• Title/Summary/Keyword: Threshold limit values

Search Result 57, Processing Time 0.027 seconds

A study on the criteria and supply status of information for managing carcinogens in domestic and foreign (국내외 발암성물질의 관리기준과 정보제공 현황에 관한 연구)

  • Lee, Kwon Seob;Lee, Jong Han;Lee, Hye Jin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.1
    • /
    • pp.40-48
    • /
    • 2011
  • This study was intended to resolve problems caused by different classification criteria and management methods of carcinogenicity, which have made industrial safety & health institutions and business employers difficult to execute projects or to carry out occupational safety and health related works, and have affected how civic groups perceive carcinogens. The content of this study contained the comparison of management and categorization standards for carcinogens between Korea and other countries as well as the current carcinogenicity-related information supply status of each professional institution. Furthermore, this research examined the current state of supplying information on carcinogenicity among major institutional information supply according to the categorization standard for carcinogens by UN GHS, Ministry of Employment and Labor in Korea(KMoEL), and GHS MSDS provided by Korea Occupational Safety & Health Agency(KOSHA). Now, professional agency provide 927 kinds of IARC, 237 kinds of NTP, 351 kinds of ACGIH and 1,006 kinds of EU ECHA information on carcinogenic agents. KMoEL provides carcinogenicity-related information of 58 chemical agents in accordance with the category of carcinogens guided by ACGIH. KOSHA offers 13,232 kinds of GHS MSDS information including 2,484 carcinogenic substances. Therefore, carcinogenicity-related information of chemical substances, which are not available on the existing GHS MSDS DB, should be updated for the future reference.

A Study on Breakthrough of Respirator Cartridge Using Multi-Organic Vapor Mixtures (복합유기용제에 노출된 호흡보호구용 정화통의 파과에 관한 연구)

  • Chung, Hai-Dong;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.55-66
    • /
    • 1996
  • This study was conducted to evaluate breakthrough characteristics of respirator cartridge using multi-organic vapors, including carbon tetrachloride, trichloroethylene, and toluene. The organic vapors were used as single phase, binary system, and ternary system. The results are summarized as follows. 1. Organic vapors studied were 1,000 ppm, 750 ppm, 500 ppm and 250 ppm in single phase. Carbon tetrachloride having the highest molecular weight showed the breakthrough first, and breakthrough sequency by organic vapor was dependent on its molecular weight. The 10% breakthrough times at 1,000 ppm of organic vapor were 97 minutes for carbon tetrachloride, 129 minutes for trichloroethylene and 135 minutes for toluene. 2. When concentrations of organic vapors were at levels of the Threshold Limit Values, the lives of the respirator cartridges were 122 hours in carbon tetrachloride, 18 hours in trichloroethylene and 28 hours in toluene. 3. In the binary system at a total concentration of 1,000 ppm with carbon tetrachloride and trichloroethylene, breakthrough times ranged from 104 minutes to 125 minutes, which were longer than 97 minutes in a single phase (1,000 ppm) for carbon tetrachloride, but shorter than breakthrough times for TCE and Toluene. 4. Breakthrough times in the binary system with carbon tetrachloride and toluene were 131~132 minutes. 5. Breakthrough times in the ternary system with carbon tetrachloride, toluene, and trichloroethyl ene were $120{\pm}8$ minutes, which were longer than 97 minutes in the single phase (1,000 ppm) for carbon tetrachloride, equal to 129 minutes for trichloroethylene, and shorter than 135 minutes for toluene. Those were almost similar to $124{\pm}9$ minutes of breakthrough times in the binary systems.

  • PDF

Assessment of Semen Quality among Workers Exposed to Heat Stress: A Cross-Sectional Study in a Steel Industry

