• 제목/요약/키워드: Tightening Torque

검색결과 92건 처리시간 0.024초

A comparative study of gold UCLA-type and CAD/CAM titanium implant abutments

  • Park, Ji-Man;Lee, Jai-Bong;Heo, Seong-Joo;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.46-52
    • /
    • 2014
  • PURPOSE. The aim of this study was to evaluate the interface accuracy of computer-assisted designed and manufactured (CAD/CAM) titanium abutments and implant fixture compared to gold-cast UCLA abutments. MATERIALS AND METHODS. An external connection implant system (Mark III, n=10) and an internal connection implant system (Replace Select, n=10) were used, 5 of each group were connected to milled titanium abutment and the rest were connected to the gold-cast UCLA abutments. The implant fixture and abutment were tightened to torque of 35 Ncm using a digital torque gauge, and initial detorque values were measured 10 minutes after tightening. To mimic the mastication, a cyclic loading was applied at 14 Hz for one million cycles, with the stress amplitude range being within 0 N to 100 N. After the cyclic loading, detorque values were measured again. The fixture-abutment gaps were measured under a microscope and recorded with an accuracy of ${\pm}0.1{\mu}m$ at 50 points. RESULTS. Initial detorque values of milled abutment were significantly higher than those of cast abutment (P<.05). Detorque values after one million dynamic cyclic loadings were not significantly different (P>.05). After cyclic loading, detorque values of cast abutment increased, but those of milled abutment decreased (P<.05). There was no significant difference of gap dimension between the milled abutment group and the cast abutment group after cyclic loading. CONCLUSION. In conclusion, CAD/CAM milled titanium abutment can be fabricated with sufficient accuracy to permit screw joint stability between abutment and fixture comparable to that of the traditional gold cast UCLA abutment.

소성역체결 볼트의 체결력과 마찰계수에 관한 연구 (Study on the Clamping Force and the Friction Coefficient in a Bolt tightened up to the Plastic Range)

  • 손승요;신근하
    • 전산구조공학
    • /
    • 제7권3호
    • /
    • pp.133-141
    • /
    • 1994
  • 강도활용을 극대화한 볼트의 소성역체결시 볼트의 항복은 볼트에 발생한 인장응력과 너트 나사산과의 접촉면에서 오는 마찰토오크에 의한 전단응력과의 조합에 의한 영향을 받는다. 볼트는 최소단면적인 나사부중 너트와 물리지 않은 여우나사부에서 먼저 항복을 일으킨다. 볼트재료는 대체로 항복과 더불어 소성경화를 보이며 그 정도는 고강도재료에서 인장강도의 10%정도이다. 본 연구에서는 소성역체결시의 거동해석을 변형도증분이론에 의거 해석하였다. 항복은 최소단명이 원통의 표면에서 시작되며 이를 두께가 얇은 원통으로 취급하였다. 항복의 전파는 이들 얇은 원통이 체결이 진행됨에 따라 순차적으로 항복에 이르는 것으로 보고 이 얇은 원통들을 항복시키는데 필요한 축력과 토오크를 합하여 체결종료시의 볼트축력과 (나사면마찰) 토오크로 하였다. M10미터 가는 나사를 계산과 실험에 사용하였다. 축력과 마찰토오크의 마찰계수에 대한 변화관계를 보여주는 그래프와 더불어 실험에서 사용한 볼트의 설계보조 선도를 제시하였다. 이 설계보조용 선도는 실험실에서 얻어진 토오크계수와 마찰계수와의 관계를 그린 것으로 윤활, 포면처리등 현장조건에 따라 달라진 마찰계수를 적절히 취급하는데 효과적으로 활용이 가능하다.

