• 제목/요약/키워드: Tomograph

검색결과 57건 처리시간 0.025초

Cone beam형 전산화단층영상과 치근단방사선영상의 치근단 병소에 대한 정량적인 분석 (Quantitative analysis of periapical lesions on cone beam computed tomograph and periapical radiograph)

  • 김진화;이완;김경수;노영채;김대석;이병도
    • Imaging Science in Dentistry
    • /
    • 제39권1호
    • /
    • pp.41-49
    • /
    • 2009
  • Purpose: To detect the progression of experimentally induced periapical lesions on periapical radiograph and cone beam computed tomograph (CBCT) by quantitative analysis. Materials and Methods: After the removal of coronal pulps from premolars of two Beagle dogs, the root canals of premolars were exposed to oral environment during one week and then sealed for 70 days. Digital periapical radiographs and CBCTs were taken at baseline and every 7 days for 77 days after pulp exposure. We examined occurrence and areas of periapical bone resorption. Three comparative groups of CBCT radiographs were prepared by average projection of thin slabs with different bucco-lingual thicknesses (0.1, 3.0, and 8.0 mm) using a 3D visualization software. Radiographic densities were compensated by image normalization. Digital images were processed with mathematical morphology operations. The radiographic density and morphological features of periapical lesions were compared among three groups of CBCT in different time points. Results: In the CBCT group with 0.1 mm thickness, radiographic density (p<0.05) and trabecular bone area (p<0.01) were significantly decreased at the fifth week. However, in the CBCT groups with 3 mm and 8 mm thickness and periapical radiographs, none of densitometric and morphological features showed any significant differences in different time points. Radiographic density of periapical lesion showed increasing tendency at the eleventh week after pulp exposure. Conclusion: Radiographic detection of periapical lesions was possible at the fifth week after pulp contamination by quantitative method and was affected by buccolingual bone thickness.

  • PDF

Cone beam형 전산화단층영상을 이용한 상악동저와 상악제1대구치 치근단괴의 위치관계 (Positional relationship between the maxillary sinus floor and the apex of the maxillary first molar using cone beam computed tomograph)

  • 김경아;고광준
    • Imaging Science in Dentistry
    • /
    • 제38권2호
    • /
    • pp.95-101
    • /
    • 2008
  • Purpose: To assess the positional relationship between the maxillary sinus floor and the apex of the maxillary first molar using cone beam computed tomograph (CBCT). Materials and Methods: CBCTs from 127 subjects were analysed. A total of 134 maxillary first molars were classified according to their vertical and horizontal positional relationship to the maxillary sinus floor and measured according to the distance between the maxillary sinus floor and the maxillary first molar. Results: Type III (The root projected laterally on the sinus cavity but its apex is outside the sinus boundaries) was dominated between 10 and 19 years and type I (The root apex was not in contact with the cortical borders of the sinus) was dominated (P<0.05) between 20 and 72 years on the vertical relationship between the maxillary sinus floor and the apex of the maxillary first molar. The maxillary sinus floor was located more at the apex (78.2%) than at the furcation (21.3%) for the palatal root. The distance from the root apex to the maxillary sinus floor confined to type I was increased according to the ages (P<0.05). Type M (The maxillary sinus floor was located between the buccal and the palatal root) was most common (72.4%) on the horizontal relationship between the maxillary sinus floor and the apex of the maxillary first molar. Conclusion: CBCT can provide highly qualified images for the maxillary sinus floor and the root apex of the maxillary first molar.

  • PDF

전산 시늉에 의한 위그너 함수와 밀도 행렬이 기술 (The description of wigner function and density matrix by computer tomograph)

  • 강장원;조기현;윤선현
    • 한국광학회지
    • /
    • 제11권6호
    • /
    • pp.441-446
    • /
    • 2000
  • Balanced Homodyne Detection 방법으로 국소 진동자의 위상을 조절해 주면서, 각 위상에 대하여 광전류를 측정하여 전류세기의 분포함수를 구하여 이 값을 라돈 역변환을 포함한 Filtered Back Projection하여 빛의 양자역학적 상태를 규정하는 위그너 함수를 구하고 이로부터 간접적으로 밀도행렬을 구한다. 또 위상에 관계없이 구해진 분포함수에서 Pattern함수를 이용하여 밀도행렬을 구할 수 있다. 본 연구에서는 위의 모든 과정을 전산시늉을 통하여 여러 양자역학적 상태 입력 광에 대하여 예측되는 위그너 함수와 밀도 행렬을 구하였다.

