• Title/Summary/Keyword: Thromboembolism

Search Result 357, Processing Time 0.034 seconds

Active Prosthetic Valve Endocarditis: The Clinical Profile, Laboratory Findings and Mid-term Surgical Results (활동성 인공판막 심내막염: 임상 양상, 검사 소견 및 중기 수술 성적)

  • Kim, Hwan-Wook;Joo, Seok;Kim, Hee-Jung;Choo, Suk-Jung;Song, Hyun;Lee, Jae-Won;Chung, Cheol-Hyun
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.447-455
    • /
    • 2009
  • Background: Prosthetic valve endocarditis usually presents with clinical symptoms that are more severe than native valve endocarditis, and prosthetic valve endocarditis shows the spread of infection into the surrounding tissue as well as into the superficial endocardial layers. The postoperative prognosis is especially poor for valve re-replacement for the cases of active endocarditis that are unable to receive a full-course of pre-antibiotic therapy due to complications and the ensuing clinical aggravation. The aim of this study was to evaluate the clinical profiles, laboratory findings and mid-term surgical results of active prosthetic valve endocarditis. Material and Method: Among the 276 surgically treated infective endocarditis patients who were treated during the period from January 1998 to July 2008, 31 patients were treated for prosthetic valve endocarditis. Among these patients, 24 received surgical treatment for an 'active' state, and they were selected for evaluation. Result: The most frequently encountered symptom was a febrile sensation. Eight cases (33.3%) were accompanied by systemic thromboembolism, among which 5 cases (20.8%) had an affected central nervous system. 'Vegetations' were most commonly found on transesophageal echocardiography, and the 'Staphylococcus species' were the most frequent pathogens. There were 4 deaths in the immediate postoperative period, and an additional 4 patients died during the follow-up period (Mean$\pm$SD, 42.1$\pm$36.9 months). The cumulative survival rate was 79% at 1 year, 73% at 3 years, 66% at 5 year, and 49.5% at 7 years. Conclusion: The cases of active prosthetic valve endocarditis that were unable to receive a full course of preoperative antibiotics therapy generally have a poor prognosis. Nevertheless, early surgery and extensive resection of all the infected tissue is pivotal in improving the survival rate of patients with surgically treated active prosthetic valve endocarditis.

Determination of Practical Dosing of Warfarin in Korean Outpatients with Mechanical Heart Valves (인공심장판막 치환환자의 Warfarin 용량결정)

  • Lee Ju Yeun;Jeong Young Mi;Lee Myung Koo;Kim Ki-bong;Ahn Hyuk;Lee Byung Koo
    • Journal of Chest Surgery
    • /
    • v.38 no.11 s.256
    • /
    • pp.761-772
    • /
    • 2005
  • Background: Following the implantation of heart valve prostheses, it is important to maintain therapeutic INR to reduce the risk of thromboembolism. The objective of this study was to suggest a practical dosing guideline for Korean outpatients with prosthetic heart valves managed by a pharmacist-run anticoagulation service (ACS). Material and Method: A retrospective chart review was completed for all patients enrolled in the ACS at Seoul National University Hospital from March, 1997 to September, 2000. Patients who were at least 6 months post-valve replacement and had nontherapeutic INR value (less than 2.0 or greater than 3.0) were included. The data on 688 patients (1,782 visits) requiring dosing adjustment without any known drug or food interaction with warfarin were analyzed. The amount of adjusted dose and INR changes based on the INR at the time of the event were calculated. Aortic valve replacements (AVR) patients and mitral or double valve replacement (MVR/DVR) patients were evaluated separately. Result: Two methods for the warfarin dosage adjustment were suggested: Guideline I (mg-based total weekly dose (TWD) adjustment), Guideline II (percentage-based TWD adjustment). The effectiveness of Guideline 1 was superior to Guideline II overall in patients with both AVR and MVR/DVR. Conclusion: The guideline suggested in this study could be useful when the dosage adjustment of wafarin is necessary in outpatients with mechanical heart valves.

A Clinical Analysis on the Restoration of Sinus Rhythm Following Mitral Valve Surgery (승모판 수술 후 동율동 회복에 관한 임상분석)

  • 백완기;심상석;김현태;조상록;진성훈
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.347-352
    • /
    • 1999
  • Background: The atrial fibrillation in patients with mitral valvular heart disease is frequently converted to sinus rhythm after the mitral valve surgery. This sinus restoration implies an important meaning in that it not only helps postoperative convalescence in patients with unstable hemodynamics but also reduces the rate of postoperative thromboembolism. Material and Method: We retrospectively analyzed 184 patients who received mitral valve surgery from June 1986 to December 1996 to investigate the trend of rhythm change following mitral valve surgery and thus to clarify the predisposing factors of postoperative sinus rhythm conversion and its maintenance. Result: The sinus rhythm was restored after the operation in 54 out of 139 patients with atrial fibrillation preoperatively(38.8%). However, the atrial fibrillation recurred in 41 patients at the time of discharge showing a recurrence rate of 75.9 percent. The mean duration of sinus rhythm in patients with eventual atrial fibrillation recurrence was 8.2${\pm}$5.9 days. Only 15 patients were in sinus rhythm at the time of late follow-up with the mean follow-up period of 84.4${\pm}$34.7 months. While the age, duration of symptoms, duration of atrial fibrillation, left atral size, and pulmonary artery pressure were thought to be the predisposing factors for sinus conversion after the operation, only the duration of atrial fibrillation and ejection fraction were considered risk factors for the recurrence of the atrial fibrillation following sinus conversion. Conclusion: This study suggests that the early operation is mandatory for the satisfactory result regarding postoperative rhythm. Moreover, additional operative measure in adjunct to the intervention of mitral valve should be considered for the maintenance of restored sinus rhythm as reflected by high postoperative recurrence rate of atrial fibrillation.

  • PDF

Valve Replacement in Children (소아심장판막치환술)

  • 김재현;이광숙;윤경찬;유영선;박창권;최세영
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.341-346
    • /
    • 1999
  • Background: Thirty children ranging from 3 to 15 years of age underwent cardiac valve replacement at Dongsan Medical Center from 1982 to 1997. Material and Method: There were 16 boys and 14 girls. The mean age was 12.1. The underlying pathological cause for valve replacement was congenital heart disease in 17 children and acquired heart disease in 13. The valve replaced was mitral in 15 children, aortic in 11, tricuspid in 3, and combined aortic and mitral in 1. Twenty-one mechanical and 10 tissue valves were placed: primary mechanical valve have been utilized since 1985. Eight of ten patients with tissue valves have had successful second valve replacements 4 to 11 years after the initial operation. Result: The operative mortality was 6.7%, but mortality was higher among patients less than 5 years of age and patients who had previous cardiac operations. Of the 28 operative survivors, 4 patients were lost to follow-up: the remaining patients were observed for a total of 2091 patient/months(mean 74.7 months, maximum 187 months). There was one late death from dilated cardiomyopathy after mitral valve replacement in 7 year-old patient with atrioventricular septal defect. After the operation, all patients with mechanical valves were placed on a strict anticoagulant regimen with Coumadin. The actuarial survival rate was 96% at the end of the follow-up. No instance of thromboembolism or major bleeding were observed in the survivors. Conclusion: These results indicate that valve replacement can be performed with low mortality in children, and with satisfactory long-term survival.

  • PDF

Post-Infarction Ventricular Septal Rupture : 10 Years of Experience (급성 심근경색증 후 심실중격 결손: 10년 경험)

  • Jung, Yo-Chun;Cho, Kwang-Ree;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.40 no.5 s.274
    • /
    • pp.351-355
    • /
    • 2007
  • Background: Postinfarction ventricular septal rupture is associated with mortality as high as $85\sim90%$, if it is treated medically. This report documents our experience with postinfarction ventricular septal rupture that was treated surgically, Material and Method: We retrospectively reviewed the medical records of 11 patients who were operated on due to postinfarction ventricular septal rupture between August 1996 and August 2006. There were 4 men and 7 women, with a mean age of $70{\pm}11$ years (age range: $50\sim84$ years). The location of the rupture was anterior in 7 cases and posterior in 4 cases. The interval between the onset of acute myocardial infarction and the occurrence of the ventricular septal rupture was $2.0{\pm}1.3$ days (range: $1\sim5$ days). Operation was performed at an average of $2.4{\pm}2.7$ days (range: $0\sim8$ days) after the diagnosis of septal rupture. Preoperative intraaortic balloon pump therapy was performed in 10 patients. Result: The infarct exclusion technique was used in all cases. Coronary artery bypass grafting was done in 8 cases, with the mean number of distal anastomosis being $1.0{\pm}0.8$. There was one operative death. In 2 patients, reoperation was performed due to a residual septal defect. The postoperative morbidities were transient atrial fibrillation (n=7), paroxysmal supraventricular tachycardia (n=1), low cardiac output syndrome (n=3), bleeding reoperation (n=2), delayed sternal closure (n=2), acute renal failure (n=2), pneumonia (n=1), intraaortic balloon pump-related thromboembolism (n=1), and transient delirium (n=2). Nine patients have been followed up for a mean of $38{\pm}40$ months except for one follow-up loss. There have been 3 late deaths. At the latest follow-up, all 6 survivors were in a good functional class. Conclusion: We demonstrated satisfactory operative and midterm results with our strategy of preoperative intraaortic balloon pump therapy, early repair of septal rupture by infarct exclusion and combined coronary revascularization.

The Clinical Outcome of Pulmonary Thromboendarterectomy for the Treatment of Chronic Pulmonary Thromboembolism (만성 폐동맥 색전증 환자에서의 폐동맥 내막절제술의 임상적 결과)

  • Bang, Jeong-Hee;Woo, Jong-Soo;Choi, Pil-Jo;Jo, Gwang-Jo;Park, Kwon-Jae;Kim, Si-Ho;Yie, Kil-Soo
    • Journal of Chest Surgery
    • /
    • v.43 no.3
    • /
    • pp.254-259
    • /
    • 2010
  • Background: Diagnosing chronic pulmonary embolism at an early stage is difficult because of the patient’s nonspecific symptoms. This condition is not prevalent in Korea, and in fact, there have been only a few case reports on this in the Korean medical literature. We analyzed the surgical outcome of performing pulmonary thromboendarterectomy in patients with chronic pulmonary embolism. Material and Method: The study subjects included those patients who underwent surgery for chronic pulmonary embolism from 1996 to 2008. For making the diagnosis, echocardiography, chest CT and a pulmonary perfusion scan were performed on the patients who complained of chronic dyspnea. Result: Pulmonary endarterectomy was performed as follows: by incision via a mid-sternal approach (7 patients); by incision via a left posterolateral approach (1 patient); using the deep hypothermic circulatory arrest technique (4 patients); under ventricular fibrillation (3 patients); and under cardioplegic arrest (1 patient). The postoperative systolic pulmonary artery blood pressure significantly decreased from a preoperative value of $78.9{\pm}14.5\;mmHg$ to $45.6{\pm}17.6\;mmHg$ postoperatively (p=0.000). The degree of tricuspid regurgitation was less than grade II after surgery. Two patients died early on, including one patient who had persistent pulmonary hypertension without improvement and right heart failure. Conclusion: Patients who have chronic pulmonary embolism are known to have a poor prognosis. However, we think that early surgical treatment along with making the proper diagnosis before the aggravation of right heart failure can help improve the quality of a patient's life.

Low-intensity Oral Anticoagulation Versus High-intensity Oral Anticoagulation in Patients with Mechanical Bileaflet Prosthetic Heart Valves (이엽성 기게 심장판막 환자에 대한 낮은 강도의 항응고제 요법의 결과에 대한 임상분석)

  • Jeong, Seong-Cheol;Kim, Mi-Jung;Song, Chang-Min;Kim, Woo-Shik;Shin, Yong-Chul;Kim, Byung-Yul
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.430-438
    • /
    • 2008
  • Background: All the patients with mechanical valves require warfarin therapy in order to prevent them from developing thromboembolic complications. According to the ACC/AHA practice guidelines, after AVR with bileaflet mechanical prostheses in patients with no risk factors, warfarin is indicated to achieve an INR of 2.0 to 3.0. After MVR with any mechanical valve, warfarin is indicated to achieve an INR of 2.5 to 3.5. But in our clinical experience, bleeding complications (epistaxis, hematuria, uterine bleeding, intracerebral hemorrhage etc.) frequently developed in patients who maintained their INR within this value. So, we retrospectively reviewed the patients with bileaflet mechanical heart valve prosthesis and we determined the optimal anticoagulation value. Material and Method: From January 1984 to February 2007, 311 patients have been followed up at a national medical center. We classified the AVR patients (n=60) into three groups as follows: an INR from 1.5 to 2.0 in Group I, an INR from 2.0 to 2.5 in Group II and an INR from 2.5 to 3.0 in Group III. We classified the MVR (n=171) and DVR (n=80) patients into four groups as follows: an INR from 1.5 to 2.0 in Group I, an INR from 2.0 to 2.5 in Group II, an INR from 2.5 to 3.0 in Group III and an INR from 3.0 to 3.5 in Group III. We compared the groups for their thromboembolic and bleeding complications by means of the Kaplan Meier method. Result: In the AVR patients, 2 thromboembolic complications and 4 bleeding complications occurred and the log rank test failed to identify any statistical significance between the groups for thethromboembolic complication rate, but groups I and II had lower bleeding complication rates than did group III. Thirteen thromboembolic complication and 15 bleeding complication occurred in the MVR and DVR patients, and the log rank test also failed to identify statistical significance between the groups for the thromboembolic complication rate, but groups I and II had lower bleeding complication rates that did groups III and IV. Conclusion: The thromboembolic complication rate was not statistically different between groups I and II and groups III and IV, but the bleeding complication rates of groups I and II were lower than those of groups III and IV. So this outcome encouraged us to continue using our low intensive anticoagulation regime, that is, an INR of 1.5 to 2.5.

Staged Fontan Operation Via Bidirectional Glenn Operation (양방향성 GLENN 수술을 통한 단계적 FONTAN 수술의 임상분석)

  • 한재진;김웅한
    • Journal of Chest Surgery
    • /
    • v.30 no.11
    • /
    • pp.1062-1068
    • /
    • 1997
  • From August 1989 to January 1996, a total of 105 cases of bidirectional Glean operations have been done as the interim stage for the patien s with some risk of univentricular correction at Sejong General Hospital. From December 1992, we started the conversion to Fontal operations for them, and 42 cases underwent Fontal-stage operation till February 1996. Their diagnoses were univentricular heart in 19(right ventricular type : 14), tricuspid atresia 11, double outlet of right ventricle 9, and others in 3 cases. The median age of bidirectional Glerln-stage operation was 12.5 months(range 2 months to 8 years) and Fontan-stage operation was at 59.6 months of median age(range 1 year 5 months to ,9 year 7 months). The mean waiting interval between the two operations was 33.88 $\pm$ 17.85 months with a range of 10 months to 6 years 3 months. During the waiting periods, 18 patients developed significant systemic-pulmonary collaterals andfor systemic verso-veno collateral channels. There were 5 hospital deaths after operations due to low cardiac output in 4 and sepsis in one. Most of the Fontal-stage operations were done by the late al tunneling with Core-Tex tube graft patch and fenestrated with the size of 2.5 ~6 mm. All the patients were followed-up(7 months to 4 years 2 months, mean 21.97$\pm$10.82 months) and there were 5 late deaths(postoperatively 6 months to 2 years) due to thromboembolism in 1, after heart transplantation 1, plastic bronchitis 1, protein loosing enteropathy 1, and pneumonia in 1. Dividing the patients by the waiting interval of 2 years, the early correction to Fontal group (N=16) showed the better results(hospital mortality 1116, late mortality 1116, significant collateral development 2/16) compared to the other group(N=26) (4/26, 4/26, 16/26). In conclusion, after the bidirectional Glean-stage operation successfully got rid of the previous risk factors, we recommand to do the Fontan-stage operation no later than 2 years of interval.

