• 제목/요약/키워드: Time interval measurement

검색결과 286건 처리시간 0.028초

VISUALIZATION AND MEASUREMENT OF A NARROW-CONE DI GASOLINE SPRAY FOR THE IMPINGEMENT ANALYSIS

  • Park, J.S.;Im, K.S.;Kim, H.S.;Lai, M.C.
    • International Journal of Automotive Technology
    • /
    • 제5권4호
    • /
    • pp.221-238
    • /
    • 2004
  • Wall interactions of direct injection spray were investigated using laser-sheet imaging, shadowgraphy, wetted footprint and phase Doppler interferometry techniques. A narrow-cone high-pressure swirl injector is used to inject iso-octane fuel onto a plate, which has three different impact angles inside a pressurized chamber. Heated air and plate conditions were compared with unheated cases. Injection interval was also varied in the heated case to compare dry- and wet- wall impingement behaviors. High-speed macroscopic Mie-scattering images showed that presence of wall and air temperature has only minor effect on the bulk spray structure and penetration speed for the narrow-cone injector tested. The overall bulk motions of the spray plume and its spatial position at a given time are basically unaffected until a few millimeters before impacting the wall. The surface properties of the impact surface, such as the temperature, the presence of a preexisting liquid film also have a small effect on the amount of wetting or the wetted footprint; however, they have strong influence on what occurs just after impact or after a film is formed. The shadowgraph in particular shows that the plate temperature has a significant effect on vapor phase propagation. Generally, 10-20% faster horizontal vapor phase propagation is observed along the wall at elevated temperature condition. For impingement onto a preexisting film, more splash and evaporation were also observed. Contrary to some preconceptions, there is no significant splashing and droplet rebounding from surfaces that are interposed in the path of the DI gasoline spray, especially for the oblique impact angle cases. There also appears to be a dense spray front consists of large sac spray droplets in the oblique impact angle cases. The bulk of the spray is not impacted on the surface, but rather is deflected by it The microscopic details as depicted by phase Doppler measurements show that the outcome of the droplet impaction events can be significantly influenced. Only droplets at the spray front have high enough Weber numbers for wall impact to wet, splash or rebound. Using the sign of vertical velocity, the time-resolved downward droplets and upward droplets are compared. The Weber number of upward moving droplets, which seldom exceeds unity, also decreases as the impact angle decreases, as the droplets tend to impact less and move along the wall in the deflected spray plume.

자침이 중풍환자의 뇌파 변화에 미치는 영향 (The Effects of Acupuncture on the Electroencephalogram of Patients with Stroke)

  • 윤가영;박지민;김동혁;선종인;강중원;남동우;이승덕;최도영;이재동
    • Journal of Acupuncture Research
    • /
    • 제29권5호
    • /
    • pp.1-16
    • /
    • 2012
  • Objectives : The purpose of this study was to examine the effects of manual acupuncture at the $LI_4$, $ST_{36}$ and $LR_3$ on Electroencephalogram(EEG) of patients with stroke. Methods : 32 channel EEG measurement was carried out in 35 Stroke patients(23 males and 12 females). EEG was measured for 21 minutes(made up of 7 sessions, 1 session means 3 minutes time interval) including 15 minutes(5 sessions) of acupuncture time. Power spectrum analysis was used as a measure of complexity. Statistical analysis was performed using Linear mixed model and DUNNETT's multiple comparison. Results : The results were as follows; 1. EEG amplitude was reduced during acupuncture except electrodes PG1 and PG2. 2. There was a notable change during 6~9 minutes after needling in ${\delta}{\cdot}{\beta}{\cdot}{\gamma}$ wave, and during 6~9 minutes after needling in ${\Theta}{\cdot}{\alpha}$ wave. Overall, during 6~9 minutes after needling. 3. TP8 is a common significant electrode among five wave forms. Conclusions : These results suggest that TP8 could be typical electrodes and change of EEG compared to baseline happens most often during 6~9 minutes after manipulated acupuncture at the $LI_4$, $ST_{36}$ and $LR_3$ of patients with stroke.

