• 제목/요약/키워드: Three Dimensional Enclosure

검색결과 27건 처리시간 0.022초

색상 포착 기법과 수치계산을 이용한 3차원 밀폐 공간내의 자연대류 연구 (The natural convection in a three dimensional enclosure using color capturing technique and computation)

  • 이기백;김태영;양장식
    • 대한기계학회논문집B
    • /
    • 제21권12호
    • /
    • pp.1595-1607
    • /
    • 1997
  • The natural convection of a horizontal layer heated from below in a three-dimensional rectangular enclosure was dealt with both numerically and experimentally. The aspect ratios are 1:2:3.5 and Boussinesq fluid is water with the Prandtl number of 5.0. This experimental study showed how to measure the variation of temperature field in a 3-D rectangular enclosure with small aspect ratios by using TLC(Thermochromic Liquid Crystal) and color capturing technique. The experimental temperature field had periodic characteristics of 75 sec at Ra=2.37*10$^{5}$ . But the numerical convection flow had periodic characteristics of 79 sec at the same Rayleigh number. In three dimensional computation it was found that the convection roll structure bifurcated from four rolls to two rolls as the Rayleigh number is increased.

원형 실린더가 존재하는 밀폐계의 종횡비 변화가 3차원 자연대류 현상에 미치는 영향 (Effect of Aspect Ratio of Enclosure with Inner Circular Cylinder on Three-Dimensional Natural Convection)

  • 이정민;서영민;하만영
    • 대한기계학회논문집B
    • /
    • 제40권11호
    • /
    • pp.717-726
    • /
    • 2016
  • 본 연구는 밀폐계 내부에 고온의 원형 실린더가 존재할 때, 밀폐계의 종횡비 변화에 따른 밀폐계 내부의 3차원 자연대류 현상에 대해 수치해석을 수행하였다. 밀폐계 내부의 원형 실린더는 유한체적법(FVM)에 기초한 가상 경계법(IBM)을 사용하여 구현하였다. 본 연구에서 고려한 Rayleigh 수의 범위는 $10^5{\leq}Ra{\leq}10^6$이며, Prandtl 수는 0.7이다. 밀폐계의 폭을 변화하여 밀폐계의 종횡비를 증가시켰으며, 밀폐계의 종횡비는 $1{\leq}W/L{\leq}4$ 범위에서 1 간격으로 고려하였다. 본 연구에서 고려한 모든 Rayleigh 수와 밀폐계의 종횡비 범위에서 열유동장은 x=0 단면을 기준으로 좌우 대칭을 이루며 정상상태에 도달하였다. 또한 밀폐계의 종횡비가 증가할수록 원형 실린더의 표면 평균 Nusselt수는 증가하는 반면, 밀폐계 벽면의 표면 평균 Nusselt수는 감소하였다.

옥외 전기시설물 침수시 누설전류에 의한 인체영향 (Human Hazard by Outdoor Electrical Facilities in Submerged Area)

  • 하태현;이현구;배정효;김대경
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권12호
    • /
    • pp.602-607
    • /
    • 2003
  • We show three-dimensional distribution of voltages resulted from the leakage current originated from outdoor electrical facilities in a submerged area. In case these facilities are grounded by the neutral line multiple grounding method, the existence of ungrounded electrical facilities can cause a disastrous effect on near-by passengers. In order to investigate this situation, we installed a real-scale test field for the experiment type I (for the leakage current path between a enclosure grounded electrical facility and another enclosure grounded one), and that for the experiment type II (for the leakage current path between a enclosure grounded electrical facility and another ungrounded one). For both cases, we carried out three-dimensional monitoring of the voltage distribution while varying additional conditions such as the exposure of the underground cables and the finishing of cable connection part. The result shows that a disastrous effect on human safety can arise from the leakage current without a pertinent measure for the construction and maintenance of outdoor electrical facilities.

불규칙한 3차원 형상에 응용된 구분종좌표보간법 (Discrete Ordinates Interpolation Method Applied to Irregular Three-Dimensional Geometries)

  • 차호진;송태호
    • 대한기계학회논문집B
    • /
    • 제24권6호
    • /
    • pp.814-821
    • /
    • 2000
  • The Discrete Ordinates Interpolation Method (DOIM) is tested in three-dimensional enclosures. The radiative transfer equation (RTE) is solved for a linear source term and the DOIM is formulated for a gray medium. Several interpolation methods can be applied to the DOIM scheme. Among them, the interpolation method applicable to an unstructured grid system is discussed. In a regular hexahedron enclosure, radiative wall heat fluxes are calculated and compared with exact solutions. The enclosure has an absorbing, emitting and nonscattering medium and a constant temperature distribution. These results are obtained with varying optical depths (xD = 0.1, 1.0, 10.0). Also, the same calculations are performed in an irregular hexahedron enclosure. The DOIM is applied to an unstructured grid system as well as a structured grid system for the same regular hexahedron enclosure. They are compared with the exact solutions and the computational efficiencies are discussed. When compared with the analytic solutions, results of the DOIM are in good agreement for three-dimensional enclosures. Furthermore, the DOIM can be easily applied to the unstructured grid system, which proves the reliability and versatility of the DOIM.

