• Title/Summary/Keyword: Toluene Recovery

Search Result 79, Processing Time 0.027 seconds

A Study on Performance of Protective Gloves to Isocyanate Toxicity (이소시안화물 독성에 대한 보호장갑의 성능 연구)

  • Lee, Su-Gil;Pisaniello, Dino;Lee, Nae-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.62-69
    • /
    • 2008
  • As the concerns of dermal exposure of spray painters to isocyanates in the automobile industry, glove performance was examined like permeation rate and breakthrough time including fatigue test. Methylene chloride was used as the solvent for derivatization of the isocyanates with a 97.5% recovery. Ghost wipe pads were used to wipe the surface of the glove material after chemical penetration through the glove material placed under a disposable test cell. Several solvents were tested, such as thinner(xylene, toluene) and cleaning agent(acetone) by using a standard permeation test cell(AS/NZS standard 2161. part 10.3). Solvents accelerate chemical permeation through the gloves more quickly than pure HDI hardener products. The longest breakthrough times were from Nitrosolve gloves, not detected in 8 hours, compared with others like Latex, Neoprene, TNT and Dermo Plus. Therefore Nitrosolve gloves could be recommended as personal protective equipment in crash repair shops. In addition, revised exposure limit of korean regulation should be suggested for employee to minimize the risk of health symptoms.

High-Purity Purification of 2,6-Dimethylnaphthalene (2,6-DMN) in Light Cycle Oil - Purification of 2,6-DMN from Concentrate of DMN Isomers by Crystallization - (접촉분해경유 중의 2,6-dimethylnaphthalene (2,6-DMN)의 고순도 정제 - 결정화에 의한 DMN 이성체 농축액 중의 2,6-DMN의 정제 -)

  • Kim, Su Jin;Jeong, Hwa Jin
    • Applied Chemistry for Engineering
    • /
    • v.19 no.1
    • /
    • pp.105-110
    • /
    • 2008
  • The high-purity purification of 2,6-dimethylnaphthalene (2,6-DMN, 10.43 wt%) from the concentrate of DMN isomers recovered from light cycle oil (LCO) through distillation-extraction combination was examined by a crystallization operation. To select the most suitable crystallization solvent for purification of 2,6-DMN, several conventional solvents, which have been employed commercially as crystallization solvents for high-purity performance, were tested, through measurement of purity and yield of 2,6-DMN. The solvents used were acetone, cyclohexanone, ethanol, ethyl ether, ethyl acetate, isopropyl ether, methanol, n-hexane, n-heptane, pyridine, THF, toluene, and a mixture of methanol and acetone. The mixture of 60 vol% methanol and 40 vol% acetone (M/A = 1.5) was found to be suitable for purification of 2,6-DMN in the concentrate of DMN isomers based on purity and yield. Increasing the operation temperature and the volume ratio of solvent (M/A = 1.5) to feed (concentrate of DMN) resulted in improving the purity of 2,6-DMN, whereas the yield decreased. The crystal recovered by crystallization run using the concentrate of DMN isomers contained about 76 wt% 2,6-DMN. Furthermore, for recovery of high-purity 2,6-DMN, crystal containing 76 wt% 2,6-DMN was crystallized. As a result, crystal with 99.7 wt% 2,6-DMN was recovered with 40% yield.

Fixation of Sericin of Silk Fabric by Epoxy Resin (Epoxy수지에 의한 견직물의 Sericin정착)

