• 제목/요약/키워드: Thermal-Vacuum Test

검색결과 188건 처리시간 0.03초

실시간 플랜트 시뮬레이터를 이용한 우주 열환경 챔버 제어기 개발에 관한 연구 (Study on the application of a realtime simulator to the development of a controller for a space thermal environment chamber)

  • 정무진;신영기;최석원;문귀원;서희준;이상훈;조혁진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.216-221
    • /
    • 2003
  • A thermal vacuum chamber is mainly used to simulate thermal environments of a test satellite in satellite orbits in which daily temperature variations range from 80K to above 400K depending on solar radiation under the vacuum below $10^{-4}$ torr. The test facility is quite complex and consists of expensive parts. So any modification of control software is discouraged in fear of unexpected system failure. The purpose of this study is to develop a realtime dynamics model of the thermal vacuum chamber in view of controller design and simulate its electrical inputs and outputs for interface with a PLC (programmable logic controller). A PLC program that was used in the thermal vacuum chamber is applied to the realtime simulator. The realized simulator dynamics is found to be quite similar to that of the thermal vacuum chamber and serve to an appropriate plant to verify the control performance of a programmed PLC.

  • PDF

열진공 챔버용 극저온 블로워 설계 및 성능평가 (Design and Performance Tests of a Cryogenic Blower for a Thermal Vacuum Chamber)

  • 서희준;조혁진;박성욱;문귀원;허환일
    • 한국항공우주학회지
    • /
    • 제43권11호
    • /
    • pp.1008-1015
    • /
    • 2015
  • 위성체의 지상 검증 시험에는 열진공 챔버가 사용되며, 열제어 시스템은 열진공 챔버의 핵심이라고 할 수 있다. 특히, 기체 질소를 이용한 폐회로 열제어 시스템의 성능은 극저온 블로워의 성능에 의해 결정된다. 본 연구의 최종 목표는 설계 요구조건 $-150^{\circ}C{\sim}150^{\circ}C$의 온도 조건, 유량 150 CFM, 0.5 bara 이상의 차압을 갖는 극저온 블로워를 개발하는 것으로, 1차원 해석툴 및 CFD를 이용한 성능해석을 통해 임펠러를 설계 하였으며, 구동부와 유체부의 열전달 방지를 위한 열장벽, 모터의 과열 방지를 위한 냉각 시스템 등이 설계되었다. 표준대기상태에서 실험을 통해 성능을 검증하였으며, 최종적으로 열진공 챔버내에 설치하여 운영 조건에서 극저온 블로워의 성능을 확인하였다.

저궤도 인공위성 열-구조 모델 열진공시험 결과를 활용한 열모델 보정 (The Correlation of Satellite Thermal Mathematical Model using Results of Thermal Vacuum Test on Structure-Thermal Model)

  • 이장준;김희경;현범석
    • 한국항공우주학회지
    • /
    • 제37권9호
    • /
    • pp.916-922
    • /
    • 2009
  • 우주공간에서 임무를 수행하는 인공위성의 열설계는 열모델을 활용한 열해석 결과를 바탕으로 수행되므로, 열모델의 정확성은 매우 중요하며 이것은 보정과정을 통하여 향상된다. 열모델의 보정은 인공위성이 열진공 챔버에 장착된 형상을 모사하는 모델링에서 시작하여 실제형상과 열모델간의 일치성에 대한 검증, 거시적 변수에서부터 미시적 변수에 이르기까지 열모델 변수에 대한 조정 등을 거쳐 주어진 성공 조건을 만족할 때까지 열모델을 지속적으로 수정하는 과정으로 이루어진다. 본 연구에서는 열모델 보정의 성공 기준을 수립하고 인공위성 열-구조 모델 열진공 시험결과를 활용한 열모델 보정을 수행하여 보정 기준을 충족시켰다. 본 연구에서 보정이 완료된 열모델은 저궤도 인공위성 상세 열설계에 적용될 수 있었다.

