• 제목/요약/키워드: Thermocycling effect

검색결과 94건 처리시간 0.029초

Effect of aging on tear strength and cytotoxicity of soft denture lining materials; in vitro

  • Landayan, Jordi Izzard Andaya;Manaloto, Adrian Carlos Francisco;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권2호
    • /
    • pp.115-120
    • /
    • 2014
  • PURPOSE. The aim of this in vitro study was to evaluate the effect of aging on the tear strength and cytotoxicity of four soft denture lining materials. MATERIALS AND METHODS. Four commonly used soft denture lining materials, (Coe-Comfort$^{TM}$ GC America Inc., Alsip, IL, USA; Coe-SOFT$^{TM}$ GC America Inc., Alsip, IL, USA; Visco-gel Dentsply Caulk Milford, DE, USA; and Sofreliner Tough M Tokuyama Dental Corporation Tokyo, Japan) were selected. Sixty trouser-leg designed specimens per lining material were fabricated using a stainless steel mold for tear strength testing. The specimens were divided into non-thermocycling and 1000-, and 3000-thermocycling groups. For the cytotoxicity test, twenty-four disk shaped specimens per material were fabricated using a stainless steel mold. The specimens were soaked in normal saline solution for 24 h, 48 h and 72 h. Cytotoxicity was measured by XTT assay in L929 mouse fibroblasts. Data were analyzed by two way analysis of variance and Dunnett's test (P<.05). RESULTS. Before thermocycling, Sofreliner Tough M ($10.36{\pm}1.00N$) had the highest tear strength value while Coe-Comfort$^{TM}$ ($0.46{\pm}0.10N$) had the lowest. After 3000 cycles, Sofreliner Tough M ($9.65{\pm}1.66N$) presented the highest value and Coe-Comfort$^{TM}$ ($0.42{\pm}0.08N$) the lowest. Sofreliner Tough M, in all incubation periods was the least toxic with significant differences compared to all other materials (P<.05). Coe-Comfort$^{TM}$, Coe-$SOFT^{TM}$, and Sofreliner Tough M did not show any significant differences within their material group for all incubation periods. CONCLUSION. This in vitro study revealed that aging can affect both the tear strength and cytotoxicity of soft denture materials depending on the composition.

상아질접착제와 열순환에 따른 유동성 레진의 전단결합강도 비교 연구 (A COMPARATIVE STUDY OF SHEAR BOND STRENGTH OF FLOWABLE RESIN ASSOCIATED WITH DENTIN ADHESIVE SYSTEMS WITH THERMOCYCLING EFFECT)

  • 남기영
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.383-393
    • /
    • 2006
  • Statement of problem : Limited research on flowable resin has been undertaken on its application directly on dentin associated with the adhesive systems. Purpose : This study was to evaluate the shear bond strengh and fracture aspect of flowable resin on human dentin with various types of dentin bonding adhesives with thermo cycling effect. Materials and methods: Filtek-Flow(3M ESPE, USA) was used as flowable resin and Eighty human molars were randomly divided into 4 groups : three dentin bonding adhesives (Scotchbond-Multipurpose : 3-step contentional system, One-Step : One-bottle system. Prompt L-Pop : All-in-one, self-etching primer) and 32% etching treatment without bonding adhesive as a control group. For evaluating their durability of bonding, each group was subdivided : storaging in the water at 37$^{\circ}C$(24 hours) and thermocycling (0$^{\circ}C$-55$^{\circ}C$, 30 seconds intervals, 1000 cycle). Shear bond strength tests were performed and resin-dentin interface and fracture mode were observed. Results were analysed by one-way ANOVA and Scheffe's multiple range test. Results and Conclusion : 1. At 0 cycle, the mean shear bond strength of One-Step exhibited the highest value of all groups(p<0.05), and there were no significant differences between Prompt L-Pop and Scotchbond-Multipurpose, Scotchbond-Multipurpose and control(p>0.05). After 1000 thermocycling, One-Step exhibited higher value than other groups(p<0.05), and there were no significant differences among other groups (p>0.05). 2. The shear bond strength of each group was significantly decreased after thermocycling except Scotchbond-Multipurpose (p>0.05). 3. The most common failure mode was adhesive type and mixed type, next in order.