영상정합을 이용한 교통밀도 수집방법과 수집 데이터 비교분석 (A study on the Traffic Density Collect System using View Synthesis and Data Analysis)

  • 박범진;노창균
    • 한국ITS학회 논문지
    • /
    • 제17권5호
    • /
    • pp.77-87
    • /
    • 2018
  • 교통밀도는 교통수요와 가장 직접적인 관계가 있으므로 거시적인 지표 중에서 가장 중요하다고 알려져 있으며(Traffic Engineering, 2004), 특정시각 주어진 거리 안의 존재하는 차량의 대수로 정의한다. 하지만, 밀도는 기상과 도로조건 및 비용 상의 문제로 인하여 현장에서 직접 수집이 어렵다. 이런 이유로 속도와 교통량보다 상대적으로 연구가 활발하게 이루어지지는 않아 수집방법에 관한 다양한 시도뿐만 아니라 측정된 값의 정확도에 관한 연구가 많이 부족하다. 이에 본 논문에서는 밀도를 측정할 수 있는 방법으로 여러 대의 카메라 영상을 정합(synthesis)하는 기술을 활용하였다. 이러한 밀도수집시스템으로 수집한 밀도를 정의에 기반한 참값으로 선정하고, 이 값을 전통적인 측정방법들로 산출한 밀도와 비교하였다. 비교결과, 관계식(fundamental equation)을 이용한 산출방법으로 산출한 밀도 값이 참값과 비교하여 RMSE(Root Mean Square Error)가 1.8-2.5로 가장 참값에 가깝다. 또한 향후 밀도를 직접 수집할 때 유의하여할 수집 간격 등의 간과하기 쉬운 이슈사항을 순간밀도와 평균밀도를 산출하여 알아보았다. 실험 사이트의 실제 교통상황은 LOS B임에도 불구하고, 초 당 순간밀도는 최대(16veh/km)에서 최소 2(veh/km)의 값이 다양하게 관측되어 교통상황의 판단이 어려웠다. 하지만 30초 간격으로 15분 평균밀도는 8.3-7.9(veh/km)로 정확하게 LOS B를 판단하였다.

다채널 전기전도도 모니터링 시스템의 개발과 연안지역 공내수 모니터링에 대한 적용 사례 (The Development of Multi-channel Electrical Conductivity Monitoring System and its Application in the Coastal Aquifer)

  • 신제현;황세호;박권규;박윤성;변중무
    • 지구물리와물리탐사
    • /
    • 제8권2호
    • /
    • pp.156-162
    • /
    • 2005
  • 연안지역의 해수침투와 관련된 연구에서 전기전도도의 변화를 파악하는 것은 매우 중요한 문제 중에 하나이며, 특히 염/담수 영역에서의 전기전도도 모니터링은 양수로 인한 염수의 이동을 효과적으로 파악할 수 있기 때문에 양수 설계 최적화에 매우 유용하게 이용될 수 있다. 특히, 공내수의 수직적인 전기전도도 분포는 해수침투대의 특성에 따라서 변하기 때문에 여러 심도에 걸친 동시 모니터링이 필요하다. 본 연구에서는 상업용 모니터링 장비에 비하여 계측장비의 구성비용이 상대적으로 저렴하며 장기간 연속 모니터링 및 측정 변수들을 실시간으로 제어할 수 있는 원격 다채널 모니터링 시스템을 개발하였으며, 전남 영광지역의 해수침투 조사 시추공에 적용하여 양수에 따른 지하수의 전기전도도 변화 및 그 양상을 고찰하였다. 양수를 병행하면서 수행한 모니터링 결과, 일정 심도에서 전기전도도의 증가 또는 감소는 사질층 또는 암반의 균열을 따라 유동하는 지하수의 복합적인 영향임을 파악할 수 있었으며 이와 같은 결과는 양수 전$\cdot$후에 실시한 물리검층 결과와도 잘 일치하였다. 양수에 의한 공내수의 전기전도도 변화 특성을 심도에 따라서 실시간으로 측정할 수 있는 다채널 모니터링 시스템은 염분농도를 고려한 연안지역 지하수자원 확보에 유용하게 이용될 것으로 판단된다.