  • Hamerezaee, Masoud;Dehghan, Somayeh F.;Golbabaei, Farideh;Fathi, Asad;Barzegar, Loghman;Heidarnejad, Naseh
    • Safety and Health at Work
    • /
    • v.9 no.2
    • /
    • pp.232-235
    • /
    • 2018
  • Background: This study was conducted to investigate the heat stress and semen quality among male workers in a steel industry in Iran and investigate the relationship between heat stress indices and semen parameters. Methods: The study was conducted on workers exposed (n = 30) and unexposed (n = 14) to heat in a steel industry. After obtaining a brief biography of the selected employees, scrotal temperature, oral temperature, and environmental parameters were measured, and their semen samples were analyzed according to the procedure recommended by the World Health Organization. The heat stress indices, including wet-bulb globe temperature (WBGT) and predicted heat strain (PHS), in their workplace were calculated according to environmental parameters (ISO 7243:1989 and 7933:2004, respectively). Results: Time-weighted averages of WBGT and PHS ($35.76^{\circ}C$ and 491.56 $w/m^2{\frac{w}{m^2}}$, respectively) for the exposed group were higher than threshold limit values. The mean difference of environmental, physiological, and semen parameters (exception: pH of semen), and also WBGT and PHS indices were statistically significant (p < 0.05) between the two groups. Mean semen parameters were in the normozoospermic range. WBGT and PHS indices showed significantly "negative" correlation with physiological parameters (scrotal and oral temperature) and most semen parameters (semen volume, sperm morphology, sperm motility, sperm count; p < 0.05); moreover, the correlation of WBGT with these parameters was stronger than PHS. Conclusion: Semen parameters of the studied workers exposed to heat were in the borderline level of normozoospermic range, and their semen parameters were significantly lower than controls. For better assessment of occupational environment concerning physiological and semen parameters in steel industries, WBGT can be a more useful index.

Micro Sensor Away and its Application to Recognizing Explosive Gases (마이크로 센서 어레이 제작 및 폭발성 가스 인식으로의 응용)

  • 이대식;이덕동
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.1
    • /
    • pp.11-19
    • /
    • 2003
  • A micro sensor array with 4 discrete sensors integrated on a microhotplate was developed for identifying the kinds and quantities of explosive gases. The sensor array consisited of four tin oxide-based thin films with the high and broad sensitivity to the tested explosive gases and uniform thermal distribution on the plate. The microhotplate, using silicon substrate with N/O/N membrane, dangling in air by Al bonding wires, and controlling the thickness by chemical mechanical process (CMP), has been designed and fabricated. By employing the sensitivity signal of the sensor array at 40$0^{\circ}C$, we could reliably classily the kinds and quantities of the explosive gases like butan, propane, LPG, and carbon monoxide within the range of threshold limit values (TLVs), employing principal component analysis (PCA).

Study on the Validity of Selection of Hazardous Substances Requiring Management on Industrial Safety and Health Act (산업안전보건법에 의한 관리대상 유해물질 선정의 타당성 연구)

  • Lee, Kwon Seob;Jo, Jihoon;Choi, Jin Hee;Shin, Hyun Hwa;Yang, Jeong Sun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.2
    • /
    • pp.139-152
    • /
    • 2009
  • According to the third study on the distribution of chemical substances carried out by the Department of Environment in 2006, there were a total of 900 chemical substances whose respective annual usage amount exceeded 1,000 tons and, among them, 90 substances belonged to the 168 hazardous substances requiring management(53.6%). The work-related illnesses caused by hazardous substances requiring management in Korea between $1992{\sim}2005$ can be classified into four groups depending on the type of the chemical substances. These four groups are 23 organic substances including benzene, 12 metals including lead, 3 acids and bases including hydrogen chloride, and 6 gaseous substances including carbon monoxide. These hazardous substances requiring management were again classified depending on the threshold limit values. The chemicals whose TLV was lower than or equal to 0.005 ppm included 4 organic substances including methylene bisphenyl isocyanate and toluene-2,4-diisocyanate (TDI). The chemicals whose TLV was larger than 51 ppm included 22 organic substances including diethyl ether and 1,2-dichloroethylene. When we classified these hazardous substances requiring management according to the categories of GHS health hazards, we found that isobutyl acetate and magnesium oxide didn't belong to the 13 health hazard categories. Among the substances whose TLV is set and whose annual usage amount is more than 0.1 million ton, we recommended 12 chemical species including 4,4'-Methylenedianiline as new hazardous substances requiring management. All the recommended substances were found to be hazardous when we classified their health hazards.

Whole-body Vibration Exposure of Drill Operators in Iron Ore Mines and Role of Machine-Related, Individual, and Rock-Related Factors

  • Chaudhary, Dhanjee Kumar;Bhattacherjee, Ashis;Patra, Aditya Kumar;Chau, Nearkasen
    • Safety and Health at Work
    • /
    • v.6 no.4
    • /
    • pp.268-278
    • /
    • 2015
  • Background: This study aimed to assess the whole-body vibration (WBV) exposure among large blast hole drill machine operators with regard to the International Organization for Standardization (ISO) recommended threshold values and its association with machine- and rock-related factors and workers' individual characteristics. Methods: The study population included 28 drill machine operators who had worked in four opencast iron ore mines in eastern India. The study protocol comprised the following: measurements of WBV exposure [frequency weighted root mean square (RMS) acceleration ($m/s^2$)], machine-related data (manufacturer of machine, age of machine, seat height, thickness, and rest height) collected from mine management offices, measurements of rock hardness, uniaxial compressive strength and density, and workers' characteristics via face-to-face interviews. Results: More than 90% of the operators were exposed to a higher level WBV than the ISO upper limit and only 3.6% between the lower and upper limits, mainly in the vertical axis. Bivariate correlations revealed that potential predictors of total WBV exposure were: machine manufacturer (r = 0.453, p = 0.015), age of drill (r = 0.533, p = 0.003), and hardness of rock (r = 0.561, p = 0.002). The stepwise multiple regression model revealed that the potential predictors are age of operator (regression coefficient ${\beta}=-0.052$, standard error SE = 0.023), manufacturer (${\beta}=1.093$, SE = 0.227), rock hardness (${\beta}=0.045$, SE = 0.018), uniaxial compressive strength (${\beta}=0.027$, SE = 0.009), and density (${\beta}=-1.135$, SE = 0.235). Conclusion: Prevention should include using appropriate machines to handle rock hardness, rock uniaxial compressive strength and density, and seat improvement using ergonomic approaches such as including a suspension system.

Occupational exposure to dust and respirable quartz in coal briquettes ash handling worker (연탄재 처리 환경미화원의 분진 및 호흡성 석영 노출)

  • Kim, Boowook
    • Particle and aerosol research
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • The purpose of this study is to assess respirable crystalline silica (RCS) exposure levels in workers who collect and dispose used coal briquette ash (CBA) in sanitation companies that are subcontracted by one medium-sized local government on the collection of municipal household waste (MHW), and to analyze the quartz content in CBA. When the CBA powder that undergone specialized pretreatment in several steps were subjected to mineral identification and quantitative analysis using X-ray diffraction (XRD), it was found that quartz represented 18%, and in addition, mullite, and plagioclase were included. For two CBA collectors, samples were collected by the personal sampling evaluation method. After respirable dust was collected in accordance with the National Institute for Occupational Safety and Health 7500 method, the concentration of quartz was analyzed using XRD. Meanwhile, a portable real-time dust monitor (Sidepak AM520, TSI Inc., USA) was also used to observe the dust exposure level for each time zone and job task. The RCS exposure level of one worker was as high as 0.024 mg/㎥, which was the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Values (TLV) level. The other worker also exhibited a concentration of 0.013 mg/㎥, which was more than half of TLV. The Sidepak results revealed that the work of collecting CBA and loading it onto a vehicle was hardly exposed to the dust of a significant level. It was found, however, that the work of transferring the collected CBA to a container through a conveyor belt was exposed to a very high average respirable dust concentration of 2.238 mg/㎥. The results of this study confirmed that quartz, which is crystalline silica and a carcinogen, is contained in CBA, one of municipal household waste (MHW), in high concentration. It was also confirmed that workers are exposed to high RCS concentrations while transferring collected CBA into a container. Although each local government in South Korea handles CBA in different ways, it is imperative to investigate the CBA exposure level of sanitation workers and improve their working conditions.

Establishment of Acceptable Daily Intakes (ADIs) and Risk Assessment for Ephedrine, Menichlopholan, Anacolin, and Etisazole Hydrochloride

  • Min Ji Kim;Ji Young Kim;Jang Duck Choi;Guiim Moon
    • Korean Journal of Environmental Agriculture
    • /
    • v.41 no.4
    • /
    • pp.261-275
    • /
    • 2022
  • BACKGROUND: Prior to implementing a positive list system (PLS), there is a need to establish acceptable daily intake (ADI) and maximum residue limit (MRL) for veterinary drugs that have been approved a few decades ago in South Korea. On top of that, chronic dietary exposure assessment of veterinary drug residues should be performed to determine whether the use of these veterinary drugs would cause health concerns or not. METHODS AND RESULTS: To establish the ADI, the relevant toxicological data were collected from evaluation reports issued by international organizations. A slightly modified global estimate of chronic dietary exposure (GECDE) model was employed in the exposure assessment owing to the limited residual data. Therefore, only the ADI of ephedrine was established due to insufficient data for the other veterinary drugs. Thus, instead of ADI, the threshold of toxicological concern (TTC) value was used for the other drugs. Lastly, the hazard index (HI) was calculated, except for etizazole hydrochloride, due to the potential of mutagenicity. CONCLUSION(S): The HI values of ephedrine, menichlopholan, and anacolin were found to be as high as 6.4%, suggesting that chronic dietary exposure to the residues from these uses was unlikely to be a public health concern. Further research for exposure assessment of veterinary drug residues should be performed using up-todate Korean national health and nutrition examination survey (KNHANES) food consumption data. In addition, all relevant available data sources should be utilized for identifying the potentials of toxicity.

A Study on Composition of Solvent Thinners and Evaporation in the Air (일부 신나의 구성성분과 공기중 증발에 관한 연구)

  • Zoh, Kyung Ehi;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.245-263
    • /
    • 1997
  • For twelve solvent thinners, evaporation rates of components were investigated and models to estimate the actual concentration have been evaluated. Also, the current ACGIH TLVs (Threshold Limit Values) for the concentration of organic mixtures have been adjusted. The results of this study are summarized as follows : 1. Airborne concentrations of solvent thinner components were related to their respective vapor pressure (r=0.96). On the other hand, there was no significant relation between the concentrations in the air of the thinner compounds and the original amount in liquid form. 2. Airborne concentrations of each chemical were estimated by temperature at $8.5{\pm}1$, $16.7{\pm}1$ and $31.5{\pm}2^{\circ}C$ with an air velocity of 1.5 m/s. The concentrations were increased by increasing temperature (p<0.05). The percentage of concentrations were proportionate to their respective percentage of vapor pressure. Among the chemicals studied, n-butyl acetate, n-butyl alcohol, m-xylene, p-xylene and o-xylene showed a clear relationship to temperature. 3. Airborne concentration of each chemical was estimated by air velocity at 0.05, 1.50 and 2.50 m/s, with a constant temperature at $17{\pm}2^{\circ}C$. The concentrations were increased by increasing air velocity (p<0.05). The percentage of concentrations were proportionate to their respective percentage of vapor pressure. Among the chemicals studied, n-butyl alcohol, m-xylene and p-xylene showed a clear relationship to velocity. 4. In estimating the concentrations of solvent thinners by temperature and air velocity, ACGIH TLVs for mixtures tended to be larger than the values obtained by ACGIH exposure index. It shows that ACGIH TLVs for mixtures are not adequate for evaluating the airborne concentration of thinners and other organic mixtures. 5. The evaporation rate of the thinners were compared to the theoretical equations of Hummel, Braun and Mackay. The Hummel and Braun methods were close to exposure index but Makay's showed an underestimated value. In order to see the accuracy of each three models, the SSE (Error Sum of Squares) calculated for Hummel's was 1.73, being the closest to the actual values. 6. Present ACGIH TLVs for mixtures are not appropriate evaluate industrial environments. In this study, a correction of TLVs using vapor pressure of respective components was suggested. In order to evaluate the corrected TLVs a paired t-test was performed. There was no significant difference between the exposure index and the concentration over suggested TLVs (p>0.05). Thus, this corrected TLVs seem appropriate in order to evaluate actual industrial workplaces organic chemical concentration in the air.

  • PDF

Analysis Program for Diffusion Model: SNUDM (확산모형 분석도구: SNUDM)

  • Koh, Sungryong;Choo, Hyeree;Lee, Dajung
    • Korean Journal of Cognitive Science
    • /
    • v.31 no.1
    • /
    • pp.1-23
    • /
    • 2020
  • This paper introduces SNUDM, an analysis program for Ratcliff's diffusion model, which has been one of the most important models in cognitive psychology over the past 35 years and which has come to occupy an important place in cognitive neuroscience in recent years. The analysis tool is designed with the basic principles of easy comprehension and simplicity in use. A diffusion process was programmed as the limit of a simple random walk in a manner resembling Ratcliff & Tuerlinckx(2002). The response time distribution of the model was constructed by simulating the time taken by a random walk until it reaches a threshold with small steps. The optimal parameter values in the model are found to be the smallest value of the chi-square values obtained by comparing the resulting distribution and the experimental data using Simplex method. For simplicity and ease of use, the input file used here is created as a file containing the quantile of the reaction time, the trials and other information. The number of participants and the number of conditions required for such work programs are given in a way that answers the question. Using this analysis tool, the experimental data of Ratcliff, Gomez, & McKoon(2004) were analyzed. We found the very similar pattern of parameter values to Ratcliff et al.(2004) found. When comparing DMAT, fast-dm and SNUDM with the generated data, we found that when the number of trials is small, SNUDM estimates the boundary parameter to a value similar to fast-dm and less than the DMAT. In addition, when the number of trials was large, it was confirmed that all three tools estimate parameters similarly.