• Title/Summary/Keyword: Thickness changes

Search Result 1,709, Processing Time 0.03 seconds

Effect of Strength Training Combined with Blood Flow Restriction Exercise on Leg Muscle Thickness in Children with Cerebral Palsy

  • Mun, Dal-Ju;Park, Jae-Cheol
    • PNF and Movement
    • /
    • v.19 no.3
    • /
    • pp.441-449
    • /
    • 2021
  • Purpose: The purpose of this study was to investigate the effect of strength training combined with blood flow restriction on leg muscle thickness in children with cerebral palsy. Methods: Nineteen children with cerebral palsy, aged between five and 10 years of age, living in area N, were recruited. Ten participants were classified into a blood flow restriction group and nine into a strength exercise group. The experimental group performed strength training using a blood flow restriction cuff on the leg, and the control group performed strength training without blood flow restriction. A paired t-test was performed to confirm intragroup changes before and after five weeks of the experiment, and an independent t-test was performed to confirm intergroup changes, and the significance level was α=0.05. Results: The rectus femoris, gastrocnemius and gluteus medius muscles showed significant differences in the groups after five weeks (p<0.05). There was a significant difference between the groups in the rectus femoris and gastrocnemius after five weeks (p<0.05). Conclusion: As a result of this study, it was found that strength training combined with blood flow restriction had a positive effect on the changes in leg muscle thickness in children with cerebral palsy. This suggests the possibility of using it in the future as basic data for strength training methods and blood flow restriction exercises for children with cerebral palsy.

Secondary Phase and Defects in Cu2ZnSnSe4 Solar Cells with Decreasing Absorber Layer Thickness

  • Kim, Young-Ill;Son, Dae-Ho;Lee, Jaebaek;Sung, Shi-Joon;Kang, Jin-Kyu;Kim, Dae-Hwan;Yang, Kee-Jeong
    • Current Photovoltaic Research
    • /
    • v.9 no.3
    • /
    • pp.84-95
    • /
    • 2021
  • The power conversion efficiency of Cu2ZnSnSe4 (CZTSe) solar cells depends on the absorber layer thickness; however, changes in the characteristics of the cells with varying absorber layer thickness are unclear. In this study, we investigated the changes in the characteristics of CZTSe solar cells for varying absorber layer thickness. Five absorber thicknesses were employed: CZTSe1 2.78 ㎛, CZTSe2 1.01 ㎛, CZTSe3 0.55 ㎛, CZTSe4 0.29 ㎛, and CZTSe5 0.15-0.23 ㎛. The efficiency of the CZTSe solar cells decreased as the absorber thickness decreased, resulting in power conversion efficiencies of 10.45% (CZTSe1), 8.67% (CZTSe2), 7.14% (CZTSe3), 3.44% (CZTSe4), and 1.54% (CZTSe5). As the thickness of the CZTSe absorber layer decreased, the electron-hole recombination at the grain boundaries and the absorber-back-contact interface increased. This caused an increase in the current loss, owing to light loss in the long-wavelength region. In addition, as the thickness of the CZTSe absorber layer decreased, more ZnSe was produced, and the resulting defects and defect clusters led to an open-circuit voltage loss.

Immediate Effect of the Application of IASTM Using Microcurrent and a Flossing Band and on Changes in the Thickness of the Lower Extremity Fascia in Patients with Intrinsic Patellofemoral Pain Syndrome (잠재적인 무릎넙다리 통증 증후군 환자에게 미세전류를 이용한 IASTM과 플로싱 밴드 적용이 하지 근막의 두께 변화에 미치는 즉각적 효과)

  • Se-hun Kim;Seong-hun Yu;Tae-won Kim;Seong-hwan Kim;Se-jin Park
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.30 no.1
    • /
    • pp.85-93
    • /
    • 2024
  • Background: This study examined the Immediate effects of IASTM using microcurrent and the flossing band on the lower extremity fascia thickness in subjects with Intrinsic patellofemoral pain syndrome. Methods: Sixty-six subjects with patellofemoral pain syndrome were randomized into three groups (22 each in the microcurrent IASTM (instrument assisted soft-tissue mobilization) group, and flossing band group, and combined microcurrent IASTM and flossing band group) to evaluate the immediate effects of the lower extremity fascia thickness before and after intervention. The thickness of the lower extremity fascia was measured using an ultrasound machine. Using SPSS Window. 22.0, a Shapiro Wilk was conducted to test the normality of all variables; within-group comparisons were made with a paired-samples t-test, and between-group interventions were subjected to a one-way analysis of variance. Results: Changes in the thickness of the fascia in the thigh area were observed before and after intervention in all three groups. There was a significant decrease, and in the combined group, there was a significant decrease in fascia thickness compared to when the IASTM group and the flossing band group were applied separately (p<.05). Conclusion: Through this study, the effect on fascia thickness was confirmed when IASTM and flossing band intervention were combined, and it is believed that it can be used as basic clinical data for patients with knee-thigh pain syndrome.

