• Title/Summary/Keyword: Tomography, computed

Search Result 5,324, Processing Time 0.026 seconds

Evaluation of the Treatment Response after Hypofractionated Radiotherapy in Patients with Advanced Head and Neck Cancers (진행성 두경부 상피세포암 환자에서 소분할 방사선조사 후의 치료반응 평가)

  • Kim, Won-Taek;Ki, Yong-Kan;Nam, Ji-Ho;Kim, Dong-Hyun;Cho, Kyu-Sup;Lee, Jin-Choon;Lee, Byung-Joo;Kim, Dong-Won
    • Radiation Oncology Journal
    • /
    • v.27 no.2
    • /
    • pp.55-63
    • /
    • 2009
  • Purpose: This study was performed to objectively evaluate the rate of tumor response to hypofractionated radiotherapy for advanced squamous cell carcinomas of the head and neck. Materials and Methods: Thirty-one patients with advanced squamous cell carcinoma of the head and neck, who were treated by hypofractionated radiotherapy with 3 Gy per fraction for palliative purpose between 1998 and 2008, were reviewed retrospectively. Every tumor-volume was measured and evaluated from CT (computed tomography) images obtained before and 2~3 months after radiotherapy. The radiation toxicity was assessed during and after radiotherapy. A statistical analysis was performed to investigate overall survival, progressionfree survival, and the prognostic factors for survival and response. Results: The median age of the study patients was 70 years. In addition, 85% of the patients were in stage 4 cancer and 66.7% had an ECOG performance status of 1~2. The mean tumor-volume was 128.4 cc. Radiotherapy was administered with a total dose of 24~45 Gy (median: 36 Gy) over 10~25 days. Twenty-nine patients were treated with 30 Gy or more. The observed complete response rate was 12.9% and the partial response rate was 61.3%. Median survival time was 8.9 months and the 1-year progression-free survival rate was 12.9%. The treatment response rate was confirmed as a prognostic factor in the rate of survival. The primary site, stage, tumor-volume, radiotherapy field and overall radiation-dose showed a significant relationship with survival and treatment response. No grade 4 toxicity was observed during and after radiotherapy. Conclusion: There was an objective tumor-regression in about 74% of patients treated by hypofractionated radiotherapy. Further evaluation is needed to select the appropriate fraction-size and patient who may require the additional radiotherapy.

The Clinical Outcomes of Off-Pump Coronary Artery Bypass Grafting in the Octogenarians (80세 이상 고령 환자에서 심폐바이패스 없이 시행한 관상동맥우회술의 중단기 성적)

  • Kim Do-Kyun;Lee Chang Young;Lee Kyo Joon;Joo Hyun Chul;Yoo Kyung-Jong
    • Journal of Chest Surgery
    • /
    • v.38 no.10 s.255
    • /
    • pp.680-684
    • /
    • 2005
  • Background: With the increasing age of the population, coronary artery bypass grafting in the elderly patients is becoming common. Off-pump coronary artery bypass grafting (OPCAB) has been proven to be less morbidity and to facilitate early recovery. The elderly patients may have benefits by avoiding the adverse effects of the cardiopulmonary bypass. The purpose of this study is to evaluate our results of OPCAB in elderly patients. Material and Method: A retrospective chart review was carried out for 12 patients aged over 80 years who underwent isolated OPCAB from January 2001 and March 2004. Data were collected risk factors for disease, extent of coronary disease, and in-hospital outcomes. Postoperative graft patiency was evaluated in 9 patients by multi-slice computed tomography. Result: Eleven patients had triple vessel disease or left main disease. Four patients were suffered from preoperative CVA, and 4 patients had chronic obstructive pulmonary disease. Two patients had myocardial infarction (MI), among them 1 patient was suffered from pulmonary edema after preoperative MI. There was no perioperative death, perioperative MI, and no ventricular arrhythmia. Also there was no perioperative stroke and renal failure. But there was one deep sternal infection who recovered by treating of muscle flap. Atrial fibrillation was newly developed in 1 patient, but was well controlled by medication. Mean intubation time was $15.9\pm4.4(8\~20hrs)$ hrs and mean ICU stay was $2.9\pm0.8(2\~4 days)$ days. Mean hospital day was $21.6\pm14.3(13\~56 days)$ days. Postoperative mean CK-MS was $11.3\pm14.1\;ng/mL$. Early postoperative graft patency rate was $100\%(24/24)$. Follow-up was completed in all patients. In this time, there was no patients with angina or death. Conclusion: The results of this study suggest that OPCAB reduces morbidity and favors hospital outcomes. Therefore, OPCAB is safe, reasonable and might be preferable operative strategy in elderly patients.

