• 제목/요약/키워드: Ti-6AL-4V

검색결과 478건 처리시간 0.029초

Assessment of titanium alloy bolts for structural applications

  • Li, Dongxu;Uy, Brian;Wang, Jia;Song, Yuchen
    • Steel and Composite Structures
    • /
    • 제42권4호
    • /
    • pp.553-568
    • /
    • 2022
  • This paper explored the viability of utilising titanium alloy bolts in the construction industry through an experimental programme, where a total of sixty-six titanium alloy (Ti/6Al/4V) bolts were tested under axial tension, pure shear and combined tension and shear. In addition, a series of Charpy V-notch specimens machined from titanium alloy bolts, conventional high-strength steel bolts, austenitic and duplex stainless steel bolts were tested for impact toughness comparisons. The obtained experimental results demonstrated that the axial tensile and pure shear capacities of titanium alloy bolts can be reasonably estimated by the current design standards for steel structures (Eurocode 3, AS 4100 and AISC 360). However, under the combined tension and shear loading conditions, significant underestimation by Eurocode 3 and unsafe predictions through AS 4100 and AISC 360 indicate that proper modifications are necessary to facilitate the safe and economic use of titanium alloy bolts. In addition, numerical models were developed to calibrate the fracture parameters of the tested titanium alloy bolts. Furthermore, a design-based selection process of titanium alloy bolts in the structural applications was proposed, in which the ultimate strength, ductility performance and corrosion resistance (including galvanic corrosion) of titanium alloy bolts was mainly considered.

척추교정 티타늄 앵커나사 파단 손상원인 분석 (Failure Analysis of Ti alloy Screws in Fixing Fractured Spines)

  • 최병학;김문규;김승언;심윤임;이영진;정효태;최원열
    • 대한금속재료학회지
    • /
    • 제49권12호
    • /
    • pp.983-988
    • /
    • 2011
  • Failure analyses of the screws in spinal fixation devices were carried out. The fractured screws were retrieved from a patient who had spinal surgery in the thoracic vertebrae from number 10 to 15. The failure occurred one month after the removal of the braces. Microstructures and fracture surfaces were examined by optical and scanning electron microscopy. The microstructures of the screws corresponded to annealed Ti-6Al-4V bar. However, in the vicinity of the screw surface, there was an insufficient number of fine precipitates. Fracture surfaces showed typical fatigue failure modes. Regarding the fact that no machining defects were detected, fatigue crack initiation might have been caused by the lack of precipitates near the screw surfaces. Only the fourth of five fixed screws was severely stress-concentrated by the action of the spinal bones, while the stress of the 4th screw was decreased to half of its acceptable level when the screw was supplemented by one more, which might have been fixed in the 6th vertebra under the 5th position by the switching of its position. The stress simulation was conducted by ANSYS with 3D CAD of PRO/E in order to understand the stress concentration behavior and to provide an effective spinal surgery guide.

조직학과 효소활성 방법을 이용한 순 타이타늄과 타이타늄 합금의 상대적인 생체적합성 평가 (Relative Evaluation for Biocompatibility of Pure Titanium and Titanium Alloys using Histological and Enzymatic Methods)

  • 염동성;김병일;이유미;이은정;이성태;성치남;서권일;조현욱
    • Toxicological Research
    • /
    • 제23권4호
    • /
    • pp.331-339
    • /
    • 2007
  • Titanium or titanium alloy is a widely used implant material according to its certified biocompatibility, sufficient strength and ready availability. The purpose of this study was to evaluate the relative biocompatibility of titanium and titanium alloy specimens (Ti-29Nb-13Ta, TiNb and Ti-6Al-4V, Ti64) using in vivo and in vitro methods. For in vivo experiment, the specimens were implanted in the abdominal subcutaneous region of female mice for 2 and 4 weeks. The reaction of connective tissue to specimens was evaluated histologically. The specimens were encapsulated by fibrous connective tissue consisting of fibroblast, fibrocyte and other cells including neutrophil, macrophage, giant multinucleated cell and unidentified cells. Some newly formed blood vessels were located in the fibrous capsule surrounding the implant. Cell types and the thickness of fibrous capsules were examined quantitatively. Most of cell types located in the fibrous capsule were fibroblasts and fibrocytes. The average thickness of fibrous capsules for the TiNb specimens was much thinner than that of the titanium alloy, Ti64. The thickness of the fibrous capsule around all titanium specimens decreased at 4 weeks compared to 2 weeks post-implantation. The biocompatibility of titanium and titanium alloy specimens were also investigated in in vitro method using alkaline phosphatase from MG-63 cells. Alkaline phosphatase activity of the TiNb specimen showed higher activity than the titanium alloy, Ti64. In conclusion, the TiNb alloy with thin capsule thickness in vivo and high alkaline phosphatase activity in vitro will be of considerable use in biomedical applications.

