• Title/Summary/Keyword: Titanium investment casting

Search Result 18, Processing Time 0.021 seconds

THE EFFECT OF CASTING MACHINE AND INVESTMENT ON THE CASTABILITY OF TITANIUM ALLOY (주조기와 매몰재의 성분변화에 따른 티타늄의 주조성에 관한 연구)

  • Chung, Da-Woon;Yang, Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.654-664
    • /
    • 2006
  • Statement of problem: There has been a eat interest in the use of titanium for fixed and removable prostheses in recent because of its excellent biocompatibility. However, the melting temperature and chemical reactivity of titanium necessities casting system different from those used in conventional casting. The current titanium casting systems are based on an electric-arc design for melting the metal in an argon atmosphere and its exclusive investment. Despite the new development in Ti casting system, inadequate mold filling and internal porosity are frequently observed casting defects. Purpose : The purposes of this study were to compare the castibility and reaction layer of the casting titanium under the two casting machines and their investment condition. Material and method: coping and machine-milled titanium coping according to the casting methods and the marginal configurations. The total 28 specimens were used, and these are divided into 4 groups according to 2 casting machines and 2 investments. The castings were analyzed using x-ray microanalysis and microhardness testing. The reaction layer between margin of titanium casting and the investments was observed and analyzed with scanning electron microscope. Result: 1. Castabiliy of casting titanium specimen was best in the group of centrifugal casting machine and Selevest $CB^{\circledR}$ and good that of Selevest CB and pressure differential casting machine, Rematitan plus and centrifugal casting machine, Rematitan plus and pressure differential casting machine in order. 2. There was no significanct correlation in titanium castability in respect of casting machine. However ANOVA indicated that Selevest $CB^{\circledR}$ groups had significantly better castability than Rematitan $plus^{\circledR}$ groups.(p<0.05) 3. There was a significant microhardness difference between centrifugal casting machine groups and pressure differential groups.(p<0.05) Titanium castings in centifugal groups had significantly harder than those in pressure differential groups. 4. The addition of zirconia decreased interfacial reactivity. Conclusion: above result revealed that of the castability of titanium casting specimens had little correlation in casting machines and was better in magnesia-based investment contained ZrO2 groups. However in order to practice casting titanium in clininic, its castability should be improved, also there should be more research on factor of castability so that long-span prothesis and removable partial denture metla frame may be casted completly.

Metal-Mold Reaction and Surface Roughness Measurement of Pure Titanium Casting Specimens with Mold Temperatures (순수 티타늄 주조체의 주형온도에 따른 용탕반응성 및 표면거칠기)

  • Cha, Sung-Soo;Song, Young-Ju;Park, Soo-Chul
    • Journal of Technologic Dentistry
    • /
    • v.32 no.4
    • /
    • pp.297-305
    • /
    • 2010
  • Purpose: The purpose of this study was to observe the change of metal-mold reaction and surface roughness in titanium casting specimens for phosphate-silica alumina bonded investment with mold temperatures. Methods: The metal-phosphate silica alumina bonded mold interface reaction and surface roughness of titanium casting specimens according to mold temperatures were investigated. The Specimens were analysed by scanning electron microscopy and surface roughness tester. Results: The oxidation behavior indicated by the growth of oxide thickness. The titanium-oxide layer were consisted two layer of a porous external and a dense internal one. The reaction layer and surface roughness increased with increasing investment material temperature. Conclusion: In this work, The most suitable mold temperature in casting of pure titanium was $200^{\circ}C$.

In-situ Synthesis and Investment Casting of Titanium Matrix (TiC+TiB) Hybrid Composites (Ti기 (TiC+TiB) 하이브리드 복합재료 반응생성합성 및 정밀주조)

  • Sung, Si-Young;Park, Keun-Chang;Lee, Sang-Hwa;Kim, Young-Jig
    • Journal of Korea Foundry Society
    • /
    • v.24 no.3
    • /
    • pp.159-164
    • /
    • 2004
  • The aim of the present work is to investigate the possibility of in-situ synthesis and net-shape forming of the titanium matrix (TiC+TiB) hybrid composites using a casting route. From the scanning electron microscopy, electron probe micro-analyzer, X-ray diffraction and thermodynamic calculations, the spherical TiC and needle like TiB reinforced hybrid titanium matrix composites could be obtained in-situ by the conventional melting and casting route between titanium and $B_4C$. No melt-mold reaction occurred between the titanium matrix (TiC+TiB) hybrid composites and the SKK mold, since the mold is consisted with interstitial and substitutional metal-mold reaction products. Not only the sound in-situ synthesis but also the economic net-shape forming of the titanium matrix (TiC+TiB) hybrid composites could be possible by the conventional casting route.

