• Title/Summary/Keyword: Tomograph

Search Result 57, Processing Time 0.035 seconds

Radiographic Study of Bony Changes of the Mandibular Condyle (하악과두의 골변화에 관한 방사선학적 비교연구)

  • Kim Kyung-A;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.30 no.1
    • /
    • pp.23-32
    • /
    • 2000
  • Purpose : The purpose of this study is to compare radiographic techniques for the diagnostic accuracy in the detection of osteophytes of the mandibular condyle. Material and Methods : A series of bone chips were placed at four locations on the condylar head of a dried human skull. Eight radiographic techniques such as panoramic, transcranial, infracranial, transorbital, reverse-Towne's, submentovertex, multidirectional tomographic and computed tomographic techniques were compared. Three oral radiologists were asked to rate the lesions by four stage score. The statistical analysis was performed by ANOVA test. Results: For the detection of lateral osteophyte, transcranial, infracranial, transorbital and reverse-Towne' s views showed superiority. Also, transcranial and infracranial views showed superiority for medial osteophyte. While for the detection of superior and anterior osteophyte, panoramic, transcranial, infracranial, transorbital views showed superiority. Lateral tomograph showed superiority for the detection of superior and anterior osteophyte, but it showed inferiority for lateral and medial osteophyte. And antero-posterior tomograph showed superiority for the detection of all osteophytes. Axial computed tomograph showed superiority for the detection of all osteophytes, and coronal computed tomograph showed superiority for lateral, medial and superior osteophytes. While reconstructed sagittal computed tomograph showed relatively superiority for the detection of anterior and superior osteophytes. Conclusion : The conventional radiographs can be used for the detection of bony changes of the mandibular condyle, and tomograph or computed tomograph can be used additionally when it is difficult to detect bony changes on conventional radiographs.

  • PDF

The Health Analysis of Protected Tree 'Zelkova serrata' Using an Ultrasonic Tomograph (느티나무 보호수의 내부 단층 진단을 통한 건강 분석)

  • Kang, Banghun;Cho, Seung-Jin;Son, Jinkwan;Kim, Nam-Choon;Kim, Mi-Heui
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.17 no.2
    • /
    • pp.73-83
    • /
    • 2014
  • This study was conducted to evaluate defects in Zelkova serrata trees using an ultrasonic tomograph (PICUS) and suggest a management plan to maintain it as a natural and cultural resource. In previous study, health information of 16 protected trees were obtained by surveying the following categories; tree appearance, crown, bark, root exposure, water and nutrition, deterioration, pest, vitality, ground status, and pollutant. The average score of health was 16.5 in 16 trees, which means that general monitor is needed for management. In this study, the evaluation result of tree's inside defects using an ultrasonic tomograph showed that 43.8% of decay rate has been found in 16 trees. In fact, some trees look to be good even though they actually have a defects causing broken by natural disaster such as strong wind. Therefore, it is urgent to put some support to the trees and come up with a protective plan. The results of this study would be useful as basic data in developing a guideline for the efficient conservation and management of big and old trees.

Precision Evaluation of GPS PWV and Production of GPS PWV Tomograph during Foul Weather (악천후시 GPS PWV의 측정 정밀도 검증 및 GPS PWV 변화도 작성)

  • 윤홍식;송동섭
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.04a
    • /
    • pp.69-74
    • /
    • 2003
  • GPS/Meteorology technique for PWV monitoring is currently actively being researched an advanced nation. But, there is no detailed research on an evaluation of precision of GPS derived PWV measurements during the period of foul weather condition. Here, we deal with the precision of GPS derived PWV during the passage of Typhoon RUSA. Typhoon RUSA which caused a series damage was passed over in Korea from August 30 to September 1, 2002. We compared th tropospheric wet delay estimated from GPS observation and radio-sonde data at four sites(Suwon, Kwangju, Taegu, Cheju). The mean standard deviation of PWV differences at each site is ${\pm}$0.005mm. We also obtained GPS PWV at 13 GPS permanent stations(Seoul, Wonju, Seosan, Sangju, Junju, Cheongju, Taegu, Wuljin, Jinju, Daejeon, Mokpo, Sokcho, Jeju). GPS PWV time series shows, in general, peak value before and during th passage of RUSA, and low after the RUSA. GPS PWV peak time at each station is related to the progress of a typhoon RUSA. We obtained very similar result as we compare GMS satellite image with tomograph using GPS PWV and we could present th possibility of practical use by numerical model for weather forecast.

