• Title/Summary/Keyword: Tooth Shape

Search Result 343, Processing Time 0.022 seconds

A Study on the tooth size and shape of the permanent Incisor teeth (영구치 절치의 크기와 형태에 관한 연구)

  • Lee, Tae-Jung;Shin, Jong-Woo
    • Journal of Technologic Dentistry
    • /
    • v.15 no.1
    • /
    • pp.89-94
    • /
    • 1993
  • The tooth size and shape of the permanent incisor teeth have been studied and analyzed about the mean size, S.D, S.E, etcs and percentage from stone model of 100 Korean male and 74 Korean female. The results were as follows. 1. The crown length of permanent incisor teeth were longer in males than in females statistical differences of males and female were not found. 2. the mesio-distal diameters of permanent incisor teeth were larger in males than in females and statistical differences of males and females were found in mandibular lateral incisor and the bigest were max. central incisor, 2nd max. lateral incisor, 3rd man. lateral incisor and the smallest were man. central incisor. 3. The square form in max. central incisor was the greatest percentage and the tapering form in max. lateral incisor and man, incisor was the greatest percentage but tapering form and ovoid form and other shape were found in max. lateral at the same ratio. 4. Concerning the labial developmental groove "midium" was the greatest percentage in the max. central incisor and "low" was the greatest percentage in the man incisor. Concerning the incisal line, straight line was the greatest percentage in the max, incisor and man, incisor and concerning the lingual tubercle "none" was the greatest percentage in the max. incisor. 5. In comparison between left side and right side of incisor, the ratio of same shape ware 22.4%-36.2% but similar or dissimilar cases were more frequently found.

  • PDF

Development of Hot and Cold Combined Forging Process for a One-Way Clutch Bearing Outer Race (원웨이 클러치 베어링 외륜의 열간과 냉간 복합단조 공정 기술 개발)

  • Jang, S.J.;Jun, B.Y.;Jang, S.M.;Joun, M.S.;Moon, H.K.;Sung, H.S.;Heo, M.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.441-444
    • /
    • 2009
  • In this research, a hot and cold combined forging process for manufacturing net-shape one-way clutch bearing outer race of an automobile automatic transmission unit is developed. The process is composed of hot forging for manufacturing an optimized gear-like perform and precision cold forging for sizing the perform into final net-shape product. Finite element simulation techniques are applied to find the optimized process designs including blank and die shapes. The predictions and experiments are compared, revealing that they are in good agreement with each other. The dimensional test showed that the important dimensional requirements on gear tooth-like shape of the forged product were fulfilled.

  • PDF

A Study on the Remanufacturing for Drive Spur Gear in Planner Miller by Directed Energy Deposition

  • Jin, Chul-Kyu;Kim, Min-Woo;Woo, Jae-Hyeog
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.6_1
    • /
    • pp.941-952
    • /
    • 2022
  • In this study, additive manufacturing technology was applied to restore a planner miller that was unusable due to aging. The drive spur gear of the planner miller was inoperable due to many defects in the teeth. The shape of the defective gear teeth was restored by deposition of the defective teeth using the DED method. However, as the location of the deposition head and the location of the set origin became farther, the deposition shape was different from the modeling shape. Nonetheless, since the modeling of the deposition part was designed to be larger than the tooth shape of the original gear, it was possible to completely restore all gear teeth through post-processing. The arrangement interval of the flow lines of the deposition part was narrower than that of the substrate. The hardness of the substrate was 172 HV, and that of the deposition part was 345 HV, which was twice as high as that of the substrate.

Effect of size and slope angle of tooth-shaped asperity on shear fracturing characteristics (삼각형 돌출부의 크기 및 경사각이 전단파괴 형상 특성에 미치는 영향)

  • Kim, Won-Keun;Choi, Woo-Yong;Park, Jong-Deok;Lee, Seok-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.4
    • /
    • pp.431-442
    • /
    • 2013
  • Most of previous studies have insufficiently investigated the shear behavior and fracturing characteristics, experimentally in respect to the change of size of tooth-shaped surface asperity such as length and slope angle in a broad range. This study investigates the influence of the length and slope angle of a tooth-shaped surface asperity on the fracturing characteristics and the interface shear strength by using direct shear test apparatus. A total of 36 interface direct shear tests were conducted by changing the three types of slope angle of surface asperity, four type of length, and three types of normal stress. The shape of fractured surface after the test was quantified by using a three-dimensional surface roughness measurement apparatus. Through the experimental test results, the characteristics of fractured shape of surface asperity according to the normal stress were investigated. In addition, fractured length and height were quantified at each slope angle of surface asperity under a certain normal stress condition.

Analysis on Ablation of KL-3 Engine Nozzle Throat Using Image Analysis (영상분석을 통한 KL-3 엔진 노즐목 삭마 경향 분석)

  • Kim, Young-Han;Park, Sung-Jin;Ryu, Chul-Sung;Kim, Yong-Wook;Han, Sang-Yeop;Kim, Byung-Hun
    • 한국연소학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.51-55
    • /
    • 2003
  • In this research, authors tried to measure the shape of the nozzle throat of KL-3 engines, which is the main engine of KSR-III rocket, to find the increase of nozzle area caused by the thermal ablation. For the purpose, we invented an image-based method instead of the 3D pointer, which is actually inaccessible to such large scale engines. As a result, our equipment showed satisfactory accuracy and performance. Analysing the results of experiments, we find that the pattern of ablation is determined by the spray pattern and that the process of thermal ablation phenomena can be categorized in three regimes - the first regime that the shape of nozzle throat is maintained and ablation is negligible, the second regime that saw-tooth form is developed and ablation is accelerated, and the third regime that the saw-tooth form is already established and the growth of ablation rate is reduced. Also, we find that the ratio of area increase after 60 seconds combustion is +5.82% and conclude that this figure is acceptable and satisfactory.