치과용 Varnish가 충전재의 변연누출에 미치는 영향에 관한 연구 (A STUDY OF CAVITY VARNISH APPLICATION ON THE MARGINAL LEAKAGE OF THE VARIOUS DENTAL RESTORATIONS)

  • 김희중;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제9권1호
    • /
    • pp.69-79
    • /
    • 1983
  • This study was undertaken to evaluate the effects of varnish application and thermocycling on the marginal leakage. 240 cavities of Class V were prepared on the 120 extracted premolars, and the cavities were filled with amalgam, Heliosit$^{(R)}$, and Hipol$^{(R)}$ after application of Copalite$^{(R)}$ or Duraphat$^{(R)}$. All specimens were immersed in methylene blue solution for 24 hours after thermocycling at $4^{\circ}C$ and $60^{\circ}C$, embedded in acrylic resin, and sectioned with low speed saw into two parts. The sectioned specimens observed with the metallurgical microscope. The following results were obtained: 1. The marginal seal was more effective in the amalgam-filled cavities after application of Copalite$^{(R)}$ threetimes or an application of Duraphat$^{(R)}$ varnish than in those without varnish applications. 2. Of the composite resin-filled cavities, the leakage of the varnish applied cases showed much more than without application. 3. There was no significant difference in the effect of marginal sealing between Copalite$^{(R)}$ and Duraphat$^{(R)}$ applications. 4. There was a significant difference in the degree of the marginal leakage of amalgam-filled cavities between the groups of thermocycling times, but no significant difference in the resin-filled cavities. 5. There was no significant difference in the degree of the marginal leakage between the Heliosit$^{(R)}$ and the Hipol$^{(R)}$ resin-filled cavities.

  • PDF

침수 및 열순환에 따른 레진브라켓 wing의 파절강도 변화 (Change of fracture mode of orthodontic resin bracket wings under water immersion and thermocycling)

  • 손지형;황현식
    • 대한치과교정학회지
    • /
    • 제30권4호
    • /
    • pp.475-481
    • /
    • 2000
  • 본 연구는 침수 및 온도변화에 따른 레진 브라켓 wing의 파절양상을 비교하여 구강내 환경이 레진 브라켓 wing의 물성변화에 미치는 영향을 관찰해 보기 위하여 시행되었다. 본 연구의 재료로 레진 브라켓 75개와 금속 브라켓 25개를 사용하였는데, 레진 브라켓은 상온에서 5개월 동안 방치한 경우와 $37^{\circ}C$의 증류수에 6개월 동안 침수시킨 경우, 그리고 $37^{\circ}C$의 증류수에 6개월 동안 침수시킨 상태에서 1개월에 350회씩 총 2,100회의 열순환 시킨 경우의 3가지 군으로 구분하여 처리하였다. 만능물성 시험기를 이용하여 금속 브라켓의 경우 wing의 변형강도를, 레진 브라켓의 경우 파절강도를 각 군별로 측정하고 비교 분석하여 다음과 같은 결과를 얻었다. 1. 금속 브라켓 wing의 변형강도에 비하여 레진 브라켓 wing의 파절강도가 매우 낮게 나타났으며 통계적으로 유의한 차이가 있었다(p<0.001). 2. 상온에서 6개월 동안 방치한 군에 비하여 침수시키거나 침수 및 열순환 시킨 군에서 브라켓 wing의 파절강도가 낮게 나타났으며 통계적으로 유의한 차이를 보였다(p<0.001). 3. 단순침수에 비하여 침수 및 열순한 시킨 군의 브라켓 wing의 파절강도가 더 낮게 나타났으며 통계적으로 유의한 차이가 있었다(p<0.001). 이상의 결과는 구강내 환경에 의하여 레진 브라켓 wing의 물성이 약화되므로 이의 강도증가를 위한 적절한 대책이 필요함을 시사하였다.

