• Title/Summary/Keyword: Tightness

Search Result 438, Processing Time 0.029 seconds

Establishing the Structural Criteria to install Scaffolding-Use Brackets (비계지지브라켓 유형별 구조기준 설정에 관한 실험적 연구)

  • Son, Ki-Sang;Kal, Won-Mo
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.4
    • /
    • pp.87-96
    • /
    • 1995
  • It is only three(3) years since we applied brackets for scaffolding in the construction area. Unfortunately, there is no structural criteria on how to install those in the site so far, despite the fact that those brackets have been applied into the site by the firms already. It is shown that resistant capacity of each bracket type has been investigated, analyzed from this experimental study. Accident-concerning data on construction site analyzed by the Ministry of Labor, show temporary structure involves 18.6% of the total industrial accident, which the accidents from scafold-supporting brackets have rate of 42.5% of the ones occurred from the temporary structures. There are two main aspects to be observed : one is how much resistant capacity the brackets have themselves, the other is how exactly to install those without eccentricity. But practically, nobody does check of this bolt-installing conditions in the site and no check of tightening level of nut because there is no available tool to check torque amount for this kind of nut. We just have to rely on scaffolders experience of this tightening. This experiment involves just this variable of tightness at site. Eventually this insufficient tightness causes to collapse those scaffolding structures. The bracket might have less the one than its original capacity due to this insufficient tightness. Three(3) times of PIVOT tests show that fractured condition of two(2) row brackets has occurred mostly at lower bolt due to shear force. Therefore, tightness of bracket-installing bolt, tensile strength of the bolt, shear strength of the bolt, loading condition with equal two point or inequal two point loads, are mainly investigated as variables in this study.

  • PDF

The Effectiveness of Evjenth-Hamberg Stretching with regards to Muscle Tone and Flexibility in Adults with Hamstring Tightness (에비안스-함베르크 스트레칭이 뒤넙다리근 단축이 있는 성인의 근긴장도 및 유연성에 미치는 영향)

  • Do, Hyun-Ho;Chon, Seung-Chul
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.15 no.4
    • /
    • pp.111-119
    • /
    • 2020
  • PURPOSE: In adults with hamstring tightness, stretching is considered a therapeutic exercise that improves flexibility. However, previous studies have reported efficacy of numerous methods, and are inconclusive in determining the most effective stretching techniques. This study aims to compare the outcomes of Evjenth-Hamberg stretching (E-HS), proprioceptive neuromuscular facilitation stretching (PNFS), and static stretching (SS), on muscle tone and flexibility. METHODS: A total of 30 subjects were assigned to each of the three stretching groups:; E-HS (n1 = 10), PNFS (n2 = 10), and SS (n3 = 10). Muscle tone of the hamstring muscle, active knee extension (AKE), and passive knee extension (PKE) were assessed by range of motion. RESULTS: After the intervention, statistically significant differences were obtained between groups for muscle tone (p < .05). The post hoc test, showed statistically significant differences in muscle tone between the E-HS and PNFS groups (p < .05), and PNFS and SS groups (p < .05). Post hoc test after intervention, also revealed statistically significant differences in flexibility (p < .05) between the E-HS and PNFS groups (p < .05), E-HS and SS groups (p < .05), and PNFS and SS groups (p < .05). Moreover, a statistically significant difference was observed in PKE scores between the E-HS and SS groups (p < .05), and PNFS and SS groups (p < .05). CONCLUSION: This study indicates that E-HS may be the most effective stretching technique for muscle tone and flexibility, in adults with hamstring tightness.

A Study on the Enhance of Air tightness Performance of a New Type Silding Window with horizontally Rolling Wheels (수평 구름 바퀴가 적용된 신 유형 미서기 창문의 기밀성능 개선에 관한 연구)

  • Jang, Hyok-Soo;Kim, Young-Il;Chuung, Kwang-Seop
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.63-70
    • /
    • 2015
  • Crevices between window and window frame cause not only heat losses but also serve path to sound transmission and infiltration of fine dusts that are harmful to humans. There were many efforts in the past to eliminate these crevices but because of the windows' indispensable function of opening and closing, it was an unsolvable problem. In this study, a new type sliding window is developed by applying horizontally rolling wheels to implement a surface sealing which is excellent for enhancing air tightness. To evaluate the feasibility of the newly developed window, forces for opening and closing, durability and air tightness were testet according to Korean Testing Standards. Force for opening a 2000 N window is 30 N. It endured 100,000 cycles of opening and closing. Infiltration was $0.00m^3/(m^2h)$ for a pressure difference of 10 Pa. Since this window has few moving parts, it has favorable features of low cost and few breakdown.