  • PDF

MW급 풍력발전기 동력전달용 테이퍼 연결장치 설계에 관한 연구 (Tapered Joint Design for Power Transmission of MW-grade Wind Turbine)

  • 강종훈;배준우;온한용;권용철
    • 대한기계학회논문집A
    • /
    • 제39권11호
    • /
    • pp.1183-1189
    • /
    • 2015
  • 본 연구는 풍력발전기용 동력 전달부품의 테이퍼 연결장치 설계에 관한 것이다. 요구되는 전달토크의 크기, 동력을 전달하는 축의 직경, 테이퍼 링의 접촉면적 그리고 압축 면압을 부과하기 위한 볼트의 체결력 등이 테이퍼 연결장치 설계의 주요 변수이다. 테이퍼 연결의 계산은 축대칭 평면 변형률 조건의 복합링 구조로 가정하여 응력과 변형량을 계산 하였다. 축에 작용하는 면압은 요구 전달동력을 이용하여 계산하였고, 보강링에 작용하는 면압은 축과 허브의 변형량 일치 조건을 이용하여 계산하는 방법을 제안하였다. 복합링의 수식으로 구한 반경방향의 변형량으로 테이퍼 각도를 고려한 축방향 습동거리를 계산하였다. 수식으로 구한 응력과 상대습동거리의 타당성을 검증하기 위하여 유한요소해석을 수행하였으며 축방향의 하중이 발생하는 테이퍼면에서 원주방향의 응력이 최대 10% 수준의 오차를 보이고 있으나 그 외 응력분포와 상대습동거리는 수식적인 방법과 해석적인 방법이 일치함을 확인하였다.

내부 원추형 연결형태 임플란트에서 지대주 나사머리의 좌면각도가 연결부 기계적 안정성에 미치는 영향 (Influence of bearing surface angle of abutment screw on mechanical stability of joint in the conical seal design implant system)

  • 김주현;허중보;윤미정;강은숙;허재찬;정창모
    • 구강회복응용과학지
    • /
    • 제30권3호
    • /
    • pp.206-214
    • /
    • 2014
  • 목적: 내부 원추형 연결형태 임플란트에서 지대주 나사의 좌면각도가 연결부의 기계적 안정성에 미치는 영향을 알아보기 위함이다. 연구 재료 및 방법: 원추형 연결구조 티타늄 임플란트와 시멘트 유지형 지대주, 텅스텐 카바이드 코팅된 티타늄 합금 지대주 나사를 사용하였다. 좌면각도가 $45^{\circ}$$90^{\circ}$를 갖는 지대주와 지대주 나사를 제작하여 30 Ncm 조임회전력으로 지대주를 체결한 후 하중을 가하고 체결 및 하중 부여에 따른 침하량을 측정하였다(n = 5). 유압식 피로시험기에 임플란트를 고정하고 스테인리스 스틸 금속관을 지대주에 합착하였다. 이 후 반복 하중을 가한 후 풀림토크 변화량을 측정하고, 압축굽힘강도와 피로강도를 측정하였다(n = 5). 결과: 지대주 침하량은 지대주나사 체결 시 가장 크게 나타났으며(P < 0.05), 나사체결과 하중부여에 따른 총 침하량은 $45^{\circ}$군보다 $90^{\circ}$군에서 더 크게 측정되었다(P < 0.05). 반복하중 부여 후 풀림 토크, 그리고 최대 압축굽힘강도와 피로강도는 통계적으로 유의한 차이를 보이지 않았다(P > 0.05). 결론: 본 실험조건하에서 지대주 나사머리의 원추형 설계가 지대주의 총 침하량을 약간 감소시키는 효과를 나타냈으나, 연결부의 전체적인 기계적 안정성에 미치는 영향은 크지 않을 것으로 판단된다.