  • PDF

The effect of thermocycling on the bonding of different restorative materials to access opening through porcelain fused to metal restorations

  • Al-Moaleem, Mohammed M.;Shah, Farhan Khalid;Khan, Nausheen Saied;Porwal, Amit
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권4호
    • /
    • pp.186-189
    • /
    • 2011
  • PURPOSE. Porcelain fused to metal (PFM) crowns provide the best treatment option for teeth that have a large or defective restoration. More than 20% of teeth with PFM crowns or bridges require non-surgical root canal treatment (NSRCT). This may be due to the effect of restorative procedures and the possible leakage of bacteria and or their by-products, which leads to the demise of the tooth pulp. Thus, this study was planned to compare the ability of the restorative materials to seal perforated PFM specimens. MATERIALS AND METHODS. The study evaluates the ability of amalgam, composite or compomer restorative materials to close perforated PFM specimen's in-vitro. Ninety PFM specimens were constructed using Ni-Cr alloys and feldspathic porcelain, and then they were divided into 3 groups: amalgam (A), composite + Exite adhesive bond (B) and compomer + Syntac adhesive bond (C). All the PFM samples were embedded in an acrylic block to provide complete sealing of the hole from the bottom side. After the aging period, each group was further divided into 3 equal subgroups according to the thermocycling period (one week for 70 cycles, one month for 300 cycles and three months for 900 cycles). Each subgroup was put into containers containing dye (Pelikan INK), one maintained at $5^{\circ}C$ and the other at $55^{\circ}C$, each cycle for 30 sec time. The data obtained was analyzed by SPSS, 2006 using one way ANOVA test and student t-test and significant difference level at (P<.01). RESULTS. The depth of dye penetration was measured at the interfaces of PFM and filling materials using Co-ordinate Vernier Microscope. The lowest levels of the dye penetration for the three groups, as well as subgroups were during the first week. The values of dye leakage had significantly increased by time intervals in subgroups A and C. CONCLUSION. It was seen that amalgam showed higher leakage than composite while compomer showed the lowest level of leakage.

Effect of non-thermal plasma on the shear bond strength of resin cements to Polyetherketoneketone (PEKK)

  • Labriaga, Wilmart;Song, So-Yeon;Park, Jin-Hong;Ryu, Jae-Jun;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권6호
    • /
    • pp.408-414
    • /
    • 2018
  • PURPOSE. This study aimed to assess the effect of non-thermal plasma on the shear bond strength of resin cements to polyetherketoneketone (PEKK) in comparison to other surface treatment methods. MATERIALS AND METHODS. Eighty PEKK discs were subjected to different surface treatments: (1) Untreated (UT); (2) Non-thermal plasma (NTP); (3) Sandblasting with $50{\mu}m$ $Al_2O_3$ particles (SB); and (4) Sandblasting + Non-thermal plasma (SB+NTP). After each surface treatment, the contact angle was measured. Surface conditioning with Visio.Link was applied in all groups after pre-treatment. RelyX Unicem resin cement was bonded onto the PEKK specimens. After fabrication of the specimens, half of each group (n=10) was initially tested, while the other half was subjected to thermocycling ($5^{\circ}C$ to $55^{\circ}C$ at 10,000 cycles). Shear bond strength (SBS) testing was performed using a universal testing machine, and failure modes were assessed using stereomicroscopy. The SBS results were analyzed statistically using one-way ANOVA followed by Tukey's post hoc test. Independent t-test was used to examine the effect of thermocycling (P<.05). RESULTS. The highest SBS values with or without thermocycling were observed with PEKK specimens that were treated with SB+NTP followed by the SB group. The lowest SBS results were observed in the UT groups. CONCLUSION. The shear bond strength between PEKK and resin cements was improved using non-thermal plasma treatment in combination with sandblasting.