  • 문영배;남중희
    • Journal of Sericultural and Entomological Science
    • /
    • v.26 no.2
    • /
    • pp.16-25
    • /
    • 1984
  • The sericin fixation of silk fabrics by epoxy resins was studied in the presence of aqueous salt solution in different solvents at the indicated temperature for the desired time. Heavy weight gains were obtained in the reaction with glycerol diglycidyl ether (EX-313) and ethylene glycol diglycidyl ether (EX-810) catalyzed by potassium thiocyanate in such solvents as carbon tetrachloride and p-chloroethylene. The obtained results were summarized as follows; 1) The tested resins were found similar in reaction behavior to silk fabric. The effect of fixation and weight gains was higher in EX-810 than EX-313. 2) The weight gains were increased with reaction time and temperature, and degumming ratio reached a constant value in 90 min at 70$^{\circ}C$. 3) The weight gains and the degumming ratio reached an equilibrium at 3-5% of epoxy concentration. 4) The weight gains were remarkably influenced and increased by the concentration of salt solution. The degumming ratio reached an equilibrium over 0.5N concentration of salt. 5) The weight gains were increased with the dipping time in gently-sloping. The degumming ratio reached an equilibrium over 15 min dipping. 6) The effect of sericin fixation of hydrophobic solvents, such as Carbon Tetrachloride, p-Chloroeth-ylene, Cyclohexane, Xylene and Toluene, was found suitable. 7) The effect of drying temperature was not remarkable on the weight gains and the degumming ratio. 8) There was a slight decrease in the moisture regain of sericin-fixed silk and it may be possible to maintain the moisture regain in the sericin-fixed silk by the epoxy resins. 9) The results on testing physical properties of sericin-fixed silk fabric were as follows; The crease recovery was almost not different from undegummed fabric, but inferior to degummed fabric. The tensile strength was improving in accordance with the effect of sericin fixation, either the elongation did.

  • PDF

A Study on Organic Solvent Measurement Using Diffusive Sampler (확산포집기를 이용한 공기 중 유기용제 포집에 관한 연구)

  • Park, Mi Jin;Yoon, Chung Sik;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.208-223
    • /
    • 1994
  • The purpose of this study was to evaluate the efficiency of diffusive(or passive) sampler in measuring airbone organic solvents. Diffusive samplers are generally simple in construction and do not require power for operation. The efficiency of the diffusive samplers has not sufficiently been investigated in Korea. Three types of samplers were studied in this study. The sampling and analytical results by passive samplers were compared with results by charcoal tube method recommended by NIOSH(National Institute for Occupational Safty and Health). The following characteristics are identified and studied as critical to the performance passive monitors; recovery, reverse diffusion, storage stability, accuracy and precision, face velocity and humidity, n-Hexane, TCE(trichloroethylene) and toluene were used as test vapors. A dynamic vapor exposure system consisting of organic vapor generator and sampling chamber for evaluating diffusive samplers are made. The results of the study are summarized as follows. 1. NIOSH recommands that the overall accuracy of a sampling method in the range of 0.5 to 2.0 times the occupational health standard should be ${\pm}25$ percent for 95 percent confidence level. Among three types of diffusive samplers, sampler A has permeation membrane and samplers Band C have diffusive areas, samplers A and B met the criterion that overall accuracy for 95% confidence level of the samplers were within ${\pm}25$ percent of the reference value. Sampler C had overall accuracy ${\pm}9.6%$ and ${\pm}11.8%$ in hexane and TCE, respectively. The concentration of toluene was overestimated in sampler C with overall accuracy of ${\pm}43.9%$. 2. The desorption efficiencies of diffusive samplers were 96-107%. 3. There was no significant sampe loss during four weeks of storage both with and without refrigeration. 4. There was no significant reverse diffusion, when the samplers were exposure to clean air for 2 hours after sampling for 2 hours at the level of 2 TLY. 5. In case of 8 hours sampling, relative differences(RD) of concentrations between charcoal tube method and diffusive method were 15-39%, 13-46%, and 4-35% for sampler A, B and C, respectively. The performance was poor in 8 hours sampling for multiple substance monitors. 6. At high velocity(100 cm/sec), samplers B and C overestimated the concentrations of organic vapors, and sampler A with permeation membrance gave better results. 7. At 80% relative humidity, samplers showed no siginificant effect. Low humidity also did not affect the diffusive samplers.

  • PDF

Determination of hazardous semi-volatile organic compounds in industrial wastewater using disk-type solid-phase extraction and GC-MS (디스크형 고상 추출법과 GC/MS를 이용한 공장폐수 중 반휘발성유기화합물질 분석)

