• Title/Summary/Keyword: Tissue attenuation

Search Result 148, Processing Time 0.028 seconds

A Study on the X-Ray Imaging using Dusl Energy Method (이중에너지 방법을 이용한 X선 영상법에 관한 연구)

  • 신동익;김종효
    • Journal of Biomedical Engineering Research
    • /
    • v.9 no.2
    • /
    • pp.185-194
    • /
    • 1988
  • The dual-energy technique win used to separate the bone-only and tissue-only images from the conventional chest images. The equivalent thickness of the basic materials are estimated from low and high energy images of a given complex materials using the attenuation coefficient of ma serial componens. We showed that the image quality of dual-energy imaging method can be influenced by the ponlinearity and noise components of system and spectrum distributions The quantitative analysis of Calcium component was performed by dual-energy technique and it is shown that the concentration of the Calcium could be accurately estimated within 5% error range.

  • PDF

The Measurement of Ultrasonic Velocity in Multilayered Medium by Dip Points Analysis from Reflected Echo Spectrum (반대파 스펙트럼의 극소점 해석을 통한 다층매질에서의 음속 측정법)

  • 김시환;최종수
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.4
    • /
    • pp.16-23
    • /
    • 1985
  • In case of tissue characterization from ultrasonic echo signal, it is difficult to evaluate an absolute physical quantity because of redundancy in the echo signal. For it, in this paper a possibility of characterization of ultrasonic velocity distribution in multilayered medium using dip points analysis method from the reflected echo spectrum is discussed. To prove the possibility of this method, effect of interference phenomenon, impedance difference, attenuation, and thickness is discussed by computer simulation, and then the results confirm the effectiveness. And results of simple experiment are presented.

  • PDF

Analysis in Measurements of Gastric Emptying Time (위 배출시간 측정의 분석방범에 대한 연구)

  • Lee, Choon-Ho;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.35-38
    • /
    • 1997
  • Scintigraphic measurement of gastric emptying time has been reported to be influenced by the variation in depth of radionuclide within the stomach. This study was designed to clarify whether a part of the variability in gastric emptying could be ascribed to a relationship between anterior image, the total anteroposterior Image and the tissue attenuation correction(geometric mean). A dual-head scintillation camera(ADAC, USA) was used to investigate effect of such changes. We were performed 16 normal subject gastric emptying studies with $^{99m}TC$ labelled scramble egg, milk and solid meal(610 Kcal, 300 g) The results are as follows; On anterior Image, $T_{1/2}$ emptying time was delayed by 5 min, 6.5%(range $3{\sim}18\;min,\;5{\sim}31.4%$) compared with the geometric mean. But there was no different gastric emptying time between the total anteroposterior image and geometric mean. Therefore, if will be useful to use the method of geometric mean or the total anteroposterior image to evaluate the gastric emptying time accurately.

  • PDF

Radiological Findings of Pleural and Mediastinal Diseases (흉막 및 종격동 질환의 방사선학적 소견)

  • Choi, Yo Won
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.6
    • /
    • pp.543-553
    • /
    • 2005
  • Radiological analysis of chest lesions detected on chest radiographs or CT scans begins with their classification into parenchymal, pleural, or extrapleural lesions according to their presumed origin. The mediastinum is divided anatomically into the anterior, middle, and posterior mediastinal compartments, and localizing a mediastinal mass to one of these divisions can facilitate their differential diagnosis. A differential diagnosis of a mediastinal mass is usually based on a number of findings, including its location; the structure from which it is arising; whether it is single, multifocal (involving several different areas or lymph node groups), or diffuse; its size and shape; its attenuation (fatty, fluid, soft-tissue, or a combination of these); the presence of calcification along with its characteristics and amount; and its opacification following the administration of contrast agents.