Clinical Analysis of the Surgical Treatments for Large Primary Spontaneous Pneumothorax (외과적 치료를 시행한 대량 일차성 자연기흉의 임상분석)

  • Kim, Byung-Ho;Huh, Dong-Myung;Han, Won-Kyung
    • Journal of Chest Surgery
    • /
    • v.42 no.3
    • /
    • pp.344-349
    • /
    • 2009
  • Background: The clinical history and physical findings of the patients with spontaneous pneumothorax depend largely on the extent of the collapse of the lung and the presence of pre-existing pulmonary disease. Large primary spontaneous pneumothorax is a possible serious condition and. so more active treatment will be necessary for these patients. The therapeutic guideline for large pneumothorax remains controversial. Therefore, by assessing the clinical results of surgical treatment for large primary pneumothorax, we aim to determine the indicators of treatment. Material and Method: Among 348 patients with primary spontaneous pneumothorax and who underwent surgical treatment from August 2004 through December 2007, 58 patients who responded to treatment for a large primary pneumothorax were included in the current study. We then retrospectively evaluated the operative findings and the surgical results. The patients with a pneumothorax of 80% or more, including those patients with tension pneumothorax, were considered to have a "large pneumothorax". Most of these patients Should be treated with a 12F chest tube. Thoracoscopic wedge resection was considered for treating recurrent pneumothorax, continuous air leakage, controlateral pneumothorax and first episode pneumothorax with visible blebs (> 1cm) seen on the computed tomography. Result: There were 50 men and 8 women with a mean age of 28.2 years (range: $14\sim54$ years). The mean length of hospitalization was 5.3 days (range: $2\sim10$ days). Nine patients underwent chest tube drainage only. Forty-nine patients underwent thoracoscopic wedge resection. The mean follow up time was 27.8 months (range: $10\sim58$ months). The actual site of air leakage could be located in 35 patients (71.4%) and this was correlated with pleural adhesion (p=0.005). The initial air leakage tended to be more correlated with intra-operative air leakage, although this was not statistically significant (p=0.066). The recurrence rate was 11.1 % for the patients with chest tube drainage and 2.0% for the patients with thoracoscopic wedge resection. Conclusion: Large primary pneumothorax requires an early diagnosis and early treatment. Thoracoscopic wedge resection may help to prevent recurrence of large primary pneumothorax.

Assessment of Viability in Regional Myocardium with Reversed Redistribution by Thallium Reinjection in Patients with Acute Myocardial Infarction (급성심근경색 환자에서 역재분포를 보인 심근의 Thallium 재주사에 의한 생존능의 평가)

  • Yoon, Seok-Nam;Park, Chan-H.;Pai, Moon-Sun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.509-515
    • /
    • 1998
  • Purpose: The aim of this study was to evaluate whether T1-201 reinjection distinguishes viable from non-viable myocardium in patients with reverse redistribution after acute myocardial infarction. Materials and Methods: We studied 42 patients with acute myocardial infarction (age, $55{\pm}12$ years). Eighteen (43%) out of 42 showed reverse redistribution on dipyridamole stress-4 hour redistribution T1-201 single photon emission computed tomography (SPECT). T1-201 reinjection was performed at 24 hours. Reverse redistribution was defined as worsening of perfusion defect at 4 hour delayed scan. All patients underwent follow-up echocardiography in 4 months to assess regional wall motion improvement. T1-201 uptake on reinjection images were analyzed for the prediction of myocardial wall motion improvement. Results: Of 36 segments with reverse redistribution, 17 segments showed normal wall motion on echocardiography, while 19 segments showed wall motion abnormalities. Of 19 the segments with reverse redistribution, 11 (58%) showed enhanced uptake after 24 hour reinjection. Myocardial wall motion was improved in 10 of 11 segments (90%) with enhanced uptake on reinjection. Wall motion improvement was not seen in 5 of 8 segments (63%) without enhanced thallium uptake. When myocardial viability was assessed by the uptake on reinjection image, nine of 10 segments (90%) with normal or mildly decreased uptake showed improved wall motion. Wall motion was not improved in 5 of 9 segments (16%) with severely decreased uptake. Conclusion: In patients with acute myocardial infarction, T1-201 reinjection imaging on myocardial segments with reverse redistribution has a high positive predictive value in the assessment of myocardial viability.