소지역 실업률의 패널추정을 위한 일반화커널추정방정식 (Generalized kernel estimating equation for panel estimation of small area unemployment rates)

  • 심주용;김영원;황창하
    • Journal of the Korean Data and Information Science Society
    • /
    • 제24권6호
    • /
    • pp.1199-1210
    • /
    • 2013
  • 오늘날 높은 실업률은 대부분의 국가에서 중요한 문제 중의 하나이다. 한편 소지역의 노동 관련 통계에 대한 요구가 지난 몇년간 급속도로 증가하였다. 그러나 대부분의 공식통계를 생산하기 위한 표본설계는 대영역의 통계를 생산할 목적으로 설계되기 때문에 소지역의 경우 배정되는 표본조사단위수가 극히 적어 신뢰성 있는 통계 산출이 어렵다. 그리고 소지역 추정에 대한 대부분의 기존 연구들은 특정 시점에서의 추정에 국한되어 왔다. 그러나 대부분의 공식통계들은 월, 분기 또는 연 단위로 측정되는 패널자료이기 때문에 이를 고려한 추정방법이 필요하다. 본 논문에서는 패널자료의 분석을 위해 유용하게 사용되고 있는 일반화추정방정식의 비모수적 버전인 일반화커널추정방정식을 도출하여 조사시점을 고려한 소지역 실업률의 추정에 활용하는 방안을 제안한다. 모의실험을 통하여 일반화커널추정방정식 방법, 일반화추정방정식 방법 및 일반화선형모형과 비교한다. 그리고 2005년 1월부터 12월까지 경상남도 및 울산광역시의 25개 시군구의 경제활동인구조사의 패널자료에 위에서 언급한 세 가지 방법을 적용하여 해당 소지역의 월별 실업률을 추정한다.

동해중부에서 HF Radar를 이용한 파랑 및 해수유동 관측 (Wave and surface current measurement with HF radar in the central east coast of Korea)

  • 김무홍;김경수;김현성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권6호
    • /
    • pp.771-780
    • /
    • 2014
  • 배열형(Array type)의 HF Radar를 임원항(Site A)과 후정리 해변(Site B)에 설치하여 동해연안에 대한 실시간 파랑과 해류를 관측하였다. 본 연구에 사용된 WERA (WavE RAdar)는 2000년 독일 Helzel사에서 개발된 것으로 24.525 MHz의 주파수 대역을 사용한다. 각 사이트는 4기의 송신기와 8기의 수신기로 구성되어 있는 8 채널 시스템이며, 현재 30분 주기로 관측하여 자료를 생성하고 있다. 파랑은 최대 약 25 km, 해류는 최대 약 50 km의 관측 범위를 나타내며, 150 kHz의 대역폭을 사용하여 1.5 km 간격의 격자 해상도를 갖는다. HF Radar를 이용하여 관측한 파랑 자료는 현장에서 관측한 파랑계 자료와 비교 검증을 하였으며, 해류 자료는 국립해양조사원에서 제공한 월별 동해평균표층 해류도와 해류흐름 패턴과 비교하였다. 파랑의 비교 자료들에 대한 회귀선과의 편차는 주성분 분석(Principle Component Analysis)으로 계산하였고, 그 결과로 상관관계 0.86와 RMSD 0.186을 보였다. 또한 동해연안의 해수유동에 대한 장기간의 변화를 분석해본 결과 8월과 9월의 연안에서는 북한한류가 남쪽방향으로, 외해에서는 동한난류가 북쪽방향으로 흐르는 흐름이 나타났다.

케이블형 Wi-Fi 기반 실내 공간의 노드 배치 판별 분석에 관한 연구 (A study on the discriminant analysis of node deployment based on cable type Wi-Fi in indoor)

  • 진현철;김원열;김종찬;김윤식;서동환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권9호
    • /
    • pp.836-841
    • /
    • 2016
  • Wi-Fi를 이용한 실내 위치인식 시스템은 2차원 이상의 실내 공간 정보와 노드 위치정보 등이 결합된 무선 신호 지도의 제작이 필수적이다. 이를 구성하기 위한 과정인 Wi-Fi 노드의 RSSI 측정 및 배치 정보 확인에 시간 비용이 크게 발생한다. 특히 기존의 무선 환경이 변하거나 새로운 공간이 만들어질 경우 실내 위치기반의 서비스를 제공하기 위해 노드의 재설치 및 새로운 실내 무선 지도 제작이 필요하다. 이러한 문제로 인해 발생되는 시간 소비를 줄이기 위하여 본 논문에서는 3 m 간격으로 설치된 Cable형 Wi-Fi를 사용하여 정확한 노드의 배치 위치를 판별 및 공간 분석이 가능한 RSSI 가시화 및 Sobel 필터 기반 경계선 검출을 통해 복도 구간의 직선과 곡선을 구분하는 알고리즘을 제안한다. Cable형 Wi-Fi는 동일한 전력선으로 연결되어 있으므로 노드가 일정한 간격으로 설치된 순서를 알 수 있다는 장점이 있다. 이를 기반으로, 공간의 특정 구간을 분석이 가능하도록 측정된 RSSI 기반 가시화과정을 통해 신호의 분포를 확인하고 이를 Sobel 필터 기반 경계선 검출 및 Total RSSI Distribution(TRD) 연산을 통하여 분석한다. Raw data와 제안하는 알고리즘 신호강도를 비교해본 결과 제안하는 알고리즘의 신호 세기는 곡선 구간에서 경계선 특성이 평균 13.73 % 증가하였다. 또한 직선 구간 신호의 세기를 평균 34.16 % 감소시켜 직선구간과 곡선구간의 특성이 개선되었다.

