• 제목/요약/키워드: Thickness Attenuation

검색결과 183건 처리시간 0.024초

이종 접합부재의 두께 변화에 따른 계면균열의 초음파 산란 보정 (Ultrasonic Scatter and Compensation of Interfacial Crack due to Thickness Variation of Dissimilar Bonded Components)

  • 박성일;정남용;진윤호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.25-30
    • /
    • 2004
  • In this paper, the compensation of interfacial scatter due to adhesive layer and adherend thickness ratio variation was applied to improve measuring precision by calculating ultrasonic attenuation coefficient in the Al/Epoxy dissimilar bonded components. The optimum condition of theoretical value and experimental measuring accuracy by the ultrasonic method in the Al/Epoxy dissimilar bonded components have been investigated. From the experimental results, we proposed a measurement method of the interfacial crack lengths by the ultrasonic attenuation coefficient and discussed it.

  • PDF

Bentonite based ceramic materials from a perspective of gamma-ray shielding: Preparation, characterization and performance evaluation

  • Asal, Sinan;Erenturk, Sema Akyil;Haciyakupoglu, Sevilay
    • Nuclear Engineering and Technology
    • /
    • 제53권5호
    • /
    • pp.1634-1641
    • /
    • 2021
  • Exposure to gamma-rays is hazardous for humans and other living beings because of their high penetration through the materials. For this reason, shielding materials (usually lead, copper and stainless steel) are used to protect against gamma rays. This study's objective was to prepare ceramic materials for gamma radiation shielding by using different natural bentonite clays. Gamma-ray attenuation performances of the prepared shielding materials at different thicknesses were investigated and evaluated for different gamma-ray energies from different standard point gamma radiation sources (251Am, 57Co, 137Cs, 60Co, and 88Y). The mass and linear attenuation coefficients of the prepared ceramics vary between 0.238 and 0.443 cm2 g-1 and between 0.479 and 1.06 cm-1, respectively, depending on their thicknesses. Results showed that these materials could be prioritized because of their evidential properties of gamma radiation protection in radiation applications.

Evaluation of neutron attenuation properties using helium-4 scintillation detector for dry cask inspection

  • Jihun Moon;Jisu Kim;Heejun Chung;Sung-Woo Kwak;Kyung Taek Lim
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3506-3513
    • /
    • 2023
  • In this paper, we demonstrate the neutron attenuation of dry cask shielding materials using the S670e helium-4 detector manufactured by Arktis Radiation Ltd. In particular, two materials expected to be applied to the TN-32 dry cask manufactured by ORANO Korea and KORAD-21 by the Korea Radioactive Waste Agency (KORAD) were utilized. The measured neutron attenuation was compared with our Monte Carlo N-Particle Transport simulation results, and the difference is given as the root mean square (RMS). For the fast neutron case, a rapid decline in neutron counts was observed as a function of increasing material thickness, exhibiting an exponential relationship. The discrepancy between the experimentally acquired data and simulation results for the fast neutron was maintained within a 2.3% RMS. In contrast, the observed thermal neutron count demonstrated an initial rise, attained a maximum value, and exhibited an exponential decline as a function of increasing thickness. In particular, the discrepancy between the measured and simulated peak locations for thermal neutrons displayed an RMS deviation of approximately 17.3-22.4%. Finally, the results suggest that a minimum thickness of 5 cm for Li-6 is necessary to achieve a sufficiently significant cross-section, effectively capturing incoming thermal neutrons within the dry cask.

Optimization of radiation shields made of Fe and Pb for the spent nuclear fuel transport casks

  • V.G. Rudychev;N.A. Azarenkov;I.O. Girka;Y.V. Rudychev
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.690-695
    • /
    • 2023
  • Recommendations are given to improve the efficiency of radiation protection of transport casks for SNF transportation. The attenuation of ${\gamma}$-quanta of long-lived isotopes 134Cs, 137mBa(137Cs), 154Eu and 60Co by optimizing the thicknesses and arrangement of layers of Fe and Pb radiation shields of transport casks is studied. The fixed radiation shielding mass (fixed mass thickness) is chosen as the main optimization criterion. The effect of the placement order of Fe and Pb layers in a combined two-layer radiation shield with an equivalent thickness of 30 cm is studied in detail. It is shown that with the same mass thicknesses of the Fe and Pb layers, the placement of Fe in the first layer, and Pb - in the second one provides more than twofold attenuation of ${\gamma}$-quanta compared to the reverse placement: Pb - in the first layer, Fe - in the second. The increase in the efficiency of attenuation of ${\gamma}$-quanta for TC with combined shielding of Fe and Pb is shown to be achieved by designing the first layer of radiation shielding around the canister with SNF from Fe of the maximum possible thickness.

6 MV 광자선조사면내 투과성필터에 의한 조직선량 (Scatter Dose in soft tissue using the partial attenuation filter for 6 MV X-ray of linear accelerator)

  • 최태진;김옥배
    • 한국의학물리학회지:의학물리
    • /
    • 제4권1호
    • /
    • pp.55-71
    • /
    • 1993
  • Measured and calculated the TMR and SMR factors from percent depth dose underpartial attenuators which cover the whole part of the radiation beam with variousfilter thickness from 0 to 50 mm. This study was performed for x-ray beams generated with a 6 MV linear acceleratorat source to surface distance of 100cm in a water phantom for Lipowitz metal. TMR(0,d,t) was derived from non-linear polynomial regression with field sizedifferencies and a given filter thickness. In this experiments, the TMR(0,10,50) of 50mm of filter thickness was showed13.6 % higher than that of open field and SMR(5,10,50) was 38.5% smaller than thatof open field in same depth.