  • PDF

The Intelligence Algorithm of Semiconductor Package Evaluation by using Scanning Acoustic Tomograph (Scanning Acoustic Tomograph 방식을 이용한 지능형 반도체 평가 알고리즘)

  • Kim J. Y.;Kim C. H.;Song K. S.;Yang D. J.;Jhang J. H.
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.91-96
    • /
    • 2005
  • In this study, researchers developed the estimative algorithm for artificial defects in semiconductor packages and performed it by pattern recognition technology. For this purpose, the estimative algorithm was included that researchers made software with MATLAB. The software consists of some procedures including ultrasonic image acquisition, equalization filtering, Self-Organizing Map and Backpropagation Neural Network. Self-Organizing Map and Backpropagation Neural Network are belong to methods of Neural Networks. And the pattern recognition technology has applied to classify three kinds of detective patterns in semiconductor packages: Crack, Delamination and Normal. According to the results, we were confirmed that estimative algorithm was provided the recognition rates of $75.7\%$ (for Crack) and $83_4\%$ (for Delamination) and $87.2\%$ (for Normal).

  • PDF

GPS PWV Variation Research During the Progress of a Typhoon RUSA (태풍 RUSA의 진행에 따른 GPS PWV 변화량 연구)

  • 송동섭;윤홍식;서애숙
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.21 no.1
    • /
    • pp.9-17
    • /
    • 2003
  • Typhoon RUSA, which caused serious damage was passed over in Korea peninsula during 30 August to 1 September, 2002. We estimated tropospheric wet delay using GPS data and meteorological data during this period. Integrated Water Vapor(IWV) gives the total amount of water vapor from tropospheric wet delay and Precipitable Water Vapor(PWV) is calculated the IWV scaled by the density of water. We obtained GPS PWV at 13th GPS permanent stations(Seoul, Wonju. Seosan, Sangju, Junju, Cheongju, Taegu, Wuljin, Jinju, Daejeon, Mokpo, Sokcho, Jeju). We retrieve GPS data hourly and use Gipsy-Oasis II software and we compare PWV and precipitation. GPS observed PWV time series demonstrate that PWV is, in general, high before and during the occurrence of the typhoon RUSA, and low after the typhoon RUSA. GPS PWV peak time at each station is related to the progress of a typhoon RUSA. We got very near result as we compare GMS Satellite image with tomograph using GPS PWV and we could present practical use possibility by numerical model for weather forecast.

Development of Tomograph Technique for Evaluating Thickness Reduction using Noncontact Ultrasonic Sensor Network (두께감육 평가를 위한 비접촉식 초음파 센서 네트워크를 이용한 토모그래프 기술 개발)

  • Lee, J.M.;Kim, Y.K.;Park, I.K.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.1
    • /
    • pp.27-31
    • /
    • 2014
  • This paper describes a tomographic imaging technique for evaluating the thickness reduction of a plate-like structure using a noncontact sensor network based on an electromagnetic acoustic transducer that generates shear horizontal plate waves. Because this technique is based on the effect of mode cutoff and time of flight of guided waves caused by a change in thickness, the tomographic image provides information on the presence of defects in the structure. To verify the performance of the method, artificial defects with various thickness reduction ratios were machined in an aluminum plate, and the tomographic imaging results are reported. The results show that the generated tomographic image displays the thickness reductions and can identify their locations. Therefore, the proposed technique has good potential as a tool for health monitoring of the integrity of plate-like structures.