임플랜트 식립부위 형성시 골조직의 온도변화에 관한 연구 (A STUDY ON THE TEMPERATURE CHANGES OF BONE TISSUES DURING IMPLANT SITE PREPARATION)

  • 김평일;김영수;장경수;김창회
    • 대한치과보철학회지
    • /
    • 제40권1호
    • /
    • pp.1-17
    • /
    • 2002
  • The purpose of this study is to examine the possibility of thermal injury to bone tissues during an implant site preparation under the same condition as a typical clinical practice of $Br{\aa}nemark$ implant system. All the burs for $Br{\aa}nemark$ implant system were studied except the round bur The experiments involved 880 drilling cases : 50 cases for each of the 5 steps of NP, 5 steps of RP, and 7 steps of WP, all including srew tap, and 30 cases of 2mm twist drill. For precision drilling, a precision handpiece restraining system was developed (Eungyong Machinery Co., Korea). The system kept the drill parallel to the drilling path and allowed horizontal adjustment of the drill with as little as $1{\mu}m$ increment. The thermocouple insertion hole. that is 0.9mm in diameter and 8mm in depth, was prepared 0.2mm away from the tapping bur the last drilling step. The temperatures due to countersink, pilot drill, and other drills were measured at the surface of the bone, at the depths of 4mm and 8mm respectively. Countersink drilling temperature was measured by attaching the tip of a thermocouple at the rim of the countersink. To assure temperature measurement at the desired depths, 'bent-thermocouples' with their tips of 4 and 8mm bent at $120^{\circ}$ were used. The profiles of temperature variation were recorded continuously at one second interval using a thermometer with memory function (Fluke Co. U.S.A.) and 0.7mm thermocouples (Omega Co., U.S.A.). To simulate typical clinical conditions, 35mm square samples of bovine scapular bone were utilized. The samples were approximately 20mm thick with the cortical thickness on the drilling side ranging from 1 to 2mm. A sample was placed in a container of saline solution so that its lower half is submerged into the solution and the upper half exposed to the room air, which averaged $24.9^{\circ}C$. The temperature of the saline solution was maintained at $36.5^{\circ}C$ using an electric heater (J. O Tech Co., Korea). This experimental condition was similar to that of a patient s opened mouth. The study revealed that a 2mm twist drill required greatest attention. As a guide drill, a twist drill is required to bore through a 'virgin bone,' rather than merely enlarging an already drilled hole as is the case with other drills. This typically generates greater amount of heat. Furthermore, one tends to apply a greater pressure to overcome drilling difficulty, thus producing even greater amount heat. 150 experiments were conducted for 2mm twist drill. For 140 cases, drill pressure of 750g was sufficient, and 10 cases required additional 500 or 100g of drilling pressure. In case of the former. 3 of the 140 cases produced the temperature greater than $47^{\circ}C$, the threshold temperature of degeneration of bone tissue (1983. Eriksson et al.) which is also the reference temperature in this study. In each of the 10 cases requiring extra pressure, the temperature exceeded the reference temperature. More significantly, a surge of heat was observed in each of these cases This observations led to addtional 20 drilling experiments on dense bones. For 10 of these cases, the pressure of 1,250g was applied. For the other 10, 1.750g were applied. In each of these cases, it was also observed that the temperature rose abruptly far above the thresh old temperature of $47^{\circ}C$, sometimes even to 70 or $80^{\circ}C$. It was also observed that the increased drilling pressure influenced the shortening of drilling time more than the rise of drilling temperature. This suggests the desirability of clinically reconsidering application of extra pressures to prevent possible injury to bone tissues. An analysis of these two extra pressure groups of 1,250g and 1,750g revealed that the t-statistics for reduced amount of drilling time due to extra pressure and increased peak temperature due to the same were 10.80 and 2.08 respectively suggesting that drilling time was more influenced than temperature. All the subsequent drillings after the drilling with a 2mm twist drill did not produce excessive heat, i.e. the heat generation is at the same or below the body temperature level. Some of screw tap, pilot, and countersink showed negative correlation coefficients between the generated heat and the drilling time. indicating the more the drilling time, the lower the temperature. The study also revealed that the drilling time was increased as a function of frequency of the use of the drill. Under the drilling pressure of 750g, it was revealed that the drilling time for an old twist drill that has already drilled 40 times was 4.5 times longer than a new drill The measurement was taken for the first 10 drillings of a new drill and 10 drillings of an old drill that has already been used for 40 drillings. 'Test Statistics' of small samples t-test was 3.49, confirming that the used twist drills require longer drilling time than new ones. On the other hand, it was revealed that there was no significant difference in drilling temperature between the new drill and the old twist drill. Finally, the following conclusions were reached from this study : 1 Used drilling bur causes almost no change in drilling temperature but increase in drilling time through 50 drillings under the manufacturer-recommended cooling conditions and the drilling pressure of 750g. 2. The heat that is generated through drilling mattered only in the case of 2mm twist drills, the first drill to be used in bone drilling process for all the other drills there is no significant problem. 3. If the drilling pressure is increased when a 2mm twist drill reaches a dense bone, the temperature rises abruptly even under the manufacturer-recommended cooling conditions. 4. Drilling heat was the highest at the final moment of the drilling process.

