• 제목/요약/키워드: Tool Calibration

검색결과 349건 처리시간 0.031초

병렬기구형 CNC 공작기계의 개발 (Development of a Parallel-Typed CNC Machine)

  • 이민기;최병오;김태성;박근우
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.535-540
    • /
    • 2000
  • This paper presents the development of a Parallel-Typed CNC Machining Tool. It is specially designed to machine a complex shaped workpiece by controlling the orientation of the tool. The inverse/direct kinematics of a parallel mechanism is derived and implemented in a PC based controller. With graphics icons, the GUI (Graphic User Interface) program is developed for the CNC programing. The calibration is accomplished by geometric constraint motion, which is a parallel motion of the platform with respect to a table. The calibration result is introduced and the future study is proposed.

  • PDF

Development of a Vision-based Position Estimation System for the Inspection and Maintenance Manipulator of Steam Generator Tubes a in Nuclear Power Plant

  • Jeong, Kyung-Min;Cho, Jae-Wan;Kim, Seung-Ho;Kim, Seung-Ho;Jung, Seung-Ho;Shin, Ho-Chul;Choi, Chang-Whan;Seo, Yong-Chil
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.772-777
    • /
    • 2003
  • A vision-based tool position estimation system for the inspection and maintenance manipulator working inside the steam generator bowl of nuclear power plants can help human operators ensure that the inspection probe or plug are inserted to the targeted tube. Some previous research proposed a simplified tube position verification system that counts the tubes passed through during the motion and displays only the position of the tool. In this paper, by using a general camera calibration approach, tool orientation is also estimated. In order to reduce the computation time and avoid the parameter bias problem in an ellipse fitting, a small number of edge points are collected around the large section of the ellipse boundary. Experiment results show that the camera calibration parameters, detected ellipses, and estimated tool position are appropriate.

  • PDF

자동 선삭 셀에 적합한 인프로세스 측정/ 검사 시스템 (In-process calibration system suitable for unattended turning cells)

  • 김선호;김선호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.804-808
    • /
    • 1991
  • In a transfer line with mass production capability, calibration systems are included in the process as a separate dedicated station. However, this method is not appropriate in an unattended FMC with flexibility. As the FMC produces vesatile parts with small batch sizes, more flexible calibration systems are required. In this paper, a calibration/inspection system suitable for an unattended turning cell is introduced. The system has functions of dimension calibration of parts by touch probes, tool wear compensation, and quality monitoring of parts. Furthermore, characteristics of errors in the system are identified and corresponding compensation methodology is suggested. An operation software was developed for efficient use of the system.

  • PDF

엔드밀 가공시 주축 오리엔테이션 기능을 통한 공구마멸측정 보정 장치의 개발 (Development of Calibration Instrument far Tool Wear Measurement using Spindle Orientation Function in End Milling)

  • 강익수;김전하;강명창;김정석;김기태
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.149-153
    • /
    • 2003
  • The most important thing in measuring the tool wear is to set up the measurement base. The end mill that is being used for machining is difficult to set up the base and to measure the tool wear because of geometric properties of that such as a helix and relief angle. In this study, a new instrument using spindle orientation function in end milling is developed to measure tool wear and evaluated by measuring system on the machine. Finally, this new method makes possible the wear measurement of same position and reduces measuring time compared with measuring methods such as the microscope and CCD.

  • PDF

여유구동 병렬기구의 기구학적 보정 (Kinematic Calibration Method for Redundantly Actuated Parallel Mechanisms)