THE EFFECTS OF SPURE AND INVENTS ON THE CASTING ACCURACY AND POROSITY OF TI-NI CASTINGS

  • Cho Lee-Ra;Yi Yang-Jin;Park Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.342-350
    • /
    • 2003
  • Statement of problem. Titanium-Nickel alloy might be used in various prosthetic restorations since it has a unique property such as super-elasticity and high fatigue resistance. However, little is known about the casting ability of this alloy. Purpose. This in vitro study compared the casting accuracy and the porosity made with different investments and various sprue designs to ascertain what casting condition would be better for the fabrication of Ti-Ni cast restorations. Material and methods. A total of 70 Ti-Ni alloy crowns were made and divided into 7 groups of 10 copings on a metal master die. For measuring the effect of the sprue numbers, two groups with one and two 8-gauge sprues were compared. Moreover, the results of the conventional sprue and the double thickness sprues were compared. Three investments were used; carbon free phosphate bonded investment, titanium investment and gypsum bonded investment. The cast restorations were evaluated at 48 points on the entire circumferential margin with a stereomicroscope measuring in micrometers. Each crown was radiographically examined for casting defects and porosity. Data on casting accuracy were analyzed using two-way and Post hoc Scheffe's comparison to determine whether significant differences existed at the 95% confidence level. Student-Newman-Keuls test were performed to identify significant differences in the number of voids. Results. The double sprueing group and double thickness group had significantly less marginal discrepancy than the single sprueing group (P<.05 and P<.01, respectively). The castings with phosphate bonded investment showed the least marginal discrepancy and the smoothest surface. The castings invested in the gypsum bonded investment had the greatest gaps in margin and the largest failure rate. The double sprueing group and phosphate bonded investment group had significantly smaller void numbers and smaller void size than the other groups. Conclusion. Within the limitations of this in vitro study, the casting accuracy of the groups using thicker, double sprue design and the phosphate bonded investment was significantly superior. Moreover, void number and size were less than other groups.

A Study on the Effect of Inclusions on the Fatigue Life of Titanium Investment Castings (티타늄 정밀주조품의 피로수명에 미치는 개재물의 영향에 관한 연구)

  • Park, Yong-Kuk;Ret, P.L.;Kim, Jin-Gon
    • Journal of Korea Foundry Society
    • /
    • v.26 no.2
    • /
    • pp.85-91
    • /
    • 2006
  • Inclusions in Ti investment castings are generally known to have detrimental effects on the performance of the castings. However, actual inclusions are infrequent and hard to be located. As a result, it is extremely difficult to obtain sufficient amount of fatigue test specimens of titanium investment castings having inclusions in the gage section. Thus, in-depth research of the adverse influence of inclusions is also hindered. To address this problem, a new casting methodology of specimens containing hard alpha inclusions was developed in this study. To guarantee successful introduction of an inclusion and casting, a carefully designed mold with 8 legs and a special tool were employed. After solidification, castings were cut, and X-ray radiography determined that the inclusions were successfully incorporated into the castings. The castings were further prepared to obtain multiple test specimens and they were fatigue-tested consecutively. Fractography analysis confirmed that fatigue cracks initiated at the hard alpha inclusion. In a nonlinear regression model, the fatigue life can be modeled as an exponential function with a negative exponent of the cross-sectional area of an inclusion. The fatigue life of Ti specimens containing inclusions is inversely proportional to the cross-sectional area of an inclusion.

Comparison of internal porosity of dental titanium castings with different casting machines (주조방식에 따른 티타늄 주조체의 내부결함 비교)

  • Lee, Kyung-Eun;Kim, Bu-Sob;Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.129-140
    • /
    • 2007
  • The purpose of this study was to evaluate the titanium castability (internal porosity) between pressure type casting machine & centrifugal casting machine with air-vent or not. Internal porosity is a well-known problem in dental titanium casting, resulting in inferior mechanical properties of dental restorations. To evaluate the castability, the square plate was chosen. 40 plate patterns($20{\times}20{\times}1.8mm$)were attached to funnel-shaped sprue. Then 20 plate patterns were attached air-vent. They were invested in titanium investment material and cast in a pressure type casting machine(20castings) and centrifugal casting machine(20castings). Each group were divided with air-vent(10castings) or not(10castings). The titanium castings were evaluated by radiographic photograph for the location of the internal porosities. The percentage porosity of each specimen was determined using standardized digital radiographs. The results were analyzed with analysis of variance and t-test for paired comparison between two groups.