주장훈련이 간호사의 스트레스 반응과 주장행동에 미치는 효과 (The Effect of Assertiveness Training on the Stress Response and Assertive Behavior of Nurses)

  • 하나선
    • 간호행정학회지
    • /
    • 제5권1호
    • /
    • pp.149-167
    • /
    • 1999
  • This study was designed and carried out to investigate the effect of Assertiveness Training on the stress response and assertive behavior of emergency room nurses from September 22, to December 21. 1997. The subjects were 45 emergency room nurses of three general hospitals of Korea University Medical Center; 25 assigned for the experimental and 20 for the control group. The Assertive Training Program was composed of cognitive training, behavioral training and progressive muscle relaxation. The subjects of the experimental group carried out the 15-minute progressive muscle relaxation according to recorded-tape once a day for 6 weeks. The cognitive and the behavioural training were conducted by the investigator for 5-8 subjects at a time for 9 series, at an interval of 4-5 days. Post-measurement were administered to all sujects in two groups three weeks after the last session. The level of general stress (Cline, 1992), job stress (Kim & Koo, 1984), physiological response to stress (cortisol, epinephrine, norepinephrine), symptoms of stress (Lee, 1984) and assertive behavior (Kim, 1982) were measured before the first and after the last experiments. Data were analysed by x2, t, paired t, Wilcoxon signed rank tests Wilcoxon rank sums tests. The results are as follows : 1. The level of general stress of the experimental group was lower than that of the control group, however, no significant difference between the two groups (P=0.234) was revealed. 2. A significant reduction of job stress was revealed in the experimental group (P=0.017). 1) A significant reduction of interpersonal conflicts in the experimental group was revealed (P=0.018). 3. The physiological stress-response were analyzed as follows : 1) A decrease of Cortisol in both the experimental and the control groups was noticed, however, the difference between the two groups was not statistically significant (P=0.991). Pre-and post-measurement of the level of Corti sol revealed that a notable decrease in the experimental group and an increase in the control group with no significant difference in the day-day subjects (P=0.765), a significant decrease was noted on the level of Cortisol of the experimental group in the night-night nurses (P=0.036). 2) An increase of Epinephrine in both groups was noticed, however, a difference was not statistically significant between the two groups (P=0.082). Pre-and post-measurement of the level of Epinephrine revealed that a notable decrease in the experimental group and an increase in the control group with no significant difference in the day-day subjects (P=0.136). increases were noted on the level of Epinephrinel of both groups in the night-night nurses (P=0.136), 3) The level of Norepinephrine of the experimental group was significantly decreased (P=0.020). Pre-and post-measurement of the level of Norepinephrine revealed that a notable decrease in the experimental group and an increase in the control group with no significant difference in the day-day subjects (P=0.073). a significant decrease was noted on the level of Norepinephrine of the experimental group in the night-night nurses (P=0.036), 4. Symptoms of stress were reduced in both groups, with no significant differences between the groups (P=0.127). 1) The physical stress symptoms were reduced in both groups, with no significant difference (P=0.386), 2) The cognitive-behavioral stress symptoms were significantly reduced in the experimental group (P=0.037). 3) The emotional stress symptoms were reduced in both groups with no significant difference between the groups (P=0.110). 5. The assertive behavior was significantly increased in the experimental group (P=0.000). This study signified the Assertiveness Training as an effective mean of self intervention for the reduction of stress of nurses assigned to emergency rooms.

