The Study of Pain-Increased Factors on Cervical and Shoulder Pain by 3 Dimensional Moire Scanner (3차원 체형 측정기를 통한 경.견부 통증요인 분석)

  • Yang, Hoe-Song;Heo, Ja-Eun;Kim, Bo-Young;Seo, Dong-Yong;An, Chang-Heon;Yang, Hun-Kyung;Jeong, Chan-Ju;Lee, Hyoung-Soo
    • Journal of Korean Physical Therapy Science
    • /
    • v.12 no.3
    • /
    • pp.27-34
    • /
    • 2005
  • The purpose of this study is to find out factors(shoulder level, acromion-occipital length, spine alignment, spine-scapula inferior angle length) of pain of neck & shoulder by 3 Dimensional Moire Scanner. 50 female student s aged 20 to 25 years old participated who lived in Sun-cheon si Jeonnam. They were examined with three measurement methods(Visual Analogue Scale : VAS, Algometer, 3 Dimensional Moire Scanner(IBS-2000). According to the results of multiple regression analysis. 1) There was a significant difference with shoulder level and spine-scapula inferior angle based on VAS. 2) There was a significant difference with shoulder level based of Algometer measurement value in Rhomboid muscles.

  • PDF

Comparison of the Internal Fitness of Prostheses Fabricated with Non-Contact Extra-Oral Scanner and Intra-Oral Video Scanner (비접촉식 구강외 스캐너와 비디오방식 구강내 스캐너를 이용하여 제작된 보철물의 내면정확도 비교)

  • Park, Jin-Young;Kim, Ji-Hwan;Jeong, Il-Do;Lee, Gwang-Young;Kim, Won-Soo
    • Journal of Technologic Dentistry
    • /
    • v.41 no.4
    • /
    • pp.263-269
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the internal fitness of prostheses fabricated with non-contact extra-oral scanner and those fabricated with intra-oral video scanner, with a comparative accuracy analyses of their precision and trueness. Methods: A polymethyl methacrylate (PMMA) model was fabricated by replicating a master model. The prostheses in the first group were fabricated based on the PMMA model with an intra-oral video scanner (IVS group). Following the fabrication of work models with Type IV Stone that were based on the PMMA model, the prostheses in the second group were fabricated with a non-contact extra-oral scanner (ENB group). The precision and trueness of the prostheses were calculated from comparisons of the three-dimensional images of the internal surfaces of the prostheses and those of the master model. Kruskal-Wallis tests were used to determine the statistical significance, with the level of type 1 error set at 0.05. Results: Trueness (P < 0.009) and precision (P < 0.001) did not differ significantly between the ENB and IVS groups. The IVS group exhibited lower trueness values and larger precision values than the ENB group. Conclusion: Although no significant differences were found in the internal fitness of the prostheses that were fabricated by the two different scanners, the intraoral video scanner-fabricated prostheses had better trueness, whereas the non-contact extra-oral scanner-fabricated prostheses had better precision.

Classification of Elderly Women's Foot Type (노년 여성의 발 유형분류)

  • Kim, Nam-Soon;Do, Wol-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.3
    • /
    • pp.305-320
    • /
    • 2014
  • This study identifies the foot shapes of elderly women by classifying foot type according to the 3D shape of the foot and 2D sole type analyzing individual characteristics. The subjects were 295 elderly women over 60 years of age who live in Gwangju. A foot scanner (K&I Technology $Nexcan^{(R)}$) was used to obtain three-dimensional shapes of feet and a flat bad scanner (HP Scanjet G2410) was used to obtain the two-dimensional shapes of soles. The anthropometric measuring items consisted of 59 items estimated on the right foot of each subject. Data were analyzed by various statistical methods such as factor analysis, ANOVA and cluster analysis using the SPSS 19.0 statistical program. To classify the side type of elderly women's feet, three-dimensional measurement data were analyzed for the 27 measurement items using factor analysis and 6 factors were extracted (inside height and side gradient, ankle thickness, toe height and midfoot size, lateral malleolus height, instep, and heel height and gradient). A cluster analysis resulted in three types: 36.5% belonged to Type 1 (high forefoot and high midfoot), 31.1% belonged to Type 2 (high forefoot and low midfoot), and 32.4% belonged to Type 3 (low forefoot and high midfoot). The distribution was relatively even. For the sole, 8 factors were extracted (ball width and medial foot protrusion, lateral foot protrusion, forefoot and hindfoot length ratio, ball gradient, heel size, toe breadth, lateral ball length, and foot length) and a cluster analysis resulted in three Types (Type H, Type D, and Type A). The largest proportion (42.7%) belonged to Type H, which is the same as the elderly men's case.

