• Title/Summary/Keyword: Thin membrane

Search Result 524, Processing Time 0.028 seconds

Pervaporation of Organic Solvents using Plasma Polymerized Thin Film (플라즈마 중합박막을 이용한 유기용매의 투과증발)

  • Kim, Sung-O;Park, Bok-Kee;Kim, Du-Seok;Park, Jin-Kyu;Ryu, Seong-Ryal;Lee, Jin;Ra, Dong-Kyun;Lee, Deok-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1702-1703
    • /
    • 1999
  • We have prepared the plasma-polymerized membrane for pervaporation of organic-liquid mixtures by the plasma polymerization technique. Plasma polymerization techniques were utilized in the development of hydrophilic composite membranes having high hydrogen ion permeability and excellent dimensional stability. To develop an organic liquid permselective membrane. suppressing membrane swelling as well as enhancing the solubility difference is important, the objectives of the present study are to design a suitable membrane for an organic-mixture system by the control of the plasma-polymer solubility.

  • PDF

Nonlinear aerodynamic stability analysis of orthotropic membrane structures with large amplitude

  • Zheng, Zhoulian;Xu, Yunping;Liu, Changjiang;He, Xiaoting;Song, Weiju
    • Structural Engineering and Mechanics
    • /
    • v.37 no.4
    • /
    • pp.401-413
    • /
    • 2011
  • The aerodynamic stability of orthotropic tensioned membrane structures with rectangular plane is theoretically studied under the uniform ideal potential flow. The aerodynamic force acting on the membrane surface is determined by the potential flow theory in fluid mechanics and the thin airfoil theory in aerodynamics. Then, based on the large amplitude theory and the D'Alembert's principle, the interaction governing equation of wind-structure is established. Under the circumstances of single mode response, the Bubnov-Galerkin approximate method is applied to transform the complicated interaction equation into a system of second order nonlinear differential equation with constant coefficients. Through judging the stability of the system characteristic equation, the critical divergence instability wind velocity is determined. Finally, from different parametric analysis, we can conclude that it has positive significance to consider the characteristics of orthotropic and large amplitude for preventing the instability destruction of structures.

Focused Ion Beam Milling for Nanostencil Lithography (나노스텐실 제작을 위한 집속이온빔 밀링 특성)

  • Kim, Gyu-Man
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.2
    • /
    • pp.245-250
    • /
    • 2011
  • A high-resolution shadow mask, a nanostencil, is widely used for high resolution lithography. This high-resolution shadowmask is often fabricated by a combination of MEMS processes and focused ion beam (FIB) milling. In this study, FIB milling on 500-nm-thin SiN membrane was tested and characterized. 500 nm thick and $2{\times}2$ mm large membranes were made on a silicon wafer by micro-fabrication processes of LPCVD, photolithography, ICP etching and bulk silicon etching. A subsequent FIB milling enabled local membrane thinning and aperture making into the thinned silicon nitride membrane. Due to the high resolution of the FIB milling process, nanoscale apertures down to 60 nm could be made into the membrane. The nanostencil could be used for nanoscale patterning by local deposition through the apertures.

Preparation of Zeolite-Filled PDMS Membranes and Its Properties for Organic Vapor Separation

  • Kim, Min-Joung;Youm, Kyung-Ho
    • Korean Membrane Journal
    • /
    • v.2 no.1
    • /
    • pp.48-55
    • /
    • 2000
  • In order to improve organic vapor separation efficiency of polydimethylsiloxane (PDMS) membrane, various zeolites (zeolite 4A, zeolite 13X and natural zeolite) were introduced into a thin PDMS film. The measurements of permeability and selectivity of zeolite-filled PDMS membranes were carried out with a CO$_2$gas and a CO$_2$gas/acetic acid vapor mixture, respectively. The CO$_2$permeability of zeolite-filled membranes decreased with increasing zeolite content and then recovered up to 30 wt% content. The effect of zeolite type on the improvement of CO$_2$permeability was found to be in the order of zeolite 13X > natural zeolite > 4A. The CO$_2$selectivity of zeolite-filled membranes was enhanced up to 9 times compared with the selectivity of a pure (unfilled) PDMS membrane. The effect of zeolite type on the improvement of CO$_2$selectivity was found to be in the order of natural zeolite > zeolite 13X > zeolite 4A.

