Usefulness of volumetric BMD measurement by using low dose CT image acquired on L-spine Bone SPECT/CT (L-spine Bone SPECT/CT에서 획득된 저선량 CT 영상을 이용한 용적 골밀도 결과의 유용성)

  • Hyunsoo Ko;Soonki Park;Eunhye Kim;Jongsook Choi;Wooyoung Jung;Dongyun Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.99-109
    • /
    • 2023
  • Purpose: CT scan makes up for the weak point of the nuclear medicine image having a low resolution and also were used for attenuation correction on image reconstruction. Recently, many studies try to make use of CT images additionally, one of them is to measure the bone mineral density(BMD) using Quantitative CT(QCT) software. BMD exams are performed to scan lumbar and femur with DXA(Dual-Energy X-Ray Absorptiometry) in order to diagnose bone disease such as osteopenia, osteoporosis. The purpose of this study is to identify the usefulness of QCT_BMD analyzed with low dose CT images on L-spine Bone SPECT/CT comparing with DXA_BMD. Materials and Methods: Fifty five women over 50 years old (mean 66.4 ± 9.1) who took the both examinations(L-spine Bone SPECT/CT with SIEMENS Intevo 16 and DXA scan with GE Lunar prodigy advance) within 90 days from April 2017 to July 2022, BMD, T-score and disease classification were analyzed. Three-dimensional BMD was analyzed with low dose CT images acquired on L-spine Bone SPECT/CT scan on Mindways QCT PROTM software and two-dimensional BMD was analyzed on DXA scan. Basically, Lumbar 1-4 were analyzed and the patients who has lesion or spine implants on L-spine were excluded for this study. Pearson's correlation analysis was performed in BMD and T-score, chi-square test was performed in disease classification between QCT and DXA. Results: On 55 patients, the minimum of QCT_BMD was 18.10, maximum was 166.50, average was 82.71 ± 31.5 mg/cm3. And the minimum of DXA-BMD was 0.540, maximum was 1.302, average was 0.902 ± 0.201 g/cm2, respectively. The result shows a strong statistical correlation between QCT_BMD and DXA_BMD(p<0.001, r=0.76). The minimum of QCT_T-score was -5.7, maximum was -0.1, average was -3.2 ± 1.3 and the minimum of DXA_T-score was -5.0, maximum was 1.7, average was -2.0 ± 1.3, respectively. The result shows a statistical correlation between QCT T-score and DXA T-score (p<0.001, r=0.66). On the disease classification, normal was 5, osteopenia was 25, osteoporosis was 25 in QCT and normal was 10, osteopenia was 25, osteoporosis was 20 in DXA. There was under-estimation of bone decrease relatively on DXA than QCT, but there was no significant differences statistically by chi-square test between QCT and DXA. Conclusion: Through this study, we could identify that the QCT measurement with low dose CT images QCT from L-Spine Bone SPECT/CT was reliable because of a strong statistical correlation between QCT_BMD and DXA_BMD. Bone SPECT/CT scan can provide three-dimensional information also BMD measurement with CT images. In the future, rather than various exams such as CT, BMD, Bone scan are performed, it will be possible to provide multipurpose information via only SPECT/CT scan. In addition, it will be very helpful clinically in the sense that we can provide a diagnosis of potential osteoporosis, especially in middle-aged patients.

Volume measurement of limb edema using three dimensional registration method of depth images based on plane detection (깊이 영상의 평면 검출 기반 3차원 정합 기법을 이용한 상지 부종의 부피 측정 기술)

