• 제목/요약/키워드: Thermology

검색결과 82건 처리시간 0.018초

퇴행성 슬관절염 평가도구와 적외선 체열촬영과의 상관관계 연구 (The Study About The Correlation Between Assessment Instruments Of Knee OA and DITI)

  • 김회권;이상훈;서정철;이승덕;최선미;김용석
    • 대한한방체열의학회지
    • /
    • 제5권1호
    • /
    • pp.21-30
    • /
    • 2006
  • Objectives: The aim of this syudy is to validate the between Assessment Instruments of Knee OA and digital infrared thermographic imaging(DITI) and to find out the methods to assess knee OA by DITI. Methods: 60 subjects were evaluated. They were asked to answer VAS pain scale, WOMAC, KHAQ and LFI. Correlation was assessed by examining the spearman's rank correlation coefficients. Results: VAS, WOMAC and LFI was correlated with not only the thermal difference between Ant. knee and Post. knee, but also the lowest temperature of Ant. knee. Conclusion: DITI value was useful for evaluating the degree of OA. And we should find out that decrease of pain is correlated with change of DITI value.

  • PDF

소양인, 소음인 월경통 환자의 체표온도 비교 (A study on the thermography of dysmenorrhea patients(Soyangin, Soeumin))

  • 최윤희;조정훈;장준복;이경섭
    • 대한한방체열의학회지
    • /
    • 제5권1호
    • /
    • pp.31-36
    • /
    • 2006
  • Dysmenorrhea is one of the most common gynecologic disorders in menstruating women. Dysmenorrhea refers to the pain appearing in the lower abdomen and lower back before. after or during menstruation. In oriental medicine. the causes of dysmenorrhea have been recognized as something penetrated such as qi. blood. and pathologic factors. The purpose of this study was to observe the difference in the temperature between the Soyangin dysmenorrhea patients group and the Soeumin dysmenorrhea patients group by thermography. We observed the 55 dysmenorrhea patients that visited ** Oriental Medicine center from July 19 to August 27. 2004. We diagnosed the constitution by QSCCII and the body temperature was assessed by DITI. Thermographic measurements were performed on 3 areas(Chon-jung(CV17), Chung-wan (CV12), Kwan-won(CV4)). In this study we observed that the temperature of Chon-jung(CV17) is the highest and Chung-wan (CV12) is higher than Kwan-won(CV4). The temperature of Soeumin group is higher than that of Soyangin group in all areas and there is a significant difference in 3 area temperature between Soeumin group and Soyangin group.

  • PDF

적외선(赤外線) 체열촬영(體熱撮影)을 이용한 복부구법(腹部灸法)이 복부(腹部) 및 수장(手掌)의 온도에 미치는 영향 (The Effect of Abdominal-Moxibustion on Abdomen and Palm Temperature by D.I.T.I.)

  • 나효석;정아롱;정은아;공현우;정경숙;김경혜
    • 대한한방체열의학회지
    • /
    • 제5권1호
    • /
    • pp.37-45
    • /
    • 2006
  • Purpose: The purpose of this study is to report the effects of Abdomial-Moxibustion on abdomen and palm temperature Methods: This study was performed on 42 patients with gastrointestinal trouble, lower abdominal symptoms or hand cold(or hot) hypersensitivity to observe difference in temperature of skin surface between before and after 5 times abdominal-moxibustion using digital infrared themographic imaging(D.I.T.I) Results: After 5 times moxibustion, temperature $difference({\Delta}t)$ on chest. abdomen and palm is reduced each other. Besides the symptoms of patient are alleviated Conclusion: This study showed that abdominal-moxibustion is reducing temperature difference on the body.

