Browse > Article

THE EFFECT OF CASTING MACHINE AND INVESTMENT ON THE CASTABILITY OF TITANIUM  

Kim, Sang-Tae (Department of Dental Science, Graduate School, Chonnam National University)
Vang, Mong-Sook (Department of Dental Science, Graduate School, Chonnam National University)
Yang, Hong-So (Department of Dental Science, Graduate School, Chonnam National University)
Park, Sang-Won (Department of Dental Science, Graduate School, Chonnam National University)
Park, Ha-Ok (Department of Dental Science, Graduate School, Chonnam National University)
Lim, Hyun-Pil (Department of Dental Science, Graduate School, Chonnam National University)
Publication Information
The Journal of Korean Academy of Prosthodontics / v.45, no.4, 2007 , pp. 522-533 More about this Journal
Abstract
Statement of problem: Despite of the recent development of the titanium casting system methods, the casting defects such as imperfect casting and internal porosity were frequently observed. Purpose: The purposes of this study were to compare and measure the castability, microhardness, and surface reaction between Grade 2 pure titanium and Ti-6Al-4V by casting these alloys from the different sprue design conditions. Material and methods: Depending on the sprue designs and titanium alloys, 42 ready-made wax patterns were used. By analyzing the remodeling of the cast, internal porosity, microhardness, and titanium surface layer of SEM, there were several results we observed. Results: 1. The measured castability of titanium were categorized in the ascending order: individual sprue group, runner bar group, and single group. This data are based on the statistically signigicant differences. 2. The castability of titanium has not showed the statistically significant differences among the alloys. However, CP-Ti groups were superior to Ti-6Al-4V groups by showing the noticeable castability. 3. The surface layers of the castings of all groups have showed $5{\mu}m$ titanium oxide layers irrespective of sprue designs and titanium alloys. Conclusion: From the above study results, by fabricating the restorations from the centrifugal casting machine direct sprue designs revealed better castability. As we increased the number of sprues in the wax pattern, it revealed better castability. The castability of pure titanium rather than that of Ti-6Al-4V was remarkable. To fabricate the complex forms of the restorations, further researches on the efficient sprue designs and titanium alloys must be made.
Keywords
Castability; Titanium; sprue design;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Watanabe K. Okawa S. Miyakawa O. Nakano S. Determination of titanium flow by the tracer element molten method in the dental precisopn casting. 2. Relationship between the titanium flow in plate molds and the casting defects. J Dent Mater 1991:10:77-96
2 Chan D, Guillory V, Blackman R, Chung KH. The effects of sprue designs on the roughness and porosity of porosity of titanium castings. J Prosthet Dent 1997:78:400-4   DOI   ScienceOn
3 Syverud M. Okabe T. Casting of Ti-6Al-4V alloy compared e Ti in with puran Ar-arc casting machine. Eur J Oral Sci 1995:103: 327-330   DOI   ScienceOn
4 Ryge G, Kozak SF, Firahurst CW. Porosity dental gold castings. J Am Dent Assoc 1957: 54 :46-54
5 Brockhurst PJ, McLaverty VG, Kasloff Z. A castability standard for alloys used in restorative dentistry. Oper Dent 1983:8:130-9   PUBMED
6 Bridgeman JT, Marker VA, Hummel SK. Comparison of titanium and cobalt-chromium removable partial dentures. J Am Dent Assoc 1997:78:187-193
7 Park JK, Jeong CM, Jeon YC. The effect of sprue design on the marginal reproducibility of cast titanium crowns. J Kor Acad Prothodont 2004:40: 352-363
8 Watanabe I, Woldu H, Okabe T. Effect of casting method on castability of titanium and dental alloys. J Mater Sci 2000;11:547-53
9 Miyazaki T. Casting of titanium: mold materials Proceedings Transaction of second international congress on dental materilas. 1995:107:1123-7
10 Preston JD, Berger R. Some laboratory variables affecting cerarno-rnetal alloys. Dent Clin North Am 1977:21:717-28   PUBMED
11 Chai TI, Stein RS. Porosity and accuracy of multiple-unit titanium castings. J Prosthet Dent 1995:73:534-41   DOI   ScienceOn
12 Mori T, Jean Louis M, Toyaga T. The effect of investment type on the fit of cast titanium crowns. Aust Dent J 1994:39:348-352   DOI   ScienceOn