  • PDF

초음파 신호분석을 이용한 접착접합 이음의 결함평가 (Evaluation of Flaws in Adhesively Bonded Joint using Ultrasonic Signal Analysis)

  • 황영택;오승규;한준영;장철섭;윤송남;이원;김환태
    • Journal of Welding and Joining
    • /
    • 제22권2호
    • /
    • pp.38-45
    • /
    • 2004
  • Ultrasonic signals transmitted through adhesively bonded plates were used to evaluate parameters related to attenuation and frequency in the adhesively bonded joint. The kinds of bonding materials with a different bonding thickness of constant pressure were used. And ultrasonic diagnosis was evaluated by p-wave sensor of 10MHz. FFT has been performed to determine bond-layer parameters such as effective thickness and frequency for adhesively bonded joint of A16061 plates in comparison with measured to theoretical ratios. When variable thickness exists, the ultrasonic spectrum was changed the frequency wave. The more materials thickness and the higher the frequency, the larger shift was observed. Measured ratios for cases of bond thickness and variety bonding materials are then used to determine bond parameters. The results show that the technique can be applied to the characterization of adhesively bonded joint.

Experimental study of the radiation shielding characteristics of new PbO-Na2O-B2O3-BaO glasses

  • M.I. Sayyed;U. Rilwan;K.A. Mahmoud;Mohamed Elsafi
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2437-2443
    • /
    • 2024
  • This work synthesized four glass samples with a fixed ratio of PbO to Na2O and a variable ratio of BaO to B2O3. The linear attenuation coefficient (LAC) (μ, cm-1) and additional attenuator parameters were determined experimentally using a semiconductor detector and different gamma sources. The comparison was carried out between the experimental and the XCOM calculated results, with good agreement emerging between the two results. The impacts of the BaO substituting for the B2O3 on fabricated PNBB glasses' radiation shielding properties were discussed. By increasing the BaO substitution concentration between 10 and 25 mol.%, the LAC μ values (cm-1) increased by 76.60 %, 13.81 %, 12.56 %, and 12.52 % for the respective γ-ray energies of 0.059, 0.662, 1.173, and 1.332 MeV. The μ value reduction with raised gamma energy values increased the values of the calculated half-value thickness (Δ0.5) as a result of the μ and Δ0.5 values' reverse proportionality. Other shielding parameters such as the lead equivalent thickness (Δeq) and radiation protection efficiency were also determined for the present PNBB glass samples.

격벽착화기 내 충격 전달에 관한 연구 (A Study on Shock Transmission of Pyrotechnic Initiator)

  • 김보훈;김민성;여재익
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2015년도 제51회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.223-226
    • /
    • 2015
  • A pyrotechnic system that consists of donor/acceptor pair separated by a gap relies on shock attenuation characteristics of the gap material and shock sensitivity of the donor and acceptor charges. We apply a level-set based multimaterial hydrocode with reactive flow models for pentolite donor and heavily aluminized RDX as acceptor charge. The complex shock interaction, critical gap thickness, acoustic impedance, and go/no-go characteristics of the pyrotechnic system are quantitatively investigated.

  • PDF

Characteristics of $\pi$-type attenuators using Ti(N) thin film resistors

  • Cuong, Nguyen Duy;Kim, Dong-Jin;Kang, Byoung-Don;Yoon, Soon-Gil
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.50-50
    • /
    • 2007
  • We report the effect of the film thickness on electrical properties of Ti(N) film resistors. The applications of titanium nitride thin film resistor in $\Pi$-type attenuators are also characterized. As film thickness decreases from 100 to 30 nm, temperature coefficient of resistance significantly decreases from -60 to -148 ppm/K, while sheet resistance increases from 37 to $270\;{\Omega}/{\square}$. The characterizations of 20dB-attenuators using thin film resistors are improved in comparison with those using thick film resistors. The $\Pi$-type attenuators using Ti(N) thin film resistors exhibit a attenuation of -19.94 dB and voltage standing wave ratio of 1.16 at a frequency of 2.7 GHz.

  • PDF

롤편심을 포함한 냉간 압연시스템의 두께제어 (Thickness Control of Cold-Rolling Mills with Roll Eccentricity)

  • 김승수;김종식;황이철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.248-254
    • /
    • 1996
  • A disturbance rejection controller using eccentricity filtering and LQ control techniques is proposed to alleviate significantly the effect of roll eccentricity in multivariable cold-rolling processes. Fundamental problems such as process time delay inherent in exit thickness measurement and non-stationary characteristics of roll eccentricity signals can be overcome by the proposed control method. The filtered instantaneous estimate of roll eccentricity may be exploited to improve instantaneous estimate of the exit thickness variation based on roll force and roll gap mearsurements, and a feedforward compensator is augmented as a reference for a gaugemeter thickness estimator. And, LQ feedback controller is combined with eccentricity filter for the attenuation of the exit thickness variation due to the entry thickness variation. The simulation results show that eccentricity components have been significantly eliminated and simultaneously other distrubances also have been attenuated.

  • PDF