• Title/Summary/Keyword: Tomography, X-Ray

Search Result 806, Processing Time 0.023 seconds

Imaging for Multiple Myeloma according to the Recent International Myeloma Working Group Guidelines: Analysis of Image Acquisition Techniques and Response Evaluation in Whole-Body MRI according to MY-RADS (International Myeloma Working Group의 최신 가이드 라인에 따른 다발성 골수종의 영상검사법 및 MY-RADS에 따른 전신 MRI에서의 영상 획득과 반응 평가 소개)

  • A Yeon Son;Hye Won Chung
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.150-169
    • /
    • 2023
  • Multiple myeloma (MM) is a malignant hematologic disease caused by the proliferation of clonal plasma cells in the bone marrow, and its incidence is increasing in Korea. With the development of treatments for MM, the need for early diagnosis and treatment has emerged. In recent years, the International Myeloma Working Group (IMWG) has been constantly revising the laboratory and radiological diagnostic criteria for MM. In addition, as whole-body MRI (WBMR) has been increasing used in the diagnosis and treatment response evaluation of patients with MM, the Myeloma Response Assessment and Diagnosis System (MY-RADS) was created to standardize WBMR image acquisition techniques, image interpretation, and response evaluation methods. Radiologists need to have a detailed knowledge of the features of MM for accurate diagnosis. Thus, in this review article, we describe the imaging method for MM according to the latest IMWG guidelines as well as the image acquisition and response evaluation technique for WBMR according to MY-RADS.

Added Value of Structured Reporting for US of the Pediatric Appendix: Additional CT Examinations and Negative Appendectomy (소아 충수 초음파 검사에서 구조화 판독문의 부가가치: 추가 CT 검사 및 음성 충수절제술의 관점에서)

  • Keonwoo Choi;Ji Young Choi;Hyuk Jung Kim;Hyun Jin Kim;Suk Ki Jang
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.653-662
    • /
    • 2023
  • Purpose This study aimed to determine the incremental value of using a structured report (SR) for US examinations of the pediatric appendix. Materials and Methods Between January 2009 and June 2016, 1150 pediatric patients with suspected appendicitis who underwent US examinations of the appendix were included retrospectively. In November 2012, we developed a five-point scale SR for appendix US examinations. The patients were divided into two groups according to the form of the US report: free-text or SR. The primary clinical outcomes were compared between the two groups, including the rate of CT imaging following US examinations, the negative appendectomy rate (NAR), and the appendiceal perforation rate (PR). Results In total, 550 patients were included in the free-text group and 600 patients in the SR group. The rate of additional CT examinations decreased by 5.3% in the SR group (8.2%, p = 0.003), and the NAR decreased by 8.4% in the SR group (7.8%, p = 0.028). There was no statistical difference in the appendiceal PR (37.6% vs. 48.0%, p = 0.078). Conclusion The use of an SR to evaluate US examinations for suspected pediatric appendicitis results in lower CT use and fewer negative appendectomies without an increase in appendiceal PR.

Evaluation of the Usefulness of Exactrac in Image-guided Radiation Therapy for Head and Neck Cancer (두경부암의 영상유도방사선치료에서 ExacTrac의 유용성 평가)

