• Title/Summary/Keyword: Time slice

Search Result 239, Processing Time 0.03 seconds

The Effectiveness of CT and MRI Contrast Agent for SUV in 18F-FDG PET/CT Scanning (18F-FDG PET/CT 검사에서 정량분석에 관한 CT와 MRI 조영제의 효과)

  • Cha, Sangyoung;Cho, Yonggwi;Lee, Yongki;Song, Jongnam;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.255-261
    • /
    • 2016
  • In this study, among various factors having influence on SUV, we intended to compare and analyze the change of SUV using CT(4 type) and MRI(3 type) contrast agents which are commercialized now. We used Discovery 690 PET/CT(GE) and NEMA NU2 - 1994 PET phantom as experimental equipment. We have conducted a study as follows; first, we filled distilled water to phantom about two-thirds and injected radioisotope(18F-FDG 37 MBq), contrast agent. Second, we mixed CT contrast agent with distilled water and MRI contrast agent with that water separately. And then, we stirred the fluid and filled distilled water fully not to make air bubble. In emission scan, we had 15minutes scanning time after 40 minutes mixing contrast agent with distilled water. In transmission scan, we used CT scanning and its measurement conditions were tube voltage 120 kVp, tube current 40 mA, rotation time 0.5 sec, slice thickness 3.27 mm, DFOV 30 cm. Analyzing results, we set up some ROIs in 10th, 15th, 20th, 25th, 30th slice and measured SUVmean, SUVmax. Consequently, all images mixed 3 types of MRI contrast agent with distilled water have high SUVmean as compared with pure FDG image but there was no statistical significance. In SUVmax, they have high score and there was statistical significance. And other 4 images mixed 4 types of CT contrast agent with distilled water have significance in both SUVmean and SUVmax. Attenuation correction in PET/CT has been executed through various methods to make high quality image. But we figured out that using CT and MRI contrast agents before PET/CT scanning could make distortion of image and decrease diagnostic value. In that reason, we have to sort out the priority of examination in hospital not to disturb other examination's results. Through this process, we will be able to give superior medical service to our customers.

A Study of Optimized MRI Parameters for Polymer Gel Dosimetry (중합체 겔 선량측정법을 위한 최적의 자기공명영상 변수에 관한 연구)

  • Cho, Sam-Ju;Chung, Young-Lip;Lee, Sang-Hoon;Huh, Hyun-Do;Choi, Jin-Ho;Park, Sung-Ill;Shim, Su-Jung;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.71-80
    • /
    • 2012
  • In order to verify exact dose distributions in the state-of-the-art radiation techniques, a newly designed three-dimensional dosimeter and technique has been took strongly into consideration. The main purpose of our study is to verify the optimized parameters of polymer gel as a real volumetric dosimeter in terms of the various study of MRI. We prepared a gel dosimeter by combing 8% of gelatin, 8% of MAA, and 10 mM of THPC. We used a Co-60 gamma-ray teletherapy unit and delivered doses of 0, 2, 4, 6, 8, 10, 12, and 14 Gy to each polymer gel with a solid phantom. We used a fast spin-echo pulse to acquire the characterized T2 time of MRI. The signal noise ratio (SNR) of the head & neck coil was a relatively lower sensitivity than the body coil; therefore the dose uncertainty of head & neck coil would be lower than body coil's. But the dose uncertainty and resolution of the head & neck coil were superior to the body coil in this study. The TR time between 1,500 ms and 2,000 ms showed no significant difference in the dose resolution, but TR of 1,500 ms showed less dose uncertainty. For the slice thickness of 2.5 mm, less dose uncertainty of TE times was at 4 Gy, as well, it was the lowest result over 4 Gy at TE of 12 ms. The dose uncertainty was not critical up to 6 Gy, but the best dose resolution was obtained at 20 ms up to 8 Gy. The dose resolution shows the lowest value was over 20 ms and was an excellent result in the number of excitation (NEX) of three. The NEX of two was the highest dose resolution. We concluded that the better result of slice thickness versus NEX was related to the NEX increment and thin slice thickness.

