• Title/Summary/Keyword: Time-alignment

Search Result 715, Processing Time 0.03 seconds

Turbine Alignment (II): Computer Program Development (발전설비의 터빈 축정렬 (II) : 자동화를 위한 전산 프로그램 개발)

  • Hwang, Cheol-Ho;Kim, Jeong-Tae;Jun, Oh-Sung;Lee, Hyun;Lee, Byung-Jun
    • Journal of KSNVE
    • /
    • v.4 no.1
    • /
    • pp.33-42
    • /
    • 1994
  • When a vibration is generated due to the misalignment, the reduction of the vibration level is not attainable unless a correct shaft alignment is conducted. In a turbine system, an alignment procedure requires quite a lot amount of expense and time. To reduce this effort, an algorithm of the turbine alignment is developed to be used in the computer program. The program consists of five parts : input, calculation, display of the results, file management, and printer output. In the input part, users must provide the data on the turbine number, the reference value of the alignment, and the number of the feet of the generator. In calculation, the moving distance of the bearing and the necessary amount of the shims are calculated. In the display and the output parts, the calculated results are displayed and calculated. In the display and the output parts, the calculated results are displayed and printed. Then, by using the file management, results and procedures conducted are saved in the floppy diskette or in the hard disk. The developed program can be run in IBM PC compatible with more than 640 KB of main memory with the operating system of MS-DOS v 3.3 or higher. It is developed for novice users with no experience or specialty in this field. The program is not only useful in the power plant application, but also helpful for recording of the alignment procedures.

  • PDF

A New Orthodontic Appliance for Rapid Anterior Alignment in Adults; Mini-Tube Appliance (MTA) (성인 전치부 부분교정을 위한 새로운 교정장치 MTA의 이용)

  • Hwang, Hyeon-Shik;Jeon, Hyun-Ran;Kim, Seok-Pil;Kim, Wang-Sik;Lee, Gye-Hyeong
    • The Journal of the Korean dental association
    • /
    • v.49 no.7
    • /
    • pp.398-409
    • /
    • 2011
  • With an increase of public's perception on "minimally invasive dentistry", more patients are demanding orthodontic alignment of anterior teeth rather than restorative treatment which is more invasive. One draw back of orthodontic alignment has been that it takes long time. To overcome this limitation, a new orthodontic device named Mini-Tube Appliance (MTA), have been developed. With the combined use of light NiTi wire and inter-proximal stripping, rapid anterior alignment can be obtained efficiently. This article presents the use of MTA for rapid alignment of anterior teeth and its clinical guidelines with typical case samples.

Gene Sequences Clustering for the Prediction of Functional Domain (기능 도메인 예측을 위한 유전자 서열 클러스터링)

  • Han Sang-Il;Lee Sung-Gun;Hou Bo-Kyeng;Byun Yoon-Sup;Hwang Kyu-Suk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.10
    • /
    • pp.1044-1049
    • /
    • 2006
  • Multiple sequence alignment is a method to compare two or more DNA or protein sequences. Most of multiple sequence alignment tools rely on pairwise alignment and Smith-Waterman algorithm to generate an alignment hierarchy. Therefore, in the existing multiple alignment method as the number of sequences increases, the runtime increases exponentially. In order to remedy this problem, we adopted a parallel processing suffix tree algorithm that is able to search for common subsequences at one time without pairwise alignment. Also, the cross-matching subsequences triggering inexact-matching among the searched common subsequences might be produced. So, the cross-matching masking process was suggested in this paper. To identify the function of the clusters generated by suffix tree clustering, BLAST and CDD (Conserved Domain Database)search were combined with a clustering tool. Our clustering and annotating tool consists of constructing suffix tree, overlapping common subsequences, clustering gene sequences and annotating gene clusters by BLAST and CDD search. The system was successfully evaluated with 36 gene sequences in the pentose phosphate pathway, clustering 10 clusters, finding out representative common subsequences, and finally identifying functional domains by searching CDD database.

Effect of Breathing Exercises via Joint mobilization on the Lung Function and Spinal Alignment of Straight-necked Women

  • Kong, Byung-Sun;Jeong, Beom-Cheol;Yoo, Kyung-Tae
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.15 no.4
    • /
    • pp.55-65
    • /
    • 2020
  • PURPOSE: This study examined the effects of breathing exercises via joint mobilization on the lung function and spinal alignment of 30 straight-necked women in their 20 s and 30 s. METHODS: The participants were divided into two groups: an experimental group who performed breathing exercises via joint mobilization, and a control group who performed general stretching exercises. The differences between the two groups were measured and compared at three points in time: during the pre-examination, after four weeks of intervention, and after a four-week maintenance period. The changes in each group were measured before and after the intervention and after a one-month maintenance period and compared. For data analysis, the SPSS 22 was used to obtain the mean and standard deviation with a significance level of α = .05. RESULTS: Eight weeks of breathing exercises via joint mobilization and general stretching exercises positively impacted the lung function and spinal alignment in straight-necked patients. In particular, the experimental group showed more significant differences in spinal alignment after four weeks period of intervention and four weeks of maintenance. CONCLUSION: Breathing exercises via joint mobilization can be considered an effective intervention that can improve the respiratory volume and spinal alignment for patients with straight necks.