  • Baek, Min Gyu;Kim, Min Woo;Ha, Se Min;Chae, Jong Pyo;Jo, Guang Sub;Lee, Sang Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.7-15
    • /
    • 2020
  • Purpose: In modern radiotherapy technology, several methods of image guided radiation therapy (IGRT) are used to deliver accurate doses to tumor target locations and normal organs, including CBCT (Cone Beam Computed Tomography) and other devices, ExacTrac System, other than CBCT equipped with linear accelerators. In previous studies comparing the two systems, positional errors were analysed rearwards using Offline-view or evaluated only with a Yaw rotation with the X, Y, and Z axes. In this study, when using CBCT and ExacTrac to perform 6 Degree of the Freedom(DoF) Online IGRT in a treatment center with two equipment, the difference between the set-up calibration values seen in each system, the time taken for patient set-up, and the radiation usefulness of the imaging device is evaluated. Materials and Methods: In order to evaluate the difference between mobile calibrations and exposure radiation dose, the glass dosimetry and Rando Phantom were used for 11 cancer patients with head circumference from March to October 2017 in order to assess the difference between mobile calibrations and the time taken from Set-up to shortly before IGRT. CBCT and ExacTrac System were used for IGRT of all patients. An average of 10 CBCT and ExacTrac images were obtained per patient during the total treatment period, and the difference in 6D Online Automation values between the two systems was calculated within the ROI setting. In this case, the area of interest designation in the image obtained from CBCT was fixed to the same anatomical structure as the image obtained through ExacTrac. The difference in positional values for the six axes (SI, AP, LR; Rotation group: Pitch, Roll, Rtn) between the two systems, the total time taken from patient set-up to just before IGRT, and exposure dose were measured and compared respectively with the RandoPhantom. Results: the set-up error in the phantom and patient was less than 1mm in the translation group and less than 1.5° in the rotation group, and the RMS values of all axes except the Rtn value were less than 1mm and 1°. The time taken to correct the set-up error in each system was an average of 256±47.6sec for IGRT using CBCT and 84±3.5sec for ExacTrac, respectively. Radiation exposure dose by IGRT per treatment was measured at 37 times higher than ExacTrac in CBCT and ExacTrac at 2.468mGy and 0.066mGy at Oral Mucosa among the 7 measurement locations in the head and neck area. Conclusion: Through 6D online automatic positioning between the CBCT and ExacTrac systems, the set-up error was found to be less than 1mm, 1.02°, including the patient's movement (random error), as well as the systematic error of the two systems. This error range is considered to be reasonable when considering that the PTV Margin is 3mm during the head and neck IMRT treatment in the present study. However, considering the changes in target and risk organs due to changes in patient weight during the treatment period, it is considered to be appropriately used in combination with CBCT.

Surgical Treatment of Pulmonary Aspergillosis (III) (폐 국균증의 외과적 치료(제 3보))

  • 정성철;김우식;배윤숙;유환국;정승혁;이정호;김병열
    • Journal of Chest Surgery
    • /
    • v.36 no.7
    • /
    • pp.497-503
    • /
    • 2003
  • Pulmonary aspergillosis usually results from the colonization of the existing lung lesions by chronic pulmonary diseases, such as tuberculosis. Most cases of pulmonary aspergilloma have been treated surgically for many years because it is a potentially life-threatening disease causing massive hemoptysis. Here we reviewed our results from the last 10 years. Material and Method: We reviewed 31 cases surgically treated from Aug. 1992 to Jul. 2002. retrospectively. This investigation is designed to illustrate the peak age incidence, sex ratio, chief complaints, preoperative study, anatomic location of operative site, postoperative pathologic finding and postoperative complications. Result: The peak age Incidence laid in the 3rd and 4th decade of 20 cases (64.5%). The most common complaint was hemoptysis in 27 cases (87.1%). The 31 cases had a history of treatment with anti-tuberculous drugs under impression of pulmonary tuberculosis. The 19 cases (61.3%) showed the so-called “Air-meniscus sign” on the preoperative chest X-ray. In the 31 cases (100%) on the chest computed tomography. as a preoperative diagnostic modality, positivity was shown in 37.9%, 83.3% was shown on the fungus culture of sputum for Aspergillus, serum immunodiffusion test for A. fumigatus, respectively. The anatomical location of aspergilloma was mainly in the upper lobe in 19 cases (61.3%) and the majority of cases were managed by lobectomy. The postoperative pathologic findings showed that 31 cases (100%) were combined with tuberculosis. The postoperative complications include empyema, prolonged air leakage, remained dead space, postoperative bleeding and these numbers of cases is 3 cases (9.7%), 2 cases (6.45%), 2 cases (6.45%), 1 case (3.23%), respectively. one case was died postoperatively due to massive beeding, and asphyxia. Conclusion: Compared with the previous study, there is no significant difference in results. Preoperative chest computed tomography and immunodiffusion test were more commonly available and showed high positivity. Operations often became technically difficult because of pleural space obliteration, indurated hilar structures, and poor expansion of the remaining lung, which were more prominent in the patients with complex aspergillosis. In such cases, medical treatments and interventional procedures like bronchial artery embolization are preferred. However, cavernostomy is also recommanded with few additional morbidity because of its relatively less invassiveness. Early surgical intervention is the recommended management for patients with simple aspergilloma considering the Row surgical mortality and morbidity in recent days.

