• Title/Summary/Keyword: Time Difference

Search Result 14,184, Processing Time 0.037 seconds

Understanding and Implementation Strategy of Tact Time, Pitch Time and Cycle Time (택트타임, 피치타임, 사이클타임의 이해와 적용방안)

  • Choe, Seong-Un
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.11a
    • /
    • pp.557-561
    • /
    • 2011
  • The study proposes three types of production lead time according to the production or demand pattern. First of all, it discusses the difference of three lead times. While pitch time and cycle time are used in push system with process stock and mass conveyor production, the tact time is used in pull system like as JIT based lean production system.

  • PDF

The Changes in Children's Sleeping Patterns caused by Hospitalization (입원에 따른 아동의 수면 양상의 변화)

  • Park Mun Hee;Lee Ae Ran
    • Child Health Nursing Research
    • /
    • v.4 no.2
    • /
    • pp.265-273
    • /
    • 1998
  • The purpose of this study was to identify the children's sleeping patterns, such as the sleeping hours and the nature of sleep disruptions following hospitalization and its accompanying factors. The data were collected from December, 1997 to March, 1998 using a questionnaire developed by researchers. The subjects were 76 children in a hospital. The results of this study were summarized as follows : 1. The average sleeping hours (sleep duration) at night were 10 hours and 10 minutes and 9 hours and 9 minutes before and after hospitalization respectively. There was a significant difference (p<0.01). The average sleeping hours in the day time were 1 hour 28 minutes and 2 hours and 26 minutes before and after hospitalization respectively. There was a significant difference(P<0.01). 2. The mean bed time(sleep onset) was 10: 22 pm and 10 : 28 pm before and after hospitalization respectively. There was no significant difference. 3. The mean hour of rising(sleep termination) was 7: 54 am 7 : 08 am before and after hospitalization respectively. There was a significant difference (p<0.01). 4. The mean number of sleep disruption was 0.72 and 1.94 before and after hospitalization respectively. There was a significant difference(P<0.01). The sleep disruptions were influenced by crying of other children(53.9%), lights(28.9), nursing procedures(18.4%), noise of TV(17.l%) and noise of visitors (15.8%).

  • PDF

Numerical study on temporal resolution of meteorological information for prediction of Asian dust (황사의 확산예측을 위한 기상정보의 시간해상도에 관한 수치연구)

  • Lee Soon-Hwan;Gwak Eun-Young;Ryu Chan-Su;Moon Yun-Seob
    • Journal of Environmental Science International
    • /
    • v.13 no.10
    • /
    • pp.891-902
    • /
    • 2004
  • In order to predict air pollution and Yellow-sand dispersion precisely, it is necessary to clarify the sensitivity of meteorological field input interval. Therefore numerical experiment by atmospheric dynamic model(RAMS) and atmospheric dispersion model(PDAS) was performed for evaluating the effect of temporal and spatial resolution of meteorological data on particle dispersion. The results are as follows: 1) Base on the result of RAMS simulation, surface wind direction and speed can either synchronize upper wind or not. If surface wind and upper wind do not synchronize, precise prediction of Yellow-sand dispersion is strongly associated with upwelling process of sand of particle. 2) There is no significant discrepance in distribution of particle under usage of difference temporal resolution of meteorological information at early time of simulation, but the difference of distribution of particles become large as time goes by. 3) There is little difference between calculated particles distributions in dispersion experiments with high temporal resolution of meteorological data. On the other hand, low resolution of meteorological data occur the quantitative difference of particle density and there is strong tendency to the quantitative difference.

Target Localization Method based on Extended Kalman Filter using Multipath Time Difference of Arrival (다중경로 도달시간차이를 이용한 확장칼만필터 기반의 표적 위치추정 기법)

  • Cho, Hyeon-Deok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.251-257
    • /
    • 2021
  • An underwater platform operating a passive sonar needs to acquire the target position to perform its mission. In an environment where sea-floor reflections exist, the position of a target can be estimated using the difference in the arrival time between the signals received through multipaths. In this paper, a method of localization for passive sonar is introduced, based on the EKF (Extended Kalman Filter) using the multipath time difference of arrival in underwater environments. TMA (Target Motion Analysis) requires accumulated measurements for long periods and has limitations on own-ship movement, allowing it to be used only in certain situations. The proposed method uses an EKF, which takes measurements of the time differences of the signal arrival in multipath environments. The method allows for target localization without restrictions on own-ship movement or the need for an observation time. To analyze the performance of the proposed method, simulation according to the distance and depth of the target was performed repeatedly, and the localization error according to the distance and water depth were analyzed. In addition, the correlation with the estimated position error was assessed by analyzing the arrival time difference according to the water depth.