Effect of different chlorhexidine application times on microtensile bond strength to dentin in Class I cavities

  • Kang, Hyun-Jung;Moon, Ho-Jin;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • 제37권1호
    • /
    • pp.9-15
    • /
    • 2012
  • Objectives: This study evaluated the effect of 2% chlorhexidine digluconate (CHX) with different application times on microtensile bonds strength (MTBS) to dentin in class I cavities and intended to search for ideal application time for a simplified bonding protocol. Materials and Methods: Flat dentinal surfaces with class I cavities ($4mm{\times}4mm{\times}2mm$) in 40 molar teeth were bonded with etch-and-rinse adhesive system, Adper Single Bond 2 (3M ESPE) after: (1) etching only as a control group; (2) etching + CHX 5 sec + rinsing; (3) etching + CHX 15 sec + rinsing; (4) etching + CHX 30 sec + rinsing; and (5) etching + CHX 60 sec + rinsing. Resin composite was builtup with Z-250 (3M ESPE) using a bulk method and polymerized for 40 sec. For each condition, half of the specimens were immediately submitted to MTBS test and the rest of them were assigned to thermocycling of 10,000 cycles between $5^{\circ}C$ and $55^{\circ}C$ before testing. The data were analyzed using two-way ANOVA, at a significance level of 95%. Results: There was no significant difference in bond strength between CHX pretreated group and control group at the immediate testing period. After thermocycling, all groups showed reduced bond strength irrespective of the CHX use. However, groups treated with CHX maintained significantly higher MTBS than control group (p < 0.05). In addition, CHX application time did not have any significant influence on the bond strength among groups treated with CHX. Conclusion: Application of 2% CHX for a short time period (5 sec) after etching with 37% phosphoric acid may be sufficient to preserve dentin bond strength.

열순환이 상아질 접착제의 결합 내구성에 미치는 영향 (THE EFFECT OF THERMOCYCLING ON THE DURABILITY OF DENTIN ADHESIVE SYSTEMS)

  • 문영훈;김종률;최경규;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제32권3호
    • /
    • pp.222-235
    • /
    • 2007
  • 이 논문의 목적은 열순환이 4종 상아질 접착 시스템의 결합 내구성에 미치는 영향을 측정한 것이다. 제3대구치의 상아질층을 노출시킨 후, 무작위로 8개군으로 나눈다: 3단계 산부식 시스템 (Scotchbond Multi-Purpose Plus; SM, All Bond-2 ; AB), 2 단계 산부식 시스템 (Single Bond; SB, One Step plus, OS), 2단계 자가부식 시스템 (Clearfil SE Bond; SE, AdheSE; AD), 1 단계 자가부식 시스템 (Promp L-Pop ; PL, Xeno III; XE). 8개 군에 각 상아질 접착제를 제조사의 지시에 따라 도포하고 복합레진 (Z250)을 적층한 후, 광조사한다. $37^{\circ}C$ 증류수에서 24시간 보관한 후, 각 군마다 정해진 프로그램으로 0, 1000, 2000회 열순환한 후, 저속 diamond saw로 $1\times1mm$ 막대형 시편을 제작한다. Universal testing machine (EZ-test; Shimadzu, Japan)으로 미세인장 결합강도를 측정하였고, 유의수준 0.05 level에서 ANOVA / Duncan's test로 통계분석 하였다. 상아질측 파단면과 접착계면에 대한 주사전자현미경 관찰을 시행하였다. 이 연구의 결과는 다음과 같다; 1. 3단계 상아질 접착제의 결합강도는 열순환 전후에 통계학적으로 유의한 변화를 나타내지 않았다. 2단계 산부식형 상아질 접착제의 결합강도는 열순환 처리에 의하여 유의하게 감소되었다. 2. 2단계 자가부식형 접착제 (SE)의 결합강도가 가장 높았고, 1단계 자가부식 접착제 (PL, XE)는 실험군 중 가장 낮은 결합강도를 보였다. 3. 모든 접착제는 주로 접착성 파괴가 발생하였고, 열순환에 의하여 산부식형 접착제는 접착성 파괴가, 1단계 자가부식형 접착제에서는 혼합형 파괴가 증가하는 경향을 나타내었다. 이상의 결과로, 상아질 접착제의 접착단계/과정이 결합내구성에 영향을 미침을 알 수 있었다. 따라서 접착과정의 단순화가 반드시 접착에 효과적이라고 할 수 없다.