Lung Biopsy after Localization of Pulmonary Nodules with Hook Wire (Hook Wire를 이용한 폐결절의 위치선정 및 생검)

  • Kim, Jin-Sik;Hwang, Jae-Joon;Lee, Song-Am;Lee, Woo-Surng;Kim, Yo-Han;Kim, Jun-Seok;Chee, Hyun-Keun;Yi, Jeong-Geun
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.681-686
    • /
    • 2010
  • Background: A chest computed-tomography has become more prevalent so that it is more common to detect small sized pulmonary nodules that have not been found in previous simple chest x-ray. If those detected nodules are undersized or located in pulmonary parenchyma, it is difficult to accomplish a biopsy since it is vulnerable to explore them either grossly or digitally. Thus, in our hospital, a thoracoscopic pulmonary wedge resection was performed after locating a lesion by means of hook wire with CT-guided. Material and Method: 31 patients (17 males and 14 female patients) from December in 2006 to June in 2010 became our subjects; their 34 pulmonary nodules were subjected to the thoracoscopic pulmonary wedge resection after locating a lesion by means of hook wire with CT-guided. Also we analyzed a possibility of hook wire dislocation, a frequency of conversion to open thoracotomy, time consumed to operation after location of a lesion, operation time, post operation complication, and histological diagnosis of the lesion. Result: 12 of 34 cases were ground glass lesion, whereas 22 cases of them were solitary pulmonary lesion. The median value of the lesion was 8mm in size (range: 3 to 23 mm), while the median value was 12.5 mm in depth (range: 1 to 34 mm). The median value of time consumed from location of the lesion to anesthetic induction was 86.5 minutes (41~473 minutes); furthermore the mean value of operation time was 103 minutes (25~345 minutes). Intrathoracic wire dislocation was found in one case, but a target lesion was successfully excised. Open thoracotomy was performed in four cases due to pleural adhesion. However, there was no case of conversion to open thoracotomy due to failure to detect a target lesion. In histological diagnosis, metastatic cancer were found in 15 cases, which were the most common, primary lung cancer were in 9 cases, non-specific inflammation were in 3 cases, tuberculosis inflammation were in 2 cases, lymph nodes were in 2 cases, active tuberculosis were in 1 case, atypical adenomatous hyperplasia was in 1 case and normal lung parenchymal finding was in 1 case, respectively. Conclusion: In our hospital, in order to accomplish a precise histological diagnosis of ground-glass lesion and pulmonary nodules in lung parenchyma, location of pulmonary nodules were exactly located with hook wire under chest computed-tomography, which was followed by lung biopsy. We concluded that this was an accurate, minimally invasive and valuable method to minimize the complications and increase of cost of medical service provided.

Evaluation and Comparison of Myocardial Perfusion Defects in Patients with Early Breast Cancer Subjected to Different Radiation Simulation Techniques (조기유방암 환자에서 방사선 모의치료 방법의 차이에 따른 심근관류결손의 비교 평가)

