• Title/Summary/Keyword: Tool insulation

Search Result 67, Processing Time 0.024 seconds

Comparison between Water and N-Tetradecane as Insulation Materials through Modeling and Simulation of Heat Transfer in Packaging Box for Vaccine Shipping

  • Dao, Van-Duong;Jin, Ik-Kyu;Hur, Ho;Choi, Ho-Suk
    • Clean Technology
    • /
    • v.22 no.1
    • /
    • pp.45-52
    • /
    • 2016
  • This study reports on the modeling and simulation of heat transfer in packaging boxes used for vaccine shipping. Both water and n-tetradecane are used as primary insulation materials inside a multi-slab system. The one-dimensional model, which is a spherical model using a radius equivalent to the rectangular geometry of container, is applied in this study. N-tetradecane with low thermal diffusivity and proper phase transition temperature exhibits higher heat transfer resistance during both heating and cooling processes compared to water. Thus, n-tetradecane is a better candidate as an insulating material for packaging containers for vaccine shipping. Furthermore, the developed method can also become a rapid and economic tool for screening appropriate phase change materials used as insulation materials with suitable properties in logistics applications.

Development of a Simplified Test Apparatus for Measuring Sound Transmission Loss (간이 차음시험장치 개발)

  • 이해성;전오성;강현주;김봉기
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.892-897
    • /
    • 2003
  • This study deals with the performance of a simplified test apparatus for measurement of sound insulation of panels. In order to investigate its performance, results from experiment and theory of the sound transmission loss for single and double panels are compared. Comparative results show that in evaluation of the sound insulation performance, the test apparatus has a cumbersome problem at the low frequency region, i.e. below 315 ㎐, presumably because of the poor diffuse sound field in the chambers. Meanwhile at the high frequency, it shows a considerable results comparable to the theoretical prediction. One of the objective of this study that compares measured results between a real reverberation chamber and a simplified test apparatus, by using a specimen of a sandwich panel. It shows qualitatively resonable agreement from which one can find a potential to provide a design tool.

  • PDF

A Study of the evaluation of Building Energy Rating depending on region according to the Insulation Performance of the Super window (슈퍼윈도우 열성능에 따른 지역별 건물에너지 효율등급에 관한 연구)

  • Jang, Cheol-Yong;Ahn, Byung-Lip;Kim, Chi-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.211-215
    • /
    • 2009
  • As entering in the time of high oil price, seriousness of an energy is on the rise and the importance of energy is growing. Especially, building energy occupying 24% of total demand of energy is expected to be possible to reduce energy demand more than other section. To reduce the building energy consumption, this study analyzes function and thermal performance of Super window by heat experimental apparatus. Super window is a 2-track low-e glazing window for high insulation efficiency. By applying the results of this experiment to building energy efficiency rating tool, this study compares energy efficiency rates depending on a region.-Jeju, South, Central. And it shows how much does Super window reduce Building energy consumption.

  • PDF

Development of a Live-line Insulator Inspection Tool System for 154 kV Power Transmission Lines

  • Lee, Jae-Kyung;Park, Joon-Young;Cho, Byung-Hak;Oh, Ki-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.23-33
    • /
    • 2012
  • The current paper deals with a new live-line insulator inspection tool system that will be used by the Korea Electric Power Corporation for its 154 kV power transmission lines in 2011. Unlike the existing contact type tools, the developed inspection tool automates parts of the insulator inspection process using a sensor and an actuator. The tool sustains its weight independently, not by a lineman. In addition, the inspection tool measures the insulation resistance of an insulator together with its distribution voltage, thus providing more information for analysis and diagnosis. Such characteristics improve the system's operation efficiency, measurement reliability, and usability. We confirmed its effectiveness through live-line field tests with actual power transmission lines.

Measurement of Gastric Contractility of Awake Rats by Bowel Sounds Recorded through an Electronic Stethoscope in a Sound Insulation Box (차음상자와 전자청진기로 기록된 장음에 의해서 깨어 있는 흰쥐의 위수축력 측정)

  • Yoon, Sang-Hyub
    • The Journal of Internal Korean Medicine
    • /
    • v.35 no.4
    • /
    • pp.439-447
    • /
    • 2014
  • Objectives: The aim of this study was to investigate whether 1) variation of bowel sounds recorded stably through an electronic stethoscope in a sound insulation box can be related with that of gastric contraction and 2) if they are thus useful tool in the measurement of the gastric contractility in awake rats or not. Methods: Electrical potentials of both electronic stethoscope of bowel sound and force transducer were recorded simultaneously and continuously in the sound insulation box for the starting 30 min of basal state, and then 30 min of 0.2 ml normal saline administration, finally 30 min of 0.2 ml mosapride citrate solution (100 mg/Kg) in rats. Each motility index of normal saline or mosapride citrate treatment was presented with ratio against the basal state by using integrated electrical potentials. Results: A pattern of significance of gastric contractility between bowel sound and force transducer was showed analogously. Conclusions: The amplitude of bowel sounds recorded by the electronic stethoscope related with the intensity of gastric contractions. This confirms that a sound insulation box and electronic stethoscope are useful tools in the measurement of the gastric contractility of awake rats.