  • PDF

반도체 패키지 내부결함 평가 알고리즘의 성능 향상 (Performance Advancement of Evaluation Algorithm for Inner Defects in Semiconductor Packages)

  • 김창현;홍성훈;김재열
    • 한국공작기계학회논문집
    • /
    • 제15권6호
    • /
    • pp.82-87
    • /
    • 2006
  • Availability of defect test algorithm that recognizes exact and standardized defect information in order to fundamentally resolve generated defects in industrial sites by giving artificial intelligence to SAT(Scanning Acoustic Tomograph), which previously depended on operator's decision, to find various defect information in a semiconductor package, to decide defect pattern, to reduce personal errors and then to standardize the test process was verified. In order to apply the algorithm to the lately emerging Neural Network theory, various weights were used to derive results for performance advancement plans of the defect test algorithm that promises excellent field applicability.

Automatic Extraction of Liver Region from Medical Images by Using an MFUnet

  • Vi, Vo Thi Tuong;Oh, A-Ran;Lee, Guee-Sang;Yang, Hyung-Jeong;Kim, Soo-Hyung
    • 스마트미디어저널
    • /
    • 제9권3호
    • /
    • pp.59-70
    • /
    • 2020
  • This paper presents a fully automatic tool to recognize the liver region from CT images based on a deep learning model, namely Multiple Filter U-net, MFUnet. The advantages of both U-net and Multiple Filters were utilized to construct an autoencoder model, called MFUnet for segmenting the liver region from computed tomograph. The MFUnet architecture includes the autoencoding model which is used for regenerating the liver region, the backbone model for extracting features which is trained on ImageNet, and the predicting model used for liver segmentation. The LiTS dataset and Chaos dataset were used for the evaluation of our research. This result shows that the integration of Multiple Filter to U-net improves the performance of liver segmentation and it opens up many research directions in medical imaging processing field.

하악 전치부에서 발생한 선양치성종양의 증례보고 (A case report of Adenomatoid Odontogenic Tumor in the mandibular anterior region)

  • 이병도;이완;권경환;팽준영;손현진
    • Imaging Science in Dentistry
    • /
    • 제39권2호
    • /
    • pp.99-102
    • /
    • 2009
  • Adenomatoid odontogenic tumor (AOT) is a tumor of odontogenic epithelium with varying degrees of inductive changes in the connective tissue. The common radiographic appearance of AOT is a unilocular radiolucency associated with an unerupted tooth. Detectable radiopacities have been reported in many cases. We present a case of AOT in a 9-year old-female patient. Cystic lesion with numerous, punctuate radiopaque foci was observed on the anterior region of the mandible. These radiopacities were situated mostly on the buccal side of impacted tooth on the multi-planar images of cone beam computed tomograph. Characteristic duct like structures and amyloid like material were observed on histopathologic finding. (Korean J Oral Maxillofac Radiol2009; 39 : 99-102)

  • PDF

하악에 발생된 Ewing 육종의 1증례 (A CASE REPORT OF EWING′S SARCOMA OF THE MANDIBLE)

  • 박상억;박미경;최갑식
    • 치과방사선
    • /
    • 제22권1호
    • /
    • pp.161-168
    • /
    • 1992
  • The authors observed a 27-year-old male patient who came to the Infirmary of Kyungpook National University Hospital who had complained of dull pain in right mandibular angle area 1 month ago. As a result of careful analysis of clinical, radiological, and histopathological findings, the authors diagnosed it as Ewing's sarcoma and obtained the results as follows: 1. In clinical examination, main clinical symptoms were continuous dull pain and gingival swelling on the 2nd and 3rd molar area of the right mandible. 2. In radiographic examination, ill-defined radiolucent area was seen on mandibular right angle area, and apparent periosteal reaction of sun-ray spicule was emanated from the lingual cortex of mandibular angle area. And computed tomograph also revealed moderate-defined 3. soft tissue mass of the same area. In histopathological examination, small round-shaped, and closely packed cells with scanty cytoplasm were observed in this specimen, and positive reaction in PAS staining was also observed.