Multiple Sequence Aligmnent Genetic Algorithm (진화 알고리즘을 사용한 복수 염기서열 정렬)

  • Kim, Jin;Song, Min-Dong;Choi, Hong-Sik;Chang, Yeon-Ah
    • Korean Journal of Microbiology
    • /
    • v.35 no.2
    • /
    • pp.115-120
    • /
    • 1999
  • Multiple Sequence Alignment of DNA and protem sequences is a imnport'mt tool in the study of molecular evolution, gene regulation. and prolein suucture-function relationships. Progressive pairwise alignment method generates multiple sequence alignment fast but not necessarily with optimal costs. Dynamic programming generates multiple sequence alig~~menl with optimal costs in most cases but long execution time. In this paper. we suggest genetlc algorithm lo improve the multiple sequence alignment generated from the cnlent methods, describe the design of the genetic algorithm, and compare the multiple sequence alignments from 0111 method and current methods.

  • PDF

Best-Effort Interference Alignment for K Users Quasi-Static MIMO Interference Channels

  • Jiang, Lijing;Song, Rongfang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.6
    • /
    • pp.2859-2872
    • /
    • 2019
  • Interference alignment (IA) has been a powerful approach to achieve the maximum degree of freedom (DoF) for K users multiple-input-multiple-output (MIMO) interference channels. However, due to the feasibility constraint, aligning all the interference signals at each receiver is impractical for large K without symbol extension. In this paper, we propose two best-effort interference alignment (BEIA) schemes that the network selects the maximum number of interfering transmitters to align their signals given the feasibility conditions when each transmitter-receiver pair has a constant number of data streams. Besides, in case of not all interfering signals aligned at each receiver, an upper bound of the average throughput is derived. Simulation results show that the proposed schemes have superiority over the traditional methods, such as time division multiple access (TDMA) and cluster IA(CIA), in low and moderate signal-to-noise ratio (SNR) region in terms of average user throughput. In addition, the proposed max-min relative interference distance alignment scheme outperforms the proposed scheme of equal interfering transmitters number alignment in terms of both average user throughput and minimum user throughput.

Design of Transfer Alignment Algorithm with Velocity and Azimuth Matching for the Aircraft Having Wing Flexibility (유연성을 가지는 비행체를 위한 속도/방위각 정합 전달 정렬 알고리즘 설계)

  • Suktae Kang
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.214-226
    • /
    • 2023
  • A transfer alignment is used to initialize, align, and calibrate a SINS(Slave INS) using a MINS(Master INS) in motion. This paper presents an airborne transfer alignment with velocity and azimuth matching to estimate inertial sensor biases under the wing flexure influence. This study also considers the lever arm, time delay and relative orientation between MINS and SINS. The traditional transfer alignment only uses velocity matching. In contrast, this paper utilizes the azimuth matching to prevent divergence of the azimuth when the aircraft is stationary or quasi-stationary since the azimuth is less affected by the wing flexibility. The performance of the proposed Kalman filter is analyzed using two factors; one is the estimation performance of gyroscope and accelerometer bias and the other is comparing aircraft dynamics and attitude covariance. The performance of the proposed filter is verified using a long term flight test. The test results show that the proposed scheme can be effectively applied to various platforms that require airborne transfer alignment.

Study of Homeotropic Liquid Crystal Characteristics Using Photo-polymer and Homeotropic Polyimide Blended Alignment Layer via UV Irradiation Method (UV 광배향법을 통한 광폴리머와 수직 폴리이미드 혼합 배향막의 수직 배향 특성 연구)

  • Lee, Jin-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.12
    • /
    • pp.996-999
    • /
    • 2012
  • From UV irradiation, we achieved homeotropic liquid crystal alignment on blended photo-polymer layer which is composed of polyvinyl-cinnamate (PVCi) and homeotropic polyimide (PI). From vertical alignment (VA) mode, we measured threshold voltages by various PVCi doping concentration. Also, the rise time and fall time of VA cells were measured to verify the best doping concentration. Transmittance curves showed about 70% value between 380 nm and 780 nm wavelength which mean visible region.

Solution-Derived Amorphous Yttrium Gallium Oxide Thin Films for Liquid Crystal Alignment Layers

  • Oh, Byeong-Yun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.2
    • /
    • pp.109-112
    • /
    • 2016
  • We demonstrated an alternative electrically controlled birefringence liquid crystal (ECB-LC) system with ion beam (IB)-irradiated yttrium gallium oxide (YGaO) alignment films using a sol-gel process. The surface roughness of the films was dependent on the annealing temperature; aggregated particles on surface were observed at lower annealing temperatures, whereas a smooth surface could be obtained with higher annealing temperatures. Higher transmittance in the visible region was observed at higher annealing temperatures. The film had an amorphous crystallographic state irrespective of the annealing temperature. Furthermore, ECB-LC cell with our IB-irradiated YGaO film yielded faster response time when compared to ECB-LC cell with rubbed polyimide. Considering the fast response time and high transmittance, the IB-irradiated YGaO-base LC system is a powerful alternative application for the liquid crystal display industry.

A New System Development for the Spectrum Inspection of Optical Filters (광필터의 스펙트럼 검사시스템 개발)

  • Kim, Seung-Chul;Kim, Gyung-Bum
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.2 s.179
    • /
    • pp.57-64
    • /
    • 2006
  • Optical filters in WDM are passive communication components used in case of transmitting and reflecting lights with specific wavelengths. In this paper, a novel mechanism for the automatic and optical alignment has been presented. It includes minimum axes not to be coupled each other. The automatic spectrum inspection system has been developed to improve the alignment time of reference optical ray, spectrum inspection time and inspection quality, simultaneously. It has been confirmed that the proposed spectrum inspection system is faster, more precise and more reliable than those based on the conventional handwork.