Friction, Wear and Adhesion of HVOF Coating of Co-alloy Powder

  • Cho, Tong-Yul;Yoon, Jae-Hong;Song, Ki-Oh;Joo, Yun-Kon;Fang, Wei;Zhang, Shihong;Youn, Suk-Jo;Chun, Hui-Gon;Hwang, Soon-Young
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2007년도 추계학술대회 논문집
    • /
    • pp.61-62
    • /
    • 2007
  • HVOF thermal spray coating of micron size Co-alloy powder has been studied for the durability improvement of high velocity spindle (HVS). Optimal coating process of this system for the best surface properties is hydrogen flow rate 75 FMR, oxygen flow rate 38-42 FMR, feed rate 30 g/min at spray distance 5 inch. Friction coefficient (FC) and wear trace (WT) decrease increasing coating surface temperature from 25$^{\circ}$C to 538$^{\circ}$C due to the higher lubricant effects of the oxides at the higher temperature. At the study of adhesion of T800 coating on a light metal alloy Ti-6Al-4V (Ti64) tensile bond strength (TBS) and tensile fracture location (TFL) of Ti64/T800 are 8,740 psi and near middle of T800 coating respectively. This shows that adhesion of Ti64/T800 is higher than the cohesion strength (8,740 psi) of T800 coating. Therefore T800 coating is strongly advisable for the surface coating on HVS such as high speed air-bearing spindle.

  • PDF

Corrosion Behavior of Si,Zn and Mn-doped Hydroxyapatite on the PEO-treated Surface

  • Park, Min-Gyu;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.78-78
    • /
    • 2017
  • Pure Titanium and alloy have been widely used in dental implants and orthopedics due to their excellent mechanical properties, biocompatibility and corrosion resistance. However, due to the biologically inactive nature of Ti metal implants, it cannot bind to the living bone immediately after transplantation into the body. In order to improve the bone bonding ability of titanium implants, many attempts have been made to alter the structure, composition and chemical properties of titanium surfaces, including the deposition of bioactive coatings. The PEO method has the advantages of short experiment time and low cost. These advantages have attracted attention recently. Recently, many metal ions such as silicon, magnesium, zinc, strontium, and manganese have received attention in this field due to their impact on bone regeneration. Silicon (Si) in particular has been found to be essential for normal bone and cartilage growth and development. Zinc (Zn) plays very important roles in bone formation and immune system regulation and promotes bone metabolism and growth. Manganese (Mn) is an essential trace metal found in all tissues and is required for normal amino acid, lipid, protein and carbohydrate metabolism. The objective of this work was research on the corrosion behavior of Si, Zn and Mn-doped hydroxyapatite on the PEO-treated surface. Anodized alloys was prepared at 270V~300V voltage in the solution containig Zn, Si, and Mn ions. Ion release test was carried out using potentidynamic and AC impedance method in 0.9% NaCl solution. The surface characteristics of PEO treated Ti-6Al-4V alloy were investigated using XRD, FE-SEM, AFM and EDS.

