• Title/Summary/Keyword: Ti-6A1-4V

Search Result 377, Processing Time 0.024 seconds

A STUDY ON THE RESISTANCE OF WEAR AND CYTOTOXICITY OF THE TITANIUM SURFACE AFTER FILM DEPOSITIONS (박막증착시 티타늄 표면의 마손저항도와 세포독성에 관한 연구)

  • Kim Hyung-Woo;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.84-95
    • /
    • 2001
  • Titanium is widely used in dentistry for its low density, high strength, fatigue resistance, corrosion resistance, and biocompatibility. But it has a tendency of surface damage under circumstance of friction and impact for its low hardness of the surface. Coating is one of methods fir increasing surface hardness. Its effect is to improve surface physical characteristics without change of titanium. Diamond-like carbon and titanium nitride are known for its high hardness of the surface. So that this study was aimed at the wear test and the cytotoxicity test of the commercially pure titanium and Ti-6Al-4V alloy which were deposited by diamond-like carbon film or titanium nitride film to acertain improvement of the surface hardness and the biocompatibility. A disk (25mm diameter, 2mm thickness) was made of commercially pure titanium and Ti-6Al-4V alloy and these substrates were deposited by diamond-like carbon film or titanium nitride film. Diamond-like carbon film was deposited by the method of radiofrequency plasma assisted chemical vapor deposition and titanium nitride film was deposited by the method of reactive arc ion plating. Then these substrates were tested about wear characteristics by the pin-on-disk type wear tester in which ruby ball was used as a wear causer under the load of 32N, The fracture cycles were measured by rotating the substrates until their films were fractured. The wear volume was measured after 150 cycles and 3,000 cycles using surface profiler. The cytotoxicity test was peformed by the method of the MTT assay. The results were as follows : 1. In the results of the wear volume test, commercially pure titanium and titanium alloy which were coated by diamond-like carbon film or titanium nitride aim had higher resistance against wear than the substrates which were not coated by any films (P<0.05). 2. In the results of the fracture cycle test and the wear volume test, diamond-like carbon film had higher resistance against wear than titanium nitride film (P<0.05). 3. In both coatings of diamond-like carbon aim and titanium nitride film, Ti-6Al-4V alloy had higher resistance against wear than commercially pure titanium (P<0.05) 4. In the results of the cytotoxicity test, diamond-like carbon film and titanium nitride film had little cytotoxicity as like commercially pure titanium or Ti-6Al-4V alloy (P>0.05).

  • PDF

The Dry Etching Characteristics of TiO2 Thin Films in N2/CF4/Ar Plasma

  • Choi, Kyung-Rok;Woo, Jong-Chang;Joo, Young-Hee;Chun, Yoon-Soo;Kim, Chang-Il
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.1
    • /
    • pp.32-36
    • /
    • 2014
  • In this study, the etching characteristics of titanium dioxide ($TiO_2$) thin films were investigated with the addition of $N_2$ to CF4/Ar plasma. The crystal structure of the $TiO_2$ was amorphous. A maximum etch rate of 111.7 nm/min and selectivity of 0.37 were obtained in an $N_2/CF_4/Ar$ (= 6:16:4 sccm) gas mixture. The RF power was maintained at 700 W, the DC-bias voltage was - 150 V, and the process pressure was 2 Pa. In addition, the etch rate was measured as functions of the etching parameters, such as the gas mixture, RF power, DC-bias voltage, and process pressure. We used X-ray photoelectron spectroscopy to investigate the chemical state on the surface of the etched $TiO_2$ thin films. To determine the re-deposition and reorganization of residues on the surface, atomic force microscopy was used to examine the surface morphology and roughness of $TiO_2$ thin films.

A study on corrosion resistance of Ti-Nb alloys by Nb contents (Nb 함량에 따른 Ti-Nb계 합금의 내식성에 대한 연구)

  • Park, Geun-Hyeung
    • Journal of Technologic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.61-66
    • /
    • 2006
  • Titanium alloys have been used for dental materials due to it's very good biocompatibility. Ti-6Al-4V alloy instead of pure titanium is being widely used as biomaterials has some characteristics such as high fatigue strength, tensile strength and corrosion resistance. But it has been reported recently that the vanadium element expresses cytotoxicity and carcinogenicity and the aluminium element is related with dementia of Alzheimer type and neurotoxicity. The Ti-Nb alloys has designed and examined corrosion resistance. Ti-3wt.%Nb($\alpha$type), Ti-20wt.%Nb(${\alpha}+{\beta}$type) and Ti-40wt.%Nb($\beta$type) alloys were melted by vacuum arc furnace. The corrosion resistance of Ti alloys was evaluated by potentiodynamic polarization test in the solution of 0.9% NaCl and 5% HCl. The results can be summarized as follows: 1) For the corrosion test in the solution of 0.9% NaCl and 5% HCl, the corrosion behaviour of Ti-Nb alloys was similar to ASTM grade 2 CP Ti. 2) The corrosion resistance of Ti-20Nb alloy was better than that of CP-Ti, Ti-3Nb, Ti-40Nb alloy in 0.9% NaCl and 5% HCl, solutions.