Basic Physical Principles and Clinical Applications of Computed Tomography

  • Jung, Haijo
    • Progress in Medical Physics
    • /
    • v.32 no.1
    • /
    • pp.1-17
    • /
    • 2021
  • The evolution of X-ray computed tomography (CT) has been based on the discovery of X-rays, the inception of the Radon transform, and the development of X-ray digital data acquisition systems and computer technology. Unlike conventional X-ray imaging (general radiography), CT reconstructs cross-sectional anatomical images of the internal structures according to X-ray attenuation coefficients (approximate tissue density) for almost every region in the body. This article reviews the essential physical principles and technical aspects of the CT scanner, including several notable evolutions in CT technology that resulted in the emergence of helical, multidetector, cone beam, portable, dual-energy, and phase-contrast CT, in integrated imaging modalities, such as positron-emission-tomography-CT and single-photon-emission-computed-tomography-CT, and in clinical applications, including image acquisition parameters, CT angiography, image adjustment, versatile image visualizations, volumetric/surface rendering on a computer workstation, radiation treatment planning, and target localization in radiotherapy. The understanding of CT characteristics will provide more effective and accurate patient care in the fields of diagnostics and radiotherapy, and can lead to the improvement of image quality and the optimization of exposure doses.

Fundamental and plane wave solution in non-local bio-thermoelasticity diffusion theory

  • Kumar, Rajneesh;Ghangas, Suniti;Vashishth, Anil K.
    • Coupled systems mechanics
    • /
    • v.10 no.1
    • /
    • pp.21-38
    • /
    • 2021
  • This work is an attempt to design a dynamic model for a non local bio-thermoelastic medium with diffusion. The system of governing equations are formulated in terms of displacement vector field, chemical potential and the tissue temperature in the context of non local dual phase lag (NL DPL) theories of heat conduction and mass diffusion. Based on this considered model, we study the fundamental solution and propagation of plane harmonic waves in tissues. In order to analyze the behavior of the NL DPL model, we construct basic theorem in the terms of elementary function which determine the existence of three longitudinal and one transverse wave. The effects of various parameters on the characteristics of waves i.e., phase velocity and attenuation coefficients are elaborated by plotting various figures of physical quantities in the later part of the paper.

Incidental finding of metastatic malignancy involving the sphenoid sinus on a cone-beam computed tomographic scan: A case report

  • Amintavakoli, Niloufar
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.87-90
    • /
    • 2021
  • The increased use of cone-beam computed tomographic (CBCT) scans has made it increasingly necessary to evaluate incidental findings on CBCT scans. This report describes the case of a 66-year-old female patient who presented to the Department of Oral and Maxillofacial Pathology, Radiology and Medicine at the College of Dentistry of the author's institution and underwent a CBCT scan for maxillary alveolar process implant planning. Upon evaluation of the CBCT scan, a radiopaque (soft tissue attenuation) mass in the left superior aspect of the nasal cavity and left locule of the sphenoid sinus with opacification of the left locule of the sphenoid sinus was incidentally noted. These radiographic findings were suggestive of a space-occupying mass with a high possibility of malignancy. A further medical evaluation confirmed renal cell cancer metastasis to the sphenoid sinus. This study shows the significance of reviewing the entire CBCT scan for incidental findings.

Evaluation of Corrected Dose with Inhomogeneous Tissue by using CT Image (CT 영상을 이용한 불균질 조직의 선량보정 평가)

  • Kim, Gha-Jung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.75-80
    • /
    • 2006
  • Purpose: In radiation therapy, precise calculation of dose toward malignant tumors or normal tissue would be a critical factor in determining whether the treatment would be successful. The Radiation Treatment Planning (RTP) system is one of most effective methods to make it effective to the correction of dose due to CT number through converting linear attenuation coefficient to density of the inhomogeneous tissue by means of CT based reconstruction. Materials and Methods: In this study, we carried out the measurement of CT number and calculation of mass density by using RTP system and the homemade inhomogeneous tissue Phantom and the values were obtained with reference to water. Moreover, we intended to investigate the effectiveness and accuracy for the correction of inhomogeneous tissue by the CT number through comparing the measured dose (nC) and calculated dose (Percentage Depth Dose, PDD) used CT image during radiation exposure with RTP. Results: The difference in mass density between the calculated tissue equivalent material and the true value was ranged from $0.005g/cm^3\;to\;0.069g/cm^3$. A relative error between PDD of RTP and calculated dose obtained by radiation therapy of machine ranged from -2.8 to +1.06%(effective range within 3%). Conclusion: In conclusion, we confirmed the effectiveness of correction for the inhomogeneous tissues through CT images. These results would be one of good information on the basic outline of Quality Assurance (QA) in RTP system.