The study on the dimensional stability of digitized dental stone replicas according to difference color of gypsum materials (치과용 모형재 색상에 따른 디지털 모형의 체적 안정성 연구)

  • Choi, Seog-Soon;Kim, Ki-Baek;Lee, Gyeong-Tak;Jeon, Jin-Hun;Kim, Jae-Hong
    • Journal of Technologic Dentistry
    • /
    • v.34 no.4
    • /
    • pp.369-377
    • /
    • 2012
  • Purpose: The aim of study was to compare the dimensional stability of digitized dental stone replica using different color of gypsum materials using a white light scanner with three-dimensional software. Methods: A master model(500B-1, Nissin dental product, Japan) with the prepared lower full arch tooth was used. Several type IV stones(white, yellow, green) were used for 30 stone casts(10 casts each) duplicated a master model of mandible. The master model and the replicas were digitized with the non-contacting white light scanner to create 3-dimensional digital models. The linear distance between the reference points were measured and analyzed on the Delcam Copycad$^{(R)}$(Delcam plc, UK) 3D graphic software. One-way analysis of variance(ANOVA) combined with a Tukey multiple-range test were used to analysis the data(${\alpha}$=0.05). Results: There were considerable differences in mean values between gypsum materials within each color(white, yellow, green), and this difference was statistically significant, p=0.001. Conclusion: Digitization of dental materials on optical scanner was affected by color. Three different color of gypsum materials showed clinically acceptable accuracies of full arch digital model produced by them. Besides, these results will have to be confirmed in further clinical studies.

Accuracy of Bolton analysis measured in laser scanned digital models compared with plaster models (gold standard) and cone-beam computer tomography images

  • Kim, Jooseong;Lagravere, Manuel O.
    • The korean journal of orthodontics
    • /
    • v.46 no.1
    • /
    • pp.13-19
    • /
    • 2016
  • Objective: The aim of this study was to compare the accuracy of Bolton analysis obtained from digital models scanned with the Ortho Insight three-dimensional (3D) laser scanner system to those obtained from cone-beam computed tomography (CBCT) images and traditional plaster models. Methods: CBCT scans and plaster models were obtained from 50 patients. Plaster models were scanned using the Ortho Insight 3D laser scanner; Bolton ratios were calculated with its software. CBCT scans were imported and analyzed using AVIZO software. Plaster models were measured with a digital caliper. Data were analyzed with descriptive statistics and the intraclass correlation coefficient (ICC). Results: Anterior and overall Bolton ratios obtained by the three different modalities exhibited excellent agreement (> 0.970). The mean differences between the scanned digital models and physical models and between the CBCT images and scanned digital models for overall Bolton ratios were $0.41{\pm}0.305%$ and $0.45{\pm}0.456%$, respectively; for anterior Bolton ratios, $0.59{\pm}0.520%$ and $1.01{\pm}0.780%$, respectively. ICC results showed that intraexaminer error reliability was generally excellent (> 0.858 for all three diagnostic modalities), with < 1.45% discrepancy in the Bolton analysis. Conclusions: Laser scanned digital models are highly accurate compared to physical models and CBCT scans for assessing the spatial relationships of dental arches for orthodontic diagnosis.

The Classification of Elderly Men's Feet - With the Three-dimensional Body Scanner Data of Size Korea - (노년 남성의 발 유형 분류 -Size Korea의 3차원 측정 데이터를 이용하여-)

  • Seok, Hye-Jung;Park, Ji-Eun
    • Journal of the Korean Society of Costume
    • /
    • v.57 no.10
    • /
    • pp.50-59
    • /
    • 2007
  • This study has been conducted to classify elderly men's feet with the three-dimensional body scanner data of Size Korea. It was intended to assist the manufacturing of the shoes that can appropriately perform the functions of feet, by providing the specific information about the shapes of elderly men's feet that are altered as a result of aging and shoe-wearing for a long time. The findings are as follows. 1. The investigations into the average and standard deviation of the measurements and index values for the elderly men's feet showed a large personal difference in the items of length and circumference. 2. The factors constituting the elderly men's feet were observed to be the size of foot width(Factor 1), the central angle of feet and the extension of toes(Factor 2), the size of ankle(Factor 3), the positions of lateral malleolus and pternion(Factor 4), and the position and size of medial malleolus(Factor 5). 3. The cluster analysis for the classification of elderly men's feet produced three types of them.