  • Lee, Wonhee;Kim, Kwang Gi;Chung, Seung Hyun
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.7
    • /
    • pp.818-828
    • /
    • 2014
  • After emerging of Microsoft Kinect, the interest in three-dimensional (3D) depth image was significantly increased. Depth image data of an object can be converted to 3D coordinates by simple arithmetic calculation and then can be reconstructed as a 3D model on computer. However, because the surface coordinates can be acquired only from the front area facing Kinect, total solid which has a closed surface cannot be reconstructed. In this paper, 3D registration method for multiple Kinects was suggested, in which surface information from each Kinect was simultaneously collected and registered in real time to build 3D total solid. To unify relative coordinate system used by each Kinect, 3D perspective transform was adopted. Also, to detect control points which are necessary to generate transformation matrix, 3D randomized Hough transform was used. Once transform matrices were generated, real time 3D reconstruction of various objects was possible. To verify the usefulness of suggested method, human arms were 3D reconstructed and the volumes of them were measured by using four Kinects. This volume measuring system was developed to monitor the level of lymphedema of patients after cancer treatment and the measurement difference with medical CT was lower than 5%, expected CT reconstruction error.

Measurement of Prostate Phantom Volume Using Three-Dimensional Medical Imaging Modalities (3차원 의료영상진단기기를 이용한 가상 전립선 용적 측정)

  • Seoung, Youl-Hun;Joo, Yong-Hyun;Choe, Bo-Young
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.4
    • /
    • pp.285-291
    • /
    • 2010
  • Recently, advance on various modalities of diagnosing, prostate volume estimation became possible not only by the existing two-dimension medical images data but also by the three-dimensional medical images data. In this study, magnetic resonance image (MRI), computer tomography (CT) and ultrasound (US) were employed to evaluate prostate phantom volume measurements for estimation, comparison and analysis. For the prostate phantoms aimed at estimating the volume, total of 17 models were developed by using devils-tongue jelly and changing each of the 5ml of capacity from 20ml to 100ml. For the volume estimation through 2D US, the calculation of the diameter with C9-5Mhz transducer was conducted by ellipsoid formula. For the volume estimation through 3D US, the Qlab software (Philips Medical) was used to calculate the volume data estimated by 3D9-3Mhz transducer. Moreover, the images by 16 channels CT and 1.5 Tesla MRI were added by the method of continuous cross-section addition and each of imaginary prostate model's volume was yielded. In the statistical analysis for comparing the availability of volume estimation, the correlation coefficient (r) was more than 0.9 for all indicating that there were highly correlated, and there were not statistically significant difference between each of the correlation coefficient (p=0.001). Therefore, the estimation of prostate phantom volume using three-dimensional modalities of diagnosing was quite closed to the actual estimation.

The three-dimensional microstructure of trabecular bone: Analysis of site-specific variation in the human jaw bone

  • Kim, Jo-Eun;Shin, Jae-Myung;Oh, Sung-Ook;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul;Huh, Kyung-Hoe
    • Imaging Science in Dentistry
    • /
    • v.43 no.4
    • /
    • pp.227-233
    • /
    • 2013
  • Purpose: This study was performed to analyze human maxillary and mandibular trabecular bone using the data acquired from micro-computed tomography (micro-CT), and to characterize the site-specific microstructures of trabeculae. Materials and Methods: Sixty-nine cylindrical bone specimens were prepared from the mandible and maxilla. They were divided into 5 groups by region: the anterior maxilla, posterior maxilla, anterior mandible, posterior mandible, and mandibular condyle. After the specimens were scanned using a micro-CT system, three-dimensional microstructural parameters such as the percent bone volume, bone specific surface, trabecular thickness, trabecular separation, trabecular number, structure model index, and degrees of anisotropy were analyzed. Results: Among the regions other than the condylar area, the anterior mandibular region showed the highest trabecular thickness and the lowest value for the bone specific surface. On the other hand, the posterior maxilla region showed the lowest trabecular thickness and the highest value for the bone specific surface. The degree of anisotropy was lowest at the anterior mandible. The condyle showed thinner trabeculae with a more anisotropic arrangement than the other mandibular regions. Conclusion: There were microstructural differences between the regions of the maxilla and mandible. These results suggested that different mechanisms of external force might exist at each site.