A STUDY OF THE MANDIBULAR CONDYLE SHAPE ON THE INDIVIDUALIZED CORRECTED TMJ TOMOGRAPH AND SUBMENTOVERTEX RADIOGRAPH (이하두정방사선사진과 개별화 단층방사선사진을 이용한 하악과두의 형태에 관한 연구)

  • 이상래
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.227-236
    • /
    • 1994
  • The purpose of this study was to observe mandibular condyle shape in an asymptomatic population. In order to carry out this study, 96 temporomandibular joints in 48 adults(22 males, 26 females), who were asymptomatic for temporomandibular disturbances and had no history of prosthodontic or orthodontic treatments, were selected, and radiographed using the Sectograph(Denar Co., U.S.A.) for lateral and frontal individualized corrected TMJ tomograph and submentovertex radiograph. Mandibular condyles were classified morphologically, and measured medioateral and anteroposterior dimensions and condylar angulation. The obtained results were as follows. 1. In the classification of condyle shape on lateral tomographs, 94.8% were convex type and 5.2% were angled type. 2. In the classification of condyle shape on frontal tomographs, 45.3% were convex type, 32.0% were round type, 16.0% were flat type, and 6.7% were angled type. 3. In the classification of condyle shape on submentovertex radiographs, 34.5% were flat-convex type, 22.9% were flat-flat type, 20.8% were concave-convex type, 19.8% were convex-convex type, and 1.0% were concave-flat type and convex-flat type. Concave-concave type, convex-concave type, and flat-concave type were not observed. 4. The average mediolateral legth of the condyle was 19.3㎜ and the average anteroposterior length was 9.4㎜. The average angle between the long axis of condyle and the coronal plane made on submentovertex view was 19.6 degrees.

  • PDF

A Pilot Study on the Usefulness of Tomography and Bone Scan in Diagnosis of Patients with TMJ Osteoarthritis (측두하악관절 골관절염 환자의 진단에서 단층촬영과 골스캔 검사의 유용성에 대한 예비연구)

  • Kim, Cheul;Kim, Young-Jun;Moon, Ji-Hoi;Park, Moon-Soo
    • Journal of Oral Medicine and Pain
    • /
    • v.37 no.2
    • /
    • pp.125-133
    • /
    • 2012
  • TMJ Osteoarthritis is a degenerative disease caused by overload on joint tissue, and often accompany with local tenderness on the joint, crepitus by mandibular movement, restriction of mandibular movement, and anterior openbite. In general, panoramic radiography, TMJ panoramic radiography, and transcranial radiography are conducted to diagnose osteoarthritis after clinical examination, however, these radiographic evaluations are limited in detecting minute bony changes of early pathologic lesion. The aim of this pilot study was to evaluate the limitation and usefulness of several TMJ imaging techniques, so we compare the findings from clinical examination, plain film radiographs, tomograph, and bone scan from 81 patients with temporomandibular joint disorder. The proportion of patients showing same findings in plain film radiographs, TMJ tomograph, and bone scan was high, however, it is desirable that clinician should conduct phased imaging examinations according to the clinical findings due to the possibilities of false negative findings in diagnosis of osteoarthritis.

POSITIONAL RELATIONSHIP OF THE MANDIBULAR CANAL AND IMPACTED THIRD MOLARS BY USING DENTAL CONE BEAM COMPUTED TOMOGRAPHY (제3대구치와 하악관과의 위치 관계에서 치과용 Cone beam CT의 유용성)

  • Chu, Yeon-Gyu;Park, Young-In;Kim, Jin-Wook;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.6
    • /
    • pp.492-498
    • /
    • 2009
  • We sought to evaluate the relationship between the mandibular canal and impacted mandibular third molars by using dental cone beam computed tomograph(CBCT) for third molar surgery. A total of 111 patients(177 teeth) offered the images through CBCT and panoramic radiography for the extraction of the mandibular third molars. In CBCT, the accurate relationship between the third molar and the mandibular canal were evaluated. In panoramic radiographies, we evaluated the impacted level and superimposition sign of the mandibular third molar with the mandibular canal, and also, the radiopacity of the white line in the canal. Data were statistically analyzed and estimated by $X^2$-test. In CBCT finding, high prevalence of contact between the mandibular canal and roots occured in the deep impacted third molars, narrowing mandibular canals, bending mandibular canals and cases where the radiopacity of white line of canals were "absence" on panoramic images. It showed statistical significance (P<0.05). When evaluating the mandibular canal and the roots through the panoramic radiography for third molar extraction, it could be difficult to diagnosis accurately. Thus, it is required to have an accurate diagnostic approach through CBCT that could evaluated the location between mandibular canal and root.