  • PDF

Impact of lattice versus solid structure of 3D-printed multiroot dental implants using Ti-6Al-4V: a preclinical pilot study

  • Lee, Jungwon;Li, Ling;Song, Hyun-Young;Son, Min-Jung;Lee, Yong-Moo;Koo, Ki-Tae
    • Journal of Periodontal and Implant Science
    • /
    • 제52권4호
    • /
    • pp.338-350
    • /
    • 2022
  • Purpose: Various studies have investigated 3-dimensional (3D)-printed implants using Ti6Al-4V powder; however, multi-root 3D-printed implants have not been fully investigated. The purpose of this study was to explore the stability of multirooted 3D-printed implants with lattice and solid structures. The secondary outcomes were comparisons between the 2 types of 3D-printed implants in micro-computed tomographic and histological analyses. Methods: Lattice- and solid-type 3D-printed implants for the left and right mandibular third premolars in beagle dogs were fabricated. Four implants in each group were placed immediately following tooth extraction. Implant stability measurement and periapical X-rays were performed every 2 weeks for 12 weeks. Peri-implant bone volume/tissue volume (BV/TV) and bone mineral density (BMD) were measured by micro-computed tomography. Bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) were measured in histomorphometric analyses. Results: All 4 lattice-type 3D-printed implants survived. Three solid-type 3D-printed implants were removed before the planned sacrifice date due to implant mobility. A slight, gradual increase in implant stability values from implant surgery to 4 weeks after surgery was observed in the lattice-type 3D-printed implants. The marginal bone change of the surviving solid-type 3D-printed implant was approximately 5 mm, whereas the value was approximately 2 mm in the lattice-type 3D-printed implants. BV/TV and BMD in the lattice type 3D-printed implants were similar to those in the surviving solid-type implant. However, BIC and BAFO were lower in the surviving solid-type 3D-printed implant than in the lattice-type 3D-printed implants. Conclusions: Within the limits of this preclinical study, 3D-printed implants of double-rooted teeth showed high primary stability. However, 3D-printed implants with interlocking structures such as lattices might provide high secondary stability and successful osseointegration.

InGaN/GaN Blue LED device 제조시 ALD (Atomic Layer Deposition) 방법으로 증착된 Al2O3 Film의 Passivation 효과

  • 이성길;방진배;양충모;김동석;이정희
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.211-212
    • /
    • 2010
  • GaN 기반의 상부발광형 LED는 동작되는 동안 생기는 전기적 단락, 그리고 칩 위의 p-형 전극과 n-형 전극 사이에 생기는 누설전류 및 신뢰성 확보를 위하여 칩 표면에 passivation 층을 형성하게 된다. SiO2, Si3N4와 같은 passivation layers는 일반적으로 PECVD (Plasma Enhanced Chemical Vapor Deposition)공정을 이용한다, 하지만 이는 공정 특성상 plasma로 인한 damage가 유발되기 때문에 표면 누설 전류가 증가 한다. 이로 인해 forward voltage와 reverse leakage current의 특성이 저하된다. 본 실험에서는 원자층 단위의 박막 증착으로 인해 PECVD보다 단차 피복성이 매우 우수한 PEALD(Plasma Enhanced Atomic Layer Deposition)공정을 이용하여 Al2O3 passivation layer를 증착한 후, 표면 누설전류와 빛의 출력 특성에 대해서 조사해 보았다. PSS (patterned sapphire substrate) 위에 성장된 LED 에피구조를 사용하였고, TCP(Trancformer Copled Plasma)장비를 사용하여 에칭 공정을 진행하였다. 이때 투명전극을 증착하기 위해 e-beam evaporator를 사용하여 Ni/Au를 각각 $50\;{\AA}$씩 증착한 후 오믹 특성을 향상시키기 위하여 $500^{\circ}C$에서 열처리를 해주었다. 그리고 Ti/Au($300/4000{\AA}$) 메탈을 사용하여 p-전극과 n-전극을 형성하였다. Passivation을 하지 않은 경우에는 reverse leakage current가 -5V 에서 $-1.9{\times}10-8$ A 로 측정되었고, SiO2와 Si3N4을 passivation으로 이용한 경우에는 각각 $8.7{\times}10-9$$-2.2{\times}10-9$로 측정되었다. Fig. 1 에서 보면 알 수 있듯이 5 nm의 Al2O3 film을 passivation layer로 이용할 경우 passivation을 하지 않은 경우를 제외한 다른 passivation 경우보다 reverse leakage current가 약 2 order ($-3.46{\times}10-11$ A) 정도 낮게 측정되었다. 그 이유는 CVD 공정보다 짧은 ALD의 공정시간과 더 낮은 RF Power로 인해 plasma damage를 덜 입게 되어 나타난 것으로 생각된다. Fig. 2 에서는 Al2O3로 passivation을 한 소자의 forward voltage가 SiO2와 Si3N4로 passivation을 한 소자보다 각각 0.07 V와 0.25 V씩 낮아지는 것을 확인할 수 있었다. 또한 Fig. 3 에서는 Al2O3로 passivation을 한 소자의 output power가 SiO2와 Si3N4로 passivation을 한 소자보다 각각 2.7%와 24.6%씩 증가한 것을 볼 수 있다. Output power가 증가된 원인으로는 향상된 forward voltage 및 reverse에서의 leakage 특성과 공기보다 높은 Al2O3의 굴절률이 광출력 효율을 증가시켰기 때문인 것으로 판단된다.