  • PDF

Severe bony ankylosis of the temporomandibular joint on one side and contralateral adhesion: A case report

  • Song, Ji-Young;Kim, Seong-Gon;Choi, Hang-Moon;Kim, Hyun Jung
    • Imaging Science in Dentistry
    • /
    • 제45권2호
    • /
    • pp.103-108
    • /
    • 2015
  • Bony fusion between the mandibular condyle and skull base involves temporomandibular joint (TMJ) bony ankylosis. This condition might originate from trauma, infection, or systemic disease. TMJ adhesion can develop after synovial damage. Both TMJ ankylosis and adhesion lead to functional impairment and pain. Here, we present a case of a 50-year-old female who had bony ankylosis of the right TMJ and adhesion of the left TMJ. She had otitis media in the right ear. A large mass in the right TMJ was observed on computed tomograph. Magnetic resonance image showed a large fused bone mass with normal bone marrow in the right TMJ and flattening of the condyle with a thin disk in the left TMJ. Gap arthroplasty with temporal fascia was performed on the right TMJ, and discectomy, high condylectomy, and coronoidectomy were performed on the left TMJ. During a 2-year follow-up after surgery, the patient had no recurrence.

Florid osseous dysplasia in a middle-aged Turkish woman: A case report

  • Onder, Buket;Kursun, Sebnem;Oztas, Bengi;Baris, Emre;Erdem, Erdal
    • Imaging Science in Dentistry
    • /
    • 제43권3호
    • /
    • pp.197-200
    • /
    • 2013
  • Florid osseous dysplasia (FOD) is an uncommon, benign, cemento-osseous lesion of the jaws. The etiology of FOD is still unknown. It is often asymptomatic and may be identified on routine dental radiographs. The classic radiographic appearance of FOD is amorphous, lobulated, mixed radiolucent/radiopaque masses of cotton-wool appearance with a sclerotic border in the jaws. In our case the lesion was found incidentally on routine periapical radiographs taken for restored teeth and edentulous areas. For further and detailed examination, a panoramic radiograph and cone-beam computed tomograph (CBCT) were taken. The panoramic radiograph and CBCT revealed maxillary bilateral and symmetrical, non-expansile, well-defined, round, radiopaque masses in contact with the root of the maxillary right second molar and left first molar teeth. Our aim in presenting this case report was to highlight the importance of imaging in diagnosis of FOD.

영상진단 수가 변화가 의료공급자 진료행태에 미치는 영향: 전산화단층영상진단 검사건수를 중심으로 (The Impact of Diagnostic Imaging Fee Changes to Medical Provider Behavior: Focused on the Number of Exams of Computed Tomograph)

  • 조수진;김동환;윤은지
    • 보건행정학회지
    • /
    • 제28권2호
    • /
    • pp.138-144
    • /
    • 2018
  • Background: Diagnostic imaging fee had been reduced in May 2011, but it was recovered after 6 months because of strong opposition of medical providers. This study aimed to analyze the behavior of medical providers according to fee changes. Methods: The National Health Insurance claims data between November 2010 and December 2012 were used. The number of exams per computed tomography was analyzed to verify that the fee changes increased or decreased the number of exams. Multivariate regression model were applied. Results: The monthly number of exams increased by 92.5% after fee reduction, so the diagnostic imaging spending were remained before it. But medical provider decreased the number of exams after fee return. After adjusting characteristic of hospitals, fee reduction increased the monthly number of exams by 48.0% in a regression model. Regardless type of hospitals and severity of disease, the monthly number of exams increased during period of fee reduction. The number of exams in large-scaled hospitals (tertiary and general hospital) were increased more than those of small-scaled hospitals. Conclusion: Fee-reduction increased unnecessary diagnostic exams under the fee-for-service system. It is needed to define appropriate exam and change reimbursement system on the basis of guideline.