• Title/Summary/Keyword: Three-level (TL)

Search Result 20, Processing Time 0.033 seconds

A Study on the Secondary Rectification-Methods for the Three-Level Converter

  • Bae, Jin-Yong;Kim, Yong
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.81-88
    • /
    • 2007
  • This paper proposes a coupled inductor-based rectifier of a Three-Level (TL) DC/DC converter and compares the rectification methods of a TL converter. The CICDR- TL (Coupled Inductor Current Doubler Rectifier Three-Level) converter achieves ZVS (Zero Voltage Switching) for the switches in a wide load range. CDR (Current Doubler Rectifier) and CICDR Three-Level converter have low voltage and current ripple. Advantages and disadvantages of topology compared to the rectifier of bridge, center-tap, CDR, and CICDR are discussed. Experimental estimation results are obtained on a 27V, 60A DC/DC TL converter prototype for the 1.8kW, 40kHz IGBT based experimental circuit.

A study on the CICDR-TL(Coupled Inductor Current Doubler Rectifier-Three Level) DC/DC Converter with Phase Shift Control (위상이동 방식을 적용한 CICDR-TL(Coupled Inductor Current Doubler Rectifier-Three Level) DC/DC 컨버터에 관한 연구)

  • Lee, Dong-Hyun;Kim, Yong;Bae, Jin-Yong;Kim, Pill-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.159-162
    • /
    • 2004
  • The paper proposes the coupled inductor rectifier of Three Level DC/DC converter CICDR-TL(Coupled Inductor Current Doubler Rectifier-Three Level) achieves Zero Voltage Switching (ZVS) for the switches in a wide load range and Zero Current Switching (ZCS) in a light load range. Advantages and disadvantages of this topology compared to the conventional Center Tapped TL Converter are discussed. Experimental evaluation results obtained on a 27V 60A DC/DC converter prototype for the 1.8kW 40kHz IGBT based experimental circuit.

  • PDF

Full ZVS Load Range Diode Clamped Three-level DC-DC Converter with Secondary Modulation

  • Shi, Yong
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.93-101
    • /
    • 2016
  • A new four-primary-switch diode clamped soft switching three-level DC-DC converter (TLDC) with full zero-voltage switching (ZVS) load range and TL secondary voltage waveform is proposed. The operation principle and characteristics of the presented converter are discussed, and experimental results are consistent with theoretical predictions. The improvements of the proposed converter include a simple and compact primary structure, TL secondary rectified voltage waveform, wide load range ZVS for all primary switches, and full output-regulated range with soft switching operation. The proposed converter also has some disadvantages. The VA rating of the transformer is slightly larger than that of conventional TLDCs in variable input and constant output mode. The conduction loss of the primary coil is slightly higher because an air gap is inserted into the magnetic cores of the transformer. Finally, the secondary circuit is slightly complex.

Leg-By-Leg-Based Finite-Control-Set Model Predictive Control for Two-Level Voltage-Source Inverters

  • Zhang, Tao;Chen, Xiyou;Qi, Chen;Lang, Zhengying
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1162-1170
    • /
    • 2019
  • Finite-control-set model predictive control (FCS-MPC) is a promising control scheme for two-level voltage-source inverters (TL-VSIs). However, two main issues arise in the classical FCS-MPC method: an exponentially-increasing computational time and a low steady-state performance. To solve these two issues, a novel FCS-MPC method has been proposed for n-phase TL-VSIs in this paper. The basic idea of the proposed method is to carry out the FCS-MPC scheme of TL-VSIs for one leg by one leg, like a "pipeline". Based on this idea, the calculations are reduced from exponential time to linear time and its current waveforms are improved by applying more switching states per sampling period. The cases of three-phase and five-phase TL-VSIs were tested to verify the effectiveness of proposed method.

A New Zero-Voltage Switching Three-Level Converter with Reduced Rectifier Voltage Stress (결합 인덕터를 적용한 고효율 3레벨 컨버터)

  • Kim, Keon-Woo;Han, Jung-Kyu;Moon, Gun-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.6
    • /
    • pp.406-410
    • /
    • 2019
  • Three-level (3L) DC-DC converters are appropriate for high-input-voltage applications. Although the voltage stress of TL converter switches can be reduced to half of the input voltage, the primary side has a large circulating current, which degrades efficiency. In this study, a dual half-bridge cascaded TL converter is presented to reduce this circulating current and thus decrease the conduction loss of the primary circuit. Moreover, the proposed converter can reduce the voltage stress of rectifier diodes, thereby reducing their conduction loss. Therefore, efficiency can be improved by reducing the conduction loss of the primary circuit and rectifier diodes.

The Measurement and Analysis of LiF:Mg, Cu, Na, Si TL Material by Thermoluminescence Spectrum (LiF:Mg, Cu, Na, Si TL 물질의 열자극발광스펙트럼 측정 및 분석)

  • Lee, J.I.;Moon, J.H.;Kim, D.H.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.149-153
    • /
    • 2001
  • Three-dimensional thermoluminescence(TL) spectra of LiF: Mg, Cu, Na, Si TL material based on temperature, wavelength and intensity were measured and analyzed. The glow curves were obtained by integration of luminescence intensity for wavelength at each temperature, and various trapping parameters related to the trap formation were determined by analyzing these curves. Computerized glow curve deconvolution(CGCD) method which based on general order kinetics(GOK) model were used for the glow curve analysis. The glow curves of LiF:Mg, Cu, Na, Si TL material were deconvoluted to six isolated glow curves which have peak temperature at 333 K, 374 K, 426 K, 466 K, 483 K and 516 K, respectively. The 466 K main glow peak had an activation energy of 2.06 eV and a kinetic order of 1.05. This TL material was also found to have three recombination centers, 1.80 eV, 2.88 eV and 3.27 eV by TL spectra analysis based on Franck-Condon model. It showed that 2.88 eV is the dominant center, followed by 3.27 eV level, and 1.80 eV center is ascertained as emission center of this material even though its very weak emission intensity.