THE EFFECT OF ABUTMENT HEIGHT ON SCREW LOOSENING IN SINGLE IMPLANT-SUPPORTED PROSTHESES AFTER DYNAMIC CYCLIC LOADING

  • Kim Nam-Gun;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • 대한치과보철학회지
    • /
    • 제42권6호
    • /
    • pp.664-670
    • /
    • 2004
  • Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection. Purpose. The purpose of this study was to examine the changes of detorque values of abutment screws with external connection in different abutment heights. Materials and methods. After cyclic loading on three different abutment heights, detorque values were measured. Abutments were retained with titanium abutment screws tightened to 30 Ncm (30.5 kgmm) with digital torque gauge as recommended by the manufacturer. Replacing abutments, implants and titanium abutment screws with new ones at every measurement, initial detorque values were measured six times. In measuring de torque values after cyclic loading, Avana Cemented Abutments of 4.0 mm collar, 7.0 mm height (Osstem Co., Ltd., Seoul, Korea) were used with three different lengths of 5.0, 8.0, 11.0 mm. Shorter abutments were made by milling of 11.0 mm abutment to have the same force-exercised area of 4.5 mm diameter. Sine curve force (20N-320N, 14Hz) was applied, and detorque values were measured after cyclic loading of 2 million times by loading machine. Detorque values of initial and after-loading were measured by digital torque gauge. One-way ANOVA was employed to see if there was any influence from different abutment heights. Results. The results were as follows: 1. The initial detorque value was 27.8$\pm$0.93 kgmm, and the ratio of the initial detorque value to the tightening torque was 0.91(27.8/30.5). 2. Measured detorque values after cyclic loading were declined as the height of the abutment increased, that was, 5.0 mm; 22.3$\pm$0.82 kgmm, 8.0 mm; 21.8$\pm$0.93 kgmm, and 11.0 mm; 21.3$\pm$0.94 kgmm. 3. One-way ANOVA showed no statistically significant differences among these (p>0.05). 4. Noticeable mobility at the implant-abutment interface was not observed in any case after cyclic loading at all.

유한요소법을 이용한 치과 임플란트 고정체의 직경과 길이에 따른 지지골의 응력 분석 (Finite element analysis on the stress of supporting bone by diameters and lengths of dental implant fixture)

  • 이명곤
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.151-156
    • /
    • 2016
  • Purpose: The dental implant should be enough to endure chewing load and it's required to have efficient design and use of implant to disperse the stress into bones properly. This study was to evaluate the stress distribution on a supporting bone by lengths and diameters of the implant fixture. Methods: The modeling and analysis of stress distribution was used for the simple molar porcelain crown model by Solidworks as FEM program. It was designed on applying with tightening torque of 20 Ncm of a abutment screw between a cement retained crown abutment and a fixture. The fixtures of experimental model used 10, 13mm by length and 4, 5mm by diameter. A external vertical loading on the two buccal cusps of crown and performed finite element analysis by 100 N. Results: The maximum von Mises stress(VMS) of all supporting bone models by fixture length and diameter were concentrated on the upper side of supporting compact bone. The maximum stress of each model under vertical load were 164.9 MPa of M410 model, and 141.2 MPa of M413 model, 54.3 MPa of M510 model, 53.6 MPa of M513 model. Conclusion: The stress reduction was increase of fixture's diameter than it's length. So it's effective to use the wider fixture as possible to the conditions of supporting bone.

막구조 정착부의 볼트접합부 막재료의 신장 및 파단상태를 통한 응력전달체계에 관한 연구 (Study on stress transition mechanism by tensile and fracture characteristics of membrane material at bolting part in clamping part of membrane Structures)

  • 김희균;심천보;김재열
    • 한국공간구조학회논문집
    • /
    • 제23권4호
    • /
    • pp.97-105
    • /
    • 2023
  • The membrane structure should maintain the membrane materials in tension for structural stability guaranty. The anchoring part in the membrane structure is an important part. It has the function to introduce tension into membrane materials and function to transmit stress which membrane materials receives to boundary structure such as steel frames. In this paper, it grasps anchoring system of the anchoring part in the membrane structure concerning the fracturing characteristic condition of membrane structure, and the influence which is caused to yield it designates the stress state when breaking the membrane structure which includes the anchoring part and that stress transition mechanism is elucidated as purpose. This paper follows to previous paper, does 1 axial tensile test concerning the bolting part specimen, grasp of fracturing progress of the bolting part and the edge rope and hardness of the rubber, does the appraisal in addition with the difference of bolt tightening torque. As a result, the influence which the bolt anchoring exerts on the fracturing characteristics of the membrane material in the membrane structure anchoring part is examined.