돌출 열원을 갖는 3차원 밀폐 공간내에서의 자연대류-복사 복합 열전달에 대한 실험적 및 수치적 연구 (An experimental and numerical study on natural convection-radiation conjugate heat transfer in a three-dimensional enclosure having a protruding heat source)

  • 백창인;이관수;김우승
    • 대한기계학회논문집B
    • /
    • 제20권10호
    • /
    • pp.3344-3354
    • /
    • 1996
  • An experimental and numerical study on the three-dimensional natural convection-radiation conjugate heat transfer in the enclosure with heat generating chip has been performed. A 3-dimensional simulation model is developed by considering heat transfer phenomena by conduction-convection and radiation. Radiative transfer was analyzed with the discrete ordinates method. Experiments are conducted in order to validate the numerical model. Comparisons with the experimental data show that good agreement is obtained when the radiation effect is considered. The effects of the thermal conductivity of the substrate and power level on heat transfer are investigated. It is shown that radiation is the dominant heat transfer mode and the conductivity of the substrate has important effects on the heat transfer in the enclosure.

축대칭 원통좌표계에서 수정된 구분종좌법에 의한 복사열전달 해석 (Radiation in axisymmetric cylindrical coordinates with the modified discrete-ordinates method)

  • 김만영;백승욱
    • 대한기계학회논문집B
    • /
    • 제22권2호
    • /
    • pp.213-220
    • /
    • 1998
  • The conventional discrete-ordinates method (DOM) is modified and developed for the analysis of two-dimensional axisymmetric cylindrical enclosure with curved wall. The objective of the present work is to extend the capability of the conventional DOM into a general axisymmetric geometry like nozzle-shaped enclosure, by adopting the arbitrary control angle as was done in the finite-volume method (FVM), while keeping the same two-dimensional solution procedure as in the conventional DOM. The present method is validated by applying it to three different benchmark problems of axisymmetric enclosure containing absorbing, emitting and scattering medium. Results presented in this work not only support the solution accuracy, but also moderate efficiency in the numerical calculation of axisymmetric radiation problem.

내부 원형 실린더의 크기가 정육면체 밀폐계 내부의 3 차원 자연대류 현상에 미치는 영향 (Effect of Inner Circular Cylinder Size on Three-Dimensional Natural Convection in Cubical Enclosure)

  • 서영민;최창영;하만영;박상후
    • 대한기계학회논문집B
    • /
    • 제38권12호
    • /
    • pp.975-982
    • /
    • 2014
  • 본 연구는 정육면체 밀폐계 내부에 존재하는 고온의 원형 실린더의 크기 변화에 따른 밀폐계 내부의 3 차원 자연대류 현상에 대한 수치해석을 수행하였다. 본 연구에서 고려한 Rayleigh 수는 $10^3$부터 $10^5$까지며 Prandtl 수는 0.7 이다. 내부 원형 실린더의 반경은 0.1L 부터 0.4L 범위에서 0.1L 간격으로 변경하였다. 본 연구에서 고려한 모든 Rayleigh 수와 실린더 반경의 범위에서 열유동장은 정상 상태의 특성을 보였다. 내부 원형 실린더의 크기가 증가하여 실린더 표면과 밀폐계 벽면이 가까워 질수록 실린더 표면과 밀폐계 벽면의 평균 Nusselt 수는 증가하였다. 내부 원형 실린더의 크기 변화에 따른 정육면체 밀폐계 내부의 자연대류 현상은 온도장, 유동장 및 표면 평균 Nusselt 수의 분포를 바탕으로 분석하였다.

홀로그래피 간섭 토모그래피 개발 및 3차원 자연대류 열전달에의 적용 (Development of a Holographic Interferometric Tomography System and Its Application to Three-Dimensional Natural Convection)

  • 이수만;강민구;차동진;주원종;강보선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1609-1614
    • /
    • 2003
  • In this study, a practical holographic interferometric tomography system, which is instantaneous and non-contact for measuring three dimensional flow field, was developed. The system consists of holographic recording/reconstruction system, fringe analysis code and computational tomography code and it is developed with Gill environment for general users. The developed system was applied to three-dimensional natural convection from a discrete flush-mounted circular heat source on the bottom of a cubic enclosure. The heat source was located at the off-center of the bottom plate so that three-dimensional temperature field can be achieved. A set of multi-directional holographic interferograms was recorded by employing a double-reference beam, double-exposure holographic technique. Optical pathlength data were extracted from the recorded interferometric data and finally three dimensional temperature field inside the cube was reconstructed.

  • PDF

홀로그래피 간섭 토모그래피를 이용한 3 차원 자연대류 해석 (Analysis of Three-Dimensional Natural Convection Using a Holographic Interferometric Tomography)

  • 심동식;이수만;강보선;차동진;주원종
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.497-502
    • /
    • 2001
  • Three-dimensional natural convection from a discrete flush-mounted circular heat source on the bottom of a cubic enclosure was studied by using a holographic interferometric tomography. The heat source was located at the off-center of the bottom plate so that three-dimensional temperature field can be achieved. A set of multidirectional holographic interferogram was recorded by employing a double-reference beam, double-exposure holographic technique in order to eventually reconstruct the temperature fields. The recorded interferometric data appear good enough to be further processed to extract optical pathlength data from them and finally reconstruct the temperature fields. A complete analysis of the temperature fields including the field reconstructions and comparison with thermocouple measurements is underway and will be reported shortly.

  • PDF