• 제목/요약/키워드: Titanium cap

검색결과 6건 처리시간 0.027초

RP titanium cap과 rhBMP-2를 이용하여 형성된 신생골의 미세전산화단층촬영을 이용한 평가 (Evaluation of bone formation by recombinant human BMP-2 and rapid prototype titanium cap in rabbit calvaria using micro computed tomography)

  • 한만승;정승곤;김방신;양지웅;국민석;박홍주;유선열;오희균
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권6호
    • /
    • pp.466-472
    • /
    • 2010
  • Introduction: This study examined the effect of recombinant human bone morphogenetic protein (rhBMP)-2 and $\beta$-tricalcium phosphate ($\beta$-TCP) on new bone formation in a rabbit calvarium using a rapid prototype titanium cap (RP Ti cap). Materials and Methods: Eight New Zealand white rabbits were used in this study. Hemispherical RP Ti caps (10 mm in diameter) were implanted subperiosteally on the rabbit calvaria. $\beta$-TCP was filled in the RP Ti cap in the control group, and rhBMP-2 soaked $\beta$-TCP was used in experimental group. The rabbits were sacrificed 2 and 4 weeks after the operation. The volume and pattern of newly formed bone was analyzed by micro computed tomography (CT). Results: Macroscopically, there were no abnormal findings in any of the animals. The micro CT images revealed new bone from the calvaria that expanded gradually toward the top of the titanium cap, particularly along the inner surface of the titanium cap in the experimental group at 4 weeks after grafting. There was no significant difference in new bone volume ratio between the control and experimental groups at 2 weeks after grafting. There was a statistically significant difference in the new bone volume ratio between the experimental ($14.1{\pm}1.8\;%$) and control ($7.2{\pm}1.5\;%$) groups at 4 weeks after grafting (P<0.01). Conclusion: The RP Ti cap can effectively guide new bone formation and rhBMP-2 can induce the new bone formation.

가토의 두개골에서 Pore의 유무에 따른 티타늄 반구에서의 골형성 능 (The Bone Formation Potency on the Titanium Cap According to the Pore on the Rabbit Calvarium)

  • 박정표;오철중;정승곤;박홍주;오희균;유선열;국민석
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제35권1호
    • /
    • pp.18-24
    • /
    • 2013
  • Purpose: This study is performed to determine the effects of titanium cap with various sizes of pores on bone formation during guided bone regeneration (GBR). Methods: Calvaria from 10 adult male rabbits were chosen as the recipient sites. A trephine bur with a diameter of 10 mm was used to form one round groove on each side of sagittal suture of the cranium, and a round bur with a diameter of 1.5 mm was used to form 6 small holes on the inner circles of round grooves to induce bleeding. In the control group, bone graft was not conducted, and closed titanium cap was fixed in the round groove. Bone graft was not performed in groups 1 and 2, but fixed on titanium caps with 0.2 mm, and 0.5 mm sized pores, respectively. For groups 3, 4, and 5, a synthetic bone graft material (${\beta}$-tricalcium phosphate, Cerasorb$^{(R)}$, Germany) was transplanted, and titanium caps without pore, with 0.2 mm and 0.5 mm sized pore were fixed, respectively. The animals were sacrificed 4 weeks after, and clinical, radiographical, and histomorphometrical evaluation of bone regeneration was performed. Results: In all groups, there were no clinical signs of infection, inflammation or wound dehiscence. Radiographic evaluation revealed well-defined semi-circular radiopacity inside the titanium cap of groups 3, 4, and 5. Histologically, the inner surface of the hemisphere was evenly lined with newly formed bone tissue, as well as grafted bone material in the group 3. In groups 4 and 5, the insertion of connective tissue was observed along the inner surface. However, the overall surface area between the grafts with different holes yielded no statistical significance in the histomorphometrical evaluation. Conclusion: Although the total area of newly formed bone showed no significant difference, excellent bone formation tendency was observed histologically when closed caps were used with bone graft was accompanied.

가토의 두개골에서 티타늄 반구를 이용한 다양한 onlay bone graft시 골형성 능력 (THE EFFECT OF NEW BONE FORMATION OF ONLAY BONE GRAFT USING VARIOUS GRAFT MATERIALS WITH A TITANIUM CAP ON THE RABBIT CALVARIUM)

  • 박영준;최근호;장정록;정승곤;한만승;유민기;국민석;박홍주;유선열;오희균
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권6호
    • /
    • pp.469-477
    • /
    • 2009
  • 육안적 검사결과 실험군과 대조군 모두에서 특별한 염증 소견이나 창상 이개 없이 반원 모양의 골형성이 관찰되었다. 조직학적으로 3주째에 대조군, 실험 1군, 실험2군, 실험 3군 모두 이식골 주위 및 티타늄 반구 내면을 따라 신생 골형성이 관찰되었다. 조직학적으로 6주째에 모든 군에서 3주째에 비하여 신생골 면적의 증가 및 성숙 소견이 관찰되었고, 실험2군에서는 부분적으로 이식골이 흡수되면서 신생골이 형성되는 것이 관찰된 반면, 실험 3군에서는 이식골의 흡수 소견이 관찰되지 않았다. 조직형태계측학적으로 3주, 6주 모두 자가골에서 가장 많은 신생골 형성이 나타났고, 신생골 면적 비교시 자가골, 이종골, 합성골 순으로 크게 나타났고, 각 군간의 통계학적으로 유의한 차이는 없었다(p>0.05). 본 연구결과 골유도 재생술시 골형성 능력은 자가골이 가장 좋지만, 자가골 채취가 불가능할 경우, 적절한 차폐막을 사용한 합성골과 이종골 복합 이식방식도 좋은 대체제가 될 것으로 생각된다.