  • PDF

인삼양영탕(人蔘養榮湯) 투여로 호전된 갱년기장애(更年期障碍) 15예(例)에 대한 임상고찰

  • 조성희;양승정;박경미;조현정;정지예;반혜란
    • 대한한방체열의학회지
    • /
    • 제5권1호
    • /
    • pp.59-68
    • /
    • 2006
  • Objective: The purpose of this study is to evaluate the effects of Insamyang-yeongtang on menopausal disorder patients Methods : We surveyed 15 menopausal disorder patients who had been administered Insamyang-yeongtang. The patients of menopausal disorder had been estimated twice with Kupperman's index. Result : When patients had been not administered Insamyang-yeongtang. the mean of Kupperman's index score are $42.73(SD{\pm}19.16)$. When administered Insamyang-yeongtang, the mean of kupperman's index score are $25.87(SD{\pm}19.16)$. The difference mean of first and last score are 16.87(p-value 0.001). Conclusion : This study suggests that Insamyang-yeongtang is significantly effective on menopausal disorder patients.

  • PDF

적외선 체열촬영을 이용한 배변습관과 하복 및 수족 냉증의 관련성 고찰 (Clinical Research about the Correlation between Defecation Type and Cold Hypersensitivity of Lower Abdomen, Hand and Foot)

  • 윤성우;하지연;이경섭
    • 대한한방체열의학회지
    • /
    • 제3권1호
    • /
    • pp.36-42
    • /
    • 2004
  • Cold hypersensitivity is the condition with unusual cold sensitivity at temperature when others don't feel so. It is not disease in itself, but is known as having relationship with infertility, dysmenorrhea, anemia and endocrine disorder. The symptoms of cold hypersensitivity appear on limbs and abdomen especially, and may affect bowel movement such as constipation or diarrhea. We made a research of 86 healthy young girls who took medical examination and examined subjective bowel habit. The patients were divided into three group by defecation type, constipation(42), diarrhea(14) and normal group(30). Temperature differences$({\Delta}Ts)$ measured by DITI on upper and lower abdomen of each group had not statistically significance. Otherwise ${\Delta}Ts$ between upper arm and palm and between upper leg and foot were statistically signigicant. The severity of cold hypersensitivity on hands was in order constipation, normal and diarrhea group, and same as feet. The diarrhea patients had more severe cold hypersensitivity as compared with constipation patients. Correlation between ${\Delta}Ts$ on abdomen and hands or feet didn't exist. ${\Delta}Ts$ on hands and feet, however, had positive relationship. This research showed cold hypersensitivity could be related with diarrhea.

  • PDF

좌우 늑골하 부위 체표온도와 혈중 Aminotransferase 농도와의 관계 (Relationship between Aminotransferase and DITI)

  • 김승현;박명원;조정훈;장준복;이경섭
    • 대한한방체열의학회지
    • /
    • 제3권1호
    • /
    • pp.1-5
    • /
    • 2004
  • This study examined the relationship between aminotransferase and DITI in the diagnosis of Liver Qi stagnation. An analysis was performed on the thermographic findings of 17 subjects with abnormally high aminotransferase value and 26 with no problem in blood sample at the Kangnam Korean Hospital, KyungHee University, Seoul, Korea, from March 2003 to May 2003. The body temperature was assessed by DITI thermographic measurements were performed on Rt. and Lt. subcostal area. Value of ${\delta}T$ and absolute value of ${\delta}T$ were tested by Mann-whitney U test. The absolute value of ${\delta}T$ was statistically significant(P<0.00). The ${\delta}T$ was also significant(P<0.01) and the temperature of Rt. area was higher than that of Lt. area. It is believed that DITI may be a favorable alternative to the diagnosis of Liver Qi stagnation.

  • PDF

Standardization of diagnosis of cold hypersensitivity of hands and feet by D.I.T.I.