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

An Indexing Technique of Moving Point Objects using Projection (추출 연산을 활용한 이동 점 객체 색인 기법)

  • 정영진;장승연;안윤애;류근호
    • Journal of KIISE:Databases
    • /
    • v.30 no.1
    • /
    • pp.52-63
    • /
    • 2003
  • Spatiotemporal moving objects are changing their Positions and/or shape over time in real world. As most of the indices of moving object are based on the R-tree. they have defects of the R-tree which are dead space and overlap. Some of the indices amplify the defects of the R-tree. In the paper, to solve the problems, we propose the MPR-tree(Moving Point R-tree) using Projection operation which has more effective search than existing moving point indices on time slice query and spatiotemporal range query. The MPR-tree connects positions of the same moving objects over time by using linked list, so it processes the combined query about trajectory effectively. The usefulness of the Projection operation is confirmed during processing moving object queries and in practical use of space from experimentation to compare MPR-tree with existing indices of moving objects. The proposed MPR-tree would be useful in the LBS, the car management using GPS, and the navigation system.

Sliced Channel Allocation Method for Multirate Communtiaction Environments using DAMA Scheduler (Multirate 통신환경에서 DAMA 스케줄러를 이용한 슬라이스 채널 할당방법)

  • Yu, Byung-Kwan;Kim, Hae-Ki;An, Chy-Hun;Kim, Nam;Kim, Soo-Hyung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.2
    • /
    • pp.157-168
    • /
    • 1999
  • In this paper the new channel allocation method which is important in designing mobile radio system, is proposed. If the channel is allocated by time-frequency-code sliced and using DAMA scheduler, the blocking probability is lower than TA channel allocation method. With traffic load $\rho$=0.8 and 2% of blocking probability, TFS method can allocate 36 slices compared to 11 slices in TA method. At traffic load $\rho$=0.9 and 1% of blocking probability, the maximum available slices are 13 in TA method, but in TFS method 40 slices are allocated to user, so TFS method is better frequency availability by 3.75 times than TA method. TFS method could be suitable for system planning to multirate communication users.

  • PDF

Evaluation of Hippocampal Volume Based on Various Inversion Time in Normal Adults by Manual Tracing and Automated Segmentation Methods

  • Kim, Ju Ho;Choi, Dae Seob;Kim, Seong-hu;Shin, Hwa Seon;Seo, Hyemin;Choi, Ho Cheol;Son, Seungnam;Tae, Woo Suk;Kim, Sam Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.2
    • /
    • pp.67-75
    • /
    • 2015
  • Purpose: To investigate the value of image post-processing software (FreeSurfer, IBASPM [individual brain atlases using statistical parametric mapping software]) and inversion time (TI) in volumetric analyses of the hippocampus and to identify differences in comparison with manual tracing. Materials and Methods: Brain images from 12 normal adults were acquired using magnetization prepared rapid acquisition gradient echo (MPRAGE) with a slice thickness of 1.3 mm and TI of 800, 900, 1000, and 1100 ms. Hippocampal volumes were measured using FreeSurfer, IBASPM and manual tracing. Statistical differences were examined using correlation analyses accounting for spatial interpretations percent volume overlap and percent volume difference. Results: FreeSurfer revealed a maximum percent volume overlap and maximum percent volume difference at TI = 800 ms ($77.1{\pm}2.9%$) and TI = 1100 ms ($13.1{\pm}2.1%$), respectively. The respective values for IBASPM were TI = 1100 ms ($55.3{\pm}9.1%$) and TI = 800 ms ($43.1{\pm}10.7%$). FreeSurfer presented a higher correlation than IBASPM but it was not statistically significant. Conclusion: FreeSurfer performed better in volumetric determination than IBASPM. Given the subjective nature of manual tracing, automated image acquisition and analysis image is accurate and preferable.

Study on Characteristics of Numerical Analysis Method for Stability Analysis of Reinforced Slope (보강사면의 안정해석을 위한 수치해석방법의 특성에 관한 연구)

  • Kim, Joon-Seok;Kim, Ju-Yong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.8 no.3
    • /
    • pp.17-23
    • /
    • 2009
  • Conventional methods of reinforced slope analysis based on the concept of limit equilibrium have been widely adopted mainly due to their simplicity and short computation time. But depending upon the assumptions on the inter-slice forces, the factor of safety resulting from the limit equilibrium method is not uniquely determined. This paper describes a method to calculate the factor of safely of a slope using a numerical analysis. Recently some useful analysis techniques (Strength reduction method and the stability method using stress fields) by numerical analysis are proposed and their theory and characteristics applications are studied and investigated with simple examples in this paper.