  • PDF

Tc-99m MAG3 SPECT on Transplanted Kidney (이식 신장에서 시행한 Tc-99m MAG3 SPECT)

  • Ryu, Jong-Gul;Kim, Soon;Zeon, Seok-Kil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.6
    • /
    • pp.519-526
    • /
    • 1999
  • Purpose: This study was designed to evaluate the usefulness of a technetium-99m mercaptoacetyltriglycine (Tc-99m MAG3) single photon emission computed tomography (SPECT) performed on transplanted kidney. Materials and Methods: Thirty renal transplant patients were included in this study. Planar scan was performed for 30 minutes using 555 MBq Tc-99m MAG3. A post-voiding SPECT scan was acquired on the third, seventh, fourteenth and twenty eighth day after transplantation. Results: SPECT scan showed interpretable image quality in 26 of 30 patients (86.7%) and 84 in 120 scans (70%). Fourteen of 26 patients with interpretable SPECT image showed decreased or increased radioactivity, but only 5 had abnormal findings on the planar scan. Focal SPECT defects were seen in allografts with normal function (n=3), acute tubular necrosis (n=3), and acute rejection (n=2). The defects are thought to reflect focally underperfused renal parenchyme or, in normal allografts, an artifact from uneven radioactivity distribution. Four of 10 patients with renal arterial variation showed focally decreased radioactivity and SPECT helped guide funker studies that confirmed the exact cause. Five of 10 patients with acute tubular necrosis or acute rejection showed focally decreased radioactivity, but its relation to the patients' clinical course was not clear. Focally increased radioactivity was observed in 5 allografts with normal function and 1 with double ureter in which local clearance delay was observed. Conclusion: Tc-99m MAG3 SPECT renal scan can detect additional focal abnormalities compared to planar scan. Further study is necessary to elucidate the exact clinical significance of the SPECT findings.

  • PDF

Effective Dose Determination From CT Head & Neck Region (두경부(Head & Neck) CT 검사 시 장기의 유효선량 측정)

  • Yun, Jae-Hyeok;Lee, Kwang-Weon;Cho, Young-Ki;Choi, Ji-Won;Lee, Joon-Il
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.105-116
    • /
    • 2011
  • In this study, we present the measurements of effective dose from CT of head & neck region. A series of dose measurements in anthropomorphic Rando phantom was conducted using a radio photoluminescent glass rod dosimeter to evaluate effective doses of organs of head and neck region from the patient. The experiments were performed with respect to four anatomic regions of head & neck: optic nerve, pons, cerebellum, and thyroid gland. The head & neck CT protocol was used in the single scan (Brain, 3D Facial, Temporal, Brain Angiography and 3D Cervical Spine) and the multiple scan (Brain+Brain Angiography, Brain+3D Facial, Brain+Temporal, Brain+3D Cervical spine, Brain+3D Facial+Temporal, Brain+3D Cervical Spine+Brain Angiography). The largest effective dose was measured at optic nerve in Brain CT and Brain Angiography. The largest effective dose was delivered to the thyroid grand in 3D faical CT and 3D cervical spine, and to the pons in Temporal CT. In multiple scans, the higher effective dose was measured in the thyroid grand in Brain+3D Facial, Brain+3D Cervical Spine, Brain+3D Facial+Temporal and Brain+3D Cervical Spine+Brain Angiography. In addition, the largest effective dose was delivered to the cerebellum in Brain CT+Brain Angiography CT and higher effective dose was delivered to the pons in Brain+Temporal CT. The results indicate that in multiple scan of Brain+3D Cervical Spine+Brain Angiography, effective dose was 2.52 mSv. This is significantly higher dose than the limitation of annual effective dose of 1 mSv. The effective dose to the optic nerve was 0.31 mSv in Brain CT, which shows a possibility of surpassing the limitation of 1 mSv by furthre examination. Therefore, special efforts should be made in clinical practice to reduce dose to the patients.

Treatment Planning for Minimizing Carotid Artery Dose in the Radiotherapy of Early Glottic Cancer (조기 성문암의 방사선치료에서 경동맥을 보호하기 위한 치료 계획)

  • Ki, Yang-Kan;Kim, Won-Taek;Nam, Ji- Ho;Kim, Dong-Hyun;Lee, Ju-Hye;Park, Dal;Kim, Don-Won
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.115-120
    • /
    • 2011
  • Purpose: To examine the feasibility of the treatment planning for minimizing carotid artery dose in the radiotherapy of early glottic cancer. Materials and Methods: From 2007 to 2010, computed tomography simulation images of 31 patients treated by radiotherapy for early glottic cancer were analyzed. The virtual planning was used to compare the parallel-opposing fields (POF) with the modified oblique fields (MOF) placed at angles to exclude the ipsilateral carotid arteries. Planning target volume (PTV), irradiated volume, carotid artery, and spinal cord were analyzed at a mean dose, $V_{35}$, $V_{40}$, $V_{50}$ and with a percent dose-volume. Results: The beam angles were arranged 25 degrees anteriorly in 23 patients and 30 degrees anteriorly in 8 dose-volume of carotid artery shows the significant difference (p<0.001). The mean doses of carotid artery were 38.5 Gy for POF and 26.3 Gy for MOF and the difference was statistically significant (p=0.012). Similarly, $V_{35}$, $V_{40}$, and $V_{50}$ also showed significant differences between POF and MOF. Conclusion: The modified oblique field was respected to prevent a carotid artery stenosis and reduce the incidence of a stroke based on these results.

Reduction Aortoplasty with Suture Plication Technique for Dilatation of the Ascending Aorta associated with Aortic Valve Disease (대동맥판막 질환과 동반된 상행대동맥 확장에 대한 봉합봉축법에 의한 대동맥 축소성형술)

  • Na Chan-Young;Oh Sam-Sae;Lee Chang-Ha;Whang Seong Wook;Lee Cheol;Lim Hong Gook;Kim Jae Hyun;Seo Hong Ju;Kim Gun Gyk;Baek Man-Jong
    • Journal of Chest Surgery
    • /
    • v.38 no.3 s.248
    • /
    • pp.221-228
    • /
    • 2005
  • Reduction aortoplasty has been advocated for dilatation of the ascending aorta associated with aortic valve disease in older, high-risk patients. We report our results with modification of reduction aortoplasty and aortic valve replacement. Material and Method: Between July 2001 and December 2002, 14 consecutive patients who underwent modification of reduction aortoplasty, suture plication technique without excision of the dilated aortic wall, were reviewed. The mean age was 63.7$\pm$6.7 (50 to 75) years. Ten patients had congenital bicuspid aortic valve, Twelve patients had severe aortic valve stenosis and 6 had regurgitation of grade III$\~$IV. The diameter of the ascending aorta was measured before and immediately after surgery and 6 and 12 months postoperatively using echocardiography or computed tomography. Follow-up was complete in an average of 14.7$\~$5.4 (7 to 24) months. Result: There were no early postoperative deaths and no bleeding complications. Reduction aortoplasty with suture plication technique decreased the diameter of ascending aorta from 49.4$\pm$3.5 mm preoperatively to 33.2$\pm$3.4 mm postoperatively (p <0.001). During follow-up, there were no late deaths and no aneurysm recurrence on the ascending aorta. Conclusion: Suture plication technique of reduction aortoplasty without excision of the dilated aortic wall offers good early and short-term results in older, high-risk patients with dilatation of the ascending aorta associated with aortic valve disease. Surgical long-term results of our technique should be evaluated in further studies.

Research of z-axis geometric dose efficiency in multi-detector computed tomography (MDCT 장치의 z-축 기하학적 선량효율에 관한 연구)

  • Kim, You-Hyun;Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.167-175
    • /
    • 2006
  • With the recent prevalence of helical CT and multi-slice CT, which deliver higher radiation dose than conventional CT due to overbeaming effect in X-ray exposure and interpolation technique in image reconstruction. Although multi-detector and helical CT scanner provide a variety of opportunities for patient dose reduction, the potential risk for high radiation levels in CT examination can't be overemphasized in spite of acquiring more diagnostic information. So much more concerns is necessary about dose characteristics of CT scanner, especially dose efficient design as well as dose modulation software, because dose efficiency built into the scanner's design is probably the most important aspect of successful low dose clinical performance. This study was conducted to evaluate z-axis geometric dose efficiency in single detector CT and each level multi-detector CT, as well as to compare z-axis dose efficiency with change of technical scan parameters such as focal spot size of tube, beam collimation, detector combination, scan mode, pitch size, slice width and interval. The results obtained were as follows ; 1. SDCT was most highest and 4 MDCT was most lowest in z-axis geometric dose efficiency among SDCT, 4, 8, 16, 64 slice MDCT made by GE manufacture. 2. Small focal spot was 0.67-13.62% higher than large focal spot in z-axis geometric dose efficiency at MDCT. 3. Large beam collimation was 3.13-51.52% higher than small beam collimation in z-axis geometric dose efficiency at MDCT. 4. Z-axis geometric dose efficiency was same at 4 slice MDCT in all condition and 8 slice MDCT of large beam collimation with change of detector combination, but was changed irregularly at 8 slice MDCT of small beam collimation and 16 slice MDCT in all condition with change of detector combination. 5. There was no significant difference for z-axis geometric dose efficiency between conventional scan and helical scan, and with change of pitch factor, as well as change of slice width or interval for image reconstruction. As a conclusion, for reduction of patient radiation dose delivered from CT examination we are particularly concerned with dose efficiency of equipment and have to select proper scanning parameters which increase z-axis geometric dose efficiency within the range of preserving optimum clinical information in MDCT examination.

  • PDF

Quantitative Study of Annular Single-Crystal Brain SPECT (원형단일결정을 이용한 SPECT의 정량화 연구)

  • 김희중;김한명;소수길;봉정균;이종두
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.163-173
    • /
    • 1998
  • Nuclear medicine emission computed tomography(ECT) can be very useful to diagnose early stage of neuronal diseases and to measure theraputic results objectively, if we can quantitate energy metabolism, blood flow, biochemical processes, or dopamine receptor and transporter using ECT. However, physical factors including attenuation, scatter, partial volume effect, noise, and reconstruction algorithm make it very difficult to quantitate independent of type of SPECT. In this study, we quantitated the effects of attenuation and scatter using brain SPECT and three-dimensional brain phantom with and without applying their correction methods. Dual energy window method was applied for scatter correction. The photopeak energy window and scatter energy window were set to 140ke${\pm}$10% and 119ke${\pm}$6% and 100% of scatter window data were subtracted from the photopeak window prior to reconstruction. The projection data were reconstructed using Butterworth filter with cutoff frequency of 0.95cycles/cm and order of 10. Attenuation correction was done by Chang's method with attenuation coefficients of 0.12/cm and 0.15/cm for the reconstruction data without scatter correction and with scatter correction, respectively. For quantitation, regions of interest (ROIs) were drawn on the three slices selected at the level of the basal ganglia. Without scatter correction, the ratios of ROI average values between basal ganglia and background with attenuation correction and without attenuation correction were 2.2 and 2.1, respectively. However, the ratios between basal ganglia and background were very similar for with and without attenuation correction. With scatter correction, the ratios of ROI average values between basal ganglia and background with attenuation correction and without attenuation correction were 2.69 and 2.64, respectively. These results indicate that the attenuation correction is necessary for the quantitation. When true ratios between basal ganglia and background were 6.58, 4.68, 1.86, the measured ratios with scatter and attenuation correction were 76%, 80%, 82% of their true ratios, respectively. The approximate 20% underestimation could be partially due to the effect of partial volume and reconstruction algorithm which we have not investigated in this study, and partially due to imperfect scatter and attenuation correction methods that we have applied in consideration of clinical applications.

  • PDF