  • Nam, Ji-Ho;Ki, Yong-Kan;Kim, Dong-Won;Kim, Won-Taek
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.26-33
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The aim of this study is to evaluate and compare the incidence and aspects of myocardial perfusion defects in patients who were subjected to either two-dimensional or three-dimensional simulation techniques for early left-sided breast cancer. The myocardial perfusion defects were determined from using single photon emitted computerized tomography (SPECT) myocardial perfusion images. $\underline{Materials\;and\;Methods}$: Between January 2002 and August 2003, 32 patients were enrolled in this study. The patients were diagnosed as having early (AJCC stage T1-T2N0M0) left-sided breast cancer and were treated with tangential irradiation after breast-conserving surgery and systemic chemotherapy. The patients were divided into two groups according to the type of simulation received: two-dimensional simulation using an X-ray fluoroscope simulator or three-dimensional simulation with a CT simulator. All patients underwent technetium-99m-sestamibi gated perfusion SPECT at least 3 years after radiotherapy. The incidence and area of myocardial perfusion defects were evaluated and were compared in the two groups, and at the same time left ventricular ejection fraction and cardiac wall motion were also analyzed. The cardiac volume included in the radiation fields was calculated and evaluated to check for a correlation between the amount of irradiated cardiac volume and aspects of myocardial perfusion defects. $\underline{Results}$: A myocardial perfusion defect was detected in 11 of 32 patients (34.4%). There were 7 (46.7%) perfusion defect cases in 15 patients who underwent the two-dimensional simulation technique and 4 (23.5%) patients with perfusion defects in the three-dimensional simulation group (p=0.0312). In 10 of 11 patients who had myocardial perfusion changes, the perfusion defects were observed in the cardiac apex. The left ventricular ejection fraction was within the normal range and cardiac wall motion was normal in all patients. The irradiated cardiac volume of patients in the three-dimensional simulation group was less than that of patients who received the two-dimensional simulation technique, but there was no statistical significance as compared to the incidence of perfusion defects. $\underline{Conclusion}$: Radiotherapy with a CT simulator (three-dimensional simulation technique) for early left-sided breast cancer may reduce the size of the irradiated cardiac volume and the incidence of myocardial perfusion defects. Further investigation and a longer follow-up duration are needed to analyze the relationship between myocardial perfusion defects and clinical ischemic heart disease.

Clinical Characteristics of Diffuse Panbronchiolitis (미만성 범세기관지염의 임상상에 관한 연구)

  • Kim, Young-Whan;Yoo, Chul-Gyu;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.1
    • /
    • pp.28-34
    • /
    • 1992
  • Background: Diffuse panbronchiolitis (DPB) is a chronic obstructive pulmonary disease distinguished from bronchial asthma, chronic bronchitis, pulmonary emphysema, bronchiectasis, or alveolitis. It is prevalent in Japan, but is known to be rare outside of Japan. Only a few cases in Chinese, Italian, Noirth American and Korean have been reported. During recent two years we have found 16 cases of DPB in Seoul National University Hospital and analyzed the clinical characteristics. Method: We reviewed the patients' age, sex, duration of illness, smoking history, occupational history and past medical history. And we analyzed patients' symptoms, physical signs, laboratory findings and responses to treatment. Results: 1) Male: female ratio was 2.2:1, the ages ranged from 27 to 72 years old, and the duration of disease varied from 1 to 20 years. 2) Most of the patients were being treated as bronchiectasis, miliary tuberculosis, chronic bronchitis or bronchial asthma before they were diagnosed as DPB. 3) Only one patient was a smoker, and 25% of patients had the occupational history of exposure to particles or gas. And all patients had paranasal sinusitis. 4) High resolution computed tomography (HRCT) was very useful in diagnosing the disease in most of the patients. 5) PFT showed obstructive and restrictive abnormalities, and blood gas revealed hypoxemia in most of the patients. 6) Pseudomonas aeruginosa was isolated in the sputum of four patients (25%). 7) The titers of cold hemaglutinin, RA factor and CRP were elevated in most of the patients. 8) Most of the patients improved after treatment with erythromycin. Conclusion: DPB might not be a rare disease in Korea. So DPB should be suspected in a patient who has chronic cough, sputum, dyspnea and diffuse fine nodular chest X-ray abnormality. HRCT and open lung biopsy should be considered in a patient suspected of DPB.