  • PDF

A Study of Architectural Activities in China Jichang(吉長) during the Japanese Colonial Period - Focused on the articles of Manseon-ilbo(滿鮮日報) in 1940 - (일제강점기 길장지구 한인 관련 건축활동과 시설에 관한 연구 -만선일보의 기사를 중심으로-)

  • Han, Dong-soo
    • Journal of architectural history
    • /
    • v.24 no.4
    • /
    • pp.65-74
    • /
    • 2015
  • This paper deals with architectural activities related to Korean society in Jichang district in North East China, focused on the articles of Manseon-ilbo published there during the Japanese colonial period. Construction-related contents in the area closely connected with topical interest, publicity, and enlightenment as a local media source provide positive grounds about pending issues in colonial situations. This paper handles with articles issued in the 1940's newspapers just before the Pacific War. At that time Japanese enter in the Chinese continent, and construct a stable basis in the intimate association with Germany and Italy, countering against the United State. Among articles regarding architecture, most of contents are based on healthcare and public facilities, and urban planning. Overwhelmingly the most popular articles are about new constructions of educational facilities and residential matters. The shortage of goods and the excessive concentration of population resulted in urban and house problems, which were particularly much more serious in Korea society. Such social atmosphere made all activities regarding building constructions, in particular educational facilities, in civil level rather than the helps of the Japanese colonial government. Thus, through education and house matters we can read a slice of Korean society to survive in the colonial environment of Jichang district.

Visual-Attention-Aware Progressive RoI Trick Mode Streaming in Interactive Panoramic Video Service

  • Seok, Joo Myoung;Lee, Yonghun
    • ETRI Journal
    • /
    • v.36 no.2
    • /
    • pp.253-263
    • /
    • 2014
  • In the near future, traditional narrow and fixed viewpoint video services will be replaced by high-quality panorama video services. This paper proposes a visual-attention-aware progressive region of interest (RoI) trick mode streaming service (VA-PRTS) that prioritizes video data to transmit according to the visual attention and transmits prioritized video data progressively. VA-PRTS enables the receiver to speed up the time to display without degrading the perceptual quality. For the proposed VA-PRTS, this paper defines a cutoff visual attention metric algorithm to determine the quality of the encoded video slice based on the capability of visual attention and the progressive streaming method based on the priority of RoI video data. Compared to conventional methods, VA-PRTS increases the bitrate saving by over 57% and decreases the interactive delay by over 66%, while maintaining a level of perceptual video quality. The experiment results show that the proposed VA-PRTS improves the quality of the viewer experience for interactive panoramic video streaming services. The development results show that the VA-PRTS has highly practical real-field feasibility.

The Role of AiiA, a Quorum-Quenching Enzyme from Bacillus thuringiensis, on the Rhizosphere Competence

  • Park, Su-Jin;Park, Sun-Yang;Ryu, Choong-Min;Park, Seung-Hwan;Lee, Jung-Kee
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.9
    • /
    • pp.1518-1521
    • /
    • 2008
  • Bacteria sense their population density and coordinate the expression of target genes, including virulence factors in Gram-negative bacteria, by the N-acylhomoserine lactones (AHLs)-dependent quorum sensing (QS) mechanism. In contrast, several soil bacteria are able to interfere with QS by enzymatic degradation of AHLs, referred to as quorum quenching. A potent AHL-degrading enzyme, AiiA, from Bacillus thuringiensis has been reported to effectively attenuate the virulence of bacteria by quorum quenching. However, little is known about the role of AiiA in B. thuringiensis itself. In the present study, an aiiA-defective mutant was generated to investigate the role of AHA in rhizosphere competence in the root system of pepper. The aiiA mutant showed no detectable AHL¬-egrading activity and was less effective for suppression of soft-rot symptom caused by Erwinia carotovora on the potato slice. On the pepper root, the survival rate of the aiiA mutant significantly decreased over time compared with that of wild type. Interestingly, viable cell count analysis revealed that the bacterial number and composition of E. carotovora were not different between treatments of wild type and the aiiA mutant. These results provide evidence that AHA can play an important role in rhizosphere competentce of B. thuringiensis and bacterial quorum quenching to Gram-negative bacteria without changing bacterial number or composition.