The Field Measurement of Airtightness in the Apartment Buildings (신축공동주택의 기밀성능 실측에 관한 연구)

  • Park, Won seok;Yoon, Jae Ock
    • KIEAE Journal
    • /
    • v.3 no.3
    • /
    • pp.43-50
    • /
    • 2003
  • Nowdays the apartment is a main type of modernized residential buildings. According to the improvement of construction techniques and functions of windows and doors, recent apartments are enhanced air tightness of windows, doors and building envelopes. As Infiltration is decreased and natural ventilation is reduced, energy could be saved in winter. However, indoor air quality is bad. The air Infiltration of a building could be enlarged by physical actions, such as building designs, constructions and reduction of air tightness which is caused by aging. This research analyzes and measures with KNS-4000P (Sapporo air tightness measurement) the air tightness of the high rise apartments which is recently constructed and not occupied yet. With depressurization method, the KNS-4000 installed on the window and the indoor air-leakage was measured. At that time, Air come out from the edge of the windows and doors because of the pressure differences between indoor and outdoor. We measure the amount of the air as effective air leakage areas. This method of depressurization takes less time to measure than other methods and is less affected from other conditions. We measured infiltration of total 56 household, 29 households S apartment (total floor area : $64.42m^2$) in Balan and 29 households D apartment(total floor area : $78.21m^2$) in Chonan. As a result of the field measurements at October 2003, normalized leakage area of D apartment in Cheonan was $2.05cm^2/m^2{\sim}3.49cm^2/m^2$ (average: $2.77cm^2/m^2$) and normalized leakage area of S apartment in Balan is $1.23cm^2/m^2{\sim}1.68cm^2/m^2$ (average: $1.5cm^2/m^2$).

Radiologic Outcome of Beta-Tricalcium Phosphate as a Bone Substitute in Orthopaedic Surgery (정형외과 수술에서 골대체제로써 Beta-Tricalcium Phosphate 사용에 대한 방사선학적 결과)

  • Park, Hyungseok;Moon, Jeong Eun;Cho, Yong Jin
    • The Korean Journal of Health Service Management
    • /
    • v.13 no.4
    • /
    • pp.133-144
    • /
    • 2019
  • Objectives: To analyze the radiologic results of patients treated with bone defects treated with beta-tricalcium phostphate (β-TCP) in orthopedic surgery. Methods: Medical records of 49 patients, consisting of 24 (49.0%) men and 25 (51.0%) women were retrospectively reviewed. Graft incorporation was evaluated based on Irwin's radiologic staging. Results: The explanatory power of the total regression equation in Irwin's stage at 3 months postoperatively according to three explanatory variables, namely graft tightness, age at diagnosis, and lesion volume, was 65.6%; the explanatory power of Irwin's stage at 6 months postoperatively according to two variables, namely lesion volume and graft tightness, was 32.9%; and the explanatory power of Irwin's stage at 9 months postoperatively for two variables, namely longitudinal lesion length and graft tightness in the total regression, was 30.8%. Conclusions: Graft tightness, lesion volume, age at diagnosis, and longitudinal lesion length are the common factors affecting graft incorporation.

An Experimental Study on the Water Tightness of Fly Ash Antiwashout Underwater Concrete (플라이애시 수중불분리성 콘크리트의 수밀성에 관한 실험적 연구)

  • Kwon, Jung-Hyun;Kim, Bong-Ik
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.4
    • /
    • pp.40-45
    • /
    • 2008
  • This paper describes the effects of fly ash replacement on the water tightness of antiwashout underwater concrete, which replaced the cement with fly ash from 0% to 30%. The experimental work was performed to find out the depth of permeation of concrete specimens cast in air and cured in 23 $^{\circ}C$ tap water using an open center pressure type of water permeation tester. The results showed that the permeation depth values of antiwashout underwater concrete were deeper than normal concrete, but that an admixture using fly ash during antiwashout underwater concrete casting in air made it more watertight than normal concrete according to the water permeation testing. SEM observations of the specimens of fly ash antiwashout underwater concrete showed that it wasmore packed with structures because of the pozzolan reaction of the fly ash and cement.

Water Tightness around Under-ground Oil Storage Cavern (지하유류비축공동(地下油類備蓄空洞)의 수밀성(水密性)에 관한 연구(硏究))

  • Chung, Hyung Sik;Sun, Yong;Kim, Oon Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.2 no.4
    • /
    • pp.33-38
    • /
    • 1982
  • A successful operation of underground oil storage cavern depends on water-tightness around cavern by groundwater. If water-tightness is not secured, gas bubbles would leak out and oil would migrate to an adjacent empty cavern. In this research an electrical analogy method was employed to study the influence of shape of cavern on gas leakage and the required natural groundwater level, relative oil level in two neighboring caverns and cavern spacing to prevent oil migration. The results show that gas leakage is prevented from a cavern with a ceiling of large curvature. The required values of factors to curtail the migration of oil are given on a graph.