과학위성 1호 인증모델 열진공 시험 (Thermal Vacuum Test of Kaistsat-4 Qm)

  • 김도형;정연황;탁경모;이준호;차원호;이상현;최석원;문귀원
    • 한국항공우주학회지
    • /
    • 제31권1호
    • /
    • pp.120-124
    • /
    • 2003
  • KAIST 인공위성연구센터에서는 우리별 1, 2, 3호의 개발에 이어 과학위성 1호를 개발하고 있다. 2003년에 발사 예정인 과학위성 1호는 현재 인증모델 단계의 개발 및 시험이 완료되었다. 본 인증모델 열진공 시험에서는 위성의 각 서브시스템이 예상되는 궤도 상의 온도보다 가혹한 조건에서 시험되었고, 열해석 모델의 검증 및 수정을 위한 열진공평형 시험도 수행되었다. 본 논문에서는 과학위성 1호의 인증모델 열진공 시험 과정 및 결과와 더불어 그 과정에서 알아낸 문제점 및 개선방안 등을 살펴보고, 또한 향후 유사한 소형위성 열진공 시험에 유용하게 쓰일 수 있는 고려 사항들을 검토한다.

Construction of a Thermal Vacuum Chamber for Environment Test of Triple CubeSat Mission TRIO-CINEMA

  • Jeon, Jeheon;Lee, Seongwhan;Yoon, Seyoung;Seon, Jongho;Jin, Ho;Lee, Donghun;Lin, Robert P.
    • Journal of Astronomy and Space Sciences
    • /
    • 제30권4호
    • /
    • pp.335-344
    • /
    • 2013
  • TRiplet Ionospheric Observatory-CubeSat for Ion, Neutron, Electron & MAgnetic fields (TRIO-CINEMA) is a CubeSat with 3.14 kg in weight and 3-U ($10{\times}10{\times}30$ cm) in size, jointly developed by Kyung Hee University and UC Berkeley to measure magnetic fields of near Earth space and detect plasma particles. When a satellite is launched into orbit, it encounters ultra-high vacuum and extreme temperature. To verify the operation and survivability of the satellite in such an extreme space environment, experimental tests are conducted on the ground using thermal vacuum chamber. This paper describes the temperature control device and monitoring system suitable for CubeSat test environment using the thermal vacuum chamber of the School of Space Research, Kyung Hee University. To build the chamber, we use a general purpose thermal analysis program and NX 6.0 TMG program. We carry out thermal vacuum tests on the two flight models developed by Kyung Hee University based on the thermal model of the TRIO-CINEMA satellite. It is expected from this experiment that proper operation of the satellite in the space environment will be achieved.

정지궤도 위성의 열해석 모델 보정 (THERMAL MODEL CORRELATION OF A GEOSTATIONARY SATELLITE)

  • 전형열;김정훈
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.230-235
    • /
    • 2011
  • COMS (Communication, Ocean and Meteorological Satellite) is a geostationary satellite and was developed by KARI for communication, ocean and meteorological observations. COMS was tested under vacuum and very law temperature conditions in order to correlate thermal model and to verify thermal design. The test was performed by using KARI large thermal vacuum chamber. The COMS S/C thermal model was successfully correlated versus the 2 thermal balance test phases. After model correlation, temperatures deviation of all individual unit were less than $5^{\circ}C$ and global deviation and standard deviation also satisfied the requirements, less than $2^{\circ}C$ and $3^{\circ}C$. The final flight prediction was performed by using the correlated thermal model.

  • PDF

지구 정지궤도 위성의 열해석 모델 보정 (THERMAL MODEL CORRELATION OF A GEOSTATIONARY SATELLITE)

  • 전형열;김정훈
    • 한국전산유체공학회지
    • /
    • 제16권3호
    • /
    • pp.59-65
    • /
    • 2011
  • COMS (Communication, Ocean and Meteorological Satellite) is a geostationary satellite and was developed by KARI for communication, ocean and meteorological observations. COMS was tested under vacuum and very low temperature conditions in order to correlate thermal model and to verify thermal design. The test was performed by using KARI large thermal vacuum chamber. The COMS S/C thermal model was successfully correlated versus the 2 thermal balance test phases. After model correlation, temperatures deviation of all individual units were less than $5^{\circ}C$ and global deviation and standard deviation also satisfied the requirements, less than $2^{\circ}C$ and $3^{\circ}C$. The final flight prediction was performed by using the correlated thermal model.

