• Title/Summary/Keyword: Tomography, computed

Search Result 5,212, Processing Time 0.018 seconds

The Study on the Independent Predictive Factor of Restenosis after Percutaneous Coronary Intervention used Drug-Eluting Stent : Case on MDCT Calcium-Scoring Implementation Patient (약물용출 스텐트를 이용한 관상동맥중재술 후 재협착의 독립적 예측인자에 관한 연구 : MDCT calcium-scoring 시행 환자 대상으로)

  • Kim, In-Soo;Han, Jae-Bok;Jang, Seong-Joo;Jang, Young-Ill
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.37-44
    • /
    • 2010
  • We sought to confirm an independent factor about in-stent restenosis (ISR) in the patients who underwent drug-eluting stent (DES) and know a possibility as a predictor of measured coronary artery calcium score by MDCT. A total of 178 patients (159 men, $61.7{\pm}10.0$ years of age) with 190 coronary artery lesions were included in this study out of 1,131 patients who underwent percutaneous coronary intervention (PCI) with DES implantation for significant stenosis on MDCT at Chonnam National University Hospital between May 2006 and May 2009. All lesions were divided into two groups with the presence of ISR : group I (re ISR, N = 57) and group II (no ISR, N = 133). Compared to group II, group I was more likely to be older ($65.8{\pm}9.0$ vs. $60.2{\pm}9.9$ years, p = 0.0001), diabetic (21.8% vs. 52.6%, p = 0.0001), have old myocardial infarction (8.8% vs. 2.3%, p = 0.040), left main stem disease (5.3% vs. 0.8%, p = 0.047), and smaller stent size ($3.1{\pm}0.3\;mm$ vs. $3.3{\pm}0.4\;mm$, p = 0.004). Group II was more likely to be smokers (19.3% vs. 42.1%, p = 0.003), have dyslipidemia (8.8% vs. 23.3%, p = 0.019). Left ventricular ejection fraction, lesion complexity, and stent length were not different between the two groups. Total CAC score was $389.3{\pm}458.3$ in group I and $371.2{\pm}500.8$ in group II (p = 0.185). No statistical difference was observed between the groups in CAC score in the culprit vessel, left main stem, left anterior descending artery, left circumflex artery, and right coronary artery. On multivariate logistic regression analysis, left main stem disease (OR = 168.0, 95% CI = 7.83-3,604.3, p = 0.001), male sex (OR = 36.5, 95% CI = 5.89-2,226.9, p = 0.0001), and the presence of diabetes (OR = 2.62, 95% CI = 1.071-6.450, p = 0.035) were independent predictors of ISR after DES implantation. In patients who underwent DES implantation for significant coronary stenosis on MDCT, ISR was associated with left main stem disease, male sex, and the presence of diabetes. However, CAC score by MDCT was not a predictor of ISR in this study population.

A Study on the Availability of the On-Board Imager(OBI) and Cone-Beam CT(CBCT) in the Verification of Patient Set-up (온보드 영상장치(On-Board Imager) 및 콘빔CT(CBCT)를 이용한 환자 자세 검증의 유용성에 대한 연구)

  • Bak, Jino;Park, Sung-Ho;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.118-125
    • /
    • 2008
  • Purpose: On-line image guided radiation therapy(on-line IGRT) and(kV X-ray images or cone beam CT images) were obtained by an on-board imager(OBI) and cone beam CT(CBCT), respectively. The images were then compared with simulated images to evaluate the patient's setup and correct for deviations. The setup deviations between the simulated images(kV or CBCT images), were computed from 2D/2D match or 3D/3D match programs, respectively. We then investigated the correctness of the calculated deviations. Materials and Methods: After the simulation and treatment planning for the RANDO phantom, the phantom was positioned on the treatment table. The phantom setup process was performed with side wall lasers which standardized treatment setup of the phantom with the simulated images, after the establishment of tolerance limits for laser line thickness. After a known translation or rotation angle was applied to the phantom, the kV X-ray images and CBCT images were obtained. Next, 2D/2D match and 3D/3D match with simulation CT images were taken. Lastly, the results were analyzed for accuracy of positional correction. Results: In the case of the 2D/2D match using kV X-ray and simulation images, a setup correction within $0.06^{\circ}$ for rotation only, 1.8 mm for translation only, and 2.1 mm and $0.3^{\circ}$ for both rotation and translation, respectively, was possible. As for the 3D/3D match using CBCT images, a correction within $0.03^{\circ}$ for rotation only, 0.16 mm for translation only, and 1.5 mm for translation and $0.0^{\circ}$ for rotation, respectively, was possible. Conclusion: The use of OBI or CBCT for the on-line IGRT provides the ability to exactly reproduce the simulated images in the setup of a patient in the treatment room. The fast detection and correction of a patient's positional error is possible in two dimensions via kV X-ray images from OBI and in three dimensions via CBCT with a higher accuracy. Consequently, the on-line IGRT represents a promising and reliable treatment procedure.