Case study - Design a cell phone cover by using reverse engineering (사례 연구 - 3차원 역설계를 이용한 휴대폰 보호 커버 설계)

  • Kim, Daejoon;Sung, Jinho;Chung, Sungdae;Chung, Yunchan
    • Design & Manufacturing
    • /
    • v.6 no.1
    • /
    • pp.29-33
    • /
    • 2012
  • A 3D scanner scans and captures the shape of a real-world object. The captured shape can be used to construct three-dimensional model for CAD/CAM applications. In this study we have tried to design a cell phone cover by using the 3D scanner and reverse engineering. A 3D scanner is used to capture the shape of a cell phone. The 3D scanner generates a point cloud as the shape information. A three-dimensional CAD model for the cell phone is constructed from the point cloud. A cell phone cover is designed based on the CAD model of the cell phone. To check the integrity of this design process a prototype of the cover is made and assembled with the cell phone.

  • PDF

Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations

  • Bi, Chuang;Wang, Xingyu;Tian, Fangfang;Qu, Zhe;Zhao, Jiaming
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.4
    • /
    • pp.236-249
    • /
    • 2022
  • PURPOSE. The present study compared the accuracy between digital and conventional implant impressions. MATERIALS AND METHODS. The experimental models were divided into six groups depending on the implant location and the scanning span. Digital impressions were captured using the intraoral optical scanner TRIOS (3Shape, Copenhagen, Denmark). Conventional impressions were taken with the monophase impression material based on addition-cured silicones, Honigum-Mono (DMG, Hamburg, Germany). A high-precision laboratory scanner D900 (3Shape, Copenhagen, Denmark) was used to obtain digital data of resin models and stone casts. Surface tessellation language (STL) datasets from scanner were imported into the analysis software Geomagic Qualify 14 (3D Systems, Rock Hill, SC, USA), and scan body deviations were determined through two-dimensional and three-dimensional analyses. Each scan body was measured five times. The Sidak t test was used to analyze the experimental data. RESULTS. Implant position and scanning distance affected the impression accuracy. For a unilateral arch implant and the mandible models with two implants, no significant difference was observed in the accuracy between the digital and conventional implant impressions on scan bodies; however, the corresponding differences for trans-arch implants and mandible with six implants were extremely significant (P<.001). CONCLUSION. For short-span scanning, the accuracy of digital and conventional implant impressions did not differ significantly. For long-span scanning, the precision of digital impressions was significantly inferior to that of the traditional impressions.

A Study on the Scanner Calibration Method Using Look-up Table (룩업테이블을 이용한 스캐너 캘리브레이션에 관한 연구)

  • 신춘범;강상훈
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.20 no.1
    • /
    • pp.79-90
    • /
    • 2002
  • Recently, the research about color matching for the input/output devices of printing process is progressing rapidly by the digitization. The calibration method of flatbed scanner widely used as an input device for prepress process is especially important for color proofing of high quality color prints. In this paper, scanner calibration method using 3-dimensional look-up table and tetrahedral interpolation was examined and analysed comparatively on the three kinds of original copies, such as photograph, dye sublimation proof and ink jet print for IT8.T/2 target.

  • PDF

Stabilization Splint Fabrication Using Computer-Aided Design/Computer-Aided Manufacturing and Three-Dimensional Printing

  • Sohn, Byung-Jin;Kim, Wook;Kim, Jea-Hong;Baik, Un-Bong
    • Journal of Oral Medicine and Pain
    • /
    • v.44 no.2
    • /
    • pp.74-76
    • /
    • 2019
  • A conservative treatment approach to temporomandibular disorder (TMD) is recommended as the first line of management, usually with a stabilization splint. Recently, computer-aided design/computer-aided manufacturing and three-dimensional printer has been widely used in the dentistry since several years ago. The authors apply digital dentistry in oral medicine fields to make stabilization splint for TMD treatment.