• Title/Summary/Keyword: Time Domain Noise

Search Result 593, Processing Time 0.027 seconds

Expectation and Satisfaction of Parents with Inpatient Hospital Service (입원 아동 부모의 병원서비스 기대수준과 만족도)

  • Choi, Eun Kyoung;Kim, Sun Hee;Jung, Song Yi;Cho, Eun Hee;Choi, Kyung Sook;Sim, So Jung;Mok, Mi Soo;Kang, Eun Kyung;Cho, Youn Kyoung;Byun, Eun Sook;Kim, Kyung Hee;Yoo, Il Young
    • Journal of Korean Clinical Nursing Research
    • /
    • v.17 no.2
    • /
    • pp.228-238
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate parent expectation and satisfaction with respect to pediatric inpatient care and to identify the variables related to parent satisfaction. Methods: The study was conducted in pediatric wards of a tertiary children's hospital in Korea. The participants were 361 parents of children who were inpatients. Data were collected using a structured questionnaire (The Pediatric Family Satisfaction Questionnaire) at the time of discharge. Results: The highest parent expectation domain was medical service. The parents were most satisfied with nursing service and least satisfied with general hospital service and accommodation. The parents expressed lower satisfaction with hospital facilities, equipment, noise, cleanliness, and communication by health care professionals. Parents with younger children reported higher expectation from the complete hospital service and those who had a longer length of stay reported higher expectation from the nursing service. Conclusion: To improve the quality of hospital services, we need to understand parent expectation and improve and provide clear communication. In addition, the general hospital service and accommodation should not be overlooked for improvement.

Model Experiments and Behavior Analyses of The Tunnel Support Using TDR Sensor (TDR센서를 이용한 터널 지보재의 모형 실험과 거동해석)

  • Park, Min-Cheol;Han, Heui-Soo;Cho, Jae-Ho;Yang, Nam-Young
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.9
    • /
    • pp.35-45
    • /
    • 2011
  • This paper is to analyze the behaviors of tunnel support by TDR(Time Domain Reflectometry) sensor using electrical pulse. To analysis the behaviors of tunnel support, Copper tape as sensing materials was studied for on-site installation. Copper tape to the top of the glass tape, foam tape, and shielding the lower part was used electromagnetic shield sheet. For a high sensitivity to load and fill out the measurement noise emissions has been developed for the production of materials. This sensing material through the tunnel model tests for the change by surcharge load in TDR data were analyzed. Varing stiffness and support of conditions were determined the change of TDR data through PVC pipe tunnel section model tests. By comparing TDR data and finite element analysis, the behaviors of the tunnel support materials were analyzed qualitatively.

Derivation of design equations for various incremental delta sigma analog to digital converters (다양한 증분형 아날로그 디지털 변환기의 설계 방정식 유도)

  • Jung, Youngho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.11
    • /
    • pp.1619-1626
    • /
    • 2021
  • Unlike traditional delta-sigma analog-to-digital converters, incremental analog-to-digital converters enable 1:1 mapping of input and output through a reset operation, which can be used very easily for multiplexing. Incremental analog-to-digital converters also allow for simpler digital filter designs compared to traditional delta-sigma converters. Therefore, starting with analysis in the time domain of the delayed integrator and non-delayed integrator, which are the basic blocks of analog-to-digital converter design, the design equations of a second-order input feed-forward, extended counting, 2+1 MASH (Multi-stAge-noise-SHaping), 2+2 MASH incremental analog-to-digital converter are derived in this paper. This allows not only prediction of the performance of the incremental analog-to-digital converter before design, but also the design of a digital filter suitable for each analog-to-digital converter. In addition, extended counting and MASH design techniques were proposed to improve the accuracy of analog-to-digital converters.