  • PDF

Lipid Metabolism of Korean Breast-Fed Formula-Fed Infants (모유영양아와 인공영양아의 지질 대사)

  • 임현숙
    • Journal of Nutrition and Health
    • /
    • v.27 no.5
    • /
    • pp.429-441
    • /
    • 1994
  • The difference in lipid metabolism between breast-fed(BF) and formula-fed(FF) infants were studied in 31 Korean infants at 1, 2 and 3 months postpartum. The formulas had more total lipids(TL), triglycerides(TG) and phospholipids and less cholesterol(CHOL) and free fatty acids(FFA) than the breast milk. The milk consumption of the FF infants was significantly greater than that of the BF infants with a wide individual variation. As a result, the FF infants appeared to consume more TL, TG and PL and less CHOL and FFA than the BF infants during 3 months. The lipid contents of the breast milk tended to decrease in due course of lactation, therefore the intake of lipids of BF infants was reduced during the first three month of lactation. The plasma TG and CHOL levels of infants at 3 month were not significantly different between the BF and FF infants, but the PL level of the BF infants was higher then that of the FF infants. The plasma levels of TG and CHOL were not significantly correlated with the intakes of TL, TG, CHOL, PL and FFA, respectively. The PL level, however, was positively correlated with the intakes of CHOL and FFA, respectively and negatively correlated with PL intake as well as 18 : 2w6 fatty acid content of the breast milk or the formulas. The fecal weight and fecal loss of TL of the FF infants were greater than those of the BF infants during 3 months, however, apparent lipids digestibility was not significantly different between the BF and FF infants. The fecal excretions of CHOL and bile acids of FF infants were substantially higher than those of BF infants during 3 months. New sterol balance showed a particularly large difference between the BF and FF infants. The value of the net sterol balance of the BF infants was negative, but that of the FF infants was positive. This study shows that the consumption pattern of various lipid components of BF and FF infants were different as a result of different lipid compositions between breast milk and formula. The significantly lower sterol balance of the BF infants than the FF infants may have been derived from the unique dietary characteristic of breast milk.

  • PDF

Novel Buck Mode Three-Level Direct AC Converter with a High Frequency Link

  • Li, Lei;Guan, Yue;Gong, Kunshan;Li, Guangqiang;Guo, Jian
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.407-417
    • /
    • 2018
  • A novel family of Buck mode three-level direct ac converters with a high frequency link is proposed. These converters can transfer an unsteady high ac voltage with distortion into a regulated sinusoidal voltage with a low THD at the same frequency. The circuit configuration is constituted of a three-level converter, high frequency transformer, cycloconverter, as well as input and output filters. The topological family includes forward, push-pull, half-bridge, and full-bridge modes. In order to achieve a reliable three-level ac-ac conversion, and to overcome the surge voltage and surge current of the cycloconverter, a phase-shifted control strategy is introduced in this paper. A prototype is presented with experimental results to demonstrate that the proposed converters have five advantages including high frequency electrical isolation, lower voltage stress of the power switches, bi-directional power flow, low THD of the output voltage, and a higher input power factor.

Human-in-the-Loop Simulation Analysis of Integrated RPAS Operations in Trajectory Based Operations Environment

  • Oh, Hyeju;Kang, Jisoo;Kang, Seon-Young;Choi, Keeyoung;Lee, Hak-Tae;Jung, Hyuntae;Moon, Woo-Choon
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.4
    • /
    • pp.604-613
    • /
    • 2016
  • In this paper, Human-in-the-Loop (HiTL) simulations of Remotely Piloted Aircraft System (RPAS) operations in two different Air Traffic Management (ATM) concepts, conventional radar vectoring and Trajectory Based Operations (TBO), were performed to assess the impacts of RPAS integration in the future ATM environment. TBO concept maximizes the throughput by planning and sharing 4-D trajectories between pilots and controllers, and it is considered one of the key concepts to enable RPASs to operate with manned aircraft in congested airspaces. RPASs are characterized by having communication delay or temporary loss of communication. TBO capability was added to the integrated air traffic simulation system for this study, which was developed in the Inha University. HiTL simulations were performed by a trainee air traffic controller with three scenarios, and the data were analyzed using safety, efficiency, and controller workload metrics. The results suggest that TBO were effective in reducing delays and controller workload while maintaining the level of safety.

Glottal Parameters Contributing to the Perception of Loud Voices

  • Yi, So-Pae;Lee, One-Good;Kim, Hyung-Soon
    • Speech Sciences
    • /
    • v.8 no.1
    • /
    • pp.143-157
    • /
    • 2001
  • This paper focused on glottal parameters contributing to the perception of loud voices because energy of a voice is not the only effective factor. We used a formant synthesizer to synthesize loud voices. We divided F0 tilt (the tilt of F0 contour), SQ (Speed Quotient), OQ (Open Quotient) and TL (spectral Tilt Level) into three levels to get different combinations with default values for the other synthesizer parameters. Analysis of listening tests indicated that F0 tilt, SQ, OQ and TL in descending order had significant influence on the perception of loud voices. F0 tilt had a far more significant effect than the others. The influence of SQ increased greatly with the exclusion of F0 tilt as a factor. The interaction between parameters was not significant.

  • PDF