  • PDF

Contributors of the Severity of Airflow Limitation in COPD Patients

  • Hong, Yoon-Ki;Chae, Eun-Jin;Seo, Joon-Beom;Lee, Ji-Hyun;Kim, Eun-Kyung;Lee, Young-Kyung;Kim, Tae-Hyung;Kim, Woo-Jin;Lee, Jin-Hwa;Lee, Sang-Min;Lee, Sang-Yeub;Lim, Seong-Yong;Shin, Tae-Rim;Yoon, Ho-Il;Sheen, Seung-Soo;Ra, Seung-Won;Lee, Jae-Seung;Huh, Jin-Won;Lee, Sang-Do;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.1
    • /
    • pp.8-14
    • /
    • 2012
  • Background: Although airway obstruction in chronic obstructive pulmonary disease (COPD) is due to pathologic processes in both the airways and the lung parenchyma, the contribution of these processes, as well as other factors, have not yet been evaluated quantitatively. We therefore quantitatively evaluated the factors contributing to airflow limitation in patients with COPD. Methods: The 213 COPD patients were aged >45 years, had smoked >10 pack-years of cigarettes, and had a post-bronchodilator forced expiratory volume in one second ($FEV_1$)/forced vital capacity (FVC) <0.7. All patients were evaluated by medical interviews, physical examination, spirometry, bronchodilator reversibility tests, lung volume, and 6-minute walk tests. In addition, volumetric computed tomography (CT) was performed to evaluate airway wall thickness, emphysema severity, and mean lung density ratio at full expiration and inspiration. Multiple linear regression analysis was performed to identify the variables independently associated with $FEV_1$ - the index of the severity of airflow limitation. Results: Multiple linear regression analysis showed that CT measurements of mean lung density ratio (standardized coefficient ${\beta}$=-0.46; p<0.001), emphysema severity (volume fraction of the lung less than -950 HU at full inspiration; ${\beta}$=-0.24; p<0.001), and airway wall thickness (mean wall area %; ${\beta}$=-0.19, p=0.001), as well as current smoking status (${\beta}$=-0.14; p=0.009) were independent contributors to $FEV_1$. Conclusion: Mean lung density ratio, emphysema severity, and airway wall thickness evaluated by volumetric CT and smoking status could independently contribute to the severity of airflow limitation in patients with COPD.

Chest CT Findings of COVID-19 Patients with Mild Clinical Symptoms at a Single Hospital in Korea (경증의 임상 소견을 보이는 COVID-19 환자들의 흉부 CT 소견)

  • Woon Young Baek;Young Kyung Lee;Suhyun Kim;Chorom Hahm;Mi Young Ahn;Dong Hyun Oh;Jae-Phil Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.139-151
    • /
    • 2021
  • Purpose To retrospectively evaluate the chest computed tomography (CT) findings of coronavirus disease 2019 (COVID-19) in patients with mild clinical symptoms at a single hospital in South Korea. Materials and Methods CT scans of 87 COVID-19 patients [43 men and 44 women; median age: 41 years (interquartile range: 26.1-51.0 years)] with mild clinical symptoms (fever < 38℃ and no dyspnea) were evaluated. Results CT findings were normal in 39 (44.8%) and abnormal in 48 (55.2%) patients. Among the 48 patients with lung opacities, 17 (35.4%) had unilateral disease and 31 (64.6%) had bilateral disease. One (2.1%) patient showed subpleural distribution, 9 (18.8%) showed peribronchovascular distribution, and 38 (79.2%) showed subpleural and peribronchovascular distributions. Twenty-two (45.8%) patients had pure ground-glass opacities (GGOs) with no consolidation, 17 (35.4%) had mixed opacities dominated by GGOs, and 9 (18.8%) had mixed opacities dominated by consolidation. No patients demonstrated consolidation without GGOs. Conclusion The most common CT finding of COVID-19 in patients with mild clinical symptoms was bilateral multiple GGO-dominant lesions with subpleural and peribronchovascular distribution and lower lung predilection. The initial chest CT of almost half of COVID-19 patients with mild clinical symptoms showed no lung parenchymal lesions. Compared to relatively severe cases, mild cases were more likely to manifest as unilateral disease with pure GGOs or GGO-dominant mixed opacities and less likely to show air bronchogram.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF