• Title/Summary/Keyword: Through-transmission measurement

Search Result 319, Processing Time 0.03 seconds

A Study on the Sensitivity Elevation about Spirometer Using Ultrasound Sensing Method (초음파 센싱 방식의 spirometer에 대한 sensitivity 향상 연구)

  • Han, Seung-Heon;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.1
    • /
    • pp.204-209
    • /
    • 2005
  • The respiration measurement method using the ultrasound sensor hardly gets an influence of an error of inertia and pressure and it is a respiratory detection device available semi-permanently. This device measures the amount and flow of respiration through using a delivery speed difference of the ultrasound waves that are a return format by the pneumatic stream that is a flogging of ultrasound waves during transmission and receipt as having used a characteristic of ultrasound waves. In this paper, it improved sensitivity of a signal to happen during transmission and receipt of a sensor because measurement must be performed with a patient to the center and measurement was played in a weak breathing so that it was possible.

A Study on Thermal Conductivity Measurement and Optical Characteristics of Thin Films (박막의 열물성 측정 및 광학특성 연구)

  • Gwon, Hyuk-Rok;Lee, Seong-Hyuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2202-2207
    • /
    • 2007
  • The present article investigates experimentally and theoretically thermal and optical characteristics of thin film structures through measurement of thermal conductivity of Pyrex 7740 and reflectance in silicon thin film. The $3{\omega}$ method is used to measure thermal conductivity of very thin film with high accuracy and the optical characteristics in thin films are studied to examine the influence of incidence angle of light on reflectance by using the CTM(Characteristics Transmission Method) and the 633 nm He-Ne laser reflectance measurement system. It is found that the estimated reflectance of silicon show good agreement with experimental data. In particular, the present study solves the EPRT(Equation of Phonon Radiative Transport) which is based on Boltzmann transport equation for predicting thermal conductivity of nanoscale film structures. From the results, the measured thermal conductivity is in good agreement with the previous published data. Moreover, thermal conductivities are estimated for different film thickness. It indicates that as film thickness decreases, thermal conductivity decreases substantially due to internal scattering.

Simultaneous measurements of red blood cell aggregation and blood viscosity in a slit rheometry with light transmission analysis (광 투사법을 이용한 슬릿 점도계에서의 적혈구 응집성 및 점도 측정에 관한 연구)

  • Park, Myung-Su;Ku, Yun-Hee;Shin, Se-Hyun;Suh, Jang-Su
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1678-1681
    • /
    • 2004
  • The light-transmission technique has been applied to a slit rheometer for measuring red blood cell aggregation as well as blood viscosity over a range of shear rates. For measurement of blood viscosity and aggregation, instantaneous pressure and transmit-light intensity are measured with time. Using a precision pressure measurement, one can determine the shear stress and shear rate. In addition, a transmitted light through a blood sample indicates degree of RBC aggregation. With abruptly flowing with high shear rate, RBCs rapidly disaggregate and the intensity of the transmitted light becomes low. When continuously flowing with decreasing shear rate, RBCs tend to re-aggregate and the corresponding transmit-intensity gradually increases with time. The light intensity as a degree of RBC aggregation is plotted against shear rate and compared with blood viscosity. The advantages of this design are dual measurement at a time, simplicity, i.e., ease of operation and no moving parts, low cost, short operating time, and the disposable kit which is contacted with blood sample.

  • PDF

Stopband-Extended and Size-Miniaturized Low-Pass Filter with Three Transmission Zeros

  • Li, Lin;Bao, Jia;Du, Jing-Jing;Wang, Yaming
    • ETRI Journal
    • /
    • v.36 no.2
    • /
    • pp.286-292
    • /
    • 2014
  • This paper presents a compact structure composed of an upper high-impedance transmission line, a middle extended parallel coupled line, and a pair of inter-coupled symmetrical stepped impedance stubs. Detailed investigation into this structure based on an equivalent circuit analysis reveals that this proposed structure exhibits a quasi-elliptic low-pass filtering response with three transmission zeros. Moreover, the positions of the three transmission zeros can be tuned and reallocated flexibly by choosing the proper circuit parameters. Finally, the design concept is validated through the design, fabrication, and measurement of two exemplary low-pass filters (LPFs) with one single unit and two cascaded asymmetric units. The measured results agree well with the simulated results. In addition, in the range of $1.42f_c$ to $7.03f_c$, the fabricated quasi-elliptic LPFs experimentally demonstrate a very wide upper-stopband of 20 dB using a compact size of only $0.0089{\lambda}_g{^2}$, where ${\lambda}_g$ is the guided wavelength of a $50{\Omega}$ transmission line at the central frequency.

A Study on the Design of a Gear Transmission Error Test Rig (기어 전달오차 측정 장비의 설계에 관한 연구)

  • Zhang, Qi;Zhang, Jing;Yan, Hou-Ling;Zhu, Qing-Wang;Xu, Zhe-zhu;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.1
    • /
    • pp.14-19
    • /
    • 2016
  • Transmission error (TE) is the most important cause of gear noise and vibration because TEs affect the changes of the force and the speed of gears. TE is usually expressed as an angular deviation, or a linear deviation measured at the pitch point and calculated at successive positions of the pinion as it goes through the meshing cycle. Accurate measurement of TE for gear transmission will provide a reasonable basis for gear design, manufacturing processes and quality control. Therefore, in order to study the accuracy of the gear transmission, stability, TE, vibration and noise after gear micro-geometry modification, a gear transmission test rig is proposed in this paper, which is based on the existing technical conditions, by using reasonable testing methods, hardware and a signal processing method. All of the details and the experience can be taken into consideration in the next upgraded test rig.

