• 제목/요약/키워드: Three-dimensional Measurements

검색결과 698건 처리시간 0.022초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

ADCP 정지법 측정 시 미계측 영역의 유량 산정 정확도 분석 (Accuracy Analysis of ADCP Stationary Discharge Measurement for Unmeasured Regions)

  • 김종민;김서준;손근수;김동수
    • 한국수자원학회논문집
    • /
    • 제48권7호
    • /
    • pp.553-566
    • /
    • 2015
  • ADCP는 하천의 3차원 유속과 수심 자료를 매우 효율적이고 빠르게 측정할 수 있으며, 그 자료의 공간 및 시간적 해상도는 기존의 전통적인 유속 측정 방법들과 비교하여 매우 정밀하다는 장점이 있다. 하지만 ADCP는 하상 부근과 센서 근처에서의 미계측 영역이 발생하고 이 미계측 영역의 유속을 얼마나 정확하게 산정하느냐에 따라 ADCP 유량 측정의 정확도에 영향을 미친다. 본 연구에서는 ADCP 유량 산정 시 범용적으로 활용되고 있는 1/6 멱법칙(power law)을 활용한 미계측 영역의 유량 측정 결과의 정확도를 분석하였다. 이를 위해 실규모 직선수로에서 ADCP를 고정시킨 상태에서 측정한 유속 자료를 1/6 멱법칙과 대수 법칙(log law)을 적용하여 외삽 한 유속분포와 유량 산정 결과를 ADV를 이용하여 정밀하게 측정한 결과와 비교하였다. 비교 결과 전체적으로 대수 법칙으로 외삽한 경우가 높은 정확도를 나타냈으며, 수표면 근처 미계측 영역에서는 1/6 멱법칙은 유량을 작게 산정하는 경향을 나타냈고, 하상 근처의 미계측 영역에서는 유량을 크게 산정하는 경향을 나타냈다. 이 결과는 기존 1/6 멱법칙을 활용한 하상 및 수표면 부근 미계측 영역 유량 추정 방법이 오차를 수반함을 의미한다. 따라서 ADCP 정지법 측정 방식을 사용할 경우, 대수 법칙이 1/6 멱법칙보다 정확한 상하부 미계측 유량 추정 결과를 보여주었으므로 대안으로 고려되어야 할 것이다. 또한 제방 근처 미계측 영역의 유량 측정 정확도를 높이기 위해서는 수심이 0.6 m 이상을 확보한 측선을 기준으로 유량을 산정할 경우 신뢰도 높은 유량 측정 결과를 보였다. 향후, ADCP 정지법 측정 방식에 비해 보다 많이 활용되고 있는 보트탑재 이동식 ADCP의 경우도 이와 같은 검증이 필요하다고 하겠다.

전립선암에 대한 양성자치료에서 금마커에 의한 방사선 선량분포의 영향 (Dosimetric Influence of Implanted Gold Markers in Proton Therapy for Prostate Cancer)

  • 곽정원;신정욱;김진성;박성용;신동호;윤명근;박소아;김동욱;임영경;이세병
    • 한국의학물리학회지:의학물리
    • /
    • 제21권3호
    • /
    • pp.291-297
    • /
    • 2010
  • 본 연구에서는 양성자 치료에서 치료부위에 금 마커를 삽입하였을 때 양성자 빔의 선량과 그 분포에 미치는 영향을 평가하였다. 1.2 mm 직경에 3 mm 길이의 원통형 금 마커가 사용되었고 양성자 빔의 여러 위치에서 각각의 선량에 미치는 영향을 조사하였다. 3차원 moving 팬텀과 유효 반경이 0.5 mm인 정위적 방사선 치료용 다이로드 검출기를 이용하여 금마커의 방사선 선량으로의 영향을 결정하였다. Gafchromic film을 이용한 필름에 의한 선량 평가도 시행하였다. 그리고 선량-체적관계 히스토그램을 통한 분석을 위하여 GEANT4 전산 모의 도구 모음을 이용한 전산모의를 실시하였다. 마커의 움직임에 대한 영향성을 평가하기 위하여 직장 풍선을 적용하고 금 마커를 삽입한 10명의 환자에 대한 MV 영상을 이용하였다. 하나의 금 마커에 의하여 처방선량의 95% 이하가 들어간 체적은 0.15 cc로 작지만 그 체적은 치료부위 안쪽에 위치하고 평행이동에 대하여 발려져서 없어지지 않았다. 금 마커의 위치와 양성자 빔의 상태에 따라서 선량분포에 각각 다른 영향을 미치고 이는 임상치료에서 충분히 고려되어야 할 것으로 사료된다.

Elekta Synergy 선형가속기를 이용한 입체적세기조절회전방사선치료(VMAT) 정도관리 (Quality Assurance of Volumetric Modulated Arc Therapy for Elekta Synergy)

  • 심수정;심장보;이상훈;민철기;조광환;신동오;최진호;박성일;조삼주
    • 한국의학물리학회지:의학물리
    • /
    • 제23권1호
    • /
    • pp.33-41
    • /
    • 2012
  • 최근 환자맞춤형방사선치료를 위해 임상에서 활용하고 있는 입체적세기조절회전방사선치료의 정도관리를 수행하고자 기존의 세기조절방사선치료에서 수행하는 정도관리 프로그램을 본 원의 실정에 맞게 치료계획단계 정도관리(Treatment planning QA), 치료전 전달단계 정도관리(Pretreatment delivery QA), 치료단계 정도관리(Treatment QA)인 세 가지 단계로 나누어 설정하였다. 각 정도관리 단계에서는 정도관리 프로그램에 따라 점검할 항목과 측정하여 평가할 항목을 설정하여 문서화를 위해 서식화 하였다. 본 원에서는 서식화한 정도관리 프로그램에 따라 실제 치료환자에 적용하였으며 본원의 치료전 전달 정도관리의 임상 허용기준을 위해 국소적 신뢰수준(confidence limit, CL)을 평가하였다. 그 결과 고선량 영역 점선량 측정, 저선량영역 점선량 측정의 CL는 모두 기존의 IMRT 수준과 유사한 결과를 얻었으며 이를 토대로 본원의 임상허용 기준은 고선량영역은 3%, 저선량 영역은 5%로 설정하였다. 입체적세기조절회전방사선치료의 특성상 Intensity map 평가는 360도 전 방향에서 Intensity map을 측정할 수 있는 ArcCheck 기기를 사용 하여 감마 지표(Gamma Index) 평가를 하였으며 그 결과는 IMRT의 개별적 intensity map 평가와 유사한 결과를 얻었으며 본원의 CL은 93%로 설정하였다. 등선량분포 평가는 2D detector array인 Mapcheck을 사용하였으며 95% 이상의 일치도를 보여 본원의 CL은 95%로 설정하였다. 방사선치료 정도관리에서 임의의 불확도와 계통 오차를 줄이려면 실제 환자 적용에 앞서 다 기관이 참여하는 팬톰을 이용한 국소적 CL 평가를 권장하고 있다. 국내 여건상 다 기관이 참여하는 연구가 여의치 않다면 본 연구와 같이 개별 기관에서 자체적으로 허용검사가 끝난 후에 실제 임상에서는 환자 치료 부위별로 세분화 하여 국소적 CL을 평가하는 방법이 유용할 것으로 사료된다.

간암환자에서 Electronic Portal Imaging Device(EPID)를 이용한 자세 오차 및 종양 이동 거리의 객관적 측정 (Measurements of Setup Error and Physiological Movement of Liver by Using Electronic Portal Imaging Device in Patients with Hepatocellular Carcinoma)

  • 금기창;이상욱;신현수;김귀언;성진실;이창걸;추성실;장세경;서창옥
    • Radiation Oncology Journal
    • /
    • 제18권2호
    • /
    • pp.107-113
    • /
    • 2000
  • 목적 : 간암의 3차원 입체조형치료계획시 electronic portal imaging device (EPID)를 이용한 검증영상으로 경계여유 결정에 필요한 객관적 기초자료를 얻으므로써 방사선치료의 정확성을 높이고 본 기기를 이용하여 방사선치료의 정도관리 측면에서의 유용성을 알아보고자 하였다. 대상 및 방법: 10명의 간암 환자에서 EPID를 이용하여 1회 방사선 치료 중 약 4극회의 검증영상을 획득하였고 총 10회 분할 치료기간 동안 반복하여 시행하였다. 방사선치료 자세 고정시 발생할 수 있는 각 개인의 자세 오차를 구하여 치료간 발생하는 환자의 위치 이동을 분석하였고, 호흡으로 인한 간의 상하 움직임의 정도를 측정하여 계획용표적체적(Planning Target Volume, PTV)의 결정시 필요한 적정 경계 여유를 구하였다. 결과 : 검증영상 분석 결과 간암의 치료시 자세이동에 의한 자세 오차는 x축으로 3.0 mm, 표준편차는 1.70 mm 였고 y축으로 3.7 mm, 표준편차 1.88 mm 였다. 따라서 각 축을 중심으로 5 mm 이내였다. 또한 호흡에 의한 간의 상하 운동 범위는 평균 8.63 mm이었고 표준편차는 1.48 mm 였다. 따라서 계획용표적체적 결정시 종양에 적어도 15 mm의 경계여유가 더 필요하다 결론 : EPID는 3차원 입체조형치료계획시 종양의 경계여유 결정에 매우 유용하며 나아가서 방사선치료의 정도관리에도 크게 기여할 것이다

  • PDF

원격 품질 보증 시스템을 사용한 세기변조 방사선치료의 예비 모니터링 결과 (A Pilot Study for the Remote Monitoring of IMRT Using a Head and Neck Phantom)

  • 한영이;신은혁;임천일;강세권;박성호;라정은;서태석;윤명근;이세병;주상규;안용찬
    • Radiation Oncology Journal
    • /
    • 제25권4호
    • /
    • pp.249-260
    • /
    • 2007
  • 목적: 국내에서 시행되고 있는 세기변조 방사선 치료(IMRT)의 품질 향상을 위하여, 우편으로 시행하는 원격 품질보증 시스템을 개발하고, 이 시스템의 정확성 확인에 이어서, 국내 의료기관에서 타당성을 검증한다. 대상 및 방법: 원격 품질 보증 시스템은 두경부 팬톰과 IMRT의 치료계획 지침을 포함하는 사용자 설명서로 구성되어 있다. 두경부 용 팬톰은 내부에 CT영상에서 분별이 가능한 모사 치료표적(target)과 3개의 위험장기(좌, 우 이하선, 척추)를 포함하고 있으며, 각 모사 장기의 중심에서 열형광 소자(TLD)를 삽입하여 흡수 선량을 측정하도록 구성되어있다. 또한 2차원상의 선량분포를 확인 가능하도록 Gafchromic@EBT 필름을 2개의 평면에 삽입하도록 고안하였다. 고안된 팬톰과 사용자 설명서를 국내의 4개 기관에 보내어, 팬톰에 대한 IMRT치료계획을 수행하고 치료를 시행하였다. 치료계획 시 예측된 치료표적과 위험장기 내의 각 TLD에서 예측되는 절대 선량과 TLD의 측정값을 비교하였고, 횡단면에서 면의 중심을 지나는 2개의 직교하는 수평선과 수직선상에서 예측되는 상대적인 선량분포 값과 실제 측정값을 비교하였다. 결 과: 치료 표적에서의 선량측정 값은 모두 치료계획시의 예측값과 3% 오차 안에서 일치하였으나(평균오차, 1.5%), 좌우 이하선에 해당하는 위험장기에서는 최소 3.3%최대 19.8%의 차이를 보였다. 척추에 해당하는 위험장기에서의 오차의 범위는 $0.7{\sim}1.4%$였다. 2차원 선량분포는 3개 기관에 대한 자료를 분석하였는데, 직선상에서 예측 값과 5%이상의 차이를 보이는 비율이 수평선에서는 $7{\sim}27%$, 수직선상에서는 $7{\sim}14%$였다. 결 론: 본 연구에서 개발한 IMRT치료의 원격 품질보증 시스템과 사용자 설명서는 국내 시행이 가능한 상태로 판단된다. 그러나, 시행 시에 치료표적에서의 오차는 크지 않을 것으로 예상이 되지만, 위험장기에서의 오차는 클 것으로 예상되며, 이에 대한 방안이 마련돼야 할 것이며, 또한 임상의 중요성과 연관해 의미 있는 2차원 선량분포의 기준 마련이 요구된다.

AN EXPERIMENTAL STUDY OF NEWLY DESIGNED IMPLANT WITH RBM SURFACE IN THE RABBIT TIBIA : RESONANCE FREQUENCY ANALYSIS AND REMOVAL TORQUE STUDY