Evaluation of On-Line Partial Discharge Measurement Techniques on Hydro-Generator (수력 발전기의 운전중 부분방전 측정기법에 대한 신뢰성 평가)

  • Hwang, D.H.;Kim, J.B.;Kim, Y.J.;Park, M.S.;Kim, T.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1526-1529
    • /
    • 1994
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the end winding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current test and ${\Delta}tan{\delta}$ test has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot discharges may not be found with off-line diagnoses. This paper describes the on-line partial discharge measurement techniques in the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF

Three-dimensional Analysis for Three-phase Spacers in Gas Insulated System (3차원 전계해석 기법을 이용한 GIS 삼상 일괄형 스페이서 고찰)

  • Kang, J.S.;Lee, B.W.;Kang, S.M.;Oh, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1620-1622
    • /
    • 2003
  • Recently, as the technology for the development of high voltage power apparatus using SF6 gas has made remarkable progress, it became possible to develop more compact power apparatus adopting single body substation system. In these gas insulated power apparatus, it is impossible to achieve perfect and safe insulation using only SF6 gas, because some solid insulation parts should be installed to support current-carrying conductor parts for electrical and mechanical safety. When spacers were installed in SF6 gas insulation system, they were exposed to severe electrical intensification which could reduce system insulation performance and restrict the rated operating voltage So, it is necessary to clarify the dielectric characteristics of spacers by analytically and experimentally, in order to design and develop more compact and optimum gas insulated systems. In this paper, the field distribution of three-phase spacers were investigated using three dimensional electrostatic field analysis tool adopting BEM method. And the obtained results were compared to the conventional two dimensional computations. According to these three dimensional calculations, it was possible to find out weak points in the spacer more clearly and these results could be applied to design more compact and optimum three phase spacer developments.

  • PDF

The Characteristics of Electric Shock Accidents and Their Countermeasures for Portable Electrical Tools (이동형 전기기기의 감전재해 특성 및 그 대책)

  • Choi, Sang-Won
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.21-26
    • /
    • 2017
  • According to the data of Korea Occupational Safety and Health Agency, electric shock accidents during recent 11 years exceeded more than 60% in architecture/other and construction work, the countermeasures for safety are required in the harsh environment of a construction site where moving electric machines and equipments are widely used. The establishment of countermeasure for insulation degradation and defect is required, in consideration of increasing trend for accidents caused by defective insulation among low voltage electrical installation each year. The aim of this study is to propose the policy about portable electrical tool standards and/or worker's safety standards for preventing electric shock accidents on safety workings, and is to develop the technology and the safety device to prevent electric shock for accident prevention reduction through experiments. It obtained the followings through this study; statistical data analysis of late about 10 years of electric shock-related industrial accidents analysis and portable electric tools; safety device development of 'device for testing continuous grounding and power shut-down' to prevent electric shock from portable electric tools. Furthermore, developed results and proposal in this study will help to prevent the electric shock accidents from portable electric tools and will be expected the utilization of policy formulation, educational data and field supplement of the safety device, and etc.

Energy Saving by Combination of Element Technologies of Zero-Energy House (제로에너지 주택용 요소기술 조합에 따른 에너지절감에 관한 연구)

  • Shin, Hyun-Cheol;Jang, Gun-Eik
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.77-84
    • /
    • 2015
  • Purpose: In 2008, As the green growth policy was presented, Green Building is made any effort to propagation. In this paper, the respective technologies that are able to considerably reduce the energy demands for heating, cooling, hot-water, lighting and ventilation among the variety of technologies were selected. Method: Design factors such as (1) External insulation, (2) Triple glazing window, (3) LED lighting, (4) External venetian blind, (5) Geothermal and (6) Heat recovery ventilator were derived. In addition, energy saving effects in terms of energy demand, energy consumption and energy cost were investigated using EnergyPlus, building energy analysis tool. Result : The results were as follows. (1) It can be seen that high insulated triple glazing window, heat recovery ventilator and external insulation technology is excellent for energy demand. (2) Unlike energy demand, saving effect of energy consumption and energy cost was shown in order of Geothermal > Triple Window > Heat recovery Ventilation> Insulation> LED Lighting > EVB Blind.

A Study on the Insulation Performance of the Super window considering the evaluation of Building Energy Rating (지역별 건물에너지 효율에 관한 슈퍼윈도우 단열 성능 평가 연구)

  • Jang, Cheol-Yong;Ahn, Byung-Lip;Kim, Chi-Hoon;Hong, Won-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.39-44
    • /
    • 2009
  • Entering in the time of high oil price, seriousness of an energy effect sector has given a huge impact and the importance of energy is growing. Especially, building energy occupying 24% of total demand of energy is expected to be possible to reduce energy demand more than other section. To reduce the building energy consumption, this study analyzes function and thermal performance of Super window by heat experimental apparatus. Super window is a 2-track low-e glazing window for high insulation efficiency. By applying the results of this experiment to building energy efficience rating tool, this study compares energy efficiency rates depending on a region.-Jeju, South, Central. And it shows how much does Super window reduce Building energy consumption.