Systematic comparisons among OpenFAST, Charm3D-FAST simulations and DeepCWind model test for 5 MW OC4 semisubmersible offshore wind turbine

  • Jieyan Chen;Chungkuk Jin;Moo-Hyun Kim
    • Ocean Systems Engineering
    • /
    • v.13 no.2
    • /
    • pp.173-193
    • /
    • 2023
  • Reliable prediction of the motion of FOWT (floating offshore wind turbine) and associated mooring line tension is important in both design and operation/monitoring processes. In the present study, a 5MW OC4 semisubmersible wind turbine is numerically modeled, simulated, and analyzed by the open-source numerical tool, OpenFAST and in-house numerical tool, Charm3D-FAST. Another commercial-level program FASTv8-OrcaFlex is also introduced for comparison for selected cases. The three simulation programs solve the same turbine-floater-mooring coupled dynamics in time domain while there exist minor differences in the details of the program. Both the motions and mooring-line tensions are calculated and compared with the DeepCWind 1/50 scale model-testing results. The system identification between the numerical and physical models is checked through the static-offset test and free-decay test. Then the system motions and mooring tensions are systematically compared among the simulated results and measured values. Reasonably good agreements between the simulation and measurement are demonstrated for (i) white-noise random waves, (ii) typical random waves, and (iii) typical random waves with steady wind. Based on the comparison between numerical results and experimental data, the relative importance and role of the differences in the numerical methodologies of those three programs can be observed and interpreted. These comparative-study results may provide a certain confidence level and some insight of potential variability in motion and tension predictions for future FOWT designs and applications.

High Efficiency Tapered Waveguide Antenna for End-fire Optical Phased Array Device (종단방출형 광위상배열 장치를 위한 고효율 안테나)

  • Byeongchan Park;Nan Ei Yu
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.6
    • /
    • pp.235-240
    • /
    • 2023
  • The optical signal injected into an end-fire optical phased array propagates along the waveguides inside the device and is emitted from the edge of the antenna. In general, reflection and scattering occur at the boundary, thereby reducing the emission efficiency of the optical signal. In this article, we propose a silicon nitride (Si3N4) tapered waveguide antenna structure whose width is tapered toward the emitting edge, achieving high emission efficiency operating at the 1,550 nm wavelength. The Si3N4 tapered waveguide antenna was numerically designed using the 3D finite-difference time-domain method. The optical signal emission efficiency increased from 78% to 96.3%, while reflectance decreased from 22% to 3.7% compared with the untapered waveguide antenna counterpart. This result will not only boost the optical signal intensity but also mitigate optical noise resulting from back reflection along the waveguide in the end-fire optical phased array device.

Contrast Improvement in Diagnostic Ultrasound Strain Imaging Using Globally Uniform Stretching (진단용 초음파 변형률 영상에서 전역 균일 신장에 의한 콘트라스트 향상)

  • Kwon, Sung-Jae;Jeong, Mok-Kun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.8
    • /
    • pp.504-508
    • /
    • 2010
  • In conventional diagnostic ultrasound strain imaging, when displaying strain image on a monitor, human visual characteristics are utilized such that hard regions are displayed as dark and soft regions are displayed as bright. Thus, hard regions representing tumor or cancer are displayed as dark, decreasing the contrast inside the lesion. Because the lesion area is stiff and thus displayed as dark, a method of inverting the image brightness and thereby increasing the contrast in the lesion for better diagnostic purposes is proposed wherein a postcompression signal is extended in the time domain by a factor corresponding to the reciprocal of the amount of the applied compression using a technique termed globally uniform stretching. Experiments were carried out to verify the proposed method on an ultrasound elasticity phantom with radio-frequency data acquired from a diagnostic ultrasound clinical scanner. It is found that the new method improves the contrast-to-noise ratio by a factor of up to about 1.8 compared to a conventional strain imaging method that employs a reversed gray color map without globally uniform stretching.

Enhanced Pulse Amplitude Estimation Method for Electronic Warfare Support (전자전 지원을 위한 향상된 펄스 세기 추정 기법)

  • Lee, Yu-Ri;Kim, Dong-Gyu;Kwak, Hyungyu;Kim, Hyoung-Nam
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.3
    • /
    • pp.649-660
    • /
    • 2017
  • In electronic warfare, the pulse amplitude, one of information of a pulse signal emitted by an enemy, is used for estimating distance from the source and for deinterleaving mixed source signals. An estimate of pulse amplitude is conventionally determined as the maximum magnitude of a Fourier transformed signal within its pulse width which is estimated pre-step in an electronic warfare receiver. However, when frequency modulated signals are received, it is difficult to estimate their pulse amplitudes with this conventional method because the energy of signals is dispersed in frequency domain. In order to overcome this limitation, this paper proposes an enhanced pulse amplitude estimation method which calculates the average power of the received pulse signal in time domain and removes the noise power of the receiver. Simulation results show that even in case the frequency modulated signal is received, the proposed method has the same performance as estimating the pulse amplitude when unmodulated signal is received. In addition, the proposed method is shown to be more robust to an estimation error of pulse width, which affects the estimation performance of pulse amplitude, than the conventional method.