Clinical Significance of Reverse Redistribution on Tc-99m MIBI and T1-201 Myocardial Perfusion SPECT Images (Tc-99m MIBI와 T1-201 심근 SPECT에서 역재분포의 임상적 의의)

  • Song, Ho-Cheon;Bom, Hee-Seung;Kim, Ji-Yeul;Jeong, Myung-Ho;Gill, Kwang-Chae;Park, Joo-Hyung;Cho, Jeong-Gwan;Park, Jong-Choon;Kang, Jung-Chaee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.95-103
    • /
    • 1996
  • Reverse redistribution(RRD) refers to a perfusion defect that develops or becomes more evident on rest imaging compared with the stress imaging. This phenomenon was not uncommonly noted on myocardial perfusion single photon emission computed tomography (SPECT). However, the clinical significance and pathophysiological mechanism of RRD were unclear. The aim of this study was to evaluate the incidence and clinical significance of RRD on either dipyridamole T1-201 or Tc-99m MIBI myocardial perfusion SPECT. RRD was defined as ${\geq}10%$ decrease in relative T1-201 and Tc-99m MIBI uptakes on rest images compared to the stress images or as an appearance of new perfusion defects on rest images. It was observed in both T1-201 (44/463, 9.5%) and Tc-99m MIBI (124/999, 12.4%) myocardial SPECTs similarly, with an overall incidence of 11.5%(168/1462). Many apparent)y unrelated disease groups showed the finding: post-revascularization(53.9%), coronary artery disease(24.6%), myocardial infarction(12.3%), and those with normal coro-nary arteries (9.2%). Clinical and angiographic characteristics of 65 consecutive patients who underwent coronary arteriography in 168 patients who had RRD on myocardial perfusion SPECT were reviewed. Tc-99m MIBI was used in 44 patients, and T1-201 was used in 21 patients. Of the 81 myocardial segments analyzed which showed RRD, 32 segments(39.5%) were in septum, 24(29.5%) in inferior wallL, 12(14.8%) in anterior wall, 7(8.7%) in apex and 6(7.4%) in lateral wall. There was no clear association between RRD and coronary arterial stenosis or Presence of collateral circulations. Ventriculographical wall motion was evaluated in 27 regions with RRD; it was normal in 12 regions, hypokinetic in 12 regions and dyskinetic in 3 regions. In 14 of 21 patients who showed RRD on T1-201 myocardial SPECT, T1-201 reinjection was performed immediately after the 3-4 hour redistribution studies. Ten of 14 (71.4%) showed enhanced T1-201 activity(${\geq}10%$ increased) after reinjection. We conclude that RRD is not related to mode of stress or radiopharmaceuticals. RRD might represent many inhomogeneous pathophysiological processes.

  • PDF

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF

The Efficacy of the Change in Belly Board Aperture Location by the Addition of Bladder Compression Device for Radiotherapy of Rectal Cancer (직장암 환자의 골반 방사선치료에서 벨리보드 하위 경계 위치 변화의 영향)