  • PDF

THE EFFECT OF CAVITY CONFIGURATION ON MARGINAL LEAKAGE OF CLASS 5 RESTORATION (와동형태가 5급 와동 수복물의 변연누출에 미치는 영향)

  • Park, Jeong-Kil;Hur, Bock;Lee, Hee-Ju
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.2
    • /
    • pp.162-170
    • /
    • 2001
  • The purpose of this study was to investigate the effect of cavity configurations on the marginal leakage of class 5 glass ionomer cement and composite resin restorations. Four types of cavities such as saucer shape. notch shape. combined shape(notch shape occlusally and saucer shape gingivally). and U shape were prepared on the buccal and lingual surfaces of 80 extracted premolars(40 cavities for each shape). Occlusal cavity margins were placed at enamel and cervical margins were placed at dentin. 10 cavities of each shape were restored with Ketac Fil as a conventional glass ionomer cement. Fuji II LC improved as a resin modified glass ionomer cement, Z 100 as a hybrid composite resin. and Tetric Flow as a flowable composite resin (40 cavities for each material). After thermocycling, teeth were immersed in 5% basic fuchsin solution for 6 hours and sectioned longitudinally in a buccolingual direction through the center of the restoration. The dye penetrations at the tooth restoration interface were examined by stereomicroscope. The Result were as follows 1. In saucer shape, notch shape and combined shape, composite resin restorations showed lesser leakage than glass ionomer restorations(p<0.05) and in U shape. Tetric Flow showed the least marginal leakage and others were decreased as Z 100. Fuji II LC improved, Ketac Fil in that order. There were statistically significant difference between Tetric Flow and Fuji II LC improved. Ketac Fil and between Z 100 and Ketac Fil(p<0.05). 2. In Ketac Fil restoration group, saucer shape showed the highest marginal leakage and U shape showed the least marginal leakage and others were decreased as notch shape, combined shape in that order. There were statistically significant difference between saucer shape and combined shape, U shape and between notch shape and U shape(p<0.05). 3. In Fuji II LC improved restoration group, U shape showed the least marginal leakage. There were statistically significant difference between U shape and other three shapes(p<0.05). 4. The cavity configuration had no significant effect on marginal leakage of composite resin restorations(p>0.05).

  • PDF

Three dimensional evaluation of impacted mesiodens using dental cone beam CT (치과용 콘빔 CT를 이용한 상악 정중과잉치의 3차원 분석)

  • Lee, Dong-Ho;Lee, Jea-Seo;Yoon, Suk-Ja;Kang, Byung-Cheol
    • Imaging Science in Dentistry
    • /
    • v.40 no.3
    • /
    • pp.109-114
    • /
    • 2010
  • Purpose : This study was performed to analyze the position, pattern of impacted mesiodens, and their relationship to the adjacent teeth using Dental cone-beam CT. Materials and Methods : Sixty-two dental cone-beam CT images with 81 impacted mesiodenses were selected from about 2,298 cone-beam CT images at Chonnam National University Dental Hospital from June 2006 to March 2009. The position, pattern, shape of impacted mesiodenses and their complications were analyzed in cone-beam CT including 3D images. Results : The sex ratio (M : F) was 2.9 : 1. Most of the mesiodenses (87.7%) were located at palatal side to the incisors. 79% of the mesiodenses were conical in shape. 60.5% of the mesiodenses were inverted, 21% normal erupting direction, and 18.5% transverse direction. The complications due to the presence of mesiodenses were none in 43.5%, diastema in 19.4%, tooth displacement in 17.7%, delayed eruption or impaction in 12.9%, tooth rotation in 4.8%, and dentigerous cyst in 1.7%. Conclusions : Dental cone-beam CT images with 3D provided 3-dimensional perception of mesiodens to the neighboring teeth. This results would be helpful for management of the impacted mesiodens.

Micro-computed tomography for assessing the internal and external voids of bulk-fill composite restorations: A technical report

  • Tosco, Vincenzo;Monterubbianesi, Riccardo;Furlani, Michele;Giuliani, Alessandra;Putignano, Angelo;Orsini, Giovanna
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.303-308
    • /
    • 2022
  • Purpose: This technical report aims to describe and detail the use of micro-computed tomography for a reliable evaluation of the bulk-fill composite/tooth interface. Materials and Methods: Bulk-fill composite restorations in tooth cavities were scanned using micro-computed tomography to obtain qualitatively and quantitatively valuable information. Two-dimensional information was processed using specific algorithms, and ultimately a 3-dimensional (3D) specimen reconstruction was generated. The 3D rendering allowed the visualization of voids inside bulk-fill composite materials and provided quantitative measurements. The 3D analysis software VG Studio MAX was used to perform image analysis and assess gap formation within the tooth-restoration interface. In particular, to evaluate internal adaptation, the Defect Analysis addon module of VG Studio Max was used. Results: The data, obtained with the processing software, highlighted the presence and the shape of gaps in different colours, representing the volume of porosity within a chromatic scale in which each colour quantitatively represents a well-defined volume. Conclusion: Micro-computed tomography makes it possible to obtain several quantitative parameters, providing fundamental information on defect shape and complexity. However, this technique has the limit of not discriminating materials without radiopacity and with low or no filler content, such as dental adhesives, and hence, they are difficult to visualise through software reconstruction.