  • PDF

The Long-term Clinical Result of St. Jude Mechanical Valve Replacement (St. Jude 기계판막 치환술의 장기 임상성적)

  • 배윤숙;정성철;김우식;정승혁;유환국;이정호;김병열
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.321-328
    • /
    • 2003
  • Background: The St. Jude Medical prosthesis is one of the popularly used artificial prosthesis, therefore the National Medical Center reports the long-term clinical results of patients who underwent prosthetic valve replacement with St. Jude medical valve for 18 years. Material and Method: Between January, 1984 and June, 2002, a series of 163 consecutive patients who had Implanted St. Jude prosthesis at the National Medical Center were reviewed. Mean age was 42.9$\pm$15.1 years and male to female ratio was 69:94. The operative procedure comprised of 87 MVR, 30 AVR, 45 DVR, and 1 TVR. The reoperative procedure comprised of 21 MVR, 2 AVR, and 14 DVR. Follow-up rate was 96.9%, and cumulative follow-up was 823.8 patient-years. Result: Early mortality rate was 7.9% (13 patients), late mortality rate was 8.7% (13 patients) and late mortality due to valve related complication was 47% (7 patients). Actual survival rate at 10 and 18 years were 91.7$\pm$2.1% and 91.0$\pm$1.9%. Linearized Incidence was as follows: thromboembolism, 1.09%/ patient-year; anticoagulant related hemorrhage, 0.36%/patient-year; valve thrombosis, 0.24%/patient-year; paravalvular leakage, 0.12%/patient-year; and prosthetic bacterial endocarditis, 0.12%/patient-year linearized incidence of over all valve related complication was 1.94%/patient-year. Freedom from valve related complication at 10 and 18 years were 89.1$\pm$3.3% and 88.4$\pm$3.9%. Freedom from valve related death at 10 and 18 years were 95.1$\pm$1.2% and 95.1$\pm$1.0%. Valve related complication was related the age of patient, especially anticoagulant related hemorrhage was more common in patients over 60 years of age. Valve related complication, death were higher in DVR than AVR or MVR, and valve related death was higher in reoperation. There was no relationship between valve related complication or death and implant valve of size. Conclusion: The long-term clinical results of patients implanted with St. Jude Mechanical prosthesis was quite satisfactory with a low incidence of valve related complication and mortality.

Alteration of Coagulation and Fibrinolysis System According to Right Ventricular Dysfunction in Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환에서 우심실 기능 부전에 따른 혈액응고 및 섬유소용해계 변화)

  • Kim, Young;Jang, Yoon Soo;Kim, Hyung Jung;Kim, Se Kyu;Chang, Joon;Ahn, Chul Min;Kim, Sung Kyu;Kwak, Jin Young;Choi, Jin Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.6
    • /
    • pp.625-630
    • /
    • 2006
  • Background: Pulmonary hypertension in COPD patients is the result of a direct effect of tobacco smoke on the intrapulmonary vessels with the abnormal production of the mediators that control vasoconstriction, vasodilatation, and vascular cell proliferation, which ultimately lead to aberrant vascular remodeling and physiology. COPD patients are prone to the developmint of an acute and chronic thromboembolism with an elevation of the plasma procoagulant and fibrinolytic markers However, the roles of the coagulation and fibrinolysis system on the right ventricular dysfunction in COPD patients are not well defined. We examined the alteration of the coagulation and fibrinolysis system in COPD patients according to the right ventricular function measured using cardiac multidetector computed tomography (MDCT). Methods: The right ventricular ejection fraction (RVEF) was measured using cardiac MDCT in 26 patients who were diagnosed with COPD according to the definition of the GOLD guideline. The plasma level of thrombin antithrombin (TAT) and plasminogen activator inhibitor (PAI)-1 were measured using an enzyme linked immunoassay. Results: The plasma TAT was markedly elevated in COPD patients ($10.5{\pm}19.8{\mu}g/L$) compared with those of the control ($3.4{\pm}2.5{\mu}g/L$) (p<0.01). However, the plasma PAI-1 in COPD patients ($29.6{\pm}20.7ng/mL$) was similar to that in the controls. The plasma TAT showed a significant inverse relationship with the RVEF measured by the cardiac MDCT in COPD patients (r=-0.645, p<0.01). However, the plasma PAI-1 did not show a relationship with the RVEF (r=0.022, p=0.92). Conclusion: These results suggest that the coagulation system in COPD patients is markedly activated, and that the plasma level of TAT might be a marker of a right ventricular dysfunction in COPD patients.