The study on Standard Uptake Value(SUV) change according to time input difference in PET/CT scan (PET/CT 검사에서 시간 입력 차이에 따른 표준화섭취계수(SUV) 변화에 대한 고찰)

  • Kim, Kyung-Sik;Lee, Ju-Young;Jung, Woo-Young;Kim, Jung-Sun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.21-25
    • /
    • 2011
  • Purpose: $^{18}F$-FDG Fusion Whole Body PET scan is performed approximately 1 hour after injecting $^{18}F$-FDG. At this point in the injection procedure, as a tool of the criteria of time input, time of clocks or computers can be used and in the scan procedure, time of workstation can be used. In case that synchronized time input is not done in the injection and scan procedures for PET scan, time error from injection to scan can occur. This time error may affect Standard Uptake Value (SUV) being used as quantitative assessment. Therefore, in this study, we analyzed the change of SUV according to time input difference and necessity of time synchronization. Materials and Methods: The analysis was performed to 30 patients ($54.8{\pm}15.5$ years old) who examined $^{18}F$-FDG Fusion Whole Body PET scan in Department of nuclear medicine, Asan Medical Center from December 2009 to February 2010. To observe the change of SUV according to time input difference, the image was reconstructed and analyzed by artificially changing time difference of 1, 2, 3, 5, 10, 20 min against the same patients based on 60 minutes. Result: SUV of the image that reconstructed the images of 30 patients by giving intervals of 1, 2, 3, 5, 10, 20 min respectively and the image that entered original time was compared and analyzed through paired t-test. Based on 0 minute, mean SUV of aorta was changed by 0.3, 1.1, 1.4, 3.2, 4.7, 12.5% respectively and there was no statistically significant difference in 1, 2 minutes (p>0.05) but there was significant difference in 3, 5, 10, 20 min (p<0.05). The changes of $SUV_{avg}$ of liver were 1.6, 2.5, 3.0, 4.2, 6.6, 12.8% in 1, 2, 3, 5, 10, 20 min respectively and the changes of $SUV_{max}$ of primary lesion were 1.0, 1.5, 2.2, 3.5, 6.6, 12.8% respectively (p<0.05). Conclusion: Errors may occur in the process of measuring or recording variables affecting SUV such as height and weight of patients, $^{18}F$-FDG dose, Emission scan start time etc. and as these errors are more, the accurate assessment of SUV is interfered. Therefore, in order to assess SUV more accurately, it is thought that efforts to minimize these errors should be made. Of these efforts, time synchronization will be a cornerstone for accurate scanning.

  • PDF

Development and evaluation of edge devices for injection molding monitoring (사출성형공정 모니터링용 엣지 디바이스 개발 및 평가)

  • Kim, Jong-Sun;Lee, Jun-Han
    • Design & Manufacturing
    • /
    • v.14 no.4
    • /
    • pp.25-39
    • /
    • 2020
  • In this study, an edge device that monitors the injection molding process by measuring the mold vibration(acceleration) signal and the mold surface temperature was developed and evaluated its performance. During injection molding, signals of the injection start, V/P switchover, and packing end sections were obtained through the measurement of the mold vibration and the injection time and packing time were calculated by using the difference between the times of the sections. Then, the mold closed and mold open signals were obtained using a magnetic hall sensor, and cycle time was calculated by using the time difference between the mold closed time each process. As a result of evaluating the performance by comparing the process data monitored by the edge device with the shot data recorded on the injection molding machine, the cycle time, injection time, and packing time showed very small error of 0.70±0.38%, 1.40±1.17%, and 0.69±0.82%, respectively, and the values close to the actual were monitored and the accuracy and reliability of the edge device were confirmed. In addition, it was confirmed that the mold surface temperature measured by the edge device was similar to the actual mold surface temperature.

Effect of Shift Interval for the Clinical Nurse on the Circadian Rhythm (임상 간호사의 교대근무 기간이 circadian rhythm 변화에 미치는 영향)