  • 정재일;김종원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.355-360
    • /
    • 2002
  • To calibrate a non-redundantly actuated parallel mechanism, one can find actual kinematic parameters by means of geometrical constraint of the mechanism's kinematic structure and measurement values. However, the calibration algorithm for a non-redundant case does not apply fur a redundantly actuated parallel mechanism, because the angle error of the actuating joint varies with position and the geometrical constraint fails to be consistent. Such change of joint angle error comes from constraint torque variation with each kinematic pose (meaning position and orientation). To calibrate a redundant parallel mechanism, one therefore has to consider constraint torque equilibrium and the relationship of constraint torque to torsional deflection, in addition to geometric constraint. In this paper, we develop the calibration algorithm fir a redundantly actuated parallel mechanism using these three relationships, and formulate cost functions for an optimization algorithm. As a case study, we executed the calibration of a 2-DOF parallel mechanism using the developed algorithm. Coordinate values of tool plate were measured using a laser ball bar and the actual kinematic parameters were identified with a new cost function of the optimization algorithm. Experimental results showed that the accuracy of the tool plate improved by 82% after kinematic calibration in a redundant actuation case.

  • PDF

인터벤션에서 Calibration Mode에 대한 오차율 비교 (Comparison on the Error Rates of Calibration Modes in Intervention)

  • 공창기;류영환
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.619-626
    • /
    • 2020
  • 이 연구의 목적은 경피적 혈관내 풍선 확장술이나 스텐트 삽입술에서 Balloon이나 Stent의 직경 및 길이를 예측 할 때 사용되는 정량적인 평가 도구인 Calibration Mode중 Catheter Calibration Mode, Auto Calibration Mode 그리고 Segment Calibration Mode에서의 오차율에 대해 알아보고자 하였다. Calibration의 정량적인 평가를 위해 정교하게 제작된 직경 × 길이(2 mm × 80 mm) Copper Wire와 5, 10, 15, 30, 40 mm의 Metal Ball을 이용하여 실험하였고, 아크릴 팬텀은 25 mm, 50 mm, 75mm, 100 mm, 125 mm, 150mm, 175 mm, 200 mm로 하여 각각의 높이에서 혈관조영 촬영장치로 Subtraction 영상을 획득하여 장비 회사에서 제공하는 소프트웨어인 Stenosis Analysis Tools을 이용하여 측정하였다. Catheter Calibration Mode에서의 오차율을 평가하기 위한 방법으로 Copper Wire를 각각의 아크릴 팬텀위에 올려놓고 촬영하였으며, Copper Wire 직경 2 mm를 Catheter의 직경으로 Setting하였고, 길이 8 mm Copper Wire의 길이를 Multi-segments로 측정하여 분석한 결과 1.13 ~ 5.63%의 오차율이 나타났다. Auto Calibration Mode에서의 오차율을 평가하기 위한 방법으로 각각의 아크릴 팬텀을 높이에서 아크릴 높이에 대한 수치를 입력하고, 8 mm Copper Wire의 길이를 Multi-segments 측정하여 분석한 결과 0 ~ 0.26%의 오차율이 나타났다. Segment Calibration Mode에서의 오차율을 평가하기 위한 방법으로 테이블 바닥에 있는 각각의 Metal Ball을 각각 Calibration하고, 각각의 아크릴 팬텀 위에 올려 있는 8 mm Copper Wire의 길이를 측정하여 아크릴 팬텀 높이 변화에 대한 8 mm Copper Wire 길이를 Mutli-segments 측정하여 분석한 결과 1.05 ~ 19.04%의 오차율이 나타났다. 그리고 Auto Calibration Mode에서 OID 변화에 대한 실험은 아크릴 팬텀의 높이는 100mm로 고정하고 OID만 450 mm ~ 600 mm로 변화를 하였을때 오차율은 0.13 ~ 0.38%로 나타났다. 결론적으로 소프트웨어에서 제공하는 정량적인 혈관의 치수평가를 하기 위한 이들 Calibration Mode 중 Auto Calibration Mode에서 높이 값을 입력하는 것이 오차율이 가장 적은 Calibration 방법임을 확인하였으며, Metal ball이나 기타 다른 물체를 이용하여 Calibration을 하기 위해서는 시술부위와 동등한 높이에 놓고 Calibration을 하는 방법이 오차율을 가장 줄일 수 있는 방법으로 사료된다.