DEVELOPMENT OF THREE DIMENSIONAL MEASURING PROGRAM WITH FRONTAL AND LATERAL CEPHALOMETRIC RADIOGRAPHS -PART 2. 3-D VISUALIZATION AND MEASURMENT PROGRAM FOR MAXILLOFACIAL STRUCTURE- (정모 및 측모 두부 방사선 규격사진을 이용한 3차원 계측 프로그램의 개발 -2. 악안면 구조에 대한 3차원적 시각화 및 측정프로그램 개발-)

  • Lee, Sang-Han;Mori, Yoshihide;Minami, Katsuhiro;Lee, Geun-Ho;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.4
    • /
    • pp.321-329
    • /
    • 2001
  • To establish systematic diagnosis and treatment planning of dentofacial deformity patient including facial asymmetry or hemifacial microsomia patient, comprehensive analysis of three dimensional structure of the craniofacial skeleton is needed. Even though three dimensional CT has been developed, landmark identification of the CT is still questionable. In recent, a method for correcting cephalic malpositioning that enables accurate superimposition of the landmarks in different stages without using any additional equipment was developed. It became possible to compare the three-dimensional positional change of the maxillomandible without invasive procedure. Based on the principle of the method, a new program was developed for the purpose of diagnosis and treatment planning of dentofacial deformity patient via three dimensional visualization and structural analysis. This program enables us to perform following menu. First, visualization of three dimensional structure of the craniofacial skeleton with wire frame model which was made from the landmarks observed on both lateral and frontal cephalogram. Second, establishment of midsagittal plane of the face three dimensionally, with the concept of "the plane of the best-fit". Third, examination of the degree of deviation and direction of deformity of structure to the reference plane for the purpose of establishing surgical planning. Fourth, simulation of expected postoperative result by various image operation such as mirroring, overlapping.

  • PDF

Development and Performance Evaluation of an Ultra-Compact CT with Auto Calibration of Detector Center Axis (검출기 중심축을 자동 보정하는 초소형 CT 개발 및 성능평가)

  • Byeong-Woo Kwak;Keun-Ho Rew
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.651-662
    • /
    • 2023
  • In this study, we designed and fabricated an ultra-compact CT that automatically calibrates the detector's center axis and verified its performance. The three-dimensional reconstruction performance was evaluated using 3D CAD data and X-ray data acquired by manually calibrating the center axis of the CT detector. The results showed that tilting the center axis by more than 0.25° causes circle break phenomenon, which rapidly degrades the quality of the 3D reconstructed image. By applying the automatic calibration device of a detector center axis, the 3D reconstruction performance was enhanced by calibrating the detector center axis to match the specimen rotation axis.

The medical 3-dimensional image exchange via health level 7 fast healthcare interoperability resource (HL7 FHIR) (Health level 7 fast healthcare interoperability resource (HL7 FHIR)를 통한 3차원 의료 영상의 교환)

  • Lee, Jung Hwan;Choi, Byung Kwan;Han, In Ho
    • Journal of Digital Convergence
    • /
    • v.18 no.6
    • /
    • pp.373-378
    • /
    • 2020
  • For improving interoperability of medical information, health level 7 has initiated the development of a next-generation framework for the exchange of medical information called the Fast health interoperability resources (FHIR). However, there was no attempt to exchange the medical three-dimensional (3D) image with clinical data via FHIR. Thus, we designed a new method. The 3D image to be made from computed tomography was converted to the javascript object notation (JSON) file format, and clinical data was added. We made a test FHIR server, and the client used the postman. The JSON file was attached to the body, and was then transmitted. The transmitted 3D image could be seen through a web browser, and attached clinical data was identified in the source code. This is the first attempt to exchange the medical 3D image. Additional researches will be needed to develop applications or FHIR resources that apply this method.