Maxillary molar derotation and distalization by using a nickel-titanium wire fabricated on a setup model

  • Jung, Jong Moon;Wi, Young Joo;Koo, Hyun Mo;Kim, Min Ji;Chun, Youn Sic
    • 대한치과교정학회지
    • /
    • 제47권4호
    • /
    • pp.268-274
    • /
    • 2017
  • The purpose of this article is to introduce a simple appliance that uses a setup model and a nickel-titanium (Ni-Ti) wire for correcting the mesial rotation and drift of the permanent maxillary first molar. The technique involves bonding a Ni-Ti wire to the proper position of the target tooth on a setup model, followed by the fabrication of the transfer cap for indirect bonding and its transfer to the patient's teeth. This appliance causes less discomfort and provides better oral hygiene for the patients than do conventional appliances such as the bracket, pendulum, and distal jet. The treatment time is also shorter with the new appliance than with full-fixed appliances. Moreover, the applicability of the new appliance can be expanded to many cases by using screws or splinting with adjacent teeth to improve anchorage.

3중 접합 공정에 의한 MEMS 공진기의 웨이퍼레벨 진공 패키징 (Wafer-level Vacuum Packaging of a MEMS Resonator using the Three-layer Bonding Technique)

  • 양충모;김희연;박종철;나예은;김태현;노길선;심갑섭;김기훈
    • 센서학회지
    • /
    • 제29권5호
    • /
    • pp.354-359
    • /
    • 2020
  • The high vacuum hermetic sealing technique ensures excellent performance of MEMS resonators. For the high vacuum hermetic sealing, the customization of anodic bonding equipment was conducted for the glass/Si/glass triple-stack anodic bonding process. Figure 1 presents the schematic of the MEMS resonator with triple-stack high-vacuum anodic bonding. The anodic bonding process for vacuum sealing was performed with the chamber pressure lower than 5 × 10-6 mbar, the piston pressure of 5 kN, and the applied voltage was 1 kV. The process temperature during anodic bonding was 400 ℃. To maintain the vacuum condition of the glass cavity, a getter material, such as a titanium thin film, was deposited. The getter materials was active at the 400 ℃ during the anodic bonding process. To read out the electrical signals from the Si resonator, a vertical feed-through was applied by using through glass via (TGV) which is formed by sandblasting technique of cap glass wafer. The aluminum electrodes was conformally deposited on the via-hole structure of cap glass. The TGV process provides reliable electrical interconnection between Si resonator and aluminum electrodes on the cap glass without leakage or electrical disconnection through the TGV. The fabricated MEMS resonator with proposed vacuum packaging using three-layer anodic bonding process has resonance frequency and quality factor of about 16 kHz and more than 40,000, respectively.

In vitro evaluation of fracture strength of zirconia restoration veneered with various ceramic materials

  • Choi, Yu-Sung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권3호
    • /
    • pp.162-169
    • /
    • 2012
  • PURPOSE. Fracture of the veneering material of zirconia restorations frequently occurs in clinical situations. The purpose of this in vitro study was to compare the fracture strengths of zirconia crowns veneered with various ceramic materials by various techniques. MATERIALS AND METHODS. A 1.2 mm, $360^{\circ}$ chamfer preparation and occlusal reduction of 2 mm were performed on a first mandibular molar, and 45 model dies were fabricated in a titanium alloy by CAD/CAM system. Forty-five zirconia copings were fabricated and divided into three groups. In the first group (LT) zirconia copings were veneered with feldspathic porcelain by the layering technique. In the second group (HT) the glass ceramic was heat-pressed on the zirconia coping, and for the third group (ST) a CAD/CAM-fabricated high-strength anatomically shaped veneering cap was sintered onto the zirconia coping. All crowns were cemented onto their titanium dies with Rely $X^{TM}$ Unicem (3M ESPE) and loaded with a universal testing machine (Instron 5583) until failure. The mean fracture values were compared by an one-way ANOVA and a multiple comparison post-hoc test (${\alpha}$= 0.05). Scanning electron microscope was used to investigate the fractured interface. RESULTS. Mean fracture load and standard deviation was $4263.8{\pm}1110.8$ N for Group LT, $5070.8{\pm}1016.4$ for Group HT and $6242.0{\pm}1759.5$ N for Group ST. The values of Group ST were significantly higher than those of the other groups. CONCLUSION. Zirconia crowns veneered with CAD/CAM generated glass ceramics by the sintering technique are superior to those veneered with feldspathic porcelain by the layering technique or veneered with glass ceramics by the heat-pressing technique in terms of fracture strength.