The measurement-based analysis of the effect of CQI and BLER on the transmission rate of a LTE system (실측을 통한 CQI와 BLER가 LTE 시스템의 전송 속도에 미치는 영향 분석)

  • Kim, Beom-Joon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.12
    • /
    • pp.1365-1372
    • /
    • 2014
  • In recent, the LTE(Long-Term Evolution) mobile communication system has been commercialized and a variety of service is being provided. Comparing to the old wireless access systems such as 3G mobile communications, in particular, the LTE system supports a service requiring a high transmission rate by providing broadband wireless access. In order to understand the possibility of successful support of a multimedia service such as IPTV(Internet Protocol Television) through the LTE system, it is necessary to understand the mechanism that decides the transmission rate supported by the LTE system. This paper, therefore, discusses on the relationship between a number of metrics such as CQI and BLER that affects the transmission rate with the measurement results from the field tests.

Ideal Topographic Simulations for Null Measurement Data

  • Su, Yan-Jen;Tung, Chi-Hong;Chang, Leh-Rong;Chen, Jin-Liang;Chang, Calvin
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.79-82
    • /
    • 2008
  • A method is described for ideally reconstructing the profile from a surface profiling measurement containing a reasonable amount of null measurement data. The proposed method can conjecture lost information and rectify irregular data that result due to bad measuring environments, signal transmission noise, or instrument-induced errors, The method adopts the concept of computer graphics and consists of several processing steps. First, a search for valid data in the neighborhood of the null data is performed. The valid data are then grouped and their contours are extracted. By analyzing these contours, a bounding box can be obtained and the general distribution of the entire area encompassing the valid and null data is determined Finally, an ideal surface model is overlaid onto the measurement results based on the bounding box, generating a complete reconstruction of the calculations, A surface-profiling task on a liquid crystal display photo spacer is used to verify the proposed method. The results are compared to those obtained through the use of a scanning electron microscope to demonstrate the accuracy of the proposed method.

Comparison of the Model-predicted and Measured Target Strength of Cuttlebones from Golden Cuttlefish Sepia esculenta (갑오징어의 갑에 대한 모델 예측과 측정 반사강도의 비교)

  • Lee, Dae-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.53 no.2
    • /
    • pp.209-217
    • /
    • 2020
  • The purpose of this study was to compare the model-predicted and experimentally measured target strength (TS) of golden cuttlefish Sepia esculenta cuttlebones. Ultrasonic signals used to estimate frequency-dependent TS and the speed of sound in cuttlebones were measured by pulse-echo and through-transmission techniques, using a chirp sonar system and an ultrasonic pulser/receiver system under controlled laboratory conditions. The model appeared to slightly underestimate the predicted TS values in the frequency range of 100-160 kHz. However, there was good agreement between the predicted and measured TS values in the frequency range of 160-200 kHz. The significant similarity between the model-predicted and experimentally measured TS values supports the use of the Kirchhoff-ray mode (KRM) model for acoustic scattering analysis of cuttlebones. Accordingly, we concluded that the KRM model can be used as a tool to evaluate the frequency-dependent variability of TS due to changes in golden cuttlefish swimming depth.

A study on the performance of the perforated-tube muffler (다공형 소음기의 성능에 관한 연구)

  • 권영필;현길학;서기원
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.12 no.5
    • /
    • pp.85-96
    • /
    • 1990
  • The object of this study is to develop the computer program to predict the transmission loss of a perforated tube muffler with mean flow, and to investigate the influence of porosity and mean flow on the performance of the muffler. The numerical model is made by dividing the muffler into small segments and estimating the transfer matrices for each segment. The computer program is developed for the calculation of the transmission loss of a through-or cross-flow perforated muffler. The experiment is performed for the measurement of the transmission loss and/or the pressure drop for various porosity and flow velocity. From the comparison between computation and experiment, is known that the numerical model agrees well with the experimental result. The effect of porosity and flow velocity on the acoustic performance and the flow resistance of a muffler is presented.

  • PDF

Design of Miniaturized Directional Coupler Utilizing Lumped Element (집중소자를 이용한 소형화된 방향성 결합기 설계)

  • Yong, Kwang-Seong;Yook, Jong-Gwan
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.251-255
    • /
    • 2003
  • In this paper, a miniaturized directional coupler utilizing lumped element is proposed as a interdigital capacitor. The traditional miniaturization technique of transmission line realized a utilizing MIM(Metal-Insulator-Metal) capacitor on CPW(Coplanar Waveguide). However, we present a simplified design procedure without additional manufacturing process utilizing interdigital capacitor on microstrip with ease of design. The similar characteristics between the conventional directional coupler with ${\lambda}/4$ transmission line and the miniaturized directional coupler with ${\lambda}/8$ transmission line are validated through simulation and measurement results. Miniaturization rate of total size is about 25% while coupled line is about 60%. As a result, this proposed directional coupler can reduce the size of mobile communication system at 2 GHz.

  • PDF