the adhesion of cement to it. The conventional Class I gold inlays were fabricated in the 20 permanent molars. After the internal surface of the cast body was sandblasted with $Al_2O_3$ particles and was tin-plated, the inlays were cemented with adhesive cement [G I cement and resin cement(Super-Bond & $Panavia_{EX}$)] and the evaluation on the adhesion pattern, adhesive strength and the fracture pattern of the adhesive cast gold inlay was compared to that of the cast gold inlay cemented conventionally with ZPC. The results were as follows : 1. The surface roughness of the cast body was increased significantly after sandblasting with the $Al_2O_3$ particles and the tin oxide layer, which was consisted of round particles, came into being. 2. The bond strength was in the order of Super-Bond, ZPC, Fuji I, $Panavia_{EX}$ group. The group cemented with Super-Bond showed statistically greater strength than the other groups(p<0.05). 3. The group cemented with ZPC was fallen apart by principal adhesion failure and that with Fuji I was by complete adhesion failure. But the group with Super-Bond showed pricncipal cohesive failure pattern and in the group with $Panavia_{EX}$, complete cohesive fracture pattern was shown and small protion of tooth structure was fractured out with cast body and the fractured surface showed the figure just as the enamel prism. 4. Various gaps were shown at the pulpal side regardless of little gap at the side walls of the cavity in all groups. Only the Super-Bond was attached to the tooth structure and the other cements were detached from both the tooth and the cast body.

  • PDF

Influence of thickness and incisal extension of indirect veneers on the biomechanical behavior of maxillary canine teeth

  • Costa, Victoria Luswarghi Souza;Tribst, Joao Paulo Mendes;Uemura, Eduardo Shigueyuki;de Morais, Dayana Campanelli;Borges, Alexandre Luiz Souto
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.4
    • /
    • pp.48.1-48.13
    • /
    • 2018
  • Objectives: To analyze the influence of thickness and incisal extension of indirect veneers on the stress and strain generated in maxillary canine teeth. Materials and Methods: A 3-dimensional maxillary canine model was validated with an in vitro strain gauge and exported to computer-assisted engineering software. Materials were considered homogeneous, isotropic, and elastic. Each canine tooth was then subjected to a 0.3 and 0.8 mm reduction on the facial surface, in preparations with and without incisal covering, and restored with a lithium disilicate veneer. A 50 N load was applied at $45^{\circ}$ to the long axis of the tooth, on the incisal third of the palatal surface of the crown. Results: The results showed a mean of $218.16{\mu}strain$ of stress in the in vitro experiment, and $210.63{\mu}strain$ in finite element analysis (FEA). The stress concentration on prepared teeth was higher at the palatal root surface, with a mean value of 11.02 MPa and varying less than 3% between the preparation designs. The veneers concentrated higher stresses at the incisal third of the facial surface, with a mean of 3.88 MPa and a 40% increase in less-thick veneers. The incisal cover generated a new stress concentration area, with values over 48.18 MPa. Conclusions: The mathematical model for a maxillary canine tooth was validated using FEA. The thickness (0.3 or 0.8 mm) and the incisal covering showed no difference for the tooth structure. However, the incisal covering was harmful for the veneer, of which the greatest thickness was beneficial.

Accuracy evaluation of dental model scanner according to occlusal attrition type (교합면의 교모형태에 따른 치과용 모형 스캐너의 정확도 평가)

  • Kim, Dong-Yeon;Kim, Ji-Hwan;Lee, Beom-Il;Lee, Ju-Hee;Kim, Won-Soo;Park, Jin-Young
    • Journal of Technologic Dentistry
    • /
    • v.42 no.4
    • /
    • pp.313-320
    • /
    • 2020
  • Purpose: The purpose of this study is to compare and analyze the accuracy of single crowns based on the type of occlusal surface. Methods: A single crown wax pattern was fabricated in three types of occlusal surface. The prepared wax pattern was replicated with silicone, and stone was injected to create a stone model. The prepared specimens were scanned using a model scanner. Scans were classified into three groups, and each scan was performed six times to analyze the trueness and precision of a single crown. In addition, only the occlusal surface area was analyzed for trueness and precision. Data were analyzed using the Kruskal-Wallis H test, a nonparametric test (α=0.05). Results: With regard to the trueness value of the occlusal scan area, the no occlusal tooth attrition (NA) group showed the largest error of 3.5 ㎛, and the complete occlusal tooth attrition (CA) group showed the lowest value of 3.1 ㎛. The NA group had the greatest precision, and the medium occlusal tooth attrition (MA) group and CA group showed a low precision value of 3.2 ㎛; the difference between the groups was statistically significant (α=0.05). In the color difference map, the CA group showed a lower error than the NA group. Conclusion: The occlusal surface with severe attrition had excellent accuracy, but the accuracy of the group without attrition was low. There were significant differences between groups, but clinically acceptable values were shown.

The Influence of Home Position(H.P.) and Random Position(R.P.) on the Shape of Prepared Tooth Surfaces -Upper Left 1st Molar for Full Cast Crown- (시술자세가 치관 삭제면 형태에 미치는 영향 -상악 좌측 제 1 대구치의 전부 주조관-)

  • Lee, Seung-Jeong;Choi, Dae-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.4
    • /
    • pp.257-274
    • /
    • 2001
  • To properly prepare teeth, dentists require a direct view of the working area and are often placed in a difficult position, moreover, a high proportion of dentists suffer from headache and back pain. Dentists who make use of the dental mirror and position their patients carefully to gain a proper view report less headache, pain and discomfort in the shoulders. It is recommended that dentists learn the "Home Position(H.P.)" which among the various "Random Position(R.P.)" methods, enables dentists to approach their patients in a stable posture. The purpose of this study was to compare tooth preparation in the H.P. and the R.P., and evaluate the clinical efficacy of the H.P.. Tooth preparation for a full cast crown was performed on the maxillary left 1st molar using the H.P. and the R.P., and the shapes of the prepared tooth surfaces at the two different operating positions were compared. The amount of occlusal reduction, marginal width, height, and axial taper were measured and analyzed. A T-test was performed separately to compare the results of the H.P. and the R.P. with respect to the accuracy of the corresponding tooth reduction. The results were as follows. ; 1. The amount of occlusal reduction was excessive on the mesiobuccal cusp(P<0.05), and deficient on the lingual cusp in the H.P.(P<0.01). In the R.P., this was excessive on the buccal cusp and deficient on the fossa and distolingual cusp(P<0.01). 2. The amounts of marginal width were excessive in all areas except on the lingual and mesial surfaces in the H.P. and lingual surface in the R.P.(P<0.01). 3. The marginal heights were achieved more accurately in the R.P. than the H.P.(P<0.01). 4. Axial surface taper was excessive in all areas in the H.P.(P<0.01). But the axial taper of measured areas was even, and tooth is more like to retain its original axis after reduction. In the R.P., axial surface taper was excessive on the mesial and buccal area, and deficient on the distolingual area(P<0.01), and therefore, the axis of the prepared teeth was tipped in the distolingual direction. 5. The times needed for preparation were 12 minutes and 49 seconds in the H.P., and 11 minutes and 35 seconds in the R.P., and the R.P. was statistically faster(P<0.01). The tooth preparation in the H.P. achieved its goal, in that it enabled the operator to make even tooth reduction. In conclusion, the H.P. system offers an improved method that can be used in clinic after specific training.

  • PDF