  • PDF

A Study on the Alkaline treatment of Polyester Fabric - The effect of correlation with the physical, sensory properties and handle- (폴리에스테르 직물의 알칼리가공에 관한 연구 -물리량, 관능량과 태와의 상호관계를 중심으로-)

  • Jeong Je Seok
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.10 no.3
    • /
    • pp.9-16
    • /
    • 1986
  • In this research, we tested the fertile physical and the sensory properties and the handle of the domestic polyester fabrics were treated with the varying alkaline concentrations and temperatures were tested. The tests were conducted to determine the effects of the alkaline treatment on the changes of the physical and the sensory chrateristics of the domestic polyester fabrics. The results were as follows; 1. When treated with the varying alkaline concentrations from $7.5\%$ to $15\%$ at temperatures from $60^{\circ}C$ to $90^{\circ}C$, the weight decreasing phenomena were shown to as a linear equations increase in that range. 2. As the weight loss increased, the softness and the smoothness were increased but the fullness and the tightness were decreased. 3. The positive correlations were found between the sensory and the physical properties, and the fullness ana the tightness, while a negative correlation was found between softness and the smoothness. 4. The regression equations obtained by the sensory chrateristics related with the physical chracteristics were as follows ; Softness: y=84.01-0.74x Fullness : y=0.06+0.78x Smoothness: y=88.67-0.82x Tightness : y= 0.34+0.79x

  • PDF

Densification and Electrical Conductivity of Plasma-Sprayed (Ca, Co)-Doped LaCrO3 Coating (플라즈마 스프레이 (Ca, Co)-Doped LaCrO3 코팅층의 치밀화 및 전기전도도)

  • Park, Hee-Jin;Baik, Kyeong-Ho
    • Korean Journal of Materials Research
    • /
    • v.27 no.3
    • /
    • pp.155-160
    • /
    • 2017
  • Doped-$LaCrO_3$ perovskites, because of their good electrical conductivity and thermal stability in oxidizing and/or reducing environments, are used in high temperature solid oxide fuel cells as a gas-tight and electrically conductive interconnection layer. In this study, perovskite $(La_{0.8}Ca_{0.2})(Cr_{0.9}Co_{0.1})O_3$ (LCCC) coatings manufactured by atmospheric plasma spraying followed by heat treatment at $1200^{\circ}C$ have been investigated in terms of microstructural defects, gas tightness and electrical conductivity. The plasma-sprayed LCCC coating formed an inhomogeneous layered structure after the successive deposition of fully-melted liquid droplets and/or partially-melted droplets. Micro-sized defects including unfilled pores, intersplat pores and micro-cracks in the plasma-sprayed LCCC coating were connected together and allowed substantial amounts gas to pass through the coating. Subsequent heat treatment at $1200^{\circ}C$ formed a homogeneous granule microstructure with a small number of isolated pores, providing a substantial improvement in the gas-tightness of the LCCC coating. The electrical conductivity of the LCCC coating was consequently enhanced due to the complete elimination of inter-splat pores and micro-cracks, and reached 53 S/cm at $900^{\circ}C$.

Application of A Discrete Fracture Flow and Mass Transport Simulation Technique Assessing Tightness Criteria for Underground LPG Storage Cavern (지하 LPG 저장공동의 기밀성평가를 위한 분리열극개념의 지하수유동 및 용질이동 모형 모의기법 적용)

  • 한일영;조성만;정광필
    • The Journal of Engineering Geology
    • /
    • v.5 no.2
    • /
    • pp.155-165
    • /
    • 1995
  • Fluid flow studies of fractured rocks require three-dimensional modeling of the fracture system. The stochastic discrete fracture models constructed by Monte Carlo simulation technique were applied to the analysis of groundwater flow and mass transport in fractured rock for the assessment of tightness criteria of underground LPG storage cavern. The parameters that most affect the conceptual discrete fracture modeling proved either fracture orientation or size and on the fract'lre flow interpretation proved conductive fracture intensity. The fracture transmissivity played important role in solute transport in fractured rock simulated by particle tracking approach. It was partly recognized that the calibrated stochastic discrete fracture model can be used for the tightness criteria of underground LPG storage cavern.

  • PDF