  • PDF

Deposition $Ba_{1-x}Sr_xTiO_3$Thin Films and Electrical Properties with Various Materials Top Electrodes (강유전체$Ba_{1-x}Sr_xTiO_3$ 박막의 제조 및 상부전극재료에 따른 전기적 특성)

  • Park, Choon-Bae;Kim, Deok-Kyu;Jeon, Jang-Bae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.6
    • /
    • pp.410-415
    • /
    • 1999
  • $Ba_{1-x}Sr_xTiO_3$ thin films with various ratio of Sr (X = 0.4, 0.5, 0.6) were grown $Pt/TiN/SiO_2/Si$ subastrate by RF magnetron sputtering deposition. As, Ag, and Cu films were deposited on $Ba_{1-x}Sr_xTiO_3$ thin films as top electrodes by using a thermal evaporator. The electrical properties of $Ba_{1-x}Sr_xTiO_3$ thin films for various compositions were characterized and the physical properties at interface between $Ba_{1-x}Sr_xTiO_3$ thin films and top electrodes were evaluated in terms of the work function difference. At x =0.5, the degradation of capacitance is lower to the other compositions. As negative biasapplied, the specimen with Cu top electrode has board saturation region and low leakage current since work function of Cu is bigger than other electrodes.$ Ba_{0.5}Sr_{0.5}TiO_3$ thin films with Cu top electrode, the dielectric constant was measured to the value of 354 at 1 kHz and the leakage current was obtained to the value of $5.26\times10^{-6}A/cm2$ at the forward bias of 2 V.

  • PDF

Enhanced Photoelectrochemical Reaction of MoS2 Nanosheets Vertically Grown on TiO2 Nanowires (MoS2 나노시트의 TiO2 나노선에 수직 성장을 통한 광전기화학반응 향상)

  • Seo, Dong-Bum;Kim, Eui-Tae
    • Korean Journal of Materials Research
    • /
    • v.31 no.2
    • /
    • pp.92-96
    • /
    • 2021
  • We report the growth and enhanced photoelectrochemcial (PEC) water-splitting reactivity of few-layer MoS2 nanosheets on TiO2 nanowires. TiO2 nanowires with lengths of ~1.5 ~ 2.0 ㎛ and widths of ~50~300 nm are synthesized on fluorine-doped tin oxide substrates at 180 ℃ using hydrothermal methods with Ti(C4H9O)4. Few-layer MoS2 nanosheets with heights of ~250 ~ 300 nm are vertically grown on TiO2 nanowires at a moderate growth temperature of 300 ℃ using metalorganic chemical vapor deposition. The MoS2 nanosheets on TiO2 nanowires exhibit typical Raman and ultraviolet-visible light absorption spectra corresponding to few-layer thick MoS2. The PEC performance of the MoS2 nanosheet/TiO2 nanowire heterostructure is superior to that of bare TiO2 nanowires. MoS2/TiO2 heterostructure shows three times higher photocurrent than that of bare TiO2 nanowires at 0.6 V. The enhanced PEC photocurrent is attributed to improved light absorption of MoS2 nanosheets and efficient charge separation through the heterojunction. The photoelectrode of the MoS2/TiO2 heterostructure is stably sustained during on-off switching PEC cycle.

Dielectric properties of $0.6Pb(Sc_{1/2}Ta_{1/2})O_3-0.4PbTiO_3$ ceramics prepared by the molten salt synthesis method (용융염 합성법에 의해 제조된 $0.6Pb(Sc_{1/2}Ta_{1/2})O_3-0.4PbTiO_3$ 세라믹스의 유전성)