  • Lee, Kyung-Sub
    • 대한한방체열의학회지
    • /
    • 제3권1호
    • /
    • pp.15-19
    • /
    • 2004
  • Cold hypersensitivity means a condition feeling cold at a temperature when one should not feel so. Cold hypersensitivity has been diagnosed based on the patient's subjective complaints. But these days, cold hypersensitivity can be diagnosed by the help of D.I.T.I.(Digital Infrared Thermal Imaging) This study is designed to verify the validity of diagnosis of cold hypersensitivity by D.I.T.I. Thermographic findings of 100 outpatients who visited the Kangnam Korean Hospital, KyungHee University, Seoul, Korea, from June 2000 to November 2000 were analyzed. The experimental group consisted of 50 patients who complained cold hypersensitivity, and for the control group, 50 patients who did not complain cold hypersensitivity. For the diagnosis of cold hypersensitivity of the hands, thermographic measurements were performed on two pairs of areas(palm-upper arm and back of hand-upper arm). And for that of the feet, other two pairs of areas(anterior thigh-top of the feet and posterior thigh-heel). When the criterion for thermal deviation between the palm and the upper arm was appointed as higher than $0.3^{\circ}C$, the sensitivity was 94.0% and the specificity, 90.0%. And when the criterion for that between the anterior thigh and the top of feet was appointed higher than $2.0^{\circ}C$, the sensitivity was 94.0% and the specificity, 76.0%. Through this study, the diagnostic standard for cold hypersensitivity of hands and feet could be presented.

  • PDF

적외선체열진단을 위한 외부온도 적응과정 중 체온변화 관찰 (1) (Observation of the change of body temperature during the adaptation time in D.I.T.I (1))

  • 박대순;조정훈;장준복;이경섭
    • 대한한방체열의학회지
    • /
    • 제3권1호
    • /
    • pp.20-26
    • /
    • 2004
  • Purpose This study was performed to observe the change of body temperature during preparatory period. Method This study was carried out on 19 patients by D.I.T.I. The temperature was measured on Chondol(CV22), chonjung(CV17), the abdominal region and palm of Rt. and Lt. hand on every minutes for ten minutes. Result and Conclusion In male and female, until 6 minutes mean body temperature decreased but from 7 minutes it increased a little. Temperature in Chondol(CV22) and chonjung(CV17) also had similar tendency. However in the abdominal region temperature decreased and in palm of Rt. and Lt. hand it increased continously for ten minutes

  • PDF

국내논문검색서비스를 이용한 '냉증'에 관한 연구 동향 분석 (Review of cold hypersensitivity in study of Korean traditional medicine)

  • 김진환;장희재;황덕상;이진무;이창훈;이경섭;장준복
    • 대한한방체열의학회지
    • /
    • 제9권1호
    • /
    • pp.8-21
    • /
    • 2011
  • Purpose : This study is to investigate the trends of study of cold hypersensitivity in Korean traditional medicine and to direct for future research. Methods : We searched for papers which had used cold hypersensitivity in korean journals. Results : 25 papers were found. 10 papers were associated with characteristics of cold hypersensitivity. 8 papers were associated with case study. 5 papers were associated with diagnosis. 2 papers were associated with research for treatment effect. Conclusion : Studies have been conducted on cold hypersensitivity in various fields. But evidence is not enough, so more research will be needed.

  • PDF

하지마목을 동반한 갱년기 환자 치험 1 례 (A Clinical Case Study on Climacteric Woman with Numbness of Lower Limbs)

  • 박경선;이경섭;이진무
    • 대한한방체열의학회지
    • /
    • 제9권1호
    • /
    • pp.1-7
    • /
    • 2011
  • Purpose : This study was performed to evaluate the efficacy of herb medicine on climacteric woman with numbness of lower limbs by using Digital Infrared Thermographic Imaging(DITI). Methods : The patient was 56-year-old female who was suffering from numbness, cold hypersensitivity of lower limbs and hot flush. We treated her using herb medicine, acupuncture and moxibustion. The progress of symptoms were evaluated by DITI, and then we compared DITI before treatment and after treatment. Results : After treatment, visual analog scale of numbness and cold hypersensitivity of lower limbs were decreased and frequency of hot flush was also decreased. The temperature of forehead got lower than that before treatment and the temperature of LR3 and ST32 got higher than those before treatment on DITI. Conclusion : This result suggest that DITI can be used for assessment after treatment on climacteric symptoms with numbness of lower limbs.

  • PDF