  • Lee, In-Jung;Lim, Tae-Hyo;Heo, Seong-Nam;Nam, Su-Gyeong;Lee, Jae-Gwan;Cheon, Se-Uk
    • Analytical Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.236-241
    • /
    • 2012
  • There are many industrial factories in the central Nakdong river basin and have been occurred water pollution accidents by hazardous chemicals such as phenol, 1,4-dioxane and perchlorate. In this study, ten compounds of semi-volatile organic compounds (SVOCs) (dichlorvos, toluene-2,4-diisocyanate, 4,4'-methylenedianiline, 4,4'-methylenebis (2-chloroaniline), diethyl phthalate, di-n-butyl phthalate, butyl benzyl phthaltate, bis (2-ethylhexyl) adipate, benzophenone, 4,4'-bisphenol A) of hazardous chemicals which may be potentially discharged into the Nakdong river, were determined by gas chromatography-mass spectrometry (GC-MS) with disk-type solid-phase extraction. Accuracy and precision were in the range of 75.6~110.5%, and 4.6~12.7%, respectively and recovery was in the range of 72.4~127.9%. Three compounds (bis (2-ethylhexyl)adipate, benzophenone, 4,4'-bisphenol A) were detected in industrial wastewater such as wastewater treatment plants (WWTPs) and wastewater discharge facilities in the Nakdong River basin.

Removal of residual VOCs in a collection chamber using decompression for analysis of large volatile sample

  • Lee, In-Ho;Byun, Chang Kyu;Eum, Chul Hun;Kim, Taewook;Lee, Sam-Keun
    • Analytical Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.23-35
    • /
    • 2021
  • In order to measure the volatile organic compounds (VOCs) of a sample which is too large to use commercially available chamber, a stainless steel vacuum chamber (VC) (with an internal diameter of 205 mm and a height of 50 mm) was manufactured and the temperature of the chamber was controlled using an oven. After concentrating the volatiles of the sample in the chamber by helium gas, it was made possible to remove residual volatile substances present in the chamber under reduced pressure ((2 ± 1) × 10-2 mmHg). The chamber was connected to a purge & trap (P&T) using a 6 port valve to concentrate the VOCs, which were analyzed by gas chromatography-mass spectrometry (GC-MS) after thermal desorption (VC-P&T-GC-MS). Using toluene, the toluene recovery rate of this device was 85 ± 2 %, reproducibility was 5 ± 2 %, and the detection limit was 0.01 ng L-1. The method of removing VOCs remaining in the chamber with helium and the method of removing those with reduced pressure was compared using Korean drinking water regulation (KDWR) VOC Mix A (5 μL of 100 ㎍ mL-1) and butylated hydroxytoluene (BHT, 2 μL of 500 ㎍ mL-1). In case of using helium, which requires a large amount of gas and time, reduced pressure ((2 ± 1) × 10-2 mmHg) only during the GC-MS running time, could remove VOCs and BHT to less than 0.1 % of the original injection concentration. As a result of analyzing volatile substances using VC-P&T-GC-MS of six types of cell phone case, BHT was detected in four types and quantitatively analyzed. Maintaining the chamber at reduced pressure during the GC-MS analysis time eliminated memory effect and did not affect the next sample analysis. The volatile substances in a cell phone case were also analyzed by dynamic headspace (HT3) and GC-MS, and the results of the analysis were compared with those of VC-P&T-GC-MS. Considering the chamber volume and sample weight, the VC-P&T configuration was able to collect volatile substances more efficiently than the HT3. The VC-P&T-GC-MS system is believed to be useful for VOCs measurement of inhomogeneous large sample or devices used inside clean rooms.

Fabrication and Characterization of Polyurethane Foam for Wound Dressing (창상치료용 폴리우레탄 폼의 제조 및 특성연구)

  • Kim, Won-Il;Kim, Cheol-Joo;Kim, Dae-Yeon;Kwon, Oh-Kyoung;Kwon, Oh-Hyeong
    • Polymer(Korea)
    • /
    • v.34 no.5
    • /
    • pp.442-449
    • /
    • 2010
  • Polyurethane(PU) prepolymer was synthesized from ethylene oxide/propylene oxide(EO/PO) random polyether polyol, toluene diisocyanate and chain extender such as ethylene glycol and 1,4-butanediol. PU foams having various compositions were fabricated from PU prepolymers with different hard segment contents(%) and mixed foaming solution of different compositions. PU foam from chain extender-introduced PU prepolymer and mixed foaming solution containing glycerin showed better mechanical property than other groups. Various PU foams were tested on their mechanical property, moisture vapor transmission rate, absorption speed, absorptivity, morphology and cell culture test. According to the test, the PU foam fabricated from chain extender-introduced PU prepolymer and mixed foaming solution containing optimum composition of F-68, glycerin and CMC was found to have the best property for wound dressing materials. From in vivo animal study, it was confirmed that above PU foam showed rapid wound recovery.