  • Park, Kyung-Bong;Kim, Tae-Huei;Kwon, Seung-Hyup;Lim, Dong-Ju
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.17 no.2
    • /
    • pp.69-74
    • /
    • 2007
  • [ $0.6Pb(Sc_{1/2}Ta_{1/2})O_3-0.4PbTiO_3$ ] (hereafter PSTT) ceramics were prepared by the molten salt synthesis (MSS) method using KCI as a flux. Formation of perovskite phase was investigated by a differential thermal analysis (DTA) and X-ray diffraction (XRD) analysis in the temperature range from $600^{\circ}C$ to $850^{\circ}C$. A 92% perovskite phase was synthesized at $750^{\circ}C$ for 2 hrs using the MSS method, while 82% perovskite phase was synthesized at $850^{\circ}C$ for 4ks using the calcining of mixed oxide (CMO) method. This result could be due to the improvement in reactivity of $Sc_2O_3$ by melting of KCI. The MSS specimen sintered at $1,100^{\circ}C$ for 4hrs showed a dielectric constant of 11,200, a remnant polarization of $13.5{\mu}C/cm^2$ and a coercive field of 10.198 kV/cm, which was discussed in view of the microstructure.

Process Characteristics and Applications of High Density Plasma Assisted Sputtering System (HiPASS)

  • Yang, Won-Gyun;Kim, Gi-Taek;Lee, Seung-Hun;Kim, Do-Geun;Kim, Jong-Guk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.95-95
    • /
    • 2013
  • 박막 공정 기술은 반도체 및 디스플레이뿐만 아니라 대부분의 전자소자에 적용되는 매우 중요한 기술이다. 그 중, 마그네트론 스퍼터링 공정은 플라즈마를 이용하여 금속 및 세라믹 등의 벌크 물질을 박막으로 증착 가능한 가장 널리 사용되는 방법 중의 하나이다. 하지만, Fe, Co, Ni 같은 강자성체 재료는 공정이 불가능하며, 스퍼터링 타겟 효율이 40% 이하이고, 제한적인 방전압력 범위 및 전류 상승에 의한 높은 전압 인가 제한이 있다는 단점이 있다. 본 연구에서 사용된 고밀도 플라즈마 소스를 적용한 고효율 스퍼터링 시스템은 할로우 음극을 이용한 원거리에서 고밀도 플라즈마를 생성하여 전자석 코일을 통해 자석이 없는 음극으로 이온을 수송시켜 스퍼터링을 일으킨다. 따라서 강자성체 재료의 스퍼터링이 가능하며, 90% 이상의 타겟 사용 효율 구현 및 기존 마그네트론 스퍼터링 대비 고속 증착이 가능하다. 또한, $10^{-4}$ Torr 압력영역에서 방전 및 스퍼터링이 가능하다. 타겟 이온 전류를 타겟 인가 전압과 관계없이 0~4 A까지, 타겟 이온 전류와 상관없이 타겟 인가 전압을 70~1,000 V 이상까지 독립적으로 제어가능하다. 또한 TiN과 같은 질소 반응성 공정에서 반응성 가스인 질소를 40%까지 넣어도 타겟에 수송되는 이온의 양에 영향이 없다. 할로우 음극 방전 전류 40 A에서 발생된 플라즈마의 이온에너지 분포는 55 eV에서 가우시안 분포를 보였으며, 플라즈마 포텐셜인 sheath drop은 74 V 였다. OES를 통한 광학적 진단 결과, 전자석에 의한 이온빔 초점에 따라 플라즈마 이온화율을 1.8배까지 증가시킬 수 있으며, 할로우 음극 방전 전류가 60~100 A로 증가하면서 플라즈마 이온화율을 6배까지 증가 가능하다. 또한, 타겟 이온 전류와 관계없이 타겟 인가 전압을 300~800 V로 증가시킴에 따라 Ar 이온 밀도의 경우 1.4배 증가, Ti 이온 밀도의 경우 2.2배 증가시킬 수 있었으며, TiN의 경우 증착 속도도 16~44 nm/min으로 제어가 가능하다.

  • PDF

Material Characteristics of Ti-6Al-4V Alloy Manufactured by Electron Beam Melting for Orthopedic Implants (전자빔 용해 방법으로 제조된 정형외과 임플란트용 Ti-6Al-4V 합금의 재료 특성 분석)

  • Gang, Gwan-Su;Jeong, Yong-Hun;Jang, Tae-Gon;Yang, Jae-Ung;Jeong, Jae-Yeong;Park, Gwang-Min;U, Su-Heon;Park, Tae-Hyeon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.25-25
    • /
    • 2018
  • Electron beam melting (EBM) is one of powder based additive manufacturing technology used to produce parts for high geometrical complexity and directly with three-dimensional computer aided design (CAD) model. It is kind of the most promising methods with additive manufacturing for a wide range of medical applications, such as orthopedic, dental implant, and etc. This research has been investigated the microstructure and mechanical properties of as fabricated and hot iso-static pressing (HIP) processed specimens, which are made by an Arcam A1 EBM system. The Ti-6Al-4V titanium alloy powder was used as a material for the 3 dimensional printing specimens. Mechanical properties were conducted with EBM manufacturing and computer numerical control (CNC) machining specimens, respectively. Surface morphological analysis was conducted by scanning electron microscopy (SEM) for their surface, dissected plan, and fractured surface after tensile test. The mechanical properties were included tensile stress-strain and nano-indentation test as a analysis level between nano and macro. As following highlighted results, the stress-strain curves on elastic region were almost similar between as fabricated and HIP processed while the ductile (plastic deformed region) properties were higher with HIP than that of as fabricated processed.