  • PDF

복합층에서 나타나는 투과형 펄스와전류 신호의 특성 (Characteristics of Through Transmission Pulsed Eddy Current Signals from layers)

  • 최동명;신영길;권영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.53-55
    • /
    • 2008
  • 복합층에서 나타나는 투과형 펄스와전류(Pulsed Eddy Current; PEC) 탐상신호를 수치해석 방법을 사용하여 예측하고 분석하였다. 공기층이 없는 복합층에서 Ti-6Al-4V의 두께가 변하는 경우에는 Lift-off를 변화시켰을 때 나타나는 펄스와전류 신호특성과 LOI(Lift-off Intersection)가 형성되는 것을 관찰할 수 있었고, Aluminum의 두께가 변하는 경우에는 Aluminum만의 두께변화 시 발생하던 신호특성이 났다. 공기층이 있는 복합층에서는 Lift-off를 변화시켰을 때 나타나는 신호특성과 LOI가 형성되었고, 공기층이 증가하면 피크 값이 감소하는 것을 볼 수 있었다.

  • PDF

티타늄금속기 복합재료의 강화공정에 관한 미시역학적 모델링 (Micro-mechanical Modeling of the Consolidation Processes in Titanium Metal Matrix Composites)

  • 김준완;김태원
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 춘계학술발표대회 논문집
    • /
    • pp.207-210
    • /
    • 2002
  • Metal matrix composites(MMCs) are increasingly attractive for high technology components such as aerospace applications and transportations due to their high strength, stiffness, and toughness. Many processes for fabricating MMCs have been developed, and relatively simple Foil-Fiber-Foil method is usually employed in solid state consolidation processes. During the consolidation processes at high temperature, densification occurs by the inelastic flow of the matrix materials, and the process is coupled with the conditions of pressure, temperature and volume fraction of fiber and matrix materials. This is particularly important in titanium matrix composites, and thus a generic model based on micro-mechanical approaches enabling the evolution of density over time to be predicted has been developed. The mode developed is then implemented into FEM so that practical process simulation has been carried out. Further the experimental investigation of the consolidation behavior of SiC/Ti-6Al-4V composites using vacuum hot pressing has been performed, and the results obtained are compared with the model predictions.

  • PDF

결정 소성 시뮬레이션을 이용한 프레팅 접촉에서의 마이크로 구조 영향에 관한 연구 (The Study of Microstructure Influence at Fretting Contacts using Crystal Plasticity Simulation)

  • 고준빈;고충현;이기석
    • 한국정밀공학회지
    • /
    • 제22권8호
    • /
    • pp.84-91
    • /
    • 2005
  • The role of microstructure is quite significant in fretting of Ti-6Al-4V since its material properties depend strongly on crystallographic texture. In this study, we adopt crystal plasticity theory with a 2-D planar triple slip idealization to account fur microstructure effects such as grain orientation distribution, grain geometry, as well as $\alpha$ colony size. Crystal plasticity simulations suggest strong implications of microstructure effects at fretting contacts.