Super Resolution Algorithm Based on Edge Map Interpolation and Improved Fast Back Projection Method in Mobile Devices (모바일 환경을 위해 에지맵 보간과 개선된 고속 Back Projection 기법을 이용한 Super Resolution 알고리즘)

  • Lee, Doo-Hee;Park, Dae-Hyun;Kim, Yoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.1 no.2
    • /
    • pp.103-108
    • /
    • 2012
  • Recently, as the prevalence of high-performance mobile devices and the application of the multimedia content are expanded, Super Resolution (SR) technique which reconstructs low resolution images to high resolution images is becoming important. And in the mobile devices, the development of the SR algorithm considering the operation quantity or memory is required because of using the restricted resources. In this paper, we propose a new single frame fast SR technique suitable for mobile devices. In order to prevent color distortion, we change RGB color domain to HSV color domain and process the brightness information V (Value) considering the characteristics of human visual perception. First, the low resolution image is enlarged by the improved fast back projection considering the noise elimination. And at the same time, the reliable edge map is extracted by using the LoG (Laplacian of Gaussian) filtering. Finally, the high definition picture is reconstructed by using the edge information and the improved back projection result. The proposed technique removes effectually the unnatural artefact which is generated during the super resolution restoration, and the edge information which can be lost is amended and emphasized. The experimental results indicate that the proposed algorithm provides better performance than conventional back projection and interpolation methods.

Design Optimization of Differential FPCB Transmission Line for Flat Panel Display Applications (평판디스플레이 응용을 위한 차동 FPCB 전송선 설계 최적화)

  • Ryu, Jee-Youl;Noh, Seok-Ho;Lee, Hyung-Joo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.5
    • /
    • pp.879-886
    • /
    • 2008
  • This paper addresses the analysis and the design optimization of differential interconnects for Low-Voltage Differential Signaling (LVDS) applications. Thanks to the differential transmission and the low voltage swing, LVDS offers high data rates and improved noise immunity with significantly reduced power consumption in data communications, high-resolution display, and flat panel display. We present an improved model and new equations to reduce impedance mismatch and signal degradation in cascaded interconnects using optimization of interconnect design parameters such as trace width, trace height and trace space in differential flexible printed circuit board (FPCB) transmission lines. We have carried out frequency-domain full-wave electromagnetic simulations, time-domain transient simulations, and S-parameter simulations to evaluate the high-frequency characteristics of the differential FPCB interconnects. The 10% change in trace width produced change of approximately 6% and 5.6% in differential impedance for trace thickness of $17.5{\mu}m$ and $35{\mu}m$, respectively. The change in the trace space showed a little change. We believe that the proposed approach is very helpful to optimize high-speed differential FPCB interconnects for LVDS applications.

Heart Rate Signal Extraction by Using Finger vein Recognition System (지정맥 인식 시스템을 이용한 심박신호 검출)

  • Bok, Jin Yeong;Suh, Kun Ha;Lee, Eui Chul
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.6
    • /
    • pp.701-709
    • /
    • 2019
  • Recently, heart rate signal, which is one of biological signals, have been used in various fields related to healthcare. Conventionally, most of the proposed heart rate signal detection methods are contact type methods, but there is a problem of discomfort that the subject have to contact with the device. In order to solve the problem, detection study by non-contact method has been progressed recently. The detected heart rate signal can be used for finger vein liveness detection and various application using heart rate. In this paper, we propose a method to obtain heart rate signal by using finger vein imaging system. The proposed method detected the signal from the changes of the brightness value in the time domain of the infrared finger vein images and converted it into the frequency domain using the image processing algorithm. After the conversion, we removed the noise not related to the heart rate signal through band-pass filtering. In order to evaluate the accuracy of the signal, we analyzed the correlation with the signal obtained simultaneously with the finger vein acquisition device and contact type PPG sensor approved by KFDA. As a result, it was possible to confirm that the heart rate signal detected in non-contact method through the finger vein image coincides with the waveform of actual heart rate signal.