  • 황애란;정현숙;임영신;이혜원;김조자
    • Journal of Korean Academy of Nursing
    • /
    • v.21 no.2
    • /
    • pp.129-149
    • /
    • 1991
  • Circadian rhythm is entrained in the 24-hour time interval by periodic factors in the environment, known as zeitgeber. But most rotating work schedules are outside the range of the entrainment of the pacemaker timing the human circadian sleep - wake cycle. It has been postulated that physiological and emotional disturbances occur in most human functions when the circadian rhythm is disturbed. So application of circadian principles to the design of shift schedules can aid in maintaining the temporal integrity of the circadian system and thereby minimize for the shift worker any detrimental consequences of circadian disruption. This study was a quasi-experimental study to test the effect of shift intervals for the clinical nurse on the circadian rhythm. Twenty nurses newly employed in general units of two hospitals were selected as an experimental group and twelve college nursing students as a control group. Both groups were selected according to an established criteria using a purposive sampling technique. Ten subjects were assigned to a weekly shift group and another ten to a biweekly shift group engaged in a semi -continuous shift schedule(sunday off) with a backward direction, that is, morning -evening - night shift. The control group worked a morning shift for 42 days. Oral temperature rhythm, waking tim, sleep - wake cycle, fatigue, and mental performance were measured during the experimental period. The data collection period was from April 30, 1990 to June 10, 1990. MANOVA, paired t-test, ANOVA, and Student Newman Keuls method were used for statistical analysis. The results are summarized as follows. 1. Phase delay in the acrophase of temperature rhythm was shown according to the backward rotating shift. A complete adaptation to work on the night shift was achieved between the sixth and ninth day of the night shift. 2. There was no difference in either waking time or sleep- wake cycle according to the duration of the working day for every shift group. Significant difference was found in the waking time and the sleep -wake cycle for subjects on the morning, evening, and night shift in both of the shift groups(weekly shift group : λ=0.121, p<0.01, λ=0.112, p<0.01, biweekly shift group : λ=0.116, p<0.01, λ=0.084, p<0.01). 3. There was no difference in fatigue between the first working day and the last working day for the control group and for the biweekly shift group. In the weekly shift group, physical fatigue was significantly different for the first day and the sixth day of the night shift(t=-2.28, p<0.05). Physical fatigue and total fatigue on the first day of the night shift showed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=5.79, p<0.01, F=4.56, p<0.05). There was a significant difference between the shift groups and the control group(p<0.05), Physical fatigue, neurosensory fatigue and total fatigue on the last day of the night shift showed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=12.65, p<0.01, F=7.77, p<0.01, F=9.68, p<0.01). There was a significant difference between the shift groups and the control group(p<0.05). 4. No difference in mental performance was seen between the first day and the last day of work in each case. An arithmatic test on the first day of the night shift revealed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=3.79, p<0.05). There was a significant difference between the shift groups and the control group(p<0.05) . The digital symbol substitution test and the arithmetic test on the last day of the night shift showed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=3.68, p<0.05, F=5.55, p<0.01), and both showed a significant difference between the shift groups and the control group(p<0.05). Accordingly, this study showed that during night duty, the waking time, sleep- wake cycle, and fatigue increased and mental performance decreased compared with morning and evening duty. It was also found that the weekly shift group had a higher fatigue score on the sixth day of night duty as compared to the -first day, but the waking time, sleep- wake cycle, and mental performance revealed no difference for the duration of the night duty or between shift groups, and complete adaptation of temperature rhythm was achieved between the sixth and ninth day of night duty. It is possible to conclude from these results that for intermediate circadian type in a healthy young woman, a biweekly shift system is more compatible with the circadian timing system than weekly shift system.

  • PDF

Temperature Stable Time-to-Digital Converter (온도변화에 안정한 시간-디지털 변환 회로)

  • Choi, Jin-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.4
    • /
    • pp.799-804
    • /
    • 2012
  • To converter time information to digital information Time-to-Digital Converter(TDC) is designed by using analog delay elements. To obtain the temperature stable characteristics the circuit is designed and the operation of the designed circuit is confirmed by HSPICE. The characteristics variation of the designed delay element with temperature is from -0.18% to 0.126% compared to room temperature characteristics when the temperature is varied from $-20^{\circ}C$ tp $70^{\circ}C$. Time difference is from -0.18% to 0.12% compared to room temperature characteristic when the temperature is varied from $-20^{\circ}C$ tp $70^{\circ}C$. The time difference is simulated when the digital output is 15. However the time difference is from -1.09% to 1.28% in the TDC using temperature non-stable analog delay elements.

Design and Implement of BACnet based Intelligent Building Automation Control System (모바일 카메라를 이용한 방송 시스템 설계 및 구현)

  • Park, Youngha;Seong, Kiyoung;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.10
    • /
    • pp.1330-1336
    • /
    • 2021
  • Media sharing platform such as YouTube have grown significantly in the mobile environment. This is a platform that allows users to select and view broadcast programs that are only available on TV through network-connected PCs and mobiles, and share their media content to communicate. Currently, in the era where mobile and TV broadcasts can be viewed equally, there is a time difference between the video and real-time screen transmitted to TV and mobile, different from the actual situation.We want this time difference to be realized in the same way as the real time, and there is a need for a system that can broadcast in a free environment at any time. Therefore, in this paper, a broadcasting system was designed and implemented in a mobile environment. The result of reducing the delay time difference due to the improvement of the processing method was obtained.