Specific Heat Measurement of Insulating Material using Heat Diffusion Method

  • Choi, Yeon-Suk;Kim, Dong-Lak
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권2호
    • /
    • pp.32-35
    • /
    • 2012
  • The objective of the present work is to develop a precise instrument for measuring the thermal property of insulating material over a temperature range from 30 K to near room temperature by utilizing a cryocooler. The instrument consists of two thermal links, a test sample, heat sink, heat source and vacuum vessel. The cold head of the cryocooler as a heat sink is thermally anchored to the thermal link and used to bring the apparatus to a desired temperature in a vacuum chamber. An electric heater as a heat source is placed in the middle of test sample for generating uniform heat flux. The entire apparatus is covered by thermal shields and wrapped in multi-layer insulation to minimize thermal radiation in a vacuum chamber. For a supplied heat flux the temperature distribution in the insulating material is measured in steady and transient state. The thermal conductivity of insulating material is measured from temperature difference for a given heat flux. In addition, the specific heat of insulating material is obtained by solving one-dimensional heat diffusion equation.

STM 열진공 시험 결과를 이용한 EOS-C Ver.3.0 열제어계 설계 검증 (Design Verification of Thermal Control Subsystem for EOS-C Ver.3.0 using STM Thermal Vacuum Test Result)

  • 장진수;양승욱;정연황
    • 한국항공우주학회지
    • /
    • 제38권12호
    • /
    • pp.1232-1239
    • /
    • 2010
  • (주)쎄트렉아이는 지구관측위성의 주 탑재체로 사용될 고해상도 전자광학카메라, EOS-C Ver.3.0을 개발 중이다. EOS-C Ver.3.0은 현재 운용중인 DubaiSat-1의 주 탑재체인 EOS-C Ver.2.0 개발 경험을 바탕으로 능동 열제어 방식과 수동 열제어 방식을 적절하게 혼용하여 보다 향상된 성능을 갖도록 설계되었다. 설계를 바탕으로 STM을 개발하여 인증(qualification) 수준의 열진공 시험을 수행하여 설계 여유(design margin)를 확인하였다. 또한 열평형 시험 결과를 이용하여 열제어계 설계에 사용한 열-수치 모델에 대한 검증 작업을 수행하였으며, 열-수치 모델이 실제 열적 특성을 잘 모사하고 있음을 확인하였다.

PVDF 중공사막을 이용한 진공 막 증류 모듈의 공급수 조건에 따른 열성능 특성에 관한 실험적 연구 (An Experimental Study on the Characteristic of Thermal Performance according to Feed Water Conditions to of Vacuum Membrane Distillation Module using PVDF Hollow Fiber)

  • 주홍진;곽희열
    • 상하수도학회지
    • /
    • 제31권4호
    • /
    • pp.339-346
    • /
    • 2017
  • In this study, thermal performance test of VMD module was performed, prior to the construction of the demonstration plant using the vacuum membrane distillation (VMD) module of the capacity of $400m^3/day$ and to the commercialization of the VMD module. For the thermal performance test, the experimental equipment of capacity of $2m^3/day$ was constructed. The permeate flux test and thermal performance test according to feed water conditions such as temperature and flow rate were conducted. The VMD module used in the study was manufactured by ECONITY Co., LTD with PVDF hollow fiber membrane. As a result, the Performance Ratio (PR) of the VMD module showed the maximum value of 0.904 under the condition of feed water temperature of $75^{\circ}C$ and flow rate of $8m^3/h$. PR value of the VMD module using PVDF hollow fiber membrane showed linearly increasing relationship with feed water temperature and flow rate. Also, The permeate flux of the VMD module was analyzed to have maximum value of 18.25 LMH and the salt rejection was 99.99%.