13 Eugene PL, Peter M. Titanium and titanium alloys as dental materials. Int Dent J 1993:43:245-53
14 Chai TI, Stein RS. Porosity and accuracy of multiple-unit titanium castings. J Prosthet Dent 1995:73:534-41   DOI   ScienceOn
15 Reclaru L, Meyer JM. Study of corrosion between a titanium implant and dental alloy. J Dent 1994:22:159-68   DOI   ScienceOn
16 Chan DC, Blackman R, Kaiser DA, Chung K. The effect of sprue design on the marginal accuracy of titanium castings. J Oral Rehabil 1998:25:424-9   DOI   ScienceOn
17 Flemmings MC. Solidification processing. New york: McGraw Hill Inc. 1974:219-224
18 Her H, Syverud M, Waari M, Jorgensen RB. Casting of dental titanium crowns: surface reations and dimensional fit. In: Proceedings of the 1990 International Conference on titanium. Products and Applications. Vol.II. Dayton. Ohio: Titanium Development Association 1990: 612-21
19 Al Mesmar HS. Morgano SM. Mark LE. Investigation of the effect of three sprue designs on the porosity and the completeness of titanium cast removable partial denture frameworks. J Prosthet Dent 1999:82:15-21   DOI   ScienceOn
20 Watanabe I. Watkins JH, Nakagima H, Atsuta M, Okabe T. Effect of pressure difference on the quality of titanium casting. J Dent Res 1997:3:773-9
21 Sunnerkrantz PA, Syverud M, Her H. Effect of casting atmosphere on the quality of 'Ti-crowns. Scand J Dent Res 1990:98:268-72   PUBMED
22 Chan D, Gullilory V, Blackmann R, Chung KH. The effect of sprue design on the roughness and porosity of titanium castings. J Prosthet Dent 1997:78:400-4   DOI   ScienceOn
23 Kim KN. Dental casting alloy. First edition, KoonjaPublishing Co., 1992;45-60
24 Wang RR, Boyle AM. A simple method for inspection of porosity in titanium castings. J Prosthet Dent 1993:70:275-6   DOI   ScienceOn
25 Mori T. Togaya T. Yabugami M. Jean-Louis M. Titanium for removable dentures. J Oral Rehabilit 1997:24:338-341   DOI   ScienceOn
26 Watanabe K, Okawa S, Miyakawa O, Nakano S. Molten titanium flow in a mesh cavity by the flow visualization technique. Dent Mater 1991:10:128-137   DOI   ScienceOn
27 Parr GR, Gardner LK, Toth RW. Titanium ; the mystery metal of implant dentistry Dental materials aspects. J Prosthet Dent 1985:54:410-14   DOI   ScienceOn
28 Miyazaki T. Recent progress in titanium dental casting technologies and current problems for a clinical application. Quintessence 1992:11:171-182
29 Her H, Syverud M, Waarli M. Mold filling and porosity in casting of titanium. J Dent Res 1993:9:15-8
30 Watari F. High temperature reactivity between titanium and refractory oxides in dental casting procedure. Fundamental study on refractoriness of investments and ceramo metal bonding by analytical SEM and oxide single crystals. J Dent Mater 1989:8:83-96
31 Miyazaki T. Casting of titanium and its alloys: Metal surface and ceramics Proceeding of international Symposiumon titanium in dentistry 1995:3:120-133
32 Watanabe K. Okawa S. Miyakawa O. Nakano S. Honma H. Shiokawa N. Kobayashi M. Relationship between titanium flow and casting contamination caused by mold materials. J Dent Mater 1992:11:662-671
33 Mori T, Jean-Louis M, Yabugami M, Togaya T. The effect of investment type on the fit of cast titanium crowns. Aust Dent J 1994:39:384-52
34 Christer B. Maud B. The castability of unalloyed titanium in three different casting machines. Swed Dent J 1992:16:109-113   PUBMED
35 Syverud M, Her H. Mold filling of Ti castings using investments with different gas permeability. Dent Mater 1995:11:14-8   DOI   ScienceOn
36 Vidovic Y, Chung HG, Mroi T. Enhancement of a titanium denture frame model: mold temperature and spruing factors. Dent Mater J 1995:14:256-62   DOI   PUBMED   ScienceOn
37 Kusakari H, Ozaki Y, Hoshino H. Cast titanium crown-for a better fitness and less porosity [in Janpanes]. Quintessence Dent Technol 1998:23:17-23
38 Blackman R, Barghi N, Tran C. Dimensional changes in casting titanium removable partial denture frameworks. J Prosthet Dent 1991:65:309-315   DOI   ScienceOn
39 Watanabe K. Okawa S. Miyakawa O. Nakano S. Determination of titanium flow by the tracer element molten method in the dental precisopn casting. 1. The principle of flow visualization and application to sample castings. J Dent Mater 1990:9:623-632