  • Yoon, Hong-In;Chung, Yoon-Sun;Kim, Joo-Ho;Park, Hyo-Kuk;Lee, Sang-Kyu;Kim, Young-Suk;Choi, Yun-Seon;Kim, Mi-Sun;Lee, Ha-Yoon;Chang, Jee-Suk;Cha, Hye-Jung;Seong, Jin-Sil;Keum, Ki-Chang;Koom, Woong-Sub
    • Radiation Oncology Journal
    • /
    • v.28 no.4
    • /
    • pp.231-237
    • /
    • 2010
  • Purpose: We investigated the effect of location changes in the inferior border of the belly board (BB) aperture by adding a bladder compression device (BCD). Materials and Methods: We respectively reviewed data from 10 rectal cancer patients with a median age 64 years (range, 45~75) and who underwent computed tomography (CT) simulation with the use of BB to receive pelvic radiotherapy between May and September 2010. A CT simulation was again performed with the addition of BCD since small bowel (SB) within the irradiated volume limited boost irradiation of 5.4 Gy using the cone down technique after 45 Gy. The addition of BCD made the inferior border of BB move from symphysis pubis to the lumbosacral junction (LSJ). Results: Following the addition of BCD, the irradiated volumes of SB and the abdominopelvic cavity (APC) significantly decreased ($174.3{\pm}89.5mL$ vs. $373.3{\pm}145.0mL$, p=0.001, $1282.6{\pm}218.7mL$ vs. $1,571.9{\pm}158mL$, p<0.001, respectively). Bladder volume within the treated volume increased with BCD ($222.9{\pm}117.9mL$ vs. $153.7{\pm}95.5mL$, p<0.001). The ratio of irradiated bladder volume to APC volume with BCD ($33.5{\pm}14.7%$) increased considerably compared to patients without a BCD ($27.5{\pm}13.1%$) (p<0.001), and the ratio of irradiated SB to APC volume decreased significantly with BCD ($13.9{\pm}7.6%$ vs. $24.2{\pm}10.2%$, p<0.001). The ratios of the irradiated SB volume and irradiated bladder volume to APC volume negatively correlated (p=0.001). Conclusion: This study demonstrated that the addition of BCD, which made the inferior border of BB move up to the LSJ, increased the ratio of the bladder to APC volume and as a result, decreased the irradiated volume of SB.

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.

Clinical Differential Diagnosis of Usual Interstitial Pneumonia from Nonspecific Interstitial Pneumonia (통상성 간질성 폐렴과 비특이성 간질성 폐렴의 임상적 감별 진단)

  • An, Chang-Hyeok;Koh, Young-Min;Chung, Man-Pyo;Suh, Gee-Young;Kang, Soo-Jung;Kang, Kyeong-Woo;Ahn, Jong-Woon;Lim, Si-Young;Kim, Ho-Joong;Han, Jeung-Ho;Lee, Kyung-Soo;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.6
    • /
    • pp.932-943
    • /
    • 2000
  • Background : Nonspecific interstitial pneumonitis (NSIP) is most likely to be confused with usual interstitial pneumonitis (UIP). Unlike patients witþ UIP, the majority of patients with NSIP have a good prognosis, with most patients improving after treatment with corticosteroids. Therefore it is clinically important to differentiate NSIP from UIP. Up to now, the only means of differentiating these two diseases was by means of surgical lung biopsy. American Thoracic Society (ATS) proposed a clinical diagnostic criteria for UIP to provide assistance to clinicians in its diagnosis without surgical lung biopsy. This study is aimed to investigate whether there were clinical and radiological differences between NSIP and UIP, and the usefulness of ATS clinical diagnostic criteria for UIP in Korea. Methods : We studied 60 patients with UIP and NSIP confirmed by surgical lung biopsy. Clinical manifestations, pulmonary function test, arterial blood gas analysis, bronchoalveolar lavage (BAL), and high resolution computed tomography (HRCT) were evaluated and analyzed by Chi-square test or t-test. The clinical criteria for UIP proposed by ATS were applied to all patients with idiopathic interstitial pneumonia. Results : Forty-two patients with UIP and 18 with NSIP were pathologically identified. Among the 18 patients with NSIP (M : F=1 : 17), the mean age was 55.2$\pm$8.4 (44~73) yr. Among the 42 patients with UIP (M : F=33 : 9), the mean age was 59.5$\pm$7.1 (45~74) yr (p=0.046). Fever was more frequent in NSIP (39%) (p=0.034), but clubbing was frequently observed in UIP (33%) (p=0.023). BAL lymphocytosis was more frequent (23%) (p=0.0001) and CD4/CD8 ratio was lower in NSIP (p=0.045). On HRCT, UIP frequently showed honeycomb appearance (36 of 42 patients) though not in NSIP (p=0.0001). Six of 42 UIP patients (14.3%) met the ATS clinical criteria for IPF, and 3 of 16 NSIP patients (18.8%) met the diagnostic criteria. Conclusion : Being a relatively young female and having short duration of illness, fever, BAL lymphocytosis, low CD4/CD8 ratio with the absence of clubbing and honeycomb appearance in HRCT increase the likelihood of the illness being NSIP. The usefulness of ATS clinical diagnostic criteria for UIP may be low in Korea.