  • PDF

Microcomputer를 이용(利用)한 농업기계요소(農業機械要素)의 Strain 측정(測定)에 관(關)한 연구(硏究) (Study on Strain Measurement of Agricultural Machine Elements Using Microcomputer)

  • 김기대;김태균;김성래
    • 농업과학연구
    • /
    • 제8권1호
    • /
    • pp.90-96
    • /
    • 1981
  • 농업기계(農業機械)의 개량(改良) 및 개발(改發)의 새로운 설계(設計)를 위(爲)하여는 기계요소(機械要素)의 strain의 정밀측정(精密測定)이 중요(重要)하다. 각종(各種) 농업기계요소(農業機械要素)의 strain 측정(測定)을 위(爲)하여 현재(現在) 널리 사용(使用)하고 있는 strain 계측장치(計測裝置)의 Recorder는 1,000m/s 이하(以上)의 고속측정(高速測定)에는 이용(利用)하기 어려울뿐아니라 포장(圃場)에서 실험(實驗)할 경우는 매우 불편(不便)하고 또한 Recording paper에 나타난 Analog Data를 인력(人力)에 의(依)해 Digital로 변환(變換)해야 하므로 이때의 분석소요시간(分析所要時間)이 많이 소요(所要)될 뿐 아니라 오차(誤差)의 발생요인(發生要因)도 많이 내포(內包)하고 있다. 본(本) 연구(硏究)는 Amplifier에서 출력(出力)되는 Analog Signal을 A/D 변환기(變換器)를 갖춘 마이크로 콤퓨터에서 실시간(實時間)으로 측정(測定)하고, 이를 보통의 카세트녹음기(錄音器)에 수록(收錄)하였다가 실험후(實驗後) 콤퓨터에 보내 처리(處理)하는 방안(方案)에 관(關)해 연구(硏究)를 실시(實施)한 바 그 결과(結果)를 요약(要約)하면 다음과 같다. 1. 측정시간간격(測定時間間隔), 사용(使用) channel수(數) 및 data수(數)를 자유(自由)로 조정(調整)할 수 있는 측정(測定) program을 개발(開發)하였으며 특(特)히 측정시간(測定時間) 간격(間隔)은 고속측정(高速測定)이 최소(最少) $62{\mu}s$까지 가능(可能)하였다. 2. Calibration은 funcfion generator와 Oscilloscope를 이용(利用)하여 삼각파(三角波)를 넣어 측정(測定)한 결과(決果)를 콤퓨터에서 plotling한 결과(結果) 정확(正確)한 삼각파(三角波)를 얻을 수 있어 phase distorsion, amplitude distorsion의 문제(問題)가 전혀 없는 것이 인정(認定)되었다. 3. 진동주기(振動週期)가 0.019초(秒)인 Cantilever beam vibrafor의 strain 변화(變化)를 이 실험장치(實驗裝置)로 측정시간(測定時間) 간격(間隔) 1.0ms로 측정(測定)하여 콤퓨터에서 plotting한 결과(結果) 이론치(理論値)와 잘 일치(一致)하는 진동곡선(振動曲線)을 얻었다. 4. 마이크로 콤퓨터는 농업기계요소(農業機械要素)의 strain 측정(測定)에 이용(利用)하면 분석시간(分析時間)이 절약(節約)되고 기록용지(記錄用紙)를 사용(使用)치 않아 경제적(經濟的)일 뿐 아니라 포장실험(圃場實驗) 적응성(適應性)이 우수(優秀)하고 정밀고속측정등(精密高速測定等) 우수(優秀)한 성능(性能)을 갖춘 것으로 인정(認定)된다.

  • PDF