Browse > Article
http://dx.doi.org/10.4047/jap.2014.6.2.115

Effect of aging on tear strength and cytotoxicity of soft denture lining materials; in vitro  

Landayan, Jordi Izzard Andaya (Graduate School of Clinical Dentistry, Institute for Clinical Dental Research, Korea University)
Manaloto, Adrian Carlos Francisco (Graduate School of Clinical Dentistry, Institute for Clinical Dental Research, Korea University)
Lee, Jeong-Yol (Graduate School of Clinical Dentistry, Institute for Clinical Dental Research, Korea University)
Shin, Sang-Wan (Graduate School of Clinical Dentistry, Institute for Clinical Dental Research, Korea University)
Publication Information
The Journal of Advanced Prosthodontics / v.6, no.2, 2014 , pp. 115-120 More about this Journal
Abstract
PURPOSE. The aim of this in vitro study was to evaluate the effect of aging on the tear strength and cytotoxicity of four soft denture lining materials. MATERIALS AND METHODS. Four commonly used soft denture lining materials, (Coe-Comfort$^{TM}$ GC America Inc., Alsip, IL, USA; Coe-SOFT$^{TM}$ GC America Inc., Alsip, IL, USA; Visco-gel Dentsply Caulk Milford, DE, USA; and Sofreliner Tough M Tokuyama Dental Corporation Tokyo, Japan) were selected. Sixty trouser-leg designed specimens per lining material were fabricated using a stainless steel mold for tear strength testing. The specimens were divided into non-thermocycling and 1000-, and 3000-thermocycling groups. For the cytotoxicity test, twenty-four disk shaped specimens per material were fabricated using a stainless steel mold. The specimens were soaked in normal saline solution for 24 h, 48 h and 72 h. Cytotoxicity was measured by XTT assay in L929 mouse fibroblasts. Data were analyzed by two way analysis of variance and Dunnett's test (P<.05). RESULTS. Before thermocycling, Sofreliner Tough M ($10.36{\pm}1.00N$) had the highest tear strength value while Coe-Comfort$^{TM}$ ($0.46{\pm}0.10N$) had the lowest. After 3000 cycles, Sofreliner Tough M ($9.65{\pm}1.66N$) presented the highest value and Coe-Comfort$^{TM}$ ($0.42{\pm}0.08N$) the lowest. Sofreliner Tough M, in all incubation periods was the least toxic with significant differences compared to all other materials (P<.05). Coe-Comfort$^{TM}$, Coe-$SOFT^{TM}$, and Sofreliner Tough M did not show any significant differences within their material group for all incubation periods. CONCLUSION. This in vitro study revealed that aging can affect both the tear strength and cytotoxicity of soft denture materials depending on the composition.
Keywords
Soft liner; Tear strength; Thermocycling; Cytotoxicity; L929 mouse fibroblasts; XTT Assay;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Pesun IJ, Hodges J, Lai JH. Effect of finishing and polishing procedures on the gap width between a denture base resin and two long-term, resilient denture liners. J Prosthet Dent 2002;87:311-8.   DOI   ScienceOn
2 Murphy WM, Huggett R, Handley RW, Brooks SC. Rigid cold curing resins for direct use in the oral cavity. Br Dent J 1986;160:391-4.   DOI   ScienceOn
3 Qudah S, Harrison A, Huggett R. Soft lining materials in prosthetic dentistry: a review. Int J Prosthodont 1990;3:477-83.
4 Anusavice KJ. Phillips' science of dental materials. St. Louis; Mo.; WB Saunders; 2003.
5 Causton BE. Denture base polymers and liners. In: O'Brian WJ, eds. Dental materials and their selection. Chicago; Quintessence; 1997. p. 90-2.
6 Ozdemir KG, Yilmaz H, Yilmaz S. In vitro evaluation of cytotoxicity of soft lining materials on L929 cells by MTT assay. J Biomed Mater Res B Appl Biomater 2009;90:82-6.
7 Shanmuganathan N, Padamanabhan TV, Subramaniam R, Madhankumar S. The compliance of temporary soft lining materials-an in vivo & vitro study. Int J Sci Res Publ 2012;2:1-7.
8 Polyzois GL, Hensten-Pettersen A, Kullmann A. An assessment of the physical properties and biocompatibility of three silicone elastomers. J Prosthet Dent 1994;71:500-4.   DOI   ScienceOn
9 Park SK, Lee YK, Lim BS, Kim CW. Changes in properties of short-term-use soft liners after thermocycling. J Oral Rehabil 2004;31:717-24.   DOI   ScienceOn
10 Chaves CA, Machado AL, Vergani CE, de Souza RF, Giampaolo ET. Cytotoxicity of denture base and hard chairside reline materials: a systematic review. J Prosthet Dent 2012;107:114-27.   DOI   ScienceOn
11 Munksgaard EC. Leaching of plasticizers from temporary denture soft lining materials. Eur J Oral Sci 2004;112:101-4.   DOI   ScienceOn
12 International Standards Organization (ISO). 10993-5:1992. Biological evaluation of medical devices - Part 5: Tests for in vitro cytotoxicity. International Standards Organization, Geneva; Switzerland; 1992.