  • PDF

A Study of Panel Denting (판넬의 덴팅에 관한 연구)

  • Jung, Dong-Won
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.610-615
    • /
    • 2001
  • In the interest of improved automotive fuel economy, one solution is reducing vehicle weight. Achieving significant weight reductions will normally require reducing the panel thickness or using alternative materials such as aluminum alloy sheet. These changes will affect the dent resistance of the panel. In this study, the correlation between panel size, curvature, thickness, material properties and dent resistance is investigated. A parametric approach is adopted, utilizing a "design software" tool incorporating empirical equations to predict denting and panel stiffness for simplified panels. The developed design program can be used to minimize panel thickness or compare different materials, while maintaining adequate panel performance.

  • PDF

Experimental Study for Hydraulic Characteristics as the Permeable Underlayer Thickness of Rubble mound Structure (사석방파제 투수하부층 두께에 따른 사면상의 수리특성 실험연구)

  • 윤한삼;김종욱;류청로
    • Journal of Ocean Engineering and Technology
    • /
    • v.16 no.3
    • /
    • pp.40-45
    • /
    • 2002
  • In this study, the effects on hydraulic characteristics are discussed as the permeable underlayer thickness of the rubble mound structure changes. A series of hydraulic experiments were performed and wave run-up, reflection and set-up were investigated. Result indicated that wave run-down was affected by the water out from the permeable underlayer during down-rush. As the thickness increased, relative wave run-up decreased.

Influence of Ring Gear Boundary Conditions on the Static Characteristics of Epicyclic Gear Trains with Manufacturing Errors (링기어의 경계조건이 가공오차를 가지는 유성기어열의 정특성에 미치는 영향)

  • Cheon, Gill-Jeong;Oh, Jae-Kook
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1775-1780
    • /
    • 2003
  • A hybrid finite element analysis was used to analyze the influence of ring gear rim thickness and spline number on the static properties of an epicyclic gear system with manufacturing errors. Both of these parameters affected the bearing force and critical stress. The effect of changes in the rim thickness on the load sharing between the gears depended on the type of manufacturing error. Ring flexibility improved the load sharing between planetary gears only in systems with planet tooth thickness or planet tangential errors; for other types of error, ring flexibility worsened the load sharing. To improve load sharing, rim thickness and spline number should be controlled within a specific range. The effect of the ring gear boundary condition was more apparent in a system with errors than in a normal system.

  • PDF

Effect of CranioCervical Flexion Exercise Using Sling on Thickness of Sternocleidomastoid Muscle and Deep Cervical Flexor Muscle (슬링을 이용한 머리목굽힘운동이 목빗근과 심부목굽힘근의 두께에 미치는 영향)

  • Yun, Ki Hyun;Kim, Kyoung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.2
    • /
    • pp.253-261
    • /
    • 2013
  • PURPOSE: The Purpose of this study was to investigate the changes in the thickness of Sternocleidomastoid muscle(SCM) and deep cervical flexor muscle(DCF) through CranioCervical Flexion Exercise(CCFEx) Using Sling. METHODS: Subjects were randomly allocated two group: control group (n=21) without neck pain, experimental group (n=17) with pain. Muscle thickness was measured using CranioCervical Flexion Test(CCFT) and ultrasonography before or after intervention. RESULTS: In experimental group, compared with muscle thickness of exercise before, SCM thickness rate of change was slightly decreased according to pressure increased after exercise(p<.05). CONCLUSION: The results of this study showed that CCFEx using sling is effective for SCM and DCF of choric neck pain patients.