열순환이 상아질접착제 처리 후 미세누출에 미치는 영향에 관한 연구 (The Study of the Effect of Thermocycling on Microleakage within Various Dentin Bonding Agents)

  • 유승훈
    • 구강회복응용과학지
    • /
    • 제24권2호
    • /
    • pp.147-155
    • /
    • 2008
  • 5세대 상아질 접착제인 Adper Single bond 2.0 (3M-ESPE, USA), 6세대 상아질 접착제인 Prompt L-pop (3M-ESPE, USA), AdheSE (Ivoclar Vivadent, Liechtenstein) 를 각 상아질 접착제당 30개의 건전한 소구치 및 대구치를 선정하여 협면과 설면에 5급와동을 형성하고 복합레진을 적용하였다. 이중 절반은 열순환을 시행하지 않고 나머지 절반은 열순환을 시행하였다. 이후 메틸렌 블루를 침투시켜 시약의 침투 정도를 측정한 후 통계분석하였다. 열순환을 시행하지 않은 군과 열순환을 시행한 군을 통틀어 열순환을 시행하지 않은 상아질 군에서만 Single Bond 2.0의 미세누출의 양이 Prompt L-Pop과 AdheSE에 비하여 높았고 (p <.05) 나머지 군에서는 모두 Single Bond 2.0의 미세누출의 양이 적었다. (p <.05) 열순환 이후에 미세누출의 양이 늘어난 군은 Prompt L-Pop과 AdheSE의 상아질 군이었다.

Effect of chlorhexidine application on the bond strength of resin core to axial dentin in endodontic cavity

  • Kim, Yun-Hee;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • 제37권4호
    • /
    • pp.207-214
    • /
    • 2012
  • Objectives: This study evaluated the influence of chlorhexidine (CHX) on the microtensile bonds strength (${\mu}TBS$) of resin core with two adhesive systems to dentin in endodontic cavities. Materials and Methods: Flat dentinal surfaces in 40 molar endodontic cavities were treated with self-etch adhesive system, Contax (DMG) and total-etch adhesive system, Adper Single Bond 2 (3M ESPE) after the following surface treatments: (1) Priming only (Contax), (2) CHX for 15 sec + rinsing + priming (Contax), (3) Etching with priming (Adper Single Bond 2), (4) Etching + CHX for 15 sec + rinsing + priming (Adper Single Bond 2). Resin composite build-ups were made with LuxaCore (DMG) using a bulk method and polymerized for 40 sec. For each condition, half of specimens were submitted to ${\mu}TBS$ after 24 hr storage and half of them were submitted to thermocycling of 10,000 cycles between $5^{\circ}C$ and $55^{\circ}C$ before testing. The data were analyzed using ANOVA and independent t-test at a significance level of 95%. Results: CHX pre-treatment did not affect the bond strength of specimens tested at the immediate testing period, regardless of dentin surface treatments. However, after 10,000 thermocycling, all groups showed reduced bond strength. The amount of reduction was greater in groups without CHX treatments than groups with CHX treatment. These characteristics were the same in both self-etch adhesive system and total-etch adhesive system. Conclusions: 2% CHX application for 15 sec proved to alleviate the decrease of bond strength of dentin bonding systems. No significant difference was shown in ${\mu}TBS$ between total-etching system and self-etching system.