13 Hensten-Pettersen A. Comparison of the methods available for assessing cytotoxicity. Int Endod J 1988;21:89-99.
14 Heravi F, Ramezani M, Poosti M, Hosseini M, Shajiei A, Ahrari F. In Vitro Cytotoxicity Assessment of an Orthodontic Composite Containing Titanium-dioxide Nano-particles. J Dent Res Dent Clin Dent Prospects 2013;7:192-8.
15 Jepson NJ, McCabe JF, Storer R. Evaluation of the viscoelastic properties of denture soft lining materials. J Dent 1993;21:163-70.   DOI   ScienceOn
16 Lytle RB. Complete denture construction based on a study of the deformation of the underlying soft tissues. J Prosthet Dent 1959;9:539-51.   DOI
17 Mjör IA. Biologic assessment of restorative dental materials: interrelationship of biologic and technologic properties. Oper Dent 1978;3:9-13.
18 Huang FM, Tai KW, Hu CC, Chang YC. Cytotoxic effects of denture base materials on a permanent human oral epithelial cell line and on primary human oral fibroblasts in vitro. Int J Prosthodont 2001;14:439-43.
19 Lefebvre CA, Schuster GS. Biocompatibility of visible lightcured resin systems in prosthodontics. J Prosthet Dent 1994;71:178-85.   DOI   ScienceOn
20 International Standards Organization (ISO). ISO 7405:1997. Pre clinical evaluation of biocompatibility of medical devices used in dentistry: Test methods for dental materials. International Standards Organization: Geneva; Switzerland;1997.
21 Thonemann B, Schmalz G, Hiller KA, Schweikl H. Responses of L929 mouse fibroblasts, primary and immortalized bovine dental papilla-derived cell lines to dental resin components. Dent Mater 2002;18:318-23.   DOI   ScienceOn
22 Bouillaguet S, Shaw L, Gonzalez L, Wataha JC, Krejci I. Long-term cytotoxicity of resin-based dental restorative materials. J Oral Rehabil 2002;29:7-13.   DOI   ScienceOn
23 Roehm NW, Rodgers GH, Hatfield SM, Glasebrook AL. An improved colorimetric assay for cell proliferation and viability utilizing the tetrazolium salt XTT. J Immunol Methods 1991;142:257-65.   DOI   ScienceOn
24 Pinto JR, Mesquita MF, Nóbilo MA, Henriques GE. Evaluation of varying amounts of thermal cycling on bond strength and permanent deformation of two resilient denture liners. J Prosthet Dent 2004;92:288-93.   DOI   ScienceOn
25 Stevens MG, Olsen SC. Comparative analysis of using MTT and XTT in colorimetric assays for quantitating bovine neutrophil bactericidal activity. J Immunol Methods 1993;157:225-31.   DOI   ScienceOn
26 Dootz ER, Koran A, Craig RG. Physical property comparison of 11 soft denture lining materials as a function of accelerated aging. J Prosthet Dent 1993;69:114-9.   DOI   ScienceOn
27 Hekimoğlu C, Anil N. The effect of accelerated ageing on the mechanical properties of soft denture lining materials. J Oral Rehabil 1999;26:745-8.   DOI
28 Qudah S, Huggett R, Harrison A. The effect of thermocycling on the hardness of soft lining materials. Quintessence Int 1991;22:575-80.
29 Oguz S, Mutluay MM, Dogan OM, Bek B. Effect of thermocycling on tensile strength and tear resistance of four soft denture liners. Dent Mater J 2007;26:296-302.   DOI
30 Murata H, Iwanaga H, Shigeto N, Hamada T. Initial flow of tissue conditioners-influence of composition and structure on gelation. J Oral Rehabil 1993;20:177-87.   DOI   ScienceOn
31 Ciapetti G, Granchi D, Stea S, Savarino L, Verri E, Gori A, Savioli F, Montanaro L. Cytotoxicity testing of materials with limited in vivo exposure is affected by the duration of cellmaterial contact. J Biomed Mater Res 1998;42:485-90.   DOI
32 León BL, Del Bel Cury AA, Rodrigues Garcia RC. Water sorption, solubility, and tensile bond strength of resilient denture lining materials polymerized by different methods after thermal cycling. J Prosthet Dent 2005;93:282-7.   DOI   ScienceOn
33 Sertgoz A, Kulak Y, Gedik H, Taskonak B. The effect of thermocycling on peel strength of six soft lining materials. J Oral Rehabil 2002;29:583-7.   DOI   ScienceOn
34 Hanks CT, Strawn SE, Wataha JC, Craig RG. Cytotoxic effects of resin components on cultured mammalian fibroblasts. J Dent Res 1991;70:1450-5.   DOI   ScienceOn