  • PDF

AN EXPERIMENTAL STUDY ON THE OSSEOINTEGRATION OF THE TI-6AL-4V BEAD COATING IMPLANTS (Ti-6Al-4V 비드코팅 임프란트 시제품의 골유착에 대한 실험적 연구)

  • Woo, Jin-Oh;Park, Bong-Wook;Byun, June-Ho;Kim, Seung-Eon;Kim, Gyoo-Cheon;Park, Bong-Soo;Kim, Jong-Ryoul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.1
    • /
    • pp.52-59
    • /
    • 2008
  • The geometric design of an implant surface may play an important role in affecting early osseointegration. It is well known that the porous surfaced implant had much benefits for the osseointegration and the early stability of implant. However, the porous surfaced implant had weakness from the transgingival contamitants, and it resulted in alveolar bone loss. The other problem identified with porous surface implant is the loss of physical properties resulting from the bead sintering process. In this study, we developed the new bead coating implant to overcome the disadvantages of porous surfaced implant. Ti-6Al-4V beads were supplied from STARMET (USA). The beads were prepared by a plasma rotating electrode process (PREP) and had a nearly spherical shape with a diameter of 75-150 ${\mu}m$. Two types of titanium implants were supplied by KJ Meditech (Korea). One is an external hexa system (External type) and the other is an internal system with threads (Internal type). The implants were pasted with beads using polyvinylalcohol solution as a binder, and then sintered at 1250 $^{\circ}C$ for 2 hours in vacuum of $10^{-5}$ torr. The resulting porous structure was 400-500 ${\mu}m$ thick and consisted of three to four bead layers bonded to each other and the implant. The pore size was in the range of 50-150 ${\mu}m$ and the porosity was 30-40 % in volume. The aim of this study was to evaluate the osseointegration of the newly developed dental implant. The experimental implants (n=16) were inserted in the unilateral femur of 4 mongrel dogs. All animals were killed at 8 weeks after implantation, and samples were harvested for hitological examination. All bead coated porous implants were successfully osseointegrated with peripheral bone. The average bone-implant contact ratios were 84.6 % (External type) and 81.5 % (Internal type). In the modified Goldner's trichrome staining, new generated mature bones were observed at the implant interface at 8 weeks after implantation. Although, further studies are required, we could conclude that the newly developed vacuum sintered Ti-6Al-4V bead coating implant was strong enough to resist the implant insertion force, and it was easily osseointegrated with peripheral bone.

Determination of Heavy Metals Concentrations in Urban Air using ICP Method : in the Area of Chung-Ang University (ICP법에 의한 도시대기중 중금속 농도 측정: 중앙대학교를 중심으로)

  • 손동헌;신혜숙;정성윤;정원태
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.222-229
    • /
    • 1993
  • Total suspended particles in the atmosphere were collected on the quartz fiber filters using an ANdersen Hi-volume air sampler from March 1989 to October 1989 and from June 1990 to February 1991, at Chung-Ang University in Seoul. A total amount of eight heavy metals (Cr, Zn, Cd, Pb, Fe, V, Ti, Mn) in total suspended particles were determined by ICP spectrophotometer. The annual arithmetic mean concentration of total suspended particle was 162.3$\mug/m^3$ and eight metals(Cr, Zn, Cd, Pb, Fe, V, Ti, Mn) were 11.6, 609.2, 3.5, 337.1, 2739.5, 15.1, 89.4 and 100.5ng/$m^3$, respectively. The concentration of total suspended particle was highest in the spring(343.7$\mug/m^3$) and lowest in the summer(91.8$\mug/m^3$). These heavy metals were distinguished into two groups in terms of their particle size distribution. The contents of first-group heavy metals (Fe, Ti, Mn) were increased in accordance with the growth of the particle size. The contents of the second-group ones such as Pb, Cd, V, and Zn, on the contrary, came to increase according as the particle size reduced. Statistical analysis indicated that there was a correlation between total suspended particle and Fe in coarse particles, and between total Suspended Particle and Zn, Pb in fine particle.

  • PDF