지르코늄 임플란트 지대주의 나사결합부 안정성에 관한 연구 (Screw Joint Stability under Cyclic Loading of Zirconia Implant Abutments)

  • 이미순;서규원;류재준
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.164-173
    • /
    • 2009
  • 연구 목적: 심미적 장점을 지닌 지르코니아 지대주와 금속 지대주 사이에 반복 하중 전, 후의 풀림 회전력을 비교하여 지대주 재질에 따른 나사 안정성에 차이가 있는지를 비교 분석해 보고자 하는 것이다. 연구 재료 및 방법: 실험군은 크게 외측 연결 구조(US II, Osstem Implant, Korea)와 내측 연결 구조(GS II, Osstem Implant, Korea)의 임플란트 시스템을 두 군으로 나누었다. 각각의 군에서 지르코니아 지대주군와 금속 지대주군으로 나누어 실험하였다. 각군당5개씩의 시편을 제작하였다. 임플란트 고정체를 별도 제작된 지그에 고정시킨다. 디지털 토크게이지를 이용하여 30 Ncm의 조임 회전력을 가하고 10분 후 동일 조임 회전력을 한번 더 적용하였다. 다음 각 지대주 나사의 초기 풀림 회전력을 디지털 토크게이지로 측정하였다. 동일 시편을 다시 30 Ncm의 조임 회전력을 가하여 체결한 후, 유압식 동적 재료시험기(Instron, USA)에 임플란트 매식체를 치과용 임플란트 피로시험에 관한 ISO/FPIS 14801:2003(E)규정을 참고하여 고정시켰다. 최소 하중은 10 N, 최대 하중은 250 N의 sine형 반복 하중을 $30^{\circ}$의 경사각도로, 하중 주기는 14 Hz로, 100만 회의 반복 하중을 적용한 후 풀림 회전력을 측정하였다. 결과: 1. 모든 시스템에서 지대주 나사의 풀림 회전력이 조임 회전력 보다 감소하였으나, 나사 풀림 현상은 나타나지 않았다. 2. 반복 하중 전과 후의 나사 풀림 회전력은 두 임플란트 시스템 모두에서 지르코니아 지대주가 금속 지대주보다 더 컸다(P<.05). 3. 반복 하중에 따른 풀림 회전력 상실률은 두 임플란트 시스템 모두에서 지르코니아 지대주와 금속 지대주가 차이가 없는 것으로 나타났다(P>.05). 4. 금속 지대주에서 반복 하중에 따른 풀림 회전력 상실률은 내측 연결 형태의 GS II 시스템이 외측 연결형태의 US II 시스템보다 작았다(P<.05). 5. 지르코니아 지대주에서는 반복 하중에 따른 풀림 회전력 상실률은 두 임플란트 시스템 간에 차이가 없는 것으로 나타났다(P>.05). 결론: 본 실험을 통해 100만회 반복 하중 하에서 지르코니아 지대주가 금속 지대주에 비해 나사 결합부 안정성이 더 크다는 결론을 내릴 수 있다.

원추형 연결 임플란트에서 지대주 종류에 따른 나사풀림과 침하현상에 관한 연구 (Effect of various abutment systems on the removal torque and the abutment settling in the conical connection implant systems)