소자 시뮬레이션을 이용한 Circuit Model Parameter 생성에 대한 연구 (The Study of Circuit Model Parameter Generation Using Device Simulation)

  • 이흥주
    • 한국산학기술학회논문지
    • /
    • 제4권3호
    • /
    • pp.177-182
    • /
    • 2003
  • Flash memory는 device 특성상 peripheral circuit을 구성하는 transistor의 종류가 다양하고, 이에 따른 각 transistor의 동작 전압 영역이 넓다. 이에 따라 설계 초기의 전기적 특성 사양 결정을 위해서는, 실리콘상에서 소자의 scale down에 따른 전기적 특성을 선 검증하는 과정이 필수적이었으며, 이로 인해 설계 및 소자 개발의 기간을 단축하기 어려웠다. 본 연구에서는 TCAD tool을 사용하여 실리콘상에서의 제작 공정을 거치지 않고, 효과적으로 model parameter를 생성할 수 있도록 하는 방법을 제안하여 전기적 특성 사양 결정과 설계 단계의 시간 지연을 감소할 수 있도록 한다. 또한 성공적 TCAD tool적용을 위해 필요한 process/device simulator의 calibration methodology와 이를 flash 메모리 소자에 대해 적용 검증한 결과를 분석한다.

  • PDF

도로 위 숫자 및 기호 인식을 위한 광각렌즈 기반 Camera Calibration 연구

  • 강진규;홍형길;;;박강령;조형오
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2015년도 추계학술발표대회
    • /
    • pp.1406-1407
    • /
    • 2015
  • 본 논문에서는 도로 위 숫자 및 기호인식에 적합한 Calibration Model에 대하여 연구하였다. 기존에 제시된 Geometric Transform, Fisheye Projection, Caltech Toolbox 기반 방법으로 얻은 Calibration Model의 성능을 비교하였다. Geometric Transform은 Fisheye Distortion Correction에 부적합한 결과를 얻었고, Fisheye Projection은 성능은 좋으나 시스템에 사용할 Camera Lens의 Specification을 모르기 때문에 이를 예측해야 하는 단점이 있다. 마지막으로 Caltech Tool box 기반 방법은 Calibration을 위한 Keypoint를 수동으로 지정하다 보니까 이로 인한 오차가 존재하게 된다. Calibration을 시도 할 때마다 결과에 차이가 있었으며, Calibration 결과의 측면에서 Fisheye Projection이 가시적으로 가장 좋은 결과를 나타냈다.

접촉식 프로브의 오차교정 및 보정기술 (Calibration/Compensation of Errors of the Touch Probe)

  • 박희재;이교일
    • 대한기계학회논문집
    • /
    • 제18권8호
    • /
    • pp.2081-2087
    • /
    • 1994
  • Touch trigger probes are widely used for inspection purposed in the CMM(Coordinate meauring machine) or machine tool. The errors introduced by measurement probe are fairy systematic, thus can be calibrated and compensated properly. This paper presents a technique for the error calibration and compensation of the probe errors, which can be easily applicable to the manufacturers and users of the measurement probe. The probe coordinate system is defined for the probe error assessment, and a reference sphere ball is measured, and the probe errors are calibrated. The calibrated probe errors are represented in the 3D error map and 2D error map along probing direction. Detail algorithms for the error compensation are proposed.

병렬기구형 공작기계의 보정 시스템 개발 (Development of Kinematic Calibration System for a Parallel-typed Machining Center Tool)

  • 김태성;박근우;윤태성;이민기
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.521-526
    • /
    • 2001
  • This research develops a low-cost and high accurate kinematic calibration method for a parallel typed machining center tool. A planar table is used for a mechanical fixture restricting the platform to place at the constrained pose and a low-cost and high accurate digital indicator is employed for a device checking if the constrained movement is satisfied within the established range. The kinematic parameters calibrated with respect to a single plane aren't influenced from the misalignment of the plane. A parameter observability is successfully obtained even through one planar constraint, which guarantees that the kinematic parameters is estimated by minimizing the cost function.

  • PDF