  • PDF

Correlation between High-Resolution CT and Pulmonary Function Tests in Patients with Emphysema (폐기종환자에서 고해상도 CT와 폐기능검사와의 상관관계)

  • Ahn, Joong-Hyun;Park, Jeong-Mee;Ko, Seung-Hyeon;Yoon, Jong-Goo;Kwon, Soon-Seug;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Moon, Hwa-Sik;Park, Sung-Hak;Song, Jeong-Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.367-376
    • /
    • 1996
  • Background : The diagnosis of emphysema during life is based on a combination of clinical, functional, and radiographic findings, but this combination is relatively insensitive and nonspecific. The development of rapid, high-resolution third and fourth generation CT scanners has enabled us to resolve pulmonary parenchymal abnormalities with great precision. We compared the chest HRCT findings to the pulmonary function test and arterial blood gas analysis in pulmonary emphysema patients to test the ability of HRCT to quantify the degree of pulmonary emphysema. Methods : From october 1994 to october 1995, the study group consisted of 20 subjects in whom HRCT of the thorax and pulmonary function studies had been obtained at St. Mary's hospital. The analysis was from scans at preselected anatomic levels and incorporated both lungs. On each HRCT slice the lung parenchyma was assessed for two aspects of emphysema: severity and extent. The five levels were graded and scored separately for the left and right lung giving a total of 10 lung fields. A combination of severity and extent gave the degree of emphysema. We compared the HRCT quantitation of emphysema, pulmonary function tests, ABGA, CBC, and patients characteristics(age, sex, height, weight, smoking amounts etc.) in 20 patients. Results : 1) There was a significant inverse correlation between HRCT scores for emphysema and percentage predicted values of DLco(r = -0.68, p < 0.05), DLco/VA(r = -0.49, p < 0.05), FEV1(r = -0.53, p < 0.05), and FVC(r = -0.47, p < 0.05). 2) There was a significant correlation between the HRCT scores and percentage predicted values of TLC(r = 0.50, p < 0.05), RV(r = 0.64, p < 0.05). 3) There was a significant inverse correlation between the HRCT scores and PaO2(r = -0.48, p < 0.05) and significant correlation with D(A-a)O2(r = -0.48, p < 0.05) but no significant correlation between the HRCT scores and PaCO2. 4) There was no significant correlation between the HRCT scores and age, sex, height, weight, smoking amounts in patients, hemoglobin, hematocrit, and wbc counts. Conclusion : High-Resolution CT provides a useful method for early detection and quantitating emphysema in life and correlates significantly with pulmonary function tests and arterial blood gas analysis.

  • PDF

The Utility of Immunological Markers and Pulmonary Function Test in the Early Diagnosis of Pulmonary Involvement in the Patients with Rheumatoid Arthritis (류마티스 관절염환자에서 폐침범의 진단에 있어서 면역학적 지표와 폐기능 검사의 유용성)