  • 이진선;이준석
    • 대한치과보철학회지
    • /
    • 제50권2호
    • /
    • pp.92-98
    • /
    • 2012
  • 연구 목적: 본 연구 목적은 서로 다른 재료로 제작된 지대주를 이용하여 동적하중을 가했을 때 풀림토크와 침하량에 대한 임플란트-지대주 연결부의 안정성에 대하여 알아보는 것이다. 연구 재료 및 방법: 원추형 내부연결 구조를 갖는 임플란트에 이용되는 세 가지 지대주, 티타늄 합금 지대주(Cement abutment, Osstem Co., Seoul, Korea), 귀금속 UCLA 지대주(UCLA Goldcast abutment, Osstem Co., Seoul, Korea), 비귀금속 UCLA 지대주(CCM Metalcast abutment, 3M ESPE, Seefeld, Germany)를 사용하였다. 귀금속 UCLA 지대주와 비귀금속 UCLA 지대주를 티타늄 지대주와 유사한 형태로 납형을 형성 한 후 각각 제 3형 금합금(E-3, Heesung catalyst Co., Seoul, Korea)와 니켈-크롬 합금인(Rexillium $III^{(R)}$, $Pentron^{(R)}$, San Diego, USA)를 사용하여 주조 하였다. 임플란트와 지대주를 디지털 토크 컨트롤러를 이용하여 30 N cm로 체결하였고 전하중 상실을 보상하기 위하여 10분 후 다시 같은 힘으로 체결 하였다. 디지털 토크 게이지를 사용하여 풀림토크를 측정하였고 디지털 마이크로미터를 이용하여 임플란트/지대주 길이를 측정하였다. 그 후 동적 하중 피로 시험기에 지대주를 장착한 후 최대 250 N, 최소 25 N, 주기 14 HZ의 sine형의 하중을 장축과 평행하게 가하였다. 하중 후 임플란트/지대주의 길이를 재측정 하고, 전후 길이변화량을 이용하여 침하량을 계산하였으며 풀림토크를 측정하였다. 결과: 하중 전후의 길이를 비교하였을 때 세 군 모두에서 유의한 차이를 보였다($P$<.05). 군 간의 침하량을 비교하였을 때 통계적으로 유의한 차이를 보이지는 않았다. 하중 전후의 풀림토크를 비교하였을 때 역시 세 군 모두에서 유의한 차이를 보이며 감소하였다 ($P$<.05). 하중 전 풀림토크와 하중 후 풀림토크를 군간 비교하였을 경우에는 통계적으로 유의한 차이를 보이지는 않았다. 결론: 원추형 내부 연결구조를 갖는 임플란트에서 동적하중은 임플란트의 침하량과 풀림토크에 영향을 미치는 것으로 보이나 지대주간 차이는 나타나지 않았다. 비귀금속UCLA 지대주이 사용은 귀금속 UCLA 지대주와 마찬가지로 기능적 하중에서 안정적일 것으로 사료된다.

볼트 수직이음 PHC말뚝와 용접이음 PHC말뚝의 이음부 거동 비교 (Comparison of Splices between Bolts and Welding Spliced PHC Piles)

  • 김명학;최용규
    • 한국지반공학회논문집
    • /
    • 제34권12호
    • /
    • pp.93-103
    • /
    • 2018
  • 볼트 수직이음 PHC말뚝 및 용접이음 PHC말뚝에 대한 휨강도시험을 실시하여 각 이음 PHC말뚝의 성능을 비교 분석하였다. $200N{\cdot}m$이상의 토크치로 체결한 볼트 수직이음 PHC말뚝에서는 가장 낮은 하중단계인 20kN에서도 볼트 수직이음구에서 좌우로 꺾인 변형 양상(직선 v형 라인)이 나타났으며 PHC말뚝 본체는 완전한 직선 형태를 유지하고 있었으므로 볼트 수직이음 PHC말뚝은 말뚝의 가장 중요한 성능인 일체화 거동을 하지 않았다. 체결토크가 풀린 즉, $20N{\cdot}m$의 토크치로 체결한 볼트 수직이음 PHC말뚝은 각 하중 단계에서 이음부위에 대하여 양쪽으로 대칭된 직선 V형 상태의 변위 양상을 나타내고 있었다. 각 하중 단계에서 하중 제거 시 이음말뚝은 하중 재하 전의 상태로 돌아가지 않았으므로 탄성 재료 거동을 나타내지도 않았다. 재하단계에 따른 이음부 변위 및 재하 하중 제거 후의 잔류 변위, 이음 PHC말뚝의 파괴하중 및 3가지 기본 성능 등을 비교한 결과 볼트 수직이음 PHC말뚝의 이음 품질은 용접이음 PHC말뚝의 이음 품질에 크게 미달하였다. 따라서 $200N{\cdot}m$ 이상의 토크치로 체결한 볼트 수직이음 PHC말뚝이나 체결토크가 풀린 볼트 수직이음 PHC말뚝은 이음말뚝의 기본 성능에 크게 미달하는 것으로 나타났다.