  • PDF

Development of Metal Substrate with Multi-Stage Nano-Hole Array for Low Temperature Solid Oxide Fuel Cell (저온 고체산화물연료전지 구현을 위한 다층 나노기공성 금속기판의 제조)

  • Kang, Sangkyun;Park, Yong-Il
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.12 s.283
    • /
    • pp.865-871
    • /
    • 2005
  • Submicron thick solid electrolyte membrane is essential to the implementation of low temperature solid oxide fuel cell, and, therefore, development of new electrode structures is necessary for the submicron thick solid electrolyte deposition while providing functions as current collector and fuel transport channel. In this research, a nickel membrane with multi-stage nano hole array has been produced via modified two step replication process. The obtained membrane has practical size of 12mm diameter and $50{\mu}m$ thickness. The multi-stage nature provides 20nm pores on one side and 200nm on the other side. The 20nm side provides catalyst layer and $30\~40\%$ planar porosity was measured. The successful deposition of submicron thick yttria stabilized zirconia membrane on the substrate shows the possibility of achieving a low temperature solid oxide fuel cell.

Removal of Pollutants and Recovery of Toxic Heavy Metals from Wastewater Using Microporous Hollow Fiber Modules

  • Yun, Chang-Han
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1993.04a
    • /
    • pp.25-27
    • /
    • 1993
  • Multiphase equilibrium-based processes for separation and purification generally utilize dispersed systems in which one phase is dispersed in the other as bubbles or drops or thin films. Using microporous membranes, novel techniques have been developed such that multiphase processes can now be carried out in a nondispersive fashion for gas-liquid (Sirkar, 1992) and liquid-liquid (Prasad and Sirkar, 1992) contacting processes. Among such processes, only nondispersive solvent extraction of pollutants using microporous membranes will be of concern here. These processes employ immobilized immiscible phase interfaces at the pore mouths in a microporous membrane. Through such interfaces, solutes are extracted into the solvent as two immiscible phases flow on two sides of a microporous membrane. Many advantages of such a technique over conventional dispersion-based extractors have been summarized (Prasad and Sirkar, 1992).

  • PDF

Characteristics of Nafion Membranes with Pd Thin Films Deposited by DC Magnetron Sputtering Technique (DC마그네트론 스퍼터링으로 Pd박막 입힌 Nafion막의 특성)

  • Hwang, Gi-Ho;Cho, Won-Il;Cho, Byung-Won;Yoon, Sung-Ryul;Ha, Heung-Yong;Oh, In-Hwan;Kim, Kwang-Bum
    • Journal of the Korean Electrochemical Society
    • /
    • v.5 no.2
    • /
    • pp.68-73
    • /
    • 2002
  • Modified polymer electrolyte membranes were fabricated by the applying dc magnetron sputter-deposited Pd thin layers on the surface of the $Nafion^{TM}$ membranes in argon atmosphere. The Pd thin films were characterized by investigating its morphology, methanol permeability, and protonic conductivity. The performance of a direct methanol fuel cell(DMFC) with the modifed polymer electrolyte membrane was also tested by the measurement of its currents and voltages under flowing methanol. The Pd thin film could be a barrier layer to methanol crossover, but the protonic conductivity of the modified polymer membrane was reduced. By using the modified polymer eletrolyte membranes, both the methanol permeability and the protonic conductivity were decreased with increasing the thickness of Pd thin film. However, the performances of DMFC were almost independent on the thickness of Pd thim films. The efffcts of methanol concentration in a feeding fuels on the protonic conductivity and the cell performance were also investigated.

Substrate Effects on the Response of PZT Infrared Detectors (상이한 기판조건에 따른 PZT 적외선 감지소자의 성능 변화)

  • Go, Jong-Su;Gwak, Byeong-Man;Liu, Weiguo;Zhu, Weiguang
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.3
    • /
    • pp.428-435
    • /
    • 2002
  • Pyroelectric $Pb(Zr_{0.3}Ti_{0.7})O_3$ (PZT30/70) thin film IR detectors has been fabricated and characterised. The PZT30/70 thin film was deposited onto $Pt/Ti/Si_3N_4/SiO_2/Si$ substrate by the sol-gel process. Four different substrate conditions were studied for their effects on the pyroelectric responses of the IR detectors. The substrate conditions were the combinations of the Si etching and the Pt/Ti patterning. In the Si etched substrate, the $Si_3N_4/SiO_2$ composite layer was used as silicon etch-stop, and was used as the membrane to support the PZT pyroelectric film element as well. The measured pyroelectric current and voltage responses of detectors fabricated on the micro-machined thin $Si_3N_4/SiO_2$ membrane were two orders higher than those of the detectors on the bulk-silicon. For detectors on the membrane substrate, the Pt/Ti patterned detectors showed a 2-times higher pyroelectric response than that of not-patterned detectors. On the other hand, the pyroelectric response of the detectors on the not-etched Si substrate was almost the same, regardless of the Pt/Ti patterning. It was also found that the rise time strongly depended on the substrate thickness: the thicker the substrate was, the longer the rise-time.

Long-term Prognosis of thin Glomerular Basement Membrane Nephropathy in Children: A Retrospective Single Center Study

  • Lim, Myung Hee;Bae, Hee Jung;Jang, Kyung Mi;Park, Yong Hoon
    • Childhood Kidney Diseases
    • /
    • v.21 no.2
    • /
    • pp.41-46
    • /
    • 2017
  • Purpose: Thin glomerular basement membrane nephropathy (TBMN) is, along with the IgA nephropathy, the most common cause of asymptomatic hematuria in Korean children. TBMN is usually a benign renal disease not requiring treatment and is associated with a good prognosis, but some cases hematuria is indicative of a state of progressive renal insufficiency. We aimed to retrospectively evaluate clinical manifestations and renal prognosis of patients with TBMN. Methods: Among the 428 renal biopsies performed on children at Yeungnam University Hospital between January 2000 and February 2017, 167 patients were diagnosed as having TBMN. We retrospectively investigated 167 pediatric patients and identified 59 children with follow-up duration >3 years. Results: Among 59 patients, there were 33 boys and 26 girls. Mean age of onset of hematuria was $7.18{\pm}2.64$ years, and mean time from onset of disease until a renal biopsy was performed was $2.48{\pm}2.10$ years. There were no clinical features or laboratory findings among studied children to indicate decreased renal function during follow-up; however, one case progressed to chronic kidney disease (CKD) due to an unknown cause. There were seven patients among these related a positive family history of hematuria or renal insufficiency. Concluson: Although almost all patients had normal renal functions during follow-up, there were one patient who progressed to CKD and seven patients with family history of hematuria or renal insufficiency. Moreover, four among the 428 patients over 17 years underwent repeat renal biopsies, which showed results different from their earlier biopsies.Thus, large-scales studies may be required to determine long-term prognosis of TBMN in children, and further evaluation for Alport syndrome in TBMN cases is essential.

Thin Glomerular Basement Membrane Disease with Herlyn-Werner-Wunderlich Syndrome : Uterus Didelphys, Blind Hemivagina and Ipsilateral Renal Agenesis (비박형 사구체 기저막 질환이 동반된 중복 자궁 일측성 폐쇄질 및 동측 신장 무형성 증후군 ( Herlyn - Werner- Wunderlich syndrome ) 1례)

  • Kim, Myoung-Soo;Park, Yong-Jun;Park, Young-Jun;Park, Noh-Hyuck;Song, Ji-Sun;Kim, Pyung-Kil
    • Childhood Kidney Diseases
    • /
    • v.11 no.2
    • /
    • pp.299-305
    • /
    • 2007
  • Herlyn-Werner-Wunderlich syndrome(HWWs) is a rare variant of Mullerian ductal anomalies characterized by the presence of a hemivaginal septum, a didelphic uterus, and ipsilateral renal agenesis. It usually presents after menarche with progressive pelvic pain, and palpable mass due to hemihematocolpos. If a cystic mass is detected behind the urinary bladder in children, in association with the absence of a kidney, the diagnosis of uterus didelphys with imperforate vagina and hydrocolpos should be considered. When renal agenesis is found in asymptomatic children, the small size and the tubular shape of the uterus makes it almost impossible to evaluate uterine anomalies, so follow-up should be performed until the end of puberty. Appropriate preoperative diagnosis and treatment will prevent unnecessary procedures and offer relief of symptoms. We report one case of didelphic uterus with blind hemivagina and ipsilateral renal agenesis with biopsy- proven thin glomerular basement membrane disease which is not related to the above syndrome.

  • PDF