  • PDF

Evaluation of Error Factors in Quantitative Analysis of Lymphoscintigraphy (Lymphoscintigraphy의 정량분석 시 오류 요인에 관한 평가)

  • Yeon, Joon-Ho;Kim, Soo-Yung;Choi, Sung-Ook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.76-82
    • /
    • 2011
  • Purpose: Lymphoscintigraphy is absolutely being used standard examination in lymphatic diagnosis, evaluation after treatment, and it is useful for lymphedema to plan therapy. In case of lymphoscintigraphy of lower-extremity lymphedema, it had an effect on results if patients had not pose same position on the examination of 1 min, 1 hour and 2 hours after injection. So we'll study the methods to improve confidence with minimized quantitative analysis errors by influence factors. Materials and Methods: Being used the Infinia of GE Co. we injected $^{99m}Tc$-phytate 37 MBq (1.0 mCi) 4 sylinges into 40 people's feet hypodermically from June to August 2010 in Samsung Medical Center. After we acquired images of fixed and unfixed condition, we confirmed the count values change by attenuation of soft tissue and bone according to different feet position. And we estimated 5 times increasing 2 cm of distance between $^{99m}Tc$ point source and detector each time to check counts difference according to distance change by different feet position. Finally, we compared 1 and 6 min lymphoscintigraphy images with same position to check the effect of quantitative analysis results owing to difference of amounts of movement of the $^{99m}Tc$-phytate in the lymphatic duct. Results: Percentage difference regarding error values showed minimum 2.7% and maximum 25.8% when comparing fixed and unfixed feet position of lymphoscintigraphy examination at 1 min after injection. And count values according to distance were 173,661 (2 cm), 172,095 (4 cm), 170,996 (6 cm), 167,677 (8 cm), 169,208 counts (10 cm) which distance was increased interval of 2 cm and basal value was mean 176,587 counts, and percentage difference values were not over 2.5% such as 1.27, 1.79, 2.04, 2.42, 2.35%. Also, Assessment results about amounts of movement in lymphatic duct within 6 min until scanning after injection showed minimum 0.15%, and maximum 2.3% which were amounts of movement. We can recognize that error values represent over 20% due to only attenuation of soft tissue and bone except for distance difference (2.42%) and amounts of movement in lymphatic duct (2.3%). Conclusion: It was show that if same patients posed different feet position on the examination of 1 min, 1 hour and 2 hours after injection in the lymphoscintigraphy which is evaluating lymphatic flow of patients with lymphedema and analyzing amount of intake by lymphatic system, maximum error value represented 25.8% due to attenuation of soft tissue and bone, and PASW (Predictive Analytics Software) showed that fixed and unfixed feet position was different each other. And difference of distance between detector and feet and change of count values by difference of examination beginning time after injection influence on quantitative analysis results partially. Therefore, we'll make an effort to fix feet position and make the most of fixing board in lymphoscintigraphy with quantitative analysis.

  • PDF

Medical Imaging of Well-differentiated Liposarcoma Arising from the Falciform Fat in a Dog (개에서 겸상인대에서 유래된 분화지방육종의 영상의학증례)

  • Jung, Dong-In;Kim, Jae-Hwan;Ha, Ji-Young;Park, Ki-Tae;Yeon, Seong-Chan;Lee, Hee-Chun
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.186-189
    • /
    • 2012
  • A 7-year-old castrated male Cocker spaniel dog was referred to Gyeongsang National University Veterinary Medical Teaching Hospital with a severe abdominal distension. A huge, inhomogeneous fat opacity mass was identified on the abdomen radiographic survey. From the abdominal ultrasonographic examination, the mass was found to have irregular marginated hyperechoic capsule with cellular hypoechoic fluids inside. On the computed tomography, an encapsulated inhomogeneous mass was identified with fat attenuation peripheral and soft tissue attenuation inside. The origin of the mass was confirmed as falciform fat by surgical excision. The resected mass appeared to be a firm reddish-brown color with a smooth surface. The histopathological appearance was a well-differentiated liporsarcoma. The patient has no recurrent signs 1 month after surgery.