A Study on the Analytical Errors of Non-proficient Laboratories Participated in Quality Control Program (작업환경측정기관의 정도관리를 통한 분석능력이 미흡한 기관들의 분석오차 유발요인에 관한 고찰)

  • Park, D.W.;Shin, Y.C.;Park, S.H.;Lee, N.R.;Oh, S.M.;Yoon, C.S.;Paik, N.W.
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.96-102
    • /
    • 1994
  • Factors affecting non-proficient analytical ability were compared and evaluated by rating of laboratories and round. Analyst Indices between proficient and non-proficient participants were different. Coefficients of determination($R^2$) for standard of toluene, xylene and trichloroethylene of the 4th round between some proficient and non-proficient participants were significantly different(p<0.05). But, there was no difference in the 5th round. Average desorption efficiency of non-proficient participants was 88%-98%, which was lower than 96%-100% of some randomly selected proficient participants. Also non-proficient participants have a large variance of desorption efficiency, 11.79-19.69%. In the 5th round, desorption efficiency of metyl iso-butyl ketone(MIBK) reported by all participants was lower than 90% tested by NIOSH and especially low compared to other analytes. Participants evaluated to be non-proficient in the metal part have 85%-100.84% of average recovery, which was larger variance than 98% of some proficient participants. Although it is difficult to find quantitatively factors causing non-proficiency in analytical ability, pretreatement techniques and experience of analyst seems to be more important factors to produce accurate analytical result.

  • PDF

Analysis of Dry Process Products for Recycling of Spent Secondary Batteries (폐 이차전지 리사이클링을 위한 건식공정 생성물 분석)

  • Kim, Jinhan;Kim, Yongcheol;Oh, Seung Kyo;Jeon, Jong-Ki
    • Clean Technology
    • /
    • v.27 no.2
    • /
    • pp.139-145
    • /
    • 2021
  • The purpose of this study is to recover valuable metals from spent batteries using a dry process. We focused on the effect of the smelting temperature on the composition of recovered solid and liquid products and collected gaseous products. After removal of the cover, the spent battery was left in NaCl solution and discharged. Then, the spent battery was made into a powder form through a crushing process. The smelting of the spent battery was performed in a tubular electric furnace in an oxygen atmosphere. For spent lithium-ion batteries, the recovery yield of the solid product was 80.1 wt% at a reaction temperature of 850 ℃, and the final product had 27.2 wt% of cobalt as well as other metals such as lithium, copper, and aluminum. Spent nickel-hydrogen batteries had a recovery yield of 99.2 wt% at a reaction temperature of 850 ℃ with about 37.6 wt% of nickel and other metals including iron. For spent nickel-cadmium batteries, the yield decreased to 65.4 wt% because of evaporation with increasing temperature. At 1050 ℃, the recovered metals were nickel (41 wt%) and cadmium (12.9 wt%). Benzene and toluene, which were not detected with the other secondary waste batteries, were detected in the gaseous product. The results of this study can be used as basic data for future research on the dry recycling process of spent secondary batteries.

Study on establishment of emission cell test method for liquid phase building materials (방출셀을 이용한 액상건축자재 오염물질 방출시험방법 정립에 관한 연구)

  • Lim, Jungyun;Jang, Seongki;Seo, Sooyun
    • Analytical Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.191-200
    • /
    • 2009
  • The aim of this study was to evaluate and establish of emission test method for liquid phase building materials such as paint, adhesive, sealant by emission cell. A small-scale emission chamber and emission cell were used to evaluate emission of TVOC from paint, adhesive, sealant. The quantity of TVOC emission were measured by a gas chromatography/mass spectrometry (GC/MS). Background concentration of TVOC was below $10{\mu}g/m^3$ in the emission chamber and cell. Air tightness and recovery in chamber and cell showed good results. The recovery of thermal desorber for toluene and n-dodecane were about 120%. The repeatability of response factor and retention time in GC/MS below 30%. The method detection limit of VOCs ranged 0.04~8.82 ng. The concentration of TVOC emission using emission cell was 1.35~1.41 times higher than emission chamber. The correlation of TVOC emission using chamber and cell method was significantly high (r=0.91~0.97).