Effects of the cone-beam computed tomography protocol on the accuracy and image quality of root surface area measurements: An in vitro study

  • Chanikarn Intarasuksanti;Sangsom Prapayasatok;Natnicha Kampan;Supassara Sirabanchongkran;Pasuk Mahakkanukrauh;Thanapat Sastraruji;Pathawee Khongkhunthian;Kachaphol Kuharattanachai;Kanich Tripuwabhrut
    • Imaging Science in Dentistry
    • /
    • v.53 no.4
    • /
    • pp.325-333
    • /
    • 2023
  • Purpose: The objective of this study was to evaluate and compare the accuracy and image quality of root surface area (RSA) measurements obtained with various cone-beam computed tomography (CBCT) protocols, relative to the gold standard of micro-computed tomography (CT), in an in vitro setting. Materials and Methods: Four dry human skulls were scanned using 8 different protocols, with voxel sizes of 0.15 mm, 0.3 mm, and 0.4 mm. Three-dimensional models of the selected teeth were constructed using CBCT and microCT protocols, and the RSA was automatically measured by the image-processing software. The absolute difference in the percentage of the RSA(%ΔRSA) was calculated and compared across the 8 CBCT protocols using repeatedmeasures analysis of variance. Finally, image quality scores of the RSA measurements were computed and reported in terms of percent distribution. Results: No significant differences were observed in the %ΔRSA across the 8 protocols (P>0.05). The deviation in %ΔRSA ranged from 1.51% to 4.30%, with an increase corresponding to voxel size. As the voxel size increased, the image quality deteriorated. This decline in quality was particularly noticeable at the apical level of the root, where the distribution of poorer scores was most concentrated. Conclusion: Relative to CBCT protocols with voxel sizes of 0.15mm and 0.3mm, the protocols with a voxel size of 0.4 mm demonstrated inferior image quality at the apical levels. In spite of this, no significant discrepancies were observed in RSA measurements across the different CBCT protocols.

Wall Thickness Measurement of Respiratory Airway in CT Images: Signal Processing Aspects

  • Park, Sang-Joon;Kim, Jong-Hyo;Kim, Kwang-Gi;Lee, Sang-Ho
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.279-280
    • /
    • 2007
  • Airway wall thickness is an important bio-marker for evaluation of pulmonary diseases such as stenosis, bronchiectasis. Nevertheless, an image-based analysis of the airway tree can provide precise and valuable airway size information, quantitative measurement of airway wall thickness in CT images involves various sources of error and uncertainty. So we have developed an accurate airway wall measurement technique for small airways with three-dimensional (3-D) approach. To illustrate performance of these techniques, we used airway phantom that consisted of 4 acryl tubes with various inner and outer diameters. Results show that evaluation of interpolation and deconvolution methods of airways in 3-D CT images, and significant improvement over the full-width-half-maximum method for measurement of not only location of the luminal and outer edge of the airway wall but airway wall thickness.

  • PDF

Radiologic study of the healing process of the extracted socket of beagle dogs using cone beam CT (Cone beam CT를 이용한 비글견 발치창 치유과정에 대한 방사선학적 연구)

  • Choi, Dong-Hoon;Lee, Wan;Kim, De-Sok;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.39 no.1
    • /
    • pp.19-25
    • /
    • 2009
  • Purpose: To longitudinally observe the healing process of extracted socket and the alterations of the residual ridge in healthy adult dogs using cone beam CT (CBCT). Materials and Methods: The mandibular premolars of two beagle dogs were removed and the extraction sites were covered with the gingival tissue. CBCTs (3D X-ray CT scanner, Alphard vega, Asahi Co.) were taken at baseline and at 1 week interval for 12 weeks. Radiographic density of extracted wounds was measured on normalized images with a custom-made image analysis program. The amount of alveolar crestal resorption after the teeth extraction was measured with a reformatted three-dimensional image using CBCT. Bony healing pattern of extracted wound of each group was also longitudinally observed and analyzed. Results: Dimensional changes occurred during the first 6 weeks following the extraction of dogs' mandibular premolars. The reduction of the height of residual ridge was more pronounced at the buccal than at the lingual aspect of the extraction socket. Radiographic density of extracted wounds increased by week 4, but the change in density stabilized after week 6. New bone formation was observed at the floor and the peripheral side of extracted socket from week 1. The entrance of extracted socket was sealed by a hard-tissue bridge at week 5. Conclusion: The healing process of extracted wound involved a series of events including new bone formation and residual ridge resorption.

  • PDF