Ultrasonographic evaluation of skin thickness in small breed dogs with hyperadrenocorticism

  • Heo, Seonghun;Hwang, Taesung;Lee, Hee Chun
    • Journal of Veterinary Science
    • /
    • v.19 no.6
    • /
    • pp.840-845
    • /
    • 2018
  • The purpose of this study was to propose a standard for differentiation between normal dogs and patients with hyperadrenocorticism (HAC) by measuring skin thickness via ultrasonography in small breed dogs. Significant changes in skin thickness of patients treated with prednisolone (PDS) or patients with HAC treated with trilostane were evaluated. Skin thickness was retrospectively measured on three abdominal digital images obtained from small breed dogs weighing < 15 kg that underwent abdominal ultrasonography. Mean skin thickness of normal dogs was $1.03{\pm}0.25mm$ (mean ${\pm}$ SD). Both the HAC and PDS groups showed significantly thinner skin than that in the normal group. Seven of the 10 HAC patients treated with trilostane had increased skin thickness. The area under the curve value of 0.807 was based on the receiver operating characteristics (ROC) curve for differentiating normal dogs from HAC patients. Sensitivity was 76% and specificity was 73% when skin thickness was less than the 0.83 mm cutoff value. In conclusion, measurement of skin thickness in small breed dogs by using ultrasonography is likely to provide clinical information useful in differentiating HAC patients from normal dogs. However, exposure to PDS, trilostane, and other conditions may have a significant effect on skin thickness.

Subjective Hand and Physical Properties of Tricot based Artificial Suede according to Raising Finish (기모가공 조건에 따른 트리코 기포 인조 스웨이드의 태와 물성)

  • Roh, Eui Kyung;Oh, Kyung Wha
    • Fashion & Textile Research Journal
    • /
    • v.16 no.1
    • /
    • pp.153-159
    • /
    • 2014
  • This study evaluates the changes of the subjective hand, preference, comfort and mechanical properties of tricot based artificial suede made from sea-island type micro fibers according to raising condition. The subjective hand and the preference of raised suede for jacket were rated by the 20's and 30's women experts according to raising cycles. Comfort properties were evaluated by air permeability, water vapor transmission, and thermal transmission. Mechanical properties were measured by the KES-FB system. The subjective hand of artificial suede was categorized into three hand factors: smoothness, warmness and thickness. Smoothness, warmness and thickness perception increased with raising cycles which affected hand preference and luxuriousness perception. The thickness and wale density of suede increased with the number of raising. Suede became more compact and less pliable and less stretchable due to increased fabric thickness; in addition, the surface of suede became smoother and compressive since the surface evenness of suede improved with smaller fiber fineness and an increased amount of naps covered the base fabric. Furthermore, water vapor transmission decreased and thermal insulation increased. The best raising conditions for artificial suede was four cycles in which artificial suede was preferred without changes in physical properties.

The suggestion of Proper Pressure level in Cranio-Cervical Flexion Exercise for Deep Cervical Flexor by Ultrasonographic Measurement (초음파 영상을 통한 머리-목 굽힘 운동의 적정 수준 제시에 관한 연구)

  • Jun, Deok-Hoon;Fell, Dennis W.;Kim, Kyoung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.4
    • /
    • pp.497-504
    • /
    • 2011
  • Purpose : Chronic cervical pain is a common source of disability in society. There has been no research regarding the amount of pressure for the deep cervical flexors during cranio-cervical flexion exercise (CCFE). The purpose of this study is to determine optimal pressure levels to facilitate deep cervical muscles (longus colli & longus capitis) during cranio-cervical flexion exercise, using ultrasound measurement of the muscles. Methods : Using a cross-sectional design, the study was performed in an experimental group of 19 subjects (7 men, 12 women) with no cervical pain. Participants were instructed to perform the CCFE, and during the five incremental stages of the test, changes in thickness, as compared to resting baseline values, were measured using ultrasonography for sternocleidomastoid muscle (SCM) and deep cervical muscles (DCF). Results : Both DCF and SCM muscles demonstrated an increase in recruitment with each progressive phase of the test. In comparing the different pressure increments, the most significant changes found in DCF thickness were between phase 2 and phase 3 (p<.05). However no differences were found between pressure increments for SCM thickness (p>.05). Conclusion : The results suggest 26 mm Hg as the optimal pressure level during cranio-cervical flexion exercise for facilitation of deep cervical flexor.