  • PDF

Influence of the Mold Temperature on the Castability of CP Ti (주형온도가 CP Ti의 주조성에 미치는 영향)

  • Jung, Jong-Hyun;Joo, Kyu-Ji;Go, Eun-Kyoung
    • Journal of Technologic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.9-17
    • /
    • 2006
  • The purpose of this study was to evaluate the titanium castability with a spin type casting machine(TiCast, Super R, Selec, Osaka. Japan). We tested phosphate bonded investment "Rematitan$^{(R)}$Plus(Dentaurum, Inc., Pforzheim, Germany)"of mesh grid pattern and plate pattern. Four different mold temperatures(room temperature, 200$^{\circ}C$, 400$^{\circ}C$ and 600$^{\circ}C$) were prepared for the present study. In mesh grid pattern with spruing of $\varphi$0.88㎜ dimeter, when the mold temperature increased, high percentage of castability was gained. Mold temperature showed a highly significant(p<0.05) correlation on the castability, In plate pattern, the higher the mold temperature during casting, the greater the adhesive phenomenon between Ti surface and the investment.

  • PDF

Effects of Cooling Method Followed by Casting on the Interfacial and Mechanical Properties of Dental CP-Ti Casts (치과용 티타늄 주조체의 냉각방법이 표면반응층 및 기계적 특성에 미치는 영향)

  • Moon, Soo;Jung, Jun-Young;Kim, Ki-Ju;Lee, Jin-Hyung
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.375-380
    • /
    • 2003
  • In this study. we have intended to control the properties of surface reaction zone generated between pure titanium and oxide investment moulds. Commercially pure titanium was centrifugally casted and silica$.$alumina based phosphate bonded investment was used as the mould material. The effect of cooling methods after casting on the surface reaction zone and mechanical properties of casts were investigated. The resulting casts showed the multilayered surface reaction zone regardless of cooling method. Especially. water cooling method produced the titanium casts with thinner surface reaction zone. weaker strength. and higher elongation properties compared to air cooling. It can thus be known that the resulting casts had satisfactory mechanical properties as dental materials. From these results, the cooling rate dependence of interfacial and mechanical properties can be attributed to the diffusion of oxygen from casting environment, which control the reaction of titanium and mould.

THE EFFECT OF CASTING MACHINE AND INVESTMENT ON THE CASTABILITY OF TITANIUM (주입선 형태가 타이타늄 합금의 주조성에 미치는 영향)

  • Kim, Sang-Tae;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.522-533
    • /
    • 2007
  • Statement of problem: Despite of the recent development of the titanium casting system methods, the casting defects such as imperfect casting and internal porosity were frequently observed. Purpose: The purposes of this study were to compare and measure the castability, microhardness, and surface reaction between Grade 2 pure titanium and Ti-6Al-4V by casting these alloys from the different sprue design conditions. Material and methods: Depending on the sprue designs and titanium alloys, 42 ready-made wax patterns were used. By analyzing the remodeling of the cast, internal porosity, microhardness, and titanium surface layer of SEM, there were several results we observed. Results: 1. The measured castability of titanium were categorized in the ascending order: individual sprue group, runner bar group, and single group. This data are based on the statistically signigicant differences. 2. The castability of titanium has not showed the statistically significant differences among the alloys. However, CP-Ti groups were superior to Ti-6Al-4V groups by showing the noticeable castability. 3. The surface layers of the castings of all groups have showed $5{\mu}m$ titanium oxide layers irrespective of sprue designs and titanium alloys. Conclusion: From the above study results, by fabricating the restorations from the centrifugal casting machine direct sprue designs revealed better castability. As we increased the number of sprues in the wax pattern, it revealed better castability. The castability of pure titanium rather than that of Ti-6Al-4V was remarkable. To fabricate the complex forms of the restorations, further researches on the efficient sprue designs and titanium alloys must be made.

Analysis of castability in c.p.Ti according to casting conditions (주조조건에 따른 순티타늄의 주조성 분석)

  • Hwang, Seong-Sig;Kwon, Seog-Suk
    • Journal of Technologic Dentistry
    • /
    • v.29 no.1
    • /
    • pp.133-138
    • /
    • 2007
  • In this study, the castability and of commercially pure titanium(c.p.Ti) grade according to the casting condition which are the vacuum condition in casting machine and mold temperature of investment, was investigated. Argon-arc melt/centrifugal casting machine was used for casting the specimens. The microstructure and mechanical properties were evaluated by using optical microscope. The results were as follows; 1. It could make a sure that there's relatively not much defect of casting body of c.p.Ti according to the deference of air pressure. 2. It could make sure that it formed porosity on the surface inside of the casting body of c.p.Ti according to deferent temperature. and on excellent castability was below $200^{\circ}C$ 3. As the mold temperature of investment was increased, the lamellar structure of phase and coarse grains were shown, especially under 42MPa.

  • PDF