  • Won Mi-Kyoung;Park Chan-Jin;Chang Kyoung-Soo;Kim Chang-Whe;Kim Yung-Soo;Isa Zakiahbt Mohd;Ariffin Yusnidar Tajul
    • 대한치과보철학회지
    • /
    • 제41권6호
    • /
    • pp.720-731
    • /
    • 2003
  • Statement of problem. The importance of fixture design and surface treatment. Purpose. The clinical success of dental in plants is affected by many factors such like as degree of osseointegration, the effective load dispersion for the prostheses, and a lot of attempts have been made to overcome the difficulties. In this study, efforts were made to find the possibility of clinical acceptance of the dental implants of newly designed surface and resorbable blast media surcace. Materials and methods. In this study, two groups of custom-made, screw-shaped implants were prepared. The first with the consisting of Branemark clone design and the other with the new design. These implants were divided into four groups according to the kinds of surface treatment. Four implants($AVANA^{(R)}$, Osstem, Busan, Korea)of each group were installed in twenty rabbits. Group A was consisted of Branemark done implant left as machined, Group B with Branemark clone implants with RBM(Resorbable blast media) surface, Group C with newly designed implants left as machined and Group D with newly designed implants with RBM surface. One of the twenty rabbits died from inflammation and the observation was made for six weeks. Specimens from four groups were observed using scanning electron microscopy with 40, 100, 1000 magnification power and microsurface structures were measured by white-light scanning interferometry for three dimensional surface roughness measurements(Accura $2000^{(R)}$, Intek-Plus, Korea.). Removal torque was measured in 17 rabbits using digital torque gauge(MGT 12R, Mark-10 corp., NY, U.S.A.) immediately after the sacrifice and two rabbits were used for the histologic preparation(EXAKT $310^{(R)}$, Heraeus Kulzer, wehrheim, Germany) of specimens and observed under light microscope. Resonance frequency measurement($Osstell^{(R)}$) was taken with the 19 rabbits at the beginning of the implant fixation and immediately after the sacrifice. Results. Following results were taken from the experiment. 1. The surface of the RBM implants as seen with SEM had rough and irregular pattern with reticular formation compared to that of fumed specimens showing different surface topographies. 2. The newly designed implant with RBM surface had high removal torque value among four groups with no statistical significance. The average removal torque was $49.95{\pm}6.70Ncm$ in Group A, $51.15{\pm}4.40Ncm$ in Group B, $50.78{\pm}9.37Ncm$ in Group C, $51.09{\pm}4.69Ncm$ in Group D. 3. The RFA values were $70.8{\pm}4.3Hz$ in Group A, $71.8{\pm}3.1Hz$ in Group B, $70.9{\pm}2.5Hz$, $72.7{\pm}2.5Hz$ in Group D. Higher values were noted in the groups which had surface treatment compared to the untreated groups with no statistical significance. 4. The results from the histomorphometric evaluation showed a mean percentage of bone-to-implant contact of $45{\pm}0.5%$ in Group A, $55{\pm}3%$ in Group B, $49.5{\pm}0.5%$ in Group C, and $55{\pm}3%$ in Group D. Quite amount of newly formed bone were observed at the surface RBM-treated implants in bone marrow space.

터널 현장 계측결과를 통한 강관보강 그라우팅의 거동 메커니즘 (Mechanism of steel pipe reinforcement grouting based on tunnel field measurement results)

  • 신현강;정혁상;이용주;김낙영;고성일
    • 한국터널지하공간학회 논문집
    • /
    • 제23권3호
    • /
    • pp.133-149
    • /
    • 2021
  • 본 논문은 터널 굴착 시 굴착면의 안정성 확보를 위해 매우 활발히 적용되고 있는 강관보강 그라우팅의 거동 메커니즘을 실제 현장의 계측결과를 이용하여 연구한 결과를 수록하였다. 계측방법은 12 m의 강관에 형상변위계와 변형률계를 부착하여 실제 터널면에 보강을 시행한 다음 강관의 변형과 응력의 계측값을 분석하여 거동 특성을 파악하였으며, 6 m마다 강관이 중첩되는 것을 고려하여 7 m 굴착 시까지의 계측결과를 활용하였다. 또한, 허용응력이 다른 강관(SGT275와 SGT550)을 적용하여 강도차이에 따른 강관 보강재의 거동 특성도 확인하였다. 굴착면에 강관을 설치하고 최초 1 m 굴착 후 다음 굴착이 진행되기 전까지 7시간 동안의 강관 거동을 분석한 결과 굴착 이완하중에 따른 아칭효과로 응력이 재분배되는 거동 특성을 확인할 수 있었다. 1 m씩 굴착됨에 따라 3차원적인 이완하중의 응력분배로 인해 굴착된 구간은 4~6 m 굴착 시 가장 큰 변형을 나타내었다. 이러한 계측을 통해 굴착 전방지반의 설치된 강관에도 변형과 응력이 발생되는 것을 확인할 수 있었다. 또한, SGT275강관(항복강도 275 MPa)과 SGT550강관(항복강도 550 MPa)의 거동을 비교한 결과 변형량의 차이는 최대 18배, 응력은 최대 12배 정도 차이가 발생되어 강도가 큰 강관일수록 이완하중에 대응이 유리한 것으로 나타났다. 본 논문에서는 실제 터널 굴착에 따른 강관의 계측결과를 이용하여 이완하중의 아칭효과에 대응하는 강관 보강 그라우팅의 거동 메커니즘을 확인할 수 있었고, 그 결과를 본 논문에 수록하였다.