  • Lee, Dong-Suk;Lee, Chang-Beam;Koh, Hee-Kwan;Moon, Doo-Seop;Lee, Jae-Young;Lee, Kyung-Sang;Yang, Suck-Chul;Yoon, Ho-Joo;Bae, Sang-Cheol;Shin, Dong-Ho;Kim, Seong-Yoon;Park, Sung-Soo;Lee, Jung-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.878-887
    • /
    • 1995
  • Background: It is reported that frequency of pulmonary involvement in the patients with rheumatoid arthritis reaches 10 to 50% and pulmonary involvement is a principal cause of death. As immunology and radiology has developed, interest for the early diagnosis of pulmonary involvement is increasing. Method: Among the patients at Hanyang University Hospital from March, 1990 to July, 1995, we compared the 29 patients having pulmonary involvement with the 18 patients controls in clinical and chest high resolution computed tomography(HRCT) findings by immunological markers and findings of pulmonary function test. We sought useful markers for early diagnosis of pulmonary involvement with noninvasive investigations. Results: The ratio of males to females was 14 : 15 in the group of pulmonary involvement, and all of the 18 patients were females in the control group. Smoking history was 31%(9/29) in the former group and none in the latter group. Rheumatoid factor(RF) was positive in 95.5%(28/29) of the pulmonary involvement group and in 100%(18/18) of the control group(p=0.12). Antiperinuclear factor(APF) showed a significant difference: 86.9%(20/23, average value: 2.0) was positive in the pulmonary involvement group and 50%(8/16, average value: 1.1) in the control group(p=0.04). Antinuclear antibody(ANA) was positive in 60.7%(17/28) of the pulmonary involvement group and in 72.2%(13/18) of the control group(p=0.33). Cryoglobulin also showed a significant difference: 72%(18/25) in the pulmonary involvement group was positive and 56.2%(9/16) in the control group was positive(p=0.02). Bony erosion was positive in 61.5%(16/26) of the pulmonary involvement group and in 77.7%(14/18) of the control group(p=0.8). On the pulmonary function test, the average value of alveolar volume corrected diffusion capacity and residual volume in the pulmonary involvement group and in the control group were 1.07mmol/rnin/KPa(predicted value: 64.2%), 1.32L(predicted value: 70%) and 1.44mmol/min/KPa, 3.75L(predicted value: 86.6%), respectively(p=0.003, p=0.004), showing a significant difference. Conclusion: APF or cryoglobulin on the serological test, the measurement of residual volume and alveolar volume corrected diffusion capacity may be used as effective markers in the diagnosis of pulmonary involvement of the patients with rheumatoid arthritis.

  • PDF

Correlation analysis of radiation therapy position and dose factors for left breast cancer (좌측 유방암의 방사선치료 자세와 선량인자의 상관관계 분석)

  • Jeon, Jaewan;Park, Cheolwoo;Hong, Jongsu;Jin, Seongjin;Kang, Junghun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.37-48
    • /
    • 2017
  • Purpose: The most basic conditions of radiation therapy is to prevent unnecessary exposure of normal tissue. The risk factors that are important o evaluate the dose emitted to the lung and heart from radiation therapy for breast cancer. Therefore, comparing the dose factors of a normal tissue according to the radion treatment position and Seeking an effective radiation treatment for breast cancer through the analysis of the correlation relationship. Materials and Methods: Computed tomography was conducted among 30 patients with left breast cancer in supine and prone position. Eclipse Treatment Planning System (Ver.11) was established by computerized treatment planning. Using the DVH compared the incident dose to normal tissue by position. Based on the result, Using the SPSS (ver.18) analyzed the dose in each normal tissue factors and Through the correlation analysis between variables, independent sample test examined the association. Finally The HI, CI value were compared Using the MIRADA RTx (ver. ad 1.6) in the supine, prone position Results: The results of computerized treatment planning of breast cancer in the supine position were V20, $16.5{\pm}2.6%$ and V30, $13.8{\pm}2.2%$ and Mean dose, $779.1{\pm}135.9cGy$ (absolute value). In the prone position it showed in the order $3.1{\pm}2.2%$, $1.8{\pm}1.7%$, $241.4{\pm}138.3cGy$. The prone position showed overall a lower dose. The average radiation dose 537.7 cGy less was exposured. In the case of heart, it showed that V30, $8.1{\pm}2.6%$ and $5.1{\pm}2.5%$, Mean dose, $594.9{\pm}225.3$ and $408{\pm}183.6cGy$ in the order supine, prone position. Results of statistical analysis, Cronbach's Alpha value of reliability analysis index is 0.563. The results of the correlation analysis between variables, position and dose factors of lung is about 0.89 or more, Which means a high correlation. For the heart, on the other hand it is less correlated to V30 (0.488), mean dose (0.418). Finally The results of independent samples t-test, position and dose factors of lung and heart were significantly higher in both the confidence level of 99 %. Conclusion: Radiation therapy is currently being developed state-of-the-art linear accelerator and a variety of treatment plan technology. The basic premise of the development think normal tissue protection around PTV. Of course, if you treat a breast cancer patient is in the prone position it take a lot of time and reproducibility of set-up problems. Nevertheless, As shown in the experiment results it is possible to reduce the dose to enter the lungs and the heart from the prone position. In conclusion, if a sufficient treatment time in the prone position and place